{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518374","name":"B&W Resources Inc","status":"Abandoned","status_date":"2002-11-26","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Perry","nearest_town":"Chavies","operator_id":"P24596","operator_name":"B & W Resources Inc","controller_id":"0079793","controller_name":"Lipari Energy","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.35,"longitude":-83.323888},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":62},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518374","name":"B&W Resources Inc"},"operator":{"type":"operator","id":"P24596","name":"B & W Resources Inc"},"controller":{"type":"controller","id":"0079793","name":"Lipari Energy"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24596","name":"B & W Resources Inc"},"object":{"type":"mine","id":"1518374","name":"B&W Resources Inc"},"validFrom":"2001-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518374|P24596|2001-05-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16027","name":"David  Wells"},"object":{"type":"mine","id":"1518374","name":"B&W Resources Inc"},"validFrom":"2001-05-01","validTo":"2008-09-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518374|C16027|2001-05-01|2008-09-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16027","name":"David  Wells"},"object":{"type":"operator","id":"P24596","name":"B & W Resources Inc"},"validFrom":"2001-05-01","validTo":"2008-09-11","current":false,"derived":true,"evidenceMineId":"1518374","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518374|P24596|2001-05-01|C16027|2001-05-01|98116"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0079793","name":"Lipari Energy"},"object":{"type":"mine","id":"1518374","name":"B&W Resources Inc"},"validFrom":"2008-09-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518374|0079793|2008-09-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0079793","name":"Lipari Energy"},"object":{"type":"operator","id":"P24596","name":"B & W Resources Inc"},"validFrom":"2008-09-12","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518374","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518374|P24596|2001-05-01|0079793|2008-09-12|12523"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":2,"firstDate":"2001-12-04","lastDate":"2002-06-19","metrics":{"daysLost":259,"injuries":2,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"130249","DOCUMENT_NO":"220022000038","ACCIDENT_DT":"06/19/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","DAYS_LOST":"256","NARRATIVE":"AS EE WAS ENTERING HIS LOAD AFTER THE NOON LUNCH BREAK, HE BENT OVER TO WIPE THE DUST FROM THE BOTTOM OF THE DOOR. EE STATED THAT HE FELT A SHARP PAIN IN HIS LOWER BACK. HE REPORTED THE INCIDE NT TO THE FOREMAN AND DROVE HIMSELF HOME. HIS DIAGNOSIS IS PENDING.","sourceDate":"2002-06-19"},{"SOURCE_ROW_NUMBER":"40119","DOCUMENT_NO":"220020220166","ACCIDENT_DT":"12/04/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Blaster, Shooter, Shotfirer, Explosive worker, Powder gang/monkey","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"EE WAS LOADING THE EXPLOSIVES TRUCK. WHEN HE RAISED THE HANDLE OF THE POWDER BIN (WHICH ALLOWS AMONIUM NITRATE TO FLOW INTO THE TRUCK) HE FELT ASHARP PAIN IN HIS LOWER BACK. HE DROVE HIMSELF T O THE HAZARD ARH WHERE HE WAS TREATED FOR A PULLED MUSCLE IN HIS BACK AND RELEASED.","sourceDate":"2001-12-04"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-11-26","lastDate":"2002-11-26","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":3,"firstDate":"2001-11-19","lastDate":"2002-10-22","metrics":{"ss":0,"delinquent":3,"recentRows":0,"paidPenalty":165,"proposedPenalty":165,"currentAssessment":165},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1114549","VIOLATION_NO":"7472254","ISSUE_DT":"10/22/2002","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"1114427","VIOLATION_NO":"7472426","ISSUE_DT":"04/16/2002","CFR_STANDARD_CD":"77.400(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-16"},{"SOURCE_ROW_NUMBER":"1114377","VIOLATION_NO":"7472376","ISSUE_DT":"11/19/2001","CFR_STANDARD_CD":"77.1302(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-19"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":16,"firstDate":"2001-09-06","lastDate":"2002-05-21","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":2,"validSamples":14,"maxConcentration":0.516,"concentrationTotal":1.757},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1654266","CASS_NUM":"57433493","SMP_TAKEN_DT":"5/21/2002","CONC":".117","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"846122","CASS_NUM":"57433527","SMP_TAKEN_DT":"5/21/2002","CONC":".081","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"589242","CASS_NUM":"57433520","SMP_TAKEN_DT":"5/21/2002","CONC":".039","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"425867","CASS_NUM":"57433521","SMP_TAKEN_DT":"5/21/2002","CONC":".059","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"77786","CASS_NUM":"57433490","SMP_TAKEN_DT":"5/21/2002","CONC":".017","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INSUFFICIENT DUST OBSERVED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"38011","CASS_NUM":"57433516","SMP_TAKEN_DT":"5/21/2002","CONC":".016","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"1648846","CASS_NUM":"57404021","SMP_TAKEN_DT":"2/19/2002","CONC":".017","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-19"},{"SOURCE_ROW_NUMBER":"1284944","CASS_NUM":"57404095","SMP_TAKEN_DT":"2/19/2002","CONC":".442","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-19"},{"SOURCE_ROW_NUMBER":"726189","CASS_NUM":"57404001","SMP_TAKEN_DT":"2/19/2002","CONC":".01","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-19"},{"SOURCE_ROW_NUMBER":"598614","CASS_NUM":"57404091","SMP_TAKEN_DT":"2/19/2002","CONC":".285","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"MALFUNCTIONING PUMP","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-19"},{"SOURCE_ROW_NUMBER":"566057","CASS_NUM":"57404089","SMP_TAKEN_DT":"2/19/2002","CONC":".023","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-19"},{"SOURCE_ROW_NUMBER":"1487786","CASS_NUM":"57340137","SMP_TAKEN_DT":"9/6/2001","CONC":".125","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-09-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2002-05-14","lastDate":"2002-05-14","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2001-05-01","lastDate":"2001-05-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":14,"firstDate":"2001-06-05","lastDate":"2002-11-21","metrics":{"inspectors":14,"recentRows":0,"onSiteHours":136.5,"inspectionHours":181.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"555262","EVENT_NO":"4232924","INSPECTION_BEGIN_DT":"11/21/2002","INSPECTION_END_DT":"11/21/2002","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2002-11-21"},{"SOURCE_ROW_NUMBER":"260934","EVENT_NO":"4226371","INSPECTION_BEGIN_DT":"10/22/2002","INSPECTION_END_DT":"10/24/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"22","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"540468","EVENT_NO":"4226367","INSPECTION_BEGIN_DT":"10/09/2002","INSPECTION_END_DT":"10/09/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2002-10-09"},{"SOURCE_ROW_NUMBER":"744643","EVENT_NO":"4232908","INSPECTION_BEGIN_DT":"09/24/2002","INSPECTION_END_DT":"09/24/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2002-09-24"},{"SOURCE_ROW_NUMBER":"1134575","EVENT_NO":"4232661","INSPECTION_BEGIN_DT":"05/21/2002","INSPECTION_END_DT":"05/22/2002","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"385620","EVENT_NO":"4232660","INSPECTION_BEGIN_DT":"05/21/2002","INSPECTION_END_DT":"06/06/2002","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"1134829","EVENT_NO":"4226178","INSPECTION_BEGIN_DT":"04/15/2002","INSPECTION_END_DT":"04/23/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"50","SUM_TOTAL_ON_SITE_HOURS":"42","sourceDate":"2002-04-15"},{"SOURCE_ROW_NUMBER":"826872","EVENT_NO":"4232618","INSPECTION_BEGIN_DT":"02/19/2002","INSPECTION_END_DT":"02/28/2002","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2002-02-19"},{"SOURCE_ROW_NUMBER":"977790","EVENT_NO":"4225648","INSPECTION_BEGIN_DT":"02/04/2002","INSPECTION_END_DT":"02/05/2002","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2002-02-04"},{"SOURCE_ROW_NUMBER":"10123","EVENT_NO":"4226151","INSPECTION_BEGIN_DT":"11/19/2001","INSPECTION_END_DT":"11/21/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"32","SUM_TOTAL_ON_SITE_HOURS":"27","sourceDate":"2001-11-19"},{"SOURCE_ROW_NUMBER":"59994","EVENT_NO":"4226237","INSPECTION_BEGIN_DT":"09/06/2001","INSPECTION_END_DT":"09/13/2001","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"42211","EVENT_NO":"4226236","INSPECTION_BEGIN_DT":"09/06/2001","INSPECTION_END_DT":"09/11/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2001-09-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":7771,"employees":19,"production":31604},"2002-Q3":{"hours":21808,"employees":30,"production":91959},"2002-Q2":{"hours":21954,"employees":33,"production":85484},"2002-Q1":{"hours":20999,"employees":35,"production":153016},"2001-Q4":{"hours":24133,"employees":35,"production":144280},"2001-Q3":{"hours":10834,"employees":18,"production":45442},"2001-Q2":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":34967,"employees":27,"production":189722},"2002":{"hours":72532,"employees":29,"production":362063}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2001-09-06","lastDate":"2002-05-21","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":408,"pelDoseTotal":123},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"74204","EVENT_NO":"4232661","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"52","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"74203","EVENT_NO":"4232661","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"053","ACT_DOSE_85":"28","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"74202","EVENT_NO":"4232661","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"70","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"74201","EVENT_NO":"4232661","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"73","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"74200","EVENT_NO":"4232661","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"28","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"74199","EVENT_NO":"4226236","SURVEY_DATE":"09/06/2001","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"26","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"74198","EVENT_NO":"4226236","SURVEY_DATE":"09/06/2001","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"71","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"74197","EVENT_NO":"4226236","SURVEY_DATE":"09/06/2001","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"053","ACT_DOSE_85":"10","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"74196","EVENT_NO":"4226236","SURVEY_DATE":"09/06/2001","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"25","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"74195","EVENT_NO":"4226236","SURVEY_DATE":"09/06/2001","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"25","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2001-09-06"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":3,"firstDate":"2001-11-19","lastDate":"2002-10-22","metrics":{"ss":0,"amountDue":165,"contested":0,"amountPaid":165,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":165},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"989696","VIOLATION_NO":"7472254","VIOLATION_ISSUE_DT":"10/22/2002","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/22/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"989695","VIOLATION_NO":"7472426","VIOLATION_ISSUE_DT":"04/16/2002","SIG_SUB":"N","PART_SECTION":"77.400(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/17/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-04-16"},{"SOURCE_ROW_NUMBER":"989697","VIOLATION_NO":"7472376","VIOLATION_ISSUE_DT":"11/19/2001","SIG_SUB":"N","PART_SECTION":"77.1302(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/19/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-19"}]}],"safety":{"href":"/api/v1/mines/1518374/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518374/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","heading":"Vehicles used to transport explosives.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-N/section-77.1302","part":"77","subchapter":"O","subpart":"N","id":"77.1302","citation":"30 CFR 77.1302","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518374","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}