{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518301","name":"Moose No. 1","status":"Abandoned and Sealed","status_date":"2005-04-28","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Pikeville","operator_id":"P23577","operator_name":"Banner  Inc.","controller_id":"C13654","controller_name":"Anthony  McPeek","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.415,"longitude":-82.568333},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":878},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518301","name":"Moose No. 1"},"operator":{"type":"operator","id":"P23577","name":"Banner  Inc."},"controller":{"type":"controller","id":"C13654","name":"Anthony  McPeek"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13654","name":"Anthony  McPeek"},"object":{"type":"mine","id":"1518301","name":"Moose No. 1"},"validFrom":"1996-11-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518301|C13654|1996-11-26|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15585","name":"Iracoal Incorporated"},"object":{"type":"mine","id":"1518301","name":"Moose No. 1"},"validFrom":"1997-01-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518301|C15585|1997-01-31|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23722","name":"Lodestar Energy Inc"},"object":{"type":"mine","id":"1518301","name":"Moose No. 1"},"validFrom":"2000-11-01","validTo":"2001-02-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518301|P23722|2000-11-01|2001-02-01"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15585","name":"Iracoal Incorporated"},"object":{"type":"operator","id":"P23722","name":"Lodestar Energy Inc"},"validFrom":"2000-11-01","validTo":"2001-02-01","current":false,"derived":true,"evidenceMineId":"1518301","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518301|P23722|2000-11-01|C15585|1997-01-31|96283"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23577","name":"Banner  Inc."},"object":{"type":"mine","id":"1518301","name":"Moose No. 1"},"validFrom":"2001-02-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518301|P23577|2001-02-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13654","name":"Anthony  McPeek"},"object":{"type":"operator","id":"P23577","name":"Banner  Inc."},"validFrom":"2001-02-02","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518301","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518301|P23577|2001-02-02|C13654|1996-11-26|90714"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":12,"firstDate":"2001-10-10","lastDate":"2004-11-19","metrics":{"daysLost":331,"injuries":11,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"147700","DOCUMENT_NO":"220043290015","ACCIDENT_DT":"11/19/2004","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was loading bolter supplies, moved plate pallet, and cut band on the pallet and the band flew up and hit him in the left eye.  (EE WAS NOT WEARING SAFETY GLASSES.)","sourceDate":"2004-11-19"},{"SOURCE_ROW_NUMBER":"10057","DOCUMENT_NO":"220040410020","ACCIDENT_DT":"02/02/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"1","DAYS_LOST":"19","NARRATIVE":"EE WAS CHANGING A WIRE ON A BUGGY WHEN THE BUGGYSTARTED AND RAN UP HIS LEFT LEG AND JAMMED HIS LEG UP INTO HIS BACK AND LEFT SIDE.","sourceDate":"2004-02-02"},{"SOURCE_ROW_NUMBER":"250980","DOCUMENT_NO":"220033440005","ACCIDENT_DT":"12/02/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"EE WAS HAULING COAL WITH S-CAR WHEN HE RAN OVER A ROCK IN THE ROADWAY. THE CANOPY HIT THE MINE ROOF, THROWING THE OPERATOR OUT OF THE CAR, FALLING ON HIS LEFT HIP.","sourceDate":"2003-12-02"},{"SOURCE_ROW_NUMBER":"87436","DOCUMENT_NO":"220032590033","ACCIDENT_DT":"09/08/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE WAS USING A HAND DRILL TO ANCHOR TAIL PIECE AND WHILE HE WAS CLEANING DUST FROM THE HOLE HE CAUGHT HIS GLOVE AND TWISTED HIS RIGHT HAND, INJURING HIS WRIST.","sourceDate":"2003-09-08"},{"SOURCE_ROW_NUMBER":"250979","DOCUMENT_NO":"220031420009","ACCIDENT_DT":"05/20/2003","DEGREE_INJURY":"NO VALUE FOUND","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"THE FOREMAN HAD SOME SUSPICION AS TO THE EE REACTIONS WHEN HE CONFRONTED THE EE THE EE STATED THAT HE WANTS TO QUIT. THE FOREMAN STARTED OUT OF THE MINE & THE EE SAID HE HURT HIS BACK WHILE ON THE RIDE OUT.","sourceDate":"2003-05-20"},{"SOURCE_ROW_NUMBER":"1461","DOCUMENT_NO":"220030910017","ACCIDENT_DT":"03/17/2003","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE WAS ATTEMPTING TO REMOVE A BROKEN SHEAR PIN FROM FEEDER WHEN HE UNINTENTIONALLY STRUCK PUNCH BETWEEN SHEAR WHEELS AND THE PUNCH BROKE, HITTING EMPLOYEE IN THE MOUTH.","sourceDate":"2003-03-17"},{"SOURCE_ROW_NUMBER":"139060","DOCUMENT_NO":"220022250030","ACCIDENT_DT":"08/09/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Contact with electrical current","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"THE EMPLOYEE WAS TROUBLE SHOOTING ON THE PANEL OF A SHUTTLE CAR 480 V WHEN A PART OF HIS BODY CONTACTED AN ENERGISED PART. A FAULTY DIODE WAS PREVENTING THE BRAKER FROM ENERGING. THE EMPLOYEE WAS TAKEN TO PIKEVILLE HOSPITAL FOR TREATMENT AND OBSERVATION, RELEASED TO RETURN TO WORK.","sourceDate":"2002-08-09"},{"SOURCE_ROW_NUMBER":"160615","DOCUMENT_NO":"220021820002","ACCIDENT_DT":"06/26/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"74","NARRATIVE":"EE WAS BOLTING TOP WHEN A DRAW ROCK FELL, STRIKING HIS FINGER.","sourceDate":"2002-06-26"},{"SOURCE_ROW_NUMBER":"173476","DOCUMENT_NO":"220020950017","ACCIDENT_DT":"04/01/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Motorman, Motor person, Swamper, Switchman, Locomotive operator","NO_INJURIES":"1","DAYS_LOST":"104","NARRATIVE":"STRAINED LOWER BACK LIFT AT BELT AND STRUCTURE.","sourceDate":"2002-04-01"},{"SOURCE_ROW_NUMBER":"268093","DOCUMENT_NO":"220020880003","ACCIDENT_DT":"03/26/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"38","NARRATIVE":"EE WAS USING ROOF BOLTER AND IT SMASHED HIS RT. LITTLE FINGER.","sourceDate":"2002-03-26"},{"SOURCE_ROW_NUMBER":"74460","DOCUMENT_NO":"220020880001","ACCIDENT_DT":"03/25/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"69","NARRATIVE":"EE WAS PULLING CURTAIN AROUND BUGGY WHEEL, FELT PAIN IN LOWER BACK.","sourceDate":"2002-03-25"},{"SOURCE_ROW_NUMBER":"246686","DOCUMENT_NO":"220012880022","ACCIDENT_DT":"10/10/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"1L OFF MAIN AT 171, HILL SEAM DROP OUT. ABOUT 45' THICK DURING A TRIPLE A INSPECTION. THE FALL WAS INVESTIGATED, WAS TIMBERED AND DANGERED OFF. 10-10-01.","sourceDate":"2001-10-10"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2005-04-28","lastDate":"2005-04-28","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":167,"firstDate":"2001-03-27","lastDate":"2005-01-11","metrics":{"ss":63,"delinquent":167,"recentRows":0,"paidPenalty":16104,"proposedPenalty":17054,"currentAssessment":16104},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"985513","VIOLATION_NO":"7407287","ISSUE_DT":"01/11/2005","CFR_STANDARD_CD":"77.410(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"985512","VIOLATION_NO":"7407286","ISSUE_DT":"01/11/2005","CFR_STANDARD_CD":"75.1103-4(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"983318","VIOLATION_NO":"7415091","ISSUE_DT":"12/28/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"983317","VIOLATION_NO":"7415090","ISSUE_DT":"12/28/2004","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"203.00","CURRENT_ASSESSMENT_AMT":"110.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"983316","VIOLATION_NO":"7415089","ISSUE_DT":"12/28/2004","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"983315","VIOLATION_NO":"7415088","ISSUE_DT":"12/28/2004","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"983314","VIOLATION_NO":"7415087","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"70.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"983313","VIOLATION_NO":"7415086","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"354.00","CURRENT_ASSESSMENT_AMT":"354.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"983312","VIOLATION_NO":"7415085","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"75.360(e)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"324.00","CURRENT_ASSESSMENT_AMT":"160.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"983311","VIOLATION_NO":"7415084","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"983310","VIOLATION_NO":"7415080","ISSUE_DT":"12/06/2004","CFR_STANDARD_CD":"77.404","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"247.00","CURRENT_ASSESSMENT_AMT":"247.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-06"},{"SOURCE_ROW_NUMBER":"983309","VIOLATION_NO":"7415079","ISSUE_DT":"12/06/2004","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-06"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":21,"firstDate":"2003-12-16","lastDate":"2005-06-22","metrics":{"appeals":0,"decisions":21,"recentRows":0,"decisionPenalty":2824,"originalPenalty":3951},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"187284","VIOLATION_NO":"7415090","DOCKET_NO":"KENT 2005-153","DECISION_DT":"06/22/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"203.00","DECISION_PENALTY_AMT":"110.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-06-22"},{"SOURCE_ROW_NUMBER":"187079","VIOLATION_NO":"7415087","DOCKET_NO":"KENT 2005-153","DECISION_DT":"06/22/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"154.00","DECISION_PENALTY_AMT":"70.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-06-22"},{"SOURCE_ROW_NUMBER":"186872","VIOLATION_NO":"7415085","DOCKET_NO":"KENT 2005-153","DECISION_DT":"06/22/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"324.00","DECISION_PENALTY_AMT":"160.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-06-22"},{"SOURCE_ROW_NUMBER":"186253","VIOLATION_NO":"7413991","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-04-14"},{"SOURCE_ROW_NUMBER":"186252","VIOLATION_NO":"7407918","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"140.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-04-14"},{"SOURCE_ROW_NUMBER":"186097","VIOLATION_NO":"7413985","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-04-14"},{"SOURCE_ROW_NUMBER":"186096","VIOLATION_NO":"7413983","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-04-14"},{"SOURCE_ROW_NUMBER":"185879","VIOLATION_NO":"7407920","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-04-14"},{"SOURCE_ROW_NUMBER":"185878","VIOLATION_NO":"7407917","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"165.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-04-14"},{"SOURCE_ROW_NUMBER":"185846","VIOLATION_NO":"7413984","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-04-14"},{"SOURCE_ROW_NUMBER":"3300","VIOLATION_NO":"7407912","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"165.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-04-14"},{"SOURCE_ROW_NUMBER":"3299","VIOLATION_NO":"7407867","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-04-14"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":307,"firstDate":"2001-04-23","lastDate":"2005-03-29","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":8,"validSamples":299,"maxConcentration":5.416,"concentrationTotal":112.501},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"806619","CASS_NUM":"50789246","SMP_TAKEN_DT":"3/29/2005","CONC":".132","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-29"},{"SOURCE_ROW_NUMBER":"1376049","CASS_NUM":"57581146","SMP_TAKEN_DT":"2/17/2005","CONC":".211","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"1120291","CASS_NUM":"57581115","SMP_TAKEN_DT":"2/17/2005","CONC":".239","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"481165","CASS_NUM":"57581170","SMP_TAKEN_DT":"2/17/2005","CONC":".226","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"470124","CASS_NUM":"57581083","SMP_TAKEN_DT":"2/17/2005","CONC":".267","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"209856","CASS_NUM":"57581070","SMP_TAKEN_DT":"2/17/2005","CONC":".293","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"53306","CASS_NUM":"57581061","SMP_TAKEN_DT":"2/17/2005","CONC":".233","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"40613","CASS_NUM":"50767609","SMP_TAKEN_DT":"2/11/2005","CONC":".063","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-11"},{"SOURCE_ROW_NUMBER":"743383","CASS_NUM":"50767586","SMP_TAKEN_DT":"2/10/2005","CONC":".363","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-10"},{"SOURCE_ROW_NUMBER":"176450","CASS_NUM":"50767597","SMP_TAKEN_DT":"2/9/2005","CONC":".283","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-09"},{"SOURCE_ROW_NUMBER":"1194018","CASS_NUM":"50767600","SMP_TAKEN_DT":"2/8/2005","CONC":".904","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"241499","CASS_NUM":"50767620","SMP_TAKEN_DT":"2/7/2005","CONC":".304","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-07"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":25,"firstDate":"2003-07-09","lastDate":"2004-10-13","metrics":{"linkedIssuances":25},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":20,"firstDate":"2004-07-22","lastDate":"2004-12-28","metrics":{"decisions":20,"ssChanged":2,"recentRows":0,"decisionPenalty":2764,"proposedPenalty":3630},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"699","CITATION_NO":"7415090","CITATION_ISSUE_DT":"12/28/2004","DOCKET_NO":"KENT 2005-153","DECISION_DT":"06/22/2005","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"203.00","DECISION_PENALTY_AMT":"110.00","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"396453","CITATION_NO":"7415085","CITATION_ISSUE_DT":"12/27/2004","DOCKET_NO":"KENT 2005-153","DECISION_DT":"06/22/2005","CFR_STANDARD_CODE":"75.360(e)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"324.00","DECISION_PENALTY_AMT":"160.00","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"57035","CITATION_NO":"7415087","CITATION_ISSUE_DT":"12/27/2004","DOCKET_NO":"KENT 2005-153","DECISION_DT":"06/22/2005","CFR_STANDARD_CODE":"75.601-1","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"154.00","DECISION_PENALTY_AMT":"70.00","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"57733","CITATION_NO":"7413991","CITATION_ISSUE_DT":"09/02/2004","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","CFR_STANDARD_CODE":"75.220(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","sourceDate":"2004-09-02"},{"SOURCE_ROW_NUMBER":"170709","CITATION_NO":"7413989","CITATION_ISSUE_DT":"08/31/2004","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","CFR_STANDARD_CODE":"75.1103","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"113846","CITATION_NO":"7413985","CITATION_ISSUE_DT":"08/30/2004","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","CFR_STANDARD_CODE":"75.511","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","sourceDate":"2004-08-30"},{"SOURCE_ROW_NUMBER":"396348","CITATION_NO":"7413984","CITATION_ISSUE_DT":"08/25/2004","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","CFR_STANDARD_CODE":"75.360(b)(3)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"340552","CITATION_NO":"7413983","CITATION_ISSUE_DT":"08/25/2004","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","CFR_STANDARD_CODE":"75.203(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"340332","CITATION_NO":"7407918","CITATION_ISSUE_DT":"08/25/2004","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","CFR_STANDARD_CODE":"77.400(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"140.00","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"339737","CITATION_NO":"7413982","CITATION_ISSUE_DT":"08/25/2004","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","CFR_STANDARD_CODE":"75.208","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"177.00","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"283632","CITATION_NO":"7407920","CITATION_ISSUE_DT":"08/25/2004","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","CFR_STANDARD_CODE":"77.513","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"60.00","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"227550","CITATION_NO":"7407917","CITATION_ISSUE_DT":"08/25/2004","DOCKET_NO":"KENT 2005-54","DECISION_DT":"04/14/2005","CFR_STANDARD_CODE":"77.400(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"165.00","sourceDate":"2004-08-25"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":13,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2000-11-01","lastDate":"2001-02-02","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":54,"firstDate":"2001-02-26","lastDate":"2005-04-25","metrics":{"inspectors":76,"recentRows":0,"onSiteHours":1124,"inspectionHours":1637.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"305785","EVENT_NO":"4178778","INSPECTION_BEGIN_DT":"04/25/2005","INSPECTION_END_DT":"04/25/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-04-25"},{"SOURCE_ROW_NUMBER":"462207","EVENT_NO":"4179070","INSPECTION_BEGIN_DT":"03/25/2005","INSPECTION_END_DT":"03/25/2005","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-03-25"},{"SOURCE_ROW_NUMBER":"152156","EVENT_NO":"4178765","INSPECTION_BEGIN_DT":"02/17/2005","INSPECTION_END_DT":"02/17/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"964269","EVENT_NO":"4177897","INSPECTION_BEGIN_DT":"01/10/2005","INSPECTION_END_DT":"01/10/2005","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"456937","EVENT_NO":"4178758","INSPECTION_BEGIN_DT":"01/05/2005","INSPECTION_END_DT":"01/25/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2005-01-05"},{"SOURCE_ROW_NUMBER":"419503","EVENT_NO":"4178757","INSPECTION_BEGIN_DT":"01/05/2005","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"49","SUM_TOTAL_ON_SITE_HOURS":"34","sourceDate":"2005-01-05"},{"SOURCE_ROW_NUMBER":"738581","EVENT_NO":"4177885","INSPECTION_BEGIN_DT":"10/19/2004","INSPECTION_END_DT":"10/19/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-10-19"},{"SOURCE_ROW_NUMBER":"1052135","EVENT_NO":"4177881","INSPECTION_BEGIN_DT":"10/12/2004","INSPECTION_END_DT":"12/29/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"74.5","SUM_TOTAL_ON_SITE_HOURS":"63.5","sourceDate":"2004-10-12"},{"SOURCE_ROW_NUMBER":"627834","EVENT_NO":"4183392","INSPECTION_BEGIN_DT":"09/21/2004","INSPECTION_END_DT":"09/23/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2004-09-21"},{"SOURCE_ROW_NUMBER":"1142304","EVENT_NO":"4178009","INSPECTION_BEGIN_DT":"09/09/2004","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2004-09-09"},{"SOURCE_ROW_NUMBER":"104098","EVENT_NO":"4178008","INSPECTION_BEGIN_DT":"07/20/2004","INSPECTION_END_DT":"07/20/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2004-07-20"},{"SOURCE_ROW_NUMBER":"730246","EVENT_NO":"4178005","INSPECTION_BEGIN_DT":"07/09/2004","INSPECTION_END_DT":"09/21/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"132.5","SUM_TOTAL_ON_SITE_HOURS":"110.5","sourceDate":"2004-07-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":36,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005-Q2":{"hours":2426,"employees":17,"production":33},"2005-Q1":{"hours":10425,"employees":22,"production":30644},"2004-Q4":{"hours":13107,"employees":20,"production":41886},"2004-Q3":{"hours":14286,"employees":23,"production":49729},"2004-Q2":{"hours":15291,"employees":23,"production":73428},"2004-Q1":{"hours":14577,"employees":25,"production":69861},"2003-Q4":{"hours":15514,"employees":29,"production":61116},"2003-Q3":{"hours":14542,"employees":28,"production":71849},"2003-Q2":{"hours":13460,"employees":22,"production":70962},"2003-Q1":{"hours":11795,"employees":13,"production":64881},"2002-Q4":{"hours":12514,"employees":22,"production":50346},"2002-Q3":{"hours":13905,"employees":27,"production":63338}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":30412,"employees":14,"production":140132},"2002":{"hours":52291,"employees":26,"production":236467},"2003":{"hours":55311,"employees":24,"production":268808},"2004":{"hours":57261,"employees":23,"production":234904},"2005":{"hours":12851,"employees":20,"production":30677}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2002-09-19","lastDate":"2004-02-18","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":1103,"pelDoseTotal":754},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"72064","EVENT_NO":"4186219","SURVEY_DATE":"02/18/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"31","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2004-02-18"},{"SOURCE_ROW_NUMBER":"72063","EVENT_NO":"4186219","SURVEY_DATE":"02/18/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2004-02-18"},{"SOURCE_ROW_NUMBER":"72062","EVENT_NO":"4186219","SURVEY_DATE":"02/18/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"63","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2004-02-18"},{"SOURCE_ROW_NUMBER":"72061","EVENT_NO":"4186219","SURVEY_DATE":"02/18/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"109","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2004-02-18"},{"SOURCE_ROW_NUMBER":"72060","EVENT_NO":"4186219","SURVEY_DATE":"02/18/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"70","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2004-02-18"},{"SOURCE_ROW_NUMBER":"72059","EVENT_NO":"4185080","SURVEY_DATE":"06/04/2003","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"34","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2003-06-04"},{"SOURCE_ROW_NUMBER":"72058","EVENT_NO":"4185080","SURVEY_DATE":"06/04/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"139","PEL_DOSE_90":"97","SURVEY_TYPE":"I","sourceDate":"2003-06-04"},{"SOURCE_ROW_NUMBER":"72057","EVENT_NO":"4185080","SURVEY_DATE":"06/04/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"246","PEL_DOSE_90":"195","SURVEY_TYPE":"I","sourceDate":"2003-06-04"},{"SOURCE_ROW_NUMBER":"72056","EVENT_NO":"4185080","SURVEY_DATE":"06/04/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"050","ACT_DOSE_85":"89","PEL_DOSE_90":"66","SURVEY_TYPE":"I","sourceDate":"2003-06-04"},{"SOURCE_ROW_NUMBER":"72055","EVENT_NO":"4185080","SURVEY_DATE":"06/04/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2003-06-04"},{"SOURCE_ROW_NUMBER":"72054","EVENT_NO":"4163081","SURVEY_DATE":"09/19/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"22","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2002-09-19"},{"SOURCE_ROW_NUMBER":"72053","EVENT_NO":"4163081","SURVEY_DATE":"09/19/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"24","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2002-09-19"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":19,"firstDate":"2001-06-27","lastDate":"2004-10-19","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":15.9,"validSamples":16,"quartzPctTotal":108.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"72673","CASSETTE_NO":"57581529","SAMPLE_DT":"10/19/2004","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-10-19"},{"SOURCE_ROW_NUMBER":"90887","CASSETTE_NO":"50743185","SAMPLE_DT":"08/05/2004","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"OVERSIZE PARTICLES","sourceDate":"2004-08-05"},{"SOURCE_ROW_NUMBER":"72637","CASSETTE_NO":"50743184","SAMPLE_DT":"08/05/2004","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"OVERSIZE PARTICLES","sourceDate":"2004-08-05"},{"SOURCE_ROW_NUMBER":"83970","CASSETTE_NO":"57531642","SAMPLE_DT":"07/20/2004","QUARTZ_PCT":"12.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-07-20"},{"SOURCE_ROW_NUMBER":"40494","CASSETTE_NO":"57531623","SAMPLE_DT":"07/20/2004","QUARTZ_PCT":"15.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-07-20"},{"SOURCE_ROW_NUMBER":"125465","CASSETTE_NO":"50745003","SAMPLE_DT":"05/24/2004","QUARTZ_PCT":"00.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-24"},{"SOURCE_ROW_NUMBER":"73120","CASSETTE_NO":"57531469","SAMPLE_DT":"05/19/2004","QUARTZ_PCT":"05.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-19"},{"SOURCE_ROW_NUMBER":"98330","CASSETTE_NO":"50733284","SAMPLE_DT":"05/03/2004","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-03"},{"SOURCE_ROW_NUMBER":"131984","CASSETTE_NO":"57521673","SAMPLE_DT":"02/18/2004","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-18"},{"SOURCE_ROW_NUMBER":"150199","CASSETTE_NO":"57479792","SAMPLE_DT":"08/06/2003","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-08-06"},{"SOURCE_ROW_NUMBER":"49893","CASSETTE_NO":"50668553","SAMPLE_DT":"02/12/2003","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-02-12"},{"SOURCE_ROW_NUMBER":"73011","CASSETTE_NO":"57390179","SAMPLE_DT":"03/20/2002","QUARTZ_PCT":"08.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":170,"firstDate":"2001-03-27","lastDate":"2005-01-11","metrics":{"ss":63,"amountDue":16104,"contested":20,"amountPaid":16104,"recentRows":0,"section104d":0,"unterminated":1,"proposedPenalty":17054},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"976072","VIOLATION_NO":"7407287","VIOLATION_ISSUE_DT":"01/11/2005","SIG_SUB":"N","PART_SECTION":"77.410(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/25/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"976071","VIOLATION_NO":"7407286","VIOLATION_ISSUE_DT":"01/11/2005","SIG_SUB":"N","PART_SECTION":"75.1103-4(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/25/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"976227","VIOLATION_NO":"7415092","VIOLATION_ISSUE_DT":"12/28/2004","PART_SECTION":"75.503","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"12/28/2004","CONTESTED_IND":"N","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"976226","VIOLATION_NO":"7415091","VIOLATION_ISSUE_DT":"12/28/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/28/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"976225","VIOLATION_NO":"7415090","VIOLATION_ISSUE_DT":"12/28/2004","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/28/2004","PROPOSED_PENALTY":"203","AMOUNT_DUE":"110","AMOUNT_PAID":"110","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2005-153","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"976224","VIOLATION_NO":"7415089","VIOLATION_ISSUE_DT":"12/28/2004","SIG_SUB":"Y","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/10/2005","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"976223","VIOLATION_NO":"7415088","VIOLATION_ISSUE_DT":"12/28/2004","SIG_SUB":"Y","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/10/2005","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"976222","VIOLATION_NO":"7415087","VIOLATION_ISSUE_DT":"12/27/2004","SIG_SUB":"Y","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/27/2004","PROPOSED_PENALTY":"154","AMOUNT_DUE":"70","AMOUNT_PAID":"70","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2005-153","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"976221","VIOLATION_NO":"7415086","VIOLATION_ISSUE_DT":"12/27/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"354","AMOUNT_DUE":"354","AMOUNT_PAID":"354","CONTESTED_IND":"N","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"976220","VIOLATION_NO":"7415085","VIOLATION_ISSUE_DT":"12/27/2004","SIG_SUB":"Y","PART_SECTION":"75.360(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/27/2004","PROPOSED_PENALTY":"324","AMOUNT_DUE":"160","AMOUNT_PAID":"160","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2005-153","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"976219","VIOLATION_NO":"7415084","VIOLATION_ISSUE_DT":"12/27/2004","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/28/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"976218","VIOLATION_NO":"7415080","VIOLATION_ISSUE_DT":"12/06/2004","SIG_SUB":"Y","PART_SECTION":"77.404","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/09/2004","PROPOSED_PENALTY":"247","AMOUNT_DUE":"247","AMOUNT_PAID":"247","CONTESTED_IND":"N","sourceDate":"2004-12-06"}]}],"safety":{"href":"/api/v1/mines/1518301/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518301/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518301","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}