{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518287","name":"Spring Branch #2","status":"Abandoned and Sealed","status_date":"2003-05-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Letcher","nearest_town":"Premium","operator_id":"P24465","operator_name":"Cook and Sons Mining, Inc.","controller_id":"C04802","controller_name":"Michael K  Cook; Randy A  Cook","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.156944,"longitude":-82.908611},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":373},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518287","name":"Spring Branch #2"},"operator":{"type":"operator","id":"P24465","name":"Cook and Sons Mining, Inc."},"controller":{"type":"controller","id":"C04802","name":"Michael K  Cook; Randy A  Cook"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C08472","name":"Allen G  Stump et al"},"object":{"type":"mine","id":"1518287","name":"Spring Branch #2"},"validFrom":"1993-06-04","validTo":"2001-03-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|C08472|1993-06-04|2001-03-07"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22376","name":"Altec Energy Inc"},"object":{"type":"mine","id":"1518287","name":"Spring Branch #2"},"validFrom":"2000-10-01","validTo":"2001-03-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|P22376|2000-10-01|2001-03-07"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C08472","name":"Allen G  Stump et al"},"object":{"type":"operator","id":"P22376","name":"Altec Energy Inc"},"validFrom":"2000-10-01","validTo":"2001-03-07","current":false,"derived":true,"evidenceMineId":"1518287","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|P22376|2000-10-01|C08472|1993-06-04|77388"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C04802","name":"Michael K  Cook et al"},"object":{"type":"mine","id":"1518287","name":"Spring Branch #2"},"validFrom":"2000-11-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|C04802|2000-11-10|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24465","name":"Cook & Sons Mining Inc"},"object":{"type":"mine","id":"1518287","name":"Spring Branch #2"},"validFrom":"2001-03-08","validTo":"2002-07-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|P24465|2001-03-08|2002-07-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C04802","name":"Michael K  Cook et al"},"object":{"type":"operator","id":"P24465","name":"Cook & Sons Mining Inc"},"validFrom":"2001-03-08","validTo":"2002-07-08","current":false,"derived":true,"evidenceMineId":"1518287","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|P24465|2001-03-08|C04802|2000-11-10|66820"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C04802","name":"Randy A  Cook et al"},"object":{"type":"operator","id":"P24465","name":"Cook & Sons Mining Inc"},"validFrom":"2001-03-08","validTo":"2002-07-08","current":false,"derived":true,"evidenceMineId":"1518287","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|P24465|2001-03-08|C04802|2000-11-10|66821"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050592","name":"Rickco, Inc."},"object":{"type":"mine","id":"1518287","name":"Spring Branch #2"},"validFrom":"2002-07-09","validTo":"2003-04-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|0050592|2002-07-09|2003-04-06"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C09512","name":"Rickey  Niece"},"object":{"type":"mine","id":"1518287","name":"Spring Branch #2"},"validFrom":"2002-07-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|C09512|2002-07-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C09512","name":"Rickey  Niece"},"object":{"type":"operator","id":"0050592","name":"Rickco, Inc."},"validFrom":"2002-07-09","validTo":"2003-04-06","current":false,"derived":true,"evidenceMineId":"1518287","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|0050592|2002-07-09|C09512|2002-07-09|79852"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24465","name":"Cook and Sons Mining, Inc."},"object":{"type":"mine","id":"1518287","name":"Spring Branch #2"},"validFrom":"2003-04-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|P24465|2003-04-07|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C04802","name":"Michael K  Cook et al"},"object":{"type":"operator","id":"P24465","name":"Cook and Sons Mining, Inc."},"validFrom":"2003-04-07","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518287","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|P24465|2003-04-07|C04802|2000-11-10|66822"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C04802","name":"Randy A  Cook et al"},"object":{"type":"operator","id":"P24465","name":"Cook and Sons Mining, Inc."},"validFrom":"2003-04-07","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518287","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518287|P24465|2003-04-07|C04802|2000-11-10|66823"}}],"coverage":{"historyRecords":6,"edgeCount":13,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":4,"firstDate":"2002-01-08","lastDate":"2002-04-11","metrics":{"daysLost":31,"injuries":4,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"272401","DOCUMENT_NO":"220021060033","ACCIDENT_DT":"04/11/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"21","NARRATIVE":"EMPLOYEE WAS BOLTING TOP AT THE TIME OF THE ACCIDENT. HE WAS SWINGING BOOM TO PUT UP MIDDLE BOLT WHEN HE LET THE BOOM DOWN ON HIS LEFT KNEE.","sourceDate":"2002-04-11"},{"SOURCE_ROW_NUMBER":"272400","DOCUMENT_NO":"220020310007","ACCIDENT_DT":"01/26/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"WHILE PUSHING ON LEVER TO LOWER CANOPY HAD SLIPPED OFF AND STRIKING THE DRILL POT SLIDE LEVER RUNNING THE DRILL POT OUT MASHED THE FINGER OF HIS LEFT HAND THAT WAS RESTING ON THE DRILL POT.","sourceDate":"2002-01-26"},{"SOURCE_ROW_NUMBER":"14370","DOCUMENT_NO":"220020310002","ACCIDENT_DT":"01/21/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"ROOF BOLTER STARTED CABLE REEL AND CABLE HIT RIGHT LEG CAUSING HIM TO FALL BUMPING HEAD BRUISING KNEE AND HEAD AND NECK.","sourceDate":"2002-01-21"},{"SOURCE_ROW_NUMBER":"233735","DOCUMENT_NO":"220020290015","ACCIDENT_DT":"01/08/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"PULLING ON MINER CABLE FELT PAIN IN LOWER BACK.","sourceDate":"2002-01-08"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2003-05-16","lastDate":"2003-05-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":112,"firstDate":"2000-11-21","lastDate":"2003-04-23","metrics":{"ss":63,"delinquent":112,"recentRows":0,"paidPenalty":2875,"proposedPenalty":11658,"currentAssessment":11658},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"989279","VIOLATION_NO":"7399041","ISSUE_DT":"04/23/2003","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-23"},{"SOURCE_ROW_NUMBER":"1011346","VIOLATION_NO":"7389700","ISSUE_DT":"04/01/2003","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-01"},{"SOURCE_ROW_NUMBER":"1011345","VIOLATION_NO":"7389699","ISSUE_DT":"04/01/2003","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-01"},{"SOURCE_ROW_NUMBER":"1011344","VIOLATION_NO":"7389698","ISSUE_DT":"04/01/2003","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2041.00","CURRENT_ASSESSMENT_AMT":"2041.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-01"},{"SOURCE_ROW_NUMBER":"956701","VIOLATION_NO":"7398886","ISSUE_DT":"02/28/2003","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"161.00","CURRENT_ASSESSMENT_AMT":"161.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-02-28"},{"SOURCE_ROW_NUMBER":"956700","VIOLATION_NO":"7398882","ISSUE_DT":"02/19/2003","CFR_STANDARD_CD":"75.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"113.00","CURRENT_ASSESSMENT_AMT":"113.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-02-19"},{"SOURCE_ROW_NUMBER":"956699","VIOLATION_NO":"7398768","ISSUE_DT":"01/30/2003","CFR_STANDARD_CD":"75.310(a)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-30"},{"SOURCE_ROW_NUMBER":"956698","VIOLATION_NO":"7398767","ISSUE_DT":"01/30/2003","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"76.00","CURRENT_ASSESSMENT_AMT":"76.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-30"},{"SOURCE_ROW_NUMBER":"956697","VIOLATION_NO":"7398766","ISSUE_DT":"01/30/2003","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"69.00","CURRENT_ASSESSMENT_AMT":"69.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-30"},{"SOURCE_ROW_NUMBER":"956696","VIOLATION_NO":"7398765","ISSUE_DT":"01/30/2003","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"104.00","CURRENT_ASSESSMENT_AMT":"104.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-30"},{"SOURCE_ROW_NUMBER":"956695","VIOLATION_NO":"7398763","ISSUE_DT":"01/30/2003","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"69.00","CURRENT_ASSESSMENT_AMT":"69.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-30"},{"SOURCE_ROW_NUMBER":"956694","VIOLATION_NO":"7398762","ISSUE_DT":"01/30/2003","CFR_STANDARD_CD":"77.208(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"76.00","CURRENT_ASSESSMENT_AMT":"76.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-30"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":44,"firstDate":"2002-01-14","lastDate":"2003-03-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":25,"validSamples":19,"maxConcentration":6.698,"concentrationTotal":31.725},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"862959","CASS_NUM":"50694044","SMP_TAKEN_DT":"3/25/2003","CONC":".471","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-03-25"},{"SOURCE_ROW_NUMBER":"205723","CASS_NUM":"50694016","SMP_TAKEN_DT":"3/24/2003","CONC":".257","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-03-24"},{"SOURCE_ROW_NUMBER":"913513","CASS_NUM":"57447097","SMP_TAKEN_DT":"12/31/2002","CONC":".23","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-31"},{"SOURCE_ROW_NUMBER":"623407","CASS_NUM":"57447093","SMP_TAKEN_DT":"12/31/2002","CONC":"0","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-31"},{"SOURCE_ROW_NUMBER":"310377","CASS_NUM":"57447115","SMP_TAKEN_DT":"12/31/2002","CONC":".052","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-31"},{"SOURCE_ROW_NUMBER":"285981","CASS_NUM":"57447120","SMP_TAKEN_DT":"12/31/2002","CONC":"0","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-31"},{"SOURCE_ROW_NUMBER":"115155","CASS_NUM":"57447114","SMP_TAKEN_DT":"12/31/2002","CONC":".126","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-31"},{"SOURCE_ROW_NUMBER":"104241","CASS_NUM":"57447124","SMP_TAKEN_DT":"12/31/2002","CONC":".035","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-31"},{"SOURCE_ROW_NUMBER":"1389612","CASS_NUM":"50685304","SMP_TAKEN_DT":"12/30/2002","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-30"},{"SOURCE_ROW_NUMBER":"857282","CASS_NUM":"50685316","SMP_TAKEN_DT":"12/27/2002","CONC":".081","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-27"},{"SOURCE_ROW_NUMBER":"88926","CASS_NUM":"50685332","SMP_TAKEN_DT":"12/27/2002","CONC":".225","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-27"},{"SOURCE_ROW_NUMBER":"675925","CASS_NUM":"50685323","SMP_TAKEN_DT":"12/20/2002","CONC":"2.303","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-12-20"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":21,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"2000-10-01","lastDate":"2003-04-07","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":41,"firstDate":"2000-10-30","lastDate":"2003-04-02","metrics":{"inspectors":70,"recentRows":0,"onSiteHours":645.25,"inspectionHours":1075,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1032114","EVENT_NO":"4180061","INSPECTION_BEGIN_DT":"04/02/2003","INSPECTION_END_DT":"04/30/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25","SUM_TOTAL_ON_SITE_HOURS":"15.5","sourceDate":"2003-04-02"},{"SOURCE_ROW_NUMBER":"630315","EVENT_NO":"4185272","INSPECTION_BEGIN_DT":"04/01/2003","INSPECTION_END_DT":"04/01/2003","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2003-04-01"},{"SOURCE_ROW_NUMBER":"802135","EVENT_NO":"4185467","INSPECTION_BEGIN_DT":"03/31/2003","INSPECTION_END_DT":"04/01/2003","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2003-03-31"},{"SOURCE_ROW_NUMBER":"290037","EVENT_NO":"4180196","INSPECTION_BEGIN_DT":"03/24/2003","INSPECTION_END_DT":"03/31/2003","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2003-03-24"},{"SOURCE_ROW_NUMBER":"1108493","EVENT_NO":"4179541","INSPECTION_BEGIN_DT":"02/18/2003","INSPECTION_END_DT":"03/03/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2003-02-18"},{"SOURCE_ROW_NUMBER":"39291","EVENT_NO":"4167904","INSPECTION_BEGIN_DT":"12/27/2002","INSPECTION_END_DT":"03/24/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"110.5","SUM_TOTAL_ON_SITE_HOURS":"68.5","sourceDate":"2002-12-27"},{"SOURCE_ROW_NUMBER":"898003","EVENT_NO":"4180176","INSPECTION_BEGIN_DT":"12/12/2002","INSPECTION_END_DT":"01/09/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"26.5","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2002-12-12"},{"SOURCE_ROW_NUMBER":"950006","EVENT_NO":"4179531","INSPECTION_BEGIN_DT":"12/11/2002","INSPECTION_END_DT":"12/12/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2002-12-11"},{"SOURCE_ROW_NUMBER":"503643","EVENT_NO":"4179527","INSPECTION_BEGIN_DT":"11/25/2002","INSPECTION_END_DT":"11/25/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2002-11-25"},{"SOURCE_ROW_NUMBER":"912709","EVENT_NO":"4179514","INSPECTION_BEGIN_DT":"10/10/2002","INSPECTION_END_DT":"10/10/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2002-10-10"},{"SOURCE_ROW_NUMBER":"380846","EVENT_NO":"4168181","INSPECTION_BEGIN_DT":"10/01/2002","INSPECTION_END_DT":"12/20/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"108","SUM_TOTAL_ON_SITE_HOURS":"80","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"665296","EVENT_NO":"4164513","INSPECTION_BEGIN_DT":"09/24/2002","INSPECTION_END_DT":"09/27/2002","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2002-09-24"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003-Q2":{"hours":1075,"employees":10,"production":0},"2003-Q1":{"hours":3468,"employees":19,"production":8130},"2002-Q4":{"hours":4422,"employees":13,"production":9751},"2002-Q3":{"hours":2334,"employees":15,"production":5286},"2002-Q2":{"hours":12958,"employees":25,"production":27174},"2002-Q1":{"hours":17155,"employees":33,"production":41560},"2001-Q4":{"hours":2600,"employees":5,"production":0},"2000-Q4":{"hours":2130,"employees":12,"production":1803}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":2130,"employees":12,"production":1803},"2001":{"hours":2600,"employees":5,"production":0},"2002":{"hours":36869,"employees":23,"production":83771},"2003":{"hours":4543,"employees":15,"production":8130}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":116,"firstDate":"2000-11-21","lastDate":"2003-04-23","metrics":{"ss":63,"amountDue":11658,"contested":0,"amountPaid":2875,"recentRows":0,"section104d":0,"unterminated":3,"proposedPenalty":11658},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"975584","VIOLATION_NO":"7399041","VIOLATION_ISSUE_DT":"04/23/2003","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-04-23"},{"SOURCE_ROW_NUMBER":"975583","VIOLATION_NO":"7398680","VIOLATION_ISSUE_DT":"04/23/2003","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/30/2003","CONTESTED_IND":"N","sourceDate":"2003-04-23"},{"SOURCE_ROW_NUMBER":"975574","VIOLATION_NO":"7389700","VIOLATION_ISSUE_DT":"04/01/2003","SIG_SUB":"Y","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/23/2003","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-04-01"},{"SOURCE_ROW_NUMBER":"975573","VIOLATION_NO":"7389699","VIOLATION_ISSUE_DT":"04/01/2003","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/23/2003","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-04-01"},{"SOURCE_ROW_NUMBER":"975572","VIOLATION_NO":"7389698","VIOLATION_ISSUE_DT":"04/01/2003","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"2041","AMOUNT_DUE":"2041","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-04-01"},{"SOURCE_ROW_NUMBER":"975670","VIOLATION_NO":"7398886","VIOLATION_ISSUE_DT":"02/28/2003","SIG_SUB":"Y","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/13/2003","PROPOSED_PENALTY":"161","AMOUNT_DUE":"161","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-02-28"},{"SOURCE_ROW_NUMBER":"975669","VIOLATION_NO":"7398882","VIOLATION_ISSUE_DT":"02/19/2003","SIG_SUB":"Y","PART_SECTION":"75.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/13/2003","PROPOSED_PENALTY":"113","AMOUNT_DUE":"113","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-02-19"},{"SOURCE_ROW_NUMBER":"975668","VIOLATION_NO":"7398769","VIOLATION_ISSUE_DT":"01/30/2003","PART_SECTION":"75.310(a)(4)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"03/13/2003","CONTESTED_IND":"N","sourceDate":"2003-01-30"},{"SOURCE_ROW_NUMBER":"975667","VIOLATION_NO":"7398768","VIOLATION_ISSUE_DT":"01/30/2003","SIG_SUB":"Y","PART_SECTION":"75.310(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/31/2003","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-01-30"},{"SOURCE_ROW_NUMBER":"975666","VIOLATION_NO":"7398767","VIOLATION_ISSUE_DT":"01/30/2003","SIG_SUB":"Y","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/31/2003","PROPOSED_PENALTY":"76","AMOUNT_DUE":"76","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-01-30"},{"SOURCE_ROW_NUMBER":"975665","VIOLATION_NO":"7398766","VIOLATION_ISSUE_DT":"01/30/2003","SIG_SUB":"Y","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/13/2003","PROPOSED_PENALTY":"69","AMOUNT_DUE":"69","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-01-30"},{"SOURCE_ROW_NUMBER":"975664","VIOLATION_NO":"7398765","VIOLATION_ISSUE_DT":"01/30/2003","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/31/2003","PROPOSED_PENALTY":"104","AMOUNT_DUE":"104","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-01-30"}]}],"safety":{"href":"/api/v1/mines/1518287/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518287/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Underground storage, lubricating oil and grease.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1104","part":"75","subchapter":"O","subpart":"L","id":"75.1104","citation":"30 CFR 75.1104","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518287","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}