{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518249","name":"Creech #1","status":"Abandoned","status_date":"2004-05-27","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Harlan","nearest_town":"Louellen","operator_id":"P24575","operator_name":"Powell Mountain Coal Co., Inc","controller_id":"C16016","controller_name":"Progress Energy Inc","district":"C07","office":"Harlan KY Field Office","employees":0,"latitude":36.912222,"longitude":-83.059166},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1511},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518249","name":"Creech #1"},"operator":{"type":"operator","id":"P24575","name":"Powell Mountain Coal Co., Inc"},"controller":{"type":"controller","id":"C16016","name":"Progress Energy Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14045","name":"Florida Progress Corporation"},"object":{"type":"mine","id":"1518249","name":"Creech #1"},"validFrom":"1997-09-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518249|C14045|1997-09-25|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24201","name":"Powell Mountain Coal Company Inc"},"object":{"type":"mine","id":"1518249","name":"Creech #1"},"validFrom":"2000-03-01","validTo":"2000-11-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518249|P24201|2000-03-01|2000-11-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14045","name":"Florida Progress Corporation"},"object":{"type":"operator","id":"P24201","name":"Powell Mountain Coal Company Inc"},"validFrom":"2000-03-01","validTo":"2000-11-29","current":false,"derived":true,"evidenceMineId":"1518249","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518249|P24201|2000-03-01|C14045|1997-09-25|91852"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24575","name":"Powell Mountain Coal Co., Inc"},"object":{"type":"mine","id":"1518249","name":"Creech #1"},"validFrom":"2000-11-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518249|P24575|2000-11-30|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16016","name":"Progress Energy Inc"},"object":{"type":"mine","id":"1518249","name":"Creech #1"},"validFrom":"2000-11-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518249|C16016|2000-11-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16016","name":"Progress Energy Inc"},"object":{"type":"operator","id":"P24575","name":"Powell Mountain Coal Co., Inc"},"validFrom":"2000-11-30","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518249","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518249|P24575|2000-11-30|C16016|2000-11-30|98030"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":10,"firstDate":"2000-11-01","lastDate":"2003-07-07","metrics":{"daysLost":503,"injuries":9,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"31564","DOCUMENT_NO":"220032450025","ACCIDENT_DT":"07/07/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"251","NARRATIVE":"THE EE WAS OPERATING A FLETCHER ROOF DRILL, WHEN A PIECE OF ROCK FELL HITTING THE EE ON THE BACK. ROCK WAS 4\"X 19\"LONG X 3\". EE WORKED HIS USUSAL JOB WITH NO PROBLEM UNTIL 8/26/03. HE CALLED I N ON THAT DAY AND SAID HE WAS GOING TO THE DR. ABOUT HIS ACCIDENT OF 7/7/03. HE HAS NOT RETURNED.","sourceDate":"2003-07-07"},{"SOURCE_ROW_NUMBER":"182099","DOCUMENT_NO":"220031890001","ACCIDENT_DT":"06/09/2003","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"EE WAS CRAWLING TOWARD FRONT OF DRILL TO START BOLTING WHEN A SLIP CAME OUT OF THE RIB HITTING HIM ON THE BACK. RECEIVED A POSITIVE MRI READING 06/26/03 FOR A HERNIATED DISC.","sourceDate":"2003-06-09"},{"SOURCE_ROW_NUMBER":"220818","DOCUMENT_NO":"220031110002","ACCIDENT_DT":"04/12/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL MEASURING 20'LONG X 18'WIDE X 3 1/2' TO 5'HIGH WAS DISCOVERED IN #2 ENTRY IN 2ND INTERSECTION APPROX. 700' OUTBY THE ACTIVE SECTION. LOCATION IS 60' TO 80' INBY SS #210.","sourceDate":"2003-04-12"},{"SOURCE_ROW_NUMBER":"18606","DOCUMENT_NO":"220031060031","ACCIDENT_DT":"02/20/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"1","DAYS_LOST":"21","NARRATIVE":"EMPLOYEE WAS LOADING POWER CABLE ON A SLED AND EXPERIENCED PAIN BELOW HIS BELT. EMPLOYEE WORKED UNTIL 2-20-03.","sourceDate":"2003-02-20"},{"SOURCE_ROW_NUMBER":"151994","DOCUMENT_NO":"220030230031","ACCIDENT_DT":"02/17/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"1","DAYS_LOST":"124","NARRATIVE":"THE EE ADVISED HIS FOREMAN THAT HE HAD TWISTED HIS KNEE WHILE SERVICING THE JOY MINER. THE EE ADVISED THAT HE WOULD GO TO DR. LATER. ON 1-22-03 EE ADVISED THE HE WOULD NEED TO GO TO DR AT A LA TER TIME, HE WOULD BE BACK TO WORK WHEN HE FELT BETTER AS OF 1-23-03 THE EE HAD NOT WENT TO DR.","sourceDate":"2003-02-17"},{"SOURCE_ROW_NUMBER":"117400","DOCUMENT_NO":"220022490039","ACCIDENT_DT":"01/11/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE STATED THAT INCIDENT WHICH ALLEGEDLY OCCURRED IN JANUARY 02 RESULTED IN HERNIA DIAGNOSED MONTHS LATER. HE HURT HIS HAND IN AUGUST, PREVENTING HIM FROM WORKING. WHILE OFF WORK WITH THIS NON-WORK RELATED INJURY, HE HAD HERNIA REPAIRED. HE IS EXPECTED TO BE READY TO WORK FROM SURGERY PRIOR TO RELEASE FOR HAND.","sourceDate":"2002-01-11"},{"SOURCE_ROW_NUMBER":"57263","DOCUMENT_NO":"220011350032","ACCIDENT_DT":"05/06/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"EE WAS OPERATING A SHUTTLE CAR. AS HE WAS TRAVELING UP THE ENTRY, HE PLACED HIS HAND ON TOP OF THE CAR CANOPY AND HIS FINGER WAS CAUGHT BETWEEN THE CANOPY AND THE MINE ROOF. FRACTURE AND LACER ATION TO LEFT RING FINGER. RETURNED TO REGULAR DUTIES NEXT SCHEDULED SHIFT.","sourceDate":"2001-05-06"},{"SOURCE_ROW_NUMBER":"57262","DOCUMENT_NO":"220003260039","ACCIDENT_DT":"11/12/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE ALLEGED THAT HIS BACK AND LEG STARTED HURTING WHILE HELPING HANG MINER CABLE.","sourceDate":"2000-11-12"},{"SOURCE_ROW_NUMBER":"108672","DOCUMENT_NO":"220010860033","ACCIDENT_DT":"11/05/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"50","NARRATIVE":"EE WAS OPERATING SHUTTLE CAR AND AS HE TURNED AROUND TO CHANGE DIRECTIONS, HE TWISTED HIS LEFT KNEE. HE WORKED AT HIS REGULAR JOB UNTIL HAVING SURGERY 3/21/01. BEGAN MISSING 3/23/01.","sourceDate":"2000-11-05"},{"SOURCE_ROW_NUMBER":"139054","DOCUMENT_NO":"220003190001","ACCIDENT_DT":"11/01/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"55","NARRATIVE":"EE ALLEGED THAT HE HURT HIS BACK WHILE LOADING HIGH VOLTAGE CABLE ONTO SLED.","sourceDate":"2000-11-01"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2004-05-27","lastDate":"2004-05-27","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":307,"firstDate":"2000-06-06","lastDate":"2004-03-04","metrics":{"ss":121,"delinquent":289,"recentRows":0,"paidPenalty":24587,"proposedPenalty":47587,"currentAssessment":47303},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1123410","VIOLATION_NO":"7538382","ISSUE_DT":"03/04/2004","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"228.00","CURRENT_ASSESSMENT_AMT":"228.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"1123409","VIOLATION_NO":"7538371","ISSUE_DT":"02/18/2004","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-18"},{"SOURCE_ROW_NUMBER":"1123408","VIOLATION_NO":"7538370","ISSUE_DT":"02/17/2004","CFR_STANDARD_CD":"75.523-3(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-17"},{"SOURCE_ROW_NUMBER":"1123411","VIOLATION_NO":"7540239","ISSUE_DT":"02/14/2004","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"228.00","CURRENT_ASSESSMENT_AMT":"228.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-14"},{"SOURCE_ROW_NUMBER":"1123407","VIOLATION_NO":"7538369","ISSUE_DT":"02/11/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-11"},{"SOURCE_ROW_NUMBER":"1123406","VIOLATION_NO":"7538368","ISSUE_DT":"02/10/2004","CFR_STANDARD_CD":"75.360(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-10"},{"SOURCE_ROW_NUMBER":"1123405","VIOLATION_NO":"7538367","ISSUE_DT":"02/10/2004","CFR_STANDARD_CD":"77.809","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-10"},{"SOURCE_ROW_NUMBER":"1123404","VIOLATION_NO":"7538366","ISSUE_DT":"02/10/2004","CFR_STANDARD_CD":"77.505","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-10"},{"SOURCE_ROW_NUMBER":"1123403","VIOLATION_NO":"7538365","ISSUE_DT":"02/04/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"1123402","VIOLATION_NO":"7538364","ISSUE_DT":"02/04/2004","CFR_STANDARD_CD":"75.370","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"1123401","VIOLATION_NO":"7538363","ISSUE_DT":"02/04/2004","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"1123400","VIOLATION_NO":"7538362","ISSUE_DT":"02/04/2004","CFR_STANDARD_CD":"75.310(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-04"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":7,"firstDate":"2001-03-23","lastDate":"2004-05-13","metrics":{"appeals":0,"decisions":7,"recentRows":0,"decisionPenalty":409,"originalPenalty":706},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"181498","VIOLATION_NO":"7536546","DOCKET_NO":"KENT 2004-9","DECISION_DT":"05/13/2004","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"55.00","DECISION_PENALTY_AMT":"55.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-05-13"},{"SOURCE_ROW_NUMBER":"473417","VIOLATION_NO":"7463969","DOCKET_NO":"KENT20030169","DECISION_DT":"05/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"122.00","DECISION_PENALTY_AMT":"122.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2003-05-22"},{"SOURCE_ROW_NUMBER":"472871","VIOLATION_NO":"7463964","DOCKET_NO":"KENT20030169","DECISION_DT":"05/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"122.00","DECISION_PENALTY_AMT":"122.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2003-05-22"},{"SOURCE_ROW_NUMBER":"174929","VIOLATION_NO":"7463974","DOCKET_NO":"KENT20030169","DECISION_DT":"05/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"55.00","DECISION_PENALTY_AMT":"55.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2003-05-22"},{"SOURCE_ROW_NUMBER":"472976","VIOLATION_NO":"7461972","DOCKET_NO":"KENT20010080","DECISION_DT":"05/16/2001","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"55.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2001-05-16"},{"SOURCE_ROW_NUMBER":"174649","VIOLATION_NO":"7461971","DOCKET_NO":"KENT20010080","DECISION_DT":"05/16/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"97.00","DECISION_PENALTY_AMT":"55.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2001-05-16"},{"SOURCE_ROW_NUMBER":"472870","VIOLATION_NO":"7460178","DOCKET_NO":"KENT20010047","DECISION_DT":"03/23/2001","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"200.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2001-03-23"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":373,"firstDate":"2000-06-08","lastDate":"2004-03-08","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":18,"validSamples":355,"maxConcentration":5.14,"concentrationTotal":143.16},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1097563","CASS_NUM":"57535279","SMP_TAKEN_DT":"3/8/2004","CONC":".121","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-08"},{"SOURCE_ROW_NUMBER":"907490","CASS_NUM":"57535304","SMP_TAKEN_DT":"3/8/2004","CONC":".086","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-08"},{"SOURCE_ROW_NUMBER":"558527","CASS_NUM":"57535326","SMP_TAKEN_DT":"3/8/2004","CONC":".02","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-08"},{"SOURCE_ROW_NUMBER":"516950","CASS_NUM":"57535262","SMP_TAKEN_DT":"3/8/2004","CONC":".085","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-08"},{"SOURCE_ROW_NUMBER":"194569","CASS_NUM":"57535272","SMP_TAKEN_DT":"3/8/2004","CONC":".25","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-08"},{"SOURCE_ROW_NUMBER":"122650","CASS_NUM":"57535251","SMP_TAKEN_DT":"3/8/2004","CONC":".05","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-08"},{"SOURCE_ROW_NUMBER":"1149476","CASS_NUM":"57521775","SMP_TAKEN_DT":"2/11/2004","CONC":".473","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-11"},{"SOURCE_ROW_NUMBER":"1090400","CASS_NUM":"57521734","SMP_TAKEN_DT":"2/11/2004","CONC":".178","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-11"},{"SOURCE_ROW_NUMBER":"1055326","CASS_NUM":"57521739","SMP_TAKEN_DT":"2/11/2004","CONC":"1.061","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-11"},{"SOURCE_ROW_NUMBER":"898706","CASS_NUM":"57521771","SMP_TAKEN_DT":"2/11/2004","CONC":".277","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-11"},{"SOURCE_ROW_NUMBER":"643193","CASS_NUM":"57521752","SMP_TAKEN_DT":"2/11/2004","CONC":".091","SMP_TYPE_CD_DESC":"NONDESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SUPPLY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-11"},{"SOURCE_ROW_NUMBER":"261200","CASS_NUM":"57521778","SMP_TAKEN_DT":"2/11/2004","CONC":"0","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-11"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":46,"firstDate":"2000-08-10","lastDate":"2004-04-12","metrics":{"linkedIssuances":46},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":214,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":30,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2000-03-01","lastDate":"2000-11-30","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":87,"firstDate":"2000-06-05","lastDate":"2005-04-07","metrics":{"inspectors":108,"recentRows":0,"onSiteHours":1426.5,"inspectionHours":2245.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"449850","EVENT_NO":"4228082","INSPECTION_BEGIN_DT":"04/07/2005","INSPECTION_END_DT":"06/15/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2005-04-07"},{"SOURCE_ROW_NUMBER":"90483","EVENT_NO":"4241020","INSPECTION_BEGIN_DT":"03/24/2005","INSPECTION_END_DT":"03/24/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-03-24"},{"SOURCE_ROW_NUMBER":"83424","EVENT_NO":"4241014","INSPECTION_BEGIN_DT":"12/27/2004","INSPECTION_END_DT":"12/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"114587","EVENT_NO":"4228180","INSPECTION_BEGIN_DT":"07/26/2004","INSPECTION_END_DT":"07/26/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2004-07-26"},{"SOURCE_ROW_NUMBER":"861191","EVENT_NO":"4228173","INSPECTION_BEGIN_DT":"05/18/2004","INSPECTION_END_DT":"06/24/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"522812","EVENT_NO":"4232110","INSPECTION_BEGIN_DT":"01/21/2004","INSPECTION_END_DT":"02/03/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2004-01-21"},{"SOURCE_ROW_NUMBER":"297522","EVENT_NO":"4232109","INSPECTION_BEGIN_DT":"01/21/2004","INSPECTION_END_DT":"02/03/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-01-21"},{"SOURCE_ROW_NUMBER":"468579","EVENT_NO":"4228224","INSPECTION_BEGIN_DT":"01/05/2004","INSPECTION_END_DT":"03/16/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"117.5","SUM_TOTAL_ON_SITE_HOURS":"82","sourceDate":"2004-01-05"},{"SOURCE_ROW_NUMBER":"800280","EVENT_NO":"4227968","INSPECTION_BEGIN_DT":"11/26/2003","INSPECTION_END_DT":"11/26/2003","ACTIVITY_CODE":"ADA","ACTIVITY":"103(G)(1) SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2003-11-26"},{"SOURCE_ROW_NUMBER":"1053960","EVENT_NO":"4231413","INSPECTION_BEGIN_DT":"11/19/2003","INSPECTION_END_DT":"12/03/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2003-11-19"},{"SOURCE_ROW_NUMBER":"496156","EVENT_NO":"4217323","INSPECTION_BEGIN_DT":"11/10/2003","INSPECTION_END_DT":"11/13/2003","ACTIVITY_CODE":"AEA","ACTIVITY":"TOXIC SUBS OR HARMFUL PHY AGENT INV","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2003-11-10"},{"SOURCE_ROW_NUMBER":"221978","EVENT_NO":"4228220","INSPECTION_BEGIN_DT":"11/10/2003","INSPECTION_END_DT":"12/09/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"90","SUM_TOTAL_ON_SITE_HOURS":"59","sourceDate":"2003-11-10"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":45,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q2":{"hours":1708,"employees":5,"production":0},"2004-Q1":{"hours":17240,"employees":41,"production":39509},"2003-Q4":{"hours":21969,"employees":36,"production":37367},"2003-Q3":{"hours":29409,"employees":55,"production":61647},"2003-Q2":{"hours":30915,"employees":56,"production":65298},"2003-Q1":{"hours":31520,"employees":57,"production":75154},"2002-Q4":{"hours":31704,"employees":61,"production":83683},"2002-Q3":{"hours":32740,"employees":61,"production":90294},"2002-Q2":{"hours":33250,"employees":63,"production":107647},"2002-Q1":{"hours":34448,"employees":64,"production":87802},"2001-Q4":{"hours":33317,"employees":61,"production":100449},"2001-Q3":{"hours":33736,"employees":59,"production":102671}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":11,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":31501,"employees":31,"production":45794},"2001":{"hours":121066,"employees":56,"production":295059},"2002":{"hours":132142,"employees":62,"production":369426},"2003":{"hours":113813,"employees":52,"production":239466},"2004":{"hours":18948,"employees":23,"production":39509}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":21,"firstDate":"2000-12-19","lastDate":"2004-01-21","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":1617,"pelDoseTotal":1170},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"71171","EVENT_NO":"4232110","SURVEY_DATE":"01/21/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"63","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2004-01-21"},{"SOURCE_ROW_NUMBER":"71170","EVENT_NO":"4232110","SURVEY_DATE":"01/21/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"69","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2004-01-21"},{"SOURCE_ROW_NUMBER":"71169","EVENT_NO":"4232110","SURVEY_DATE":"01/21/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"65","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2004-01-21"},{"SOURCE_ROW_NUMBER":"71165","EVENT_NO":"4230757","SURVEY_DATE":"12/18/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"72","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2002-12-18"},{"SOURCE_ROW_NUMBER":"71164","EVENT_NO":"4230757","SURVEY_DATE":"12/18/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"63","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2002-12-18"},{"SOURCE_ROW_NUMBER":"71163","EVENT_NO":"4230757","SURVEY_DATE":"12/18/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"92","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2002-12-18"},{"SOURCE_ROW_NUMBER":"71162","EVENT_NO":"4230757","SURVEY_DATE":"12/18/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"86","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2002-12-18"},{"SOURCE_ROW_NUMBER":"71161","EVENT_NO":"4230757","SURVEY_DATE":"12/18/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"118","PEL_DOSE_90":"94","SURVEY_TYPE":"I","sourceDate":"2002-12-18"},{"SOURCE_ROW_NUMBER":"71160","EVENT_NO":"4230742","SURVEY_DATE":"10/31/2002","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"56","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2002-10-31"},{"SOURCE_ROW_NUMBER":"71168","EVENT_NO":"4231338","SURVEY_DATE":"09/30/2002","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"38","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2002-09-30"},{"SOURCE_ROW_NUMBER":"71167","EVENT_NO":"4231338","SURVEY_DATE":"09/30/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"67","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2002-09-30"},{"SOURCE_ROW_NUMBER":"71166","EVENT_NO":"4231338","SURVEY_DATE":"09/30/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"150","PEL_DOSE_90":"132","SURVEY_TYPE":"I","sourceDate":"2002-09-30"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":26,"firstDate":"2000-06-08","lastDate":"2004-02-11","metrics":{"recentRows":0,"voidSamples":7,"maxQuartzPct":38,"validSamples":19,"quartzPctTotal":294.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"51322","CASSETTE_NO":"57521739","SAMPLE_DT":"02/11/2004","QUARTZ_PCT":"11.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-11"},{"SOURCE_ROW_NUMBER":"105869","CASSETTE_NO":"50729039","SAMPLE_DT":"12/29/2003","QUARTZ_PCT":"08.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2003-12-29"},{"SOURCE_ROW_NUMBER":"45484","CASSETTE_NO":"50729041","SAMPLE_DT":"12/08/2003","QUARTZ_PCT":"38.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-08"},{"SOURCE_ROW_NUMBER":"66872","CASSETTE_NO":"50609993","SAMPLE_DT":"11/14/2002","QUARTZ_PCT":"10.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-11-14"},{"SOURCE_ROW_NUMBER":"162379","CASSETTE_NO":"57400114","SAMPLE_DT":"11/28/2001","QUARTZ_PCT":"00.9","OCC_CODE_DESC":"LABORER","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"149080","CASSETTE_NO":"50609766","SAMPLE_DT":"11/26/2001","QUARTZ_PCT":"14.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"94160","CASSETTE_NO":"50609777","SAMPLE_DT":"11/26/2001","QUARTZ_PCT":"11.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"90101","CASSETTE_NO":"50609772","SAMPLE_DT":"11/12/2001","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2001-11-12"},{"SOURCE_ROW_NUMBER":"4882","CASSETTE_NO":"50609805","SAMPLE_DT":"11/12/2001","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2001-11-12"},{"SOURCE_ROW_NUMBER":"70931","CASSETTE_NO":"57359792","SAMPLE_DT":"10/19/2001","QUARTZ_PCT":"22.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-10-19"},{"SOURCE_ROW_NUMBER":"6329","CASSETTE_NO":"57360119","SAMPLE_DT":"10/19/2001","QUARTZ_PCT":"11.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-10-19"},{"SOURCE_ROW_NUMBER":"6244","CASSETTE_NO":"50609810","SAMPLE_DT":"10/02/2001","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2001-10-02"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":330,"firstDate":"2000-06-06","lastDate":"2004-03-04","metrics":{"ss":125,"amountDue":47303,"contested":5,"amountPaid":24587,"recentRows":0,"section104d":4,"unterminated":5,"proposedPenalty":47587},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"969890","VIOLATION_NO":"7538382","VIOLATION_ISSUE_DT":"03/04/2004","SIG_SUB":"Y","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/04/2004","PROPOSED_PENALTY":"228","AMOUNT_DUE":"228","AMOUNT_PAID":"228","CONTESTED_IND":"N","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"969889","VIOLATION_NO":"7538371","VIOLATION_ISSUE_DT":"02/18/2004","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/18/2004","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"72","CONTESTED_IND":"N","sourceDate":"2004-02-18"},{"SOURCE_ROW_NUMBER":"969888","VIOLATION_NO":"7538370","VIOLATION_ISSUE_DT":"02/17/2004","SIG_SUB":"N","PART_SECTION":"75.523-3(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/04/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-02-17"},{"SOURCE_ROW_NUMBER":"969891","VIOLATION_NO":"7540239","VIOLATION_ISSUE_DT":"02/14/2004","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/17/2004","PROPOSED_PENALTY":"228","AMOUNT_DUE":"228","AMOUNT_PAID":"228","CONTESTED_IND":"N","sourceDate":"2004-02-14"},{"SOURCE_ROW_NUMBER":"969887","VIOLATION_NO":"7538369","VIOLATION_ISSUE_DT":"02/11/2004","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/11/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-02-11"},{"SOURCE_ROW_NUMBER":"969886","VIOLATION_NO":"7538368","VIOLATION_ISSUE_DT":"02/10/2004","SIG_SUB":"N","PART_SECTION":"75.360(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/10/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-02-10"},{"SOURCE_ROW_NUMBER":"969885","VIOLATION_NO":"7538367","VIOLATION_ISSUE_DT":"02/10/2004","SIG_SUB":"N","PART_SECTION":"77.809","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/10/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-02-10"},{"SOURCE_ROW_NUMBER":"969884","VIOLATION_NO":"7538366","VIOLATION_ISSUE_DT":"02/10/2004","SIG_SUB":"N","PART_SECTION":"77.505","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/10/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-02-10"},{"SOURCE_ROW_NUMBER":"969883","VIOLATION_NO":"7538365","VIOLATION_ISSUE_DT":"02/04/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/10/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"969882","VIOLATION_NO":"7538364","VIOLATION_ISSUE_DT":"02/04/2004","SIG_SUB":"N","PART_SECTION":"75.370","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/10/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"969881","VIOLATION_NO":"7538363","VIOLATION_ISSUE_DT":"02/04/2004","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/04/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"969880","VIOLATION_NO":"7538362","VIOLATION_ISSUE_DT":"02/04/2004","SIG_SUB":"N","PART_SECTION":"75.310(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/10/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-02-04"}]}],"safety":{"href":"/api/v1/mines/1518249/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518249/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.809","heading":"Identification of circuit breakers and disconnecting switches.","id":"77.809","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-I/section-77.809","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"I","subpartHeading":"Subpart I—Surface High-Voltage Distribution","text":"Circuit breakers and disconnecting switches shall be labeled to show which units they control, unless identification can be made readily by location.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.505","heading":"Cable fittings; suitability.","id":"77.505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.505","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Cables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires, other than cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518249","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}