{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"1518244","name":"Auger Mine #26","status":"Abandoned","status_date":"2002-09-20","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Letcher","nearest_town":"Deane","operator_id":"P18088","operator_name":"B & H Coal Company Inc","controller_id":"C12638","controller_name":"G B  Hendrickson","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.2625,"longitude":-82.669444},"coverage":{"contributingSources":10,"registeredSources":20,"sourceRows":55},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518244","name":"Auger Mine #26"},"operator":{"type":"operator","id":"P18088","name":"B & H Coal Company Inc"},"controller":{"type":"controller","id":"C12638","name":"G B  Hendrickson"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12638","name":"G B  Hendrickson"},"object":{"type":"mine","id":"1518244","name":"Auger Mine #26"},"validFrom":"1986-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1518244|C12638|1986-11-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P18088","name":"B & H Coal Company Inc"},"object":{"type":"mine","id":"1518244","name":"Auger Mine #26"},"validFrom":"2000-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1518244|P18088|2000-03-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12638","name":"G B  Hendrickson"},"object":{"type":"operator","id":"P18088","name":"B & H Coal Company Inc"},"validFrom":"2000-03-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518244","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1518244|P18088|2000-03-01|C12638|1986-11-01|87561"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-09-20","lastDate":"2002-09-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":8,"firstDate":"2000-03-29","lastDate":"2001-11-26","metrics":{"ss":1,"delinquent":8,"recentRows":0,"paidPenalty":489,"proposedPenalty":489,"currentAssessment":489},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"957900","VIOLATION_NO":"4229171","ISSUE_DT":"11/26/2001","CFR_STANDARD_CD":"71.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"955040","VIOLATION_NO":"4229385","ISSUE_DT":"09/18/2001","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-18"},{"SOURCE_ROW_NUMBER":"954709","VIOLATION_NO":"7377569","ISSUE_DT":"03/01/2001","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-03-01"},{"SOURCE_ROW_NUMBER":"954708","VIOLATION_NO":"7377568","ISSUE_DT":"03/01/2001","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-03-01"},{"SOURCE_ROW_NUMBER":"954707","VIOLATION_NO":"7377567","ISSUE_DT":"03/01/2001","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"104.00","CURRENT_ASSESSMENT_AMT":"104.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-03-01"},{"SOURCE_ROW_NUMBER":"952836","VIOLATION_NO":"7372248","ISSUE_DT":"09/15/2000","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-09-15"},{"SOURCE_ROW_NUMBER":"1632964","VIOLATION_NO":"4035862","ISSUE_DT":"03/29/2000","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"1632963","VIOLATION_NO":"4035861","ISSUE_DT":"03/29/2000","CFR_STANDARD_CD":"77.1501(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-03-29"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":9,"firstDate":"2000-03-29","lastDate":"2001-03-01","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":9,"maxConcentration":0.277,"concentrationTotal":1.497},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1603530","CASS_NUM":"57339658","SMP_TAKEN_DT":"3/1/2001","CONC":".181","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-03-01"},{"SOURCE_ROW_NUMBER":"1597919","CASS_NUM":"57339659","SMP_TAKEN_DT":"3/1/2001","CONC":".13","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-03-01"},{"SOURCE_ROW_NUMBER":"1371403","CASS_NUM":"57339682","SMP_TAKEN_DT":"3/1/2001","CONC":".276","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"GROUNDMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-03-01"},{"SOURCE_ROW_NUMBER":"767017","CASS_NUM":"57283605","SMP_TAKEN_DT":"9/15/2000","CONC":".104","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-09-15"},{"SOURCE_ROW_NUMBER":"286608","CASS_NUM":"57283607","SMP_TAKEN_DT":"9/15/2000","CONC":".114","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"GROUNDMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-09-15"},{"SOURCE_ROW_NUMBER":"11013","CASS_NUM":"57283586","SMP_TAKEN_DT":"9/15/2000","CONC":".109","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-09-15"},{"SOURCE_ROW_NUMBER":"1319019","CASS_NUM":"57264831","SMP_TAKEN_DT":"3/29/2000","CONC":".277","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER/BLACKSMITH","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"787277","CASS_NUM":"57264869","SMP_TAKEN_DT":"3/29/2000","CONC":".092","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"395768","CASS_NUM":"57264904","SMP_TAKEN_DT":"3/29/2000","CONC":".214","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-03-29"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2000-03-01","lastDate":"2000-03-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":12,"firstDate":"2000-03-23","lastDate":"2002-05-13","metrics":{"inspectors":14,"recentRows":0,"onSiteHours":55.5,"inspectionHours":88.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"541863","EVENT_NO":"4168042","INSPECTION_BEGIN_DT":"05/13/2002","INSPECTION_END_DT":"09/26/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2002-05-13"},{"SOURCE_ROW_NUMBER":"996177","EVENT_NO":"4168305","INSPECTION_BEGIN_DT":"11/20/2001","INSPECTION_END_DT":"12/06/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2001-11-20"},{"SOURCE_ROW_NUMBER":"709722","EVENT_NO":"4168204","INSPECTION_BEGIN_DT":"09/13/2001","INSPECTION_END_DT":"09/27/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2001-09-13"},{"SOURCE_ROW_NUMBER":"650253","EVENT_NO":"4168203","INSPECTION_BEGIN_DT":"09/13/2001","INSPECTION_END_DT":"09/27/2001","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2001-09-13"},{"SOURCE_ROW_NUMBER":"9827","EVENT_NO":"4167448","INSPECTION_BEGIN_DT":"08/21/2001","INSPECTION_END_DT":"09/27/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2001-08-21"},{"SOURCE_ROW_NUMBER":"843208","EVENT_NO":"4167276","INSPECTION_BEGIN_DT":"02/02/2001","INSPECTION_END_DT":"03/28/2001","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2001-02-02"},{"SOURCE_ROW_NUMBER":"555120","EVENT_NO":"4167275","INSPECTION_BEGIN_DT":"02/02/2001","INSPECTION_END_DT":"03/29/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2001-02-02"},{"SOURCE_ROW_NUMBER":"245006","EVENT_NO":"4166642","INSPECTION_BEGIN_DT":"09/15/2000","INSPECTION_END_DT":"09/28/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2000-09-15"},{"SOURCE_ROW_NUMBER":"239893","EVENT_NO":"4166643","INSPECTION_BEGIN_DT":"09/15/2000","INSPECTION_END_DT":"09/28/2000","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2000-09-15"},{"SOURCE_ROW_NUMBER":"1159250","EVENT_NO":"6185374","INSPECTION_BEGIN_DT":"03/29/2000","INSPECTION_END_DT":"03/30/2000","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"1120715","EVENT_NO":"6185373","INSPECTION_BEGIN_DT":"03/29/2000","INSPECTION_END_DT":"04/10/2000","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"33320","EVENT_NO":"6185372","INSPECTION_BEGIN_DT":"03/23/2000","INSPECTION_END_DT":"03/30/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2000-03-23"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q3":{"hours":0,"employees":0,"production":0},"2002-Q2":{"hours":0,"employees":0,"production":0},"2002-Q1":{"hours":0,"employees":0,"production":0},"2001-Q4":{"hours":211,"employees":2,"production":1829},"2001-Q3":{"hours":1575,"employees":5,"production":15499},"2001-Q2":{"hours":2859,"employees":6,"production":33263},"2001-Q1":{"hours":4264,"employees":6,"production":37520},"2000-Q4":{"hours":4535,"employees":5,"production":52004},"2000-Q3":{"hours":2780,"employees":5,"production":28391},"2000-Q2":{"hours":1856,"employees":5,"production":13482}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":9171,"employees":5,"production":93877},"2001":{"hours":8909,"employees":5,"production":88111}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":3,"firstDate":"2000-03-29","lastDate":"2000-03-29","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":359,"pelDoseTotal":295},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"71081","EVENT_NO":"6185374","SURVEY_DATE":"03/29/2000","OCCUPATION_CD_DESC":"AUGER HELPER","MACHINE_CD":"02","MANUFACTURER_CD":"097","ACT_DOSE_85":"78","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"71080","EVENT_NO":"6185374","SURVEY_DATE":"03/29/2000","OCCUPATION_CD_DESC":"AUGER OPERATOR","MACHINE_CD":"02","MANUFACTURER_CD":"097","ACT_DOSE_85":"142","PEL_DOSE_90":"121","SURVEY_TYPE":"I","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"71079","EVENT_NO":"6185374","SURVEY_DATE":"03/29/2000","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"02","MANUFACTURER_CD":"097","ACT_DOSE_85":"139","PEL_DOSE_90":"124","SURVEY_TYPE":"I","sourceDate":"2000-03-29"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":8,"firstDate":"2000-03-29","lastDate":"2001-11-26","metrics":{"ss":1,"amountDue":489,"contested":0,"amountPaid":489,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":489},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"969959","VIOLATION_NO":"4229171","VIOLATION_ISSUE_DT":"11/26/2001","SIG_SUB":"N","PART_SECTION":"71.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/17/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"969957","VIOLATION_NO":"4229385","VIOLATION_ISSUE_DT":"09/18/2001","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/26/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-18"},{"SOURCE_ROW_NUMBER":"969954","VIOLATION_NO":"7377569","VIOLATION_ISSUE_DT":"03/01/2001","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/05/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-03-01"},{"SOURCE_ROW_NUMBER":"969953","VIOLATION_NO":"7377568","VIOLATION_ISSUE_DT":"03/01/2001","SIG_SUB":"N","PART_SECTION":"77.208(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/01/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-03-01"},{"SOURCE_ROW_NUMBER":"969952","VIOLATION_NO":"7377567","VIOLATION_ISSUE_DT":"03/01/2001","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/05/2001","PROPOSED_PENALTY":"104","AMOUNT_DUE":"104","AMOUNT_PAID":"104","CONTESTED_IND":"N","sourceDate":"2001-03-01"},{"SOURCE_ROW_NUMBER":"969958","VIOLATION_NO":"7372248","VIOLATION_ISSUE_DT":"09/15/2000","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-09-15"},{"SOURCE_ROW_NUMBER":"969956","VIOLATION_NO":"4035862","VIOLATION_ISSUE_DT":"03/29/2000","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/10/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"969955","VIOLATION_NO":"4035861","VIOLATION_ISSUE_DT":"03/29/2000","SIG_SUB":"N","PART_SECTION":"77.1501(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/10/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-03-29"}]}],"safety":{"href":"/api/v1/mines/1518244/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518244/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Bathing facilities; change rooms; sanitary flush toilet facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-E/section-71.400","part":"71","subchapter":"O","subpart":"E","id":"71.400","citation":"30 CFR 71.400","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":3},{"chapter":"I","heading":"Auger mining; inspections.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-P/section-77.1501","part":"77","subchapter":"O","subpart":"P","id":"77.1501","citation":"30 CFR 77.1501","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518244","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}