{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518202","name":"Red Oak","status":"Abandoned","status_date":"2009-08-29","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Perry","nearest_town":"Vicco","operator_id":"0078583","operator_name":"Midwest Resources LLC","controller_id":"0066009","controller_name":"Gary L  Barker; Robert  Hatton","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.209166,"longitude":-83.018333},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1804},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518202","name":"Red Oak"},"operator":{"type":"operator","id":"0078583","name":"Midwest Resources LLC"},"controller":{"type":"controller","id":"0066009","name":"Gary L  Barker; Robert  Hatton"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C03753","name":"Talmage D  Meade"},"object":{"type":"mine","id":"1518202","name":"Red Oak"},"validFrom":"1975-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|C03753|1975-04-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P06670","name":"Meade & Shepherd Coal Company Inc"},"object":{"type":"mine","id":"1518202","name":"Red Oak"},"validFrom":"1999-09-01","validTo":"2003-01-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|P06670|1999-09-01|2003-01-21"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C03753","name":"Talmage D  Meade"},"object":{"type":"operator","id":"P06670","name":"Meade & Shepherd Coal Company Inc"},"validFrom":"1999-09-01","validTo":"2003-01-21","current":false,"derived":true,"evidenceMineId":"1518202","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|P06670|1999-09-01|C03753|1975-04-01|63750"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16073","name":"John C  Smith Jr"},"object":{"type":"mine","id":"1518202","name":"Red Oak"},"validFrom":"2001-03-19","validTo":"2006-01-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|C16073|2001-03-19|2006-01-16"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24602","name":"Appalachian Fuels, LLC"},"object":{"type":"mine","id":"1518202","name":"Red Oak"},"validFrom":"2003-01-22","validTo":"2007-01-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|P24602|2003-01-22|2007-01-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16073","name":"John C  Smith Jr"},"object":{"type":"operator","id":"P24602","name":"Appalachian Fuels, LLC"},"validFrom":"2003-01-22","validTo":"2006-01-16","current":false,"derived":true,"evidenceMineId":"1518202","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|P24602|2003-01-22|C16073|2001-03-19|98267"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0056689","name":"Energy Coal Resources Inc"},"object":{"type":"mine","id":"1518202","name":"Red Oak"},"validFrom":"2006-01-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|0056689|2006-01-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0056689","name":"Energy Coal Resources Inc"},"object":{"type":"operator","id":"P24602","name":"Appalachian Fuels, LLC"},"validFrom":"2006-01-17","validTo":"2007-01-31","current":false,"derived":true,"evidenceMineId":"1518202","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|P24602|2003-01-22|0056689|2006-01-17|7414"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0078583","name":"Midwest Resources LLC"},"object":{"type":"mine","id":"1518202","name":"Red Oak"},"validFrom":"2007-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|0078583|2007-02-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0066009","name":"Gary L  Barker et al"},"object":{"type":"mine","id":"1518202","name":"Red Oak"},"validFrom":"2007-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|0066009|2007-02-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0066009","name":"Gary L  Barker et al"},"object":{"type":"operator","id":"0078583","name":"Midwest Resources LLC"},"validFrom":"2007-02-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518202","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|0078583|2007-02-01|0066009|2007-02-01|9142"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0066009","name":"Robert  Hatton et al"},"object":{"type":"operator","id":"0078583","name":"Midwest Resources LLC"},"validFrom":"2007-02-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518202","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518202|0078583|2007-02-01|0066009|2007-02-01|9143"}}],"coverage":{"historyRecords":5,"edgeCount":12,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":31,"firstDate":"2000-03-31","lastDate":"2009-08-03","metrics":{"daysLost":1314,"injuries":31,"fatalities":0,"recentRows":0,"restrictedDays":7,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"216538","DOCUMENT_NO":"220092220037","ACCIDENT_DT":"08/03/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Working controls on excavator","sourceDate":"2009-08-03"},{"SOURCE_ROW_NUMBER":"35830","DOCUMENT_NO":"220091070027","ACCIDENT_DT":"04/06/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"314","NARRATIVE":"D11R operator contacted me by CB approx 11:20 PM stating that he had injured his back climbing on his dozer at worktime (5:30PM). He said the pain had worsened as the shift progressed. I took him to Whitesburg ARH. The x-ray was negative. They said he may have pulled muscle or strain. He was advised to see family doctor on April 7, 2009","sourceDate":"2009-04-06"},{"SOURCE_ROW_NUMBER":"27303","DOCUMENT_NO":"220083570080","ACCIDENT_DT":"12/06/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE stepped down from grease truck, in doing so he turned his ankle on a piece of frozen dirt.","sourceDate":"2008-12-06"},{"SOURCE_ROW_NUMBER":"57257","DOCUMENT_NO":"220083300056","ACCIDENT_DT":"11/07/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Pumper","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Operator was climbing down from 988 loader when he missed the bottom ladder rung or step causing him to turn his ankle when his foot made contact with the ground. He was taken to the A.R.H. ER where it was determinged he had sprained his ankle. He returned to work on 10 Nov 08 without missing a shift.","sourceDate":"2008-11-07"},{"SOURCE_ROW_NUMBER":"194852","DOCUMENT_NO":"220083230049","ACCIDENT_DT":"11/03/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"EE informed me at 2100 that he had injured his back getting on his equipment (992G) at work time. I then took EE to ARH (ER) for drug test and whatever medical treatment was needed.","sourceDate":"2008-11-03"},{"SOURCE_ROW_NUMBER":"169148","DOCUMENT_NO":"220080320055","ACCIDENT_DT":"01/23/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"Employee stated he dismounted D10 to use bathroom and was climbing back on the tractor when he slipped injuring his knee. He had knee problems prior to accident.","sourceDate":"2008-01-23"},{"SOURCE_ROW_NUMBER":"233728","DOCUMENT_NO":"220080160040","ACCIDENT_DT":"01/08/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"19","NARRATIVE":"Employee was checking oil on D10N when he lost his footing during heavy rain. The grab rail caused him to twist possibly causing strain or back injury.","sourceDate":"2008-01-08"},{"SOURCE_ROW_NUMBER":"14362","DOCUMENT_NO":"220062300018","ACCIDENT_DT":"08/16/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"207","NARRATIVE":"He was removing a roll over cab (ROPS), it twisted around, caught his knee between it and the rail.","sourceDate":"2006-08-16"},{"SOURCE_ROW_NUMBER":"91630","DOCUMENT_NO":"220041740015","ACCIDENT_DT":"06/09/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Operator got something in his eye while in the cab of the loader.  Stayed home one day from work on doctors recommendation.","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"242409","DOCUMENT_NO":"220033030003","ACCIDENT_DT":"10/20/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"16","NARRATIVE":"VICTIM STEPPED IN A DEPRESSION WHILE WALKING ACROSS EQUIPMENT PARKING LOT. PULLED TENDONS IN THE BOTTOM OF FOOT.","sourceDate":"2003-10-20"},{"SOURCE_ROW_NUMBER":"272385","DOCUMENT_NO":"220032900026","ACCIDENT_DT":"09/27/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Backhoe operator, Trackhoe operator, Crane operator","NO_INJURIES":"1","DAYS_LOST":"58","NARRATIVE":"OPERATOR STATES THAT HE BACKED THE DOZER OVER A SMALL ROCK AND IT JERKED HIM CAUSING PAIN IN LOWER BACK AND LEGS. STRAINED MUSCLE.","sourceDate":"2003-09-27"},{"SOURCE_ROW_NUMBER":"216537","DOCUMENT_NO":"220032900021","ACCIDENT_DT":"09/22/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Backhoe operator, Trackhoe operator, Crane operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"OPERATOR RAN OVER A ROCK WITH DOZER AND JERKED HIS BACK STRAINED MUSCLE.","sourceDate":"2003-09-22"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-08-29","lastDate":"2009-08-29","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":232,"firstDate":"2000-04-19","lastDate":"2009-04-09","metrics":{"ss":154,"delinquent":221,"recentRows":0,"paidPenalty":49242.3,"proposedPenalty":50811,"currentAssessment":50756},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1470831","VIOLATION_NO":"8339906","ISSUE_DT":"04/09/2009","CFR_STANDARD_CD":"71.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-04-09"},{"SOURCE_ROW_NUMBER":"1443494","VIOLATION_NO":"8327396","ISSUE_DT":"02/10/2009","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1026.00","CURRENT_ASSESSMENT_AMT":"1026.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-02-10"},{"SOURCE_ROW_NUMBER":"1443493","VIOLATION_NO":"8327394","ISSUE_DT":"02/06/2009","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-02-06"},{"SOURCE_ROW_NUMBER":"1443492","VIOLATION_NO":"8327393","ISSUE_DT":"02/06/2009","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1026.00","CURRENT_ASSESSMENT_AMT":"1026.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-02-06"},{"SOURCE_ROW_NUMBER":"1443491","VIOLATION_NO":"8327391","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1443490","VIOLATION_NO":"8327390","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1443489","VIOLATION_NO":"8327389","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1443488","VIOLATION_NO":"8327388","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1443487","VIOLATION_NO":"8327387","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"48.29(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1443486","VIOLATION_NO":"8327386","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1443485","VIOLATION_NO":"8327385","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"77.1607(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1443484","VIOLATION_NO":"8327384","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":4,"firstDate":"2001-05-24","lastDate":"2003-03-06","metrics":{"appeals":0,"decisions":4,"recentRows":0,"decisionPenalty":3491,"originalPenalty":3546},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"473491","VIOLATION_NO":"7480153","DOCKET_NO":"KENT20030057","DECISION_DT":"03/06/2003","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"500.00","DECISION_PENALTY_AMT":"500.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2003-03-06"},{"SOURCE_ROW_NUMBER":"472082","VIOLATION_NO":"7480182","DOCKET_NO":"KENT20030057","DECISION_DT":"03/06/2003","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"2500.00","DECISION_PENALTY_AMT":"2500.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2003-03-06"},{"SOURCE_ROW_NUMBER":"174888","VIOLATION_NO":"7480181","DOCKET_NO":"KENT20030057","DECISION_DT":"03/06/2003","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"350.00","DECISION_PENALTY_AMT":"350.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2003-03-06"},{"SOURCE_ROW_NUMBER":"174911","VIOLATION_NO":"7471358","DOCKET_NO":"KENT20010149","DECISION_DT":"05/24/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"196.00","DECISION_PENALTY_AMT":"141.00","JUDGE_FIRST_NAME":"Irwin","JUDGE_LAST_NAME":"Schroeder","sourceDate":"2001-05-24"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":269,"firstDate":"2000-01-19","lastDate":"2009-05-11","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":14,"validSamples":255,"maxConcentration":3.173,"concentrationTotal":87.513},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1662276","CASS_NUM":"57749922","SMP_TAKEN_DT":"5/11/2009","CONC":".1","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-11"},{"SOURCE_ROW_NUMBER":"1583904","CASS_NUM":"57749938","SMP_TAKEN_DT":"5/11/2009","CONC":".191","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-11"},{"SOURCE_ROW_NUMBER":"1324132","CASS_NUM":"57749939","SMP_TAKEN_DT":"5/11/2009","CONC":".077","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-11"},{"SOURCE_ROW_NUMBER":"1110994","CASS_NUM":"57749948","SMP_TAKEN_DT":"5/11/2009","CONC":".057","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-11"},{"SOURCE_ROW_NUMBER":"356506","CASS_NUM":"57749945","SMP_TAKEN_DT":"5/11/2009","CONC":".095","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-11"},{"SOURCE_ROW_NUMBER":"1052399","CASS_NUM":"57766520","SMP_TAKEN_DT":"1/21/2009","CONC":".383","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"490769","CASS_NUM":"57766635","SMP_TAKEN_DT":"1/21/2009","CONC":".26","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"447877","CASS_NUM":"57766626","SMP_TAKEN_DT":"1/21/2009","CONC":".218","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"279531","CASS_NUM":"57766530","SMP_TAKEN_DT":"1/21/2009","CONC":".023","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"103519","CASS_NUM":"57766529","SMP_TAKEN_DT":"1/21/2009","CONC":".048","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"1154955","CASS_NUM":"57749437","SMP_TAKEN_DT":"6/24/2008","CONC":".11","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"946711","CASS_NUM":"57749435","SMP_TAKEN_DT":"6/24/2008","CONC":".044","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-24"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":619,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":14,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":134,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":12,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1999-09-01","lastDate":"2007-02-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":82,"firstDate":"2000-01-19","lastDate":"2009-08-25","metrics":{"inspectors":93,"recentRows":0,"onSiteHours":1419.5,"inspectionHours":2058.25,"inspectionSamples":48},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"932226","EVENT_NO":"4452875","INSPECTION_BEGIN_DT":"08/25/2009","INSPECTION_END_DT":"08/31/2009","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2009-08-25"},{"SOURCE_ROW_NUMBER":"911589","EVENT_NO":"4452858","INSPECTION_BEGIN_DT":"04/09/2009","INSPECTION_END_DT":"07/24/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"49","SUM_TOTAL_ON_SITE_HOURS":"31","sourceDate":"2009-04-09"},{"SOURCE_ROW_NUMBER":"540846","EVENT_NO":"4452853","INSPECTION_BEGIN_DT":"03/11/2009","INSPECTION_END_DT":"03/11/2009","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2009-03-11"},{"SOURCE_ROW_NUMBER":"754559","EVENT_NO":"4447808","INSPECTION_BEGIN_DT":"02/06/2009","INSPECTION_END_DT":"02/06/2009","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2009-02-06"},{"SOURCE_ROW_NUMBER":"775816","EVENT_NO":"4445672","INSPECTION_BEGIN_DT":"12/22/2008","INSPECTION_END_DT":"02/20/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"141.25","SUM_TOTAL_ON_SITE_HOURS":"102.25","sourceDate":"2008-12-22"},{"SOURCE_ROW_NUMBER":"281714","EVENT_NO":"4445541","INSPECTION_BEGIN_DT":"10/27/2008","INSPECTION_END_DT":"11/05/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17.75","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2008-10-27"},{"SOURCE_ROW_NUMBER":"1068272","EVENT_NO":"4222980","INSPECTION_BEGIN_DT":"09/04/2008","INSPECTION_END_DT":"09/04/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2008-09-04"},{"SOURCE_ROW_NUMBER":"779204","EVENT_NO":"4222962","INSPECTION_BEGIN_DT":"06/14/2008","INSPECTION_END_DT":"09/24/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"139","SUM_TOTAL_ON_SITE_HOURS":"100","sourceDate":"2008-06-14"},{"SOURCE_ROW_NUMBER":"1141205","EVENT_NO":"4222780","INSPECTION_BEGIN_DT":"02/19/2008","INSPECTION_END_DT":"03/25/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"53.25","SUM_TOTAL_ON_SITE_HOURS":"29.25","sourceDate":"2008-02-19"},{"SOURCE_ROW_NUMBER":"1158634","EVENT_NO":"4439888","INSPECTION_BEGIN_DT":"10/09/2007","INSPECTION_END_DT":"10/30/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"50","SUM_TOTAL_ON_SITE_HOURS":"37.5","sourceDate":"2007-10-09"},{"SOURCE_ROW_NUMBER":"843765","EVENT_NO":"4222934","INSPECTION_BEGIN_DT":"10/09/2007","INSPECTION_END_DT":"10/09/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2007-10-09"},{"SOURCE_ROW_NUMBER":"6668","EVENT_NO":"4441119","INSPECTION_BEGIN_DT":"02/01/2007","INSPECTION_END_DT":"03/30/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"86","SUM_TOTAL_ON_SITE_HOURS":"56","sourceDate":"2007-02-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":51,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009-Q3":{"hours":1683,"employees":8,"production":2887},"2009-Q2":{"hours":14369,"employees":36,"production":70160},"2009-Q1":{"hours":19354,"employees":41,"production":64322},"2008-Q4":{"hours":26738,"employees":43,"production":86831},"2008-Q3":{"hours":17971,"employees":36,"production":65786},"2008-Q2":{"hours":20401,"employees":34,"production":84425},"2008-Q1":{"hours":16627,"employees":34,"production":68376},"2007-Q4":{"hours":19582,"employees":34,"production":66714},"2007-Q3":{"hours":16641,"employees":34,"production":93590},"2007-Q2":{"hours":20334,"employees":32,"production":127293},"2007-Q1":{"hours":16500,"employees":34,"production":109724},"2006-Q3":{"hours":1080,"employees":4,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":36192,"employees":14,"production":81193},"2001":{"hours":83100,"employees":31,"production":210606},"2002":{"hours":127069,"employees":47,"production":299976},"2003":{"hours":157329,"employees":67,"production":876545},"2004":{"hours":203622,"employees":76,"production":989629},"2005":{"hours":206767,"employees":78,"production":912926},"2006":{"hours":24468,"employees":26,"production":57094},"2007":{"hours":73057,"employees":34,"production":397321},"2008":{"hours":81737,"employees":37,"production":305418},"2009":{"hours":35406,"employees":28,"production":137369}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":113,"firstDate":"2000-01-19","lastDate":"2009-01-21","metrics":{"recentRows":0,"doseOver100":18,"actDoseTotal":9251,"pelDoseTotal":4147},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"70140","EVENT_NO":"4445672","SURVEY_DATE":"01/21/2009","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"010","ACT_DOSE_85":"28","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"70139","EVENT_NO":"4445672","SURVEY_DATE":"01/21/2009","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"010","ACT_DOSE_85":"9","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"70138","EVENT_NO":"4445672","SURVEY_DATE":"01/21/2009","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"15","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"70137","EVENT_NO":"4445672","SURVEY_DATE":"01/21/2009","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"90","PEL_DOSE_90":"69","SURVEY_TYPE":"I","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"70136","EVENT_NO":"4445672","SURVEY_DATE":"01/21/2009","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"45","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"70032","EVENT_NO":"4222962","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"010","ACT_DOSE_85":"36","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"70031","EVENT_NO":"4222962","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"010","ACT_DOSE_85":"40","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"70030","EVENT_NO":"4222962","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"61","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"70029","EVENT_NO":"4222962","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"44","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"70028","EVENT_NO":"4222962","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"16","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"70130","EVENT_NO":"4439888","SURVEY_DATE":"10/10/2007","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"129","PEL_DOSE_90":"96","SURVEY_TYPE":"I","sourceDate":"2007-10-10"},{"SOURCE_ROW_NUMBER":"70129","EVENT_NO":"4439888","SURVEY_DATE":"10/10/2007","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"053","ACT_DOSE_85":"27","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2007-10-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":15,"firstDate":"2000-01-19","lastDate":"2005-05-02","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":37.5,"validSamples":13,"quartzPctTotal":152.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"135606","CASSETTE_NO":"57590048","SAMPLE_DT":"05/02/2005","QUARTZ_PCT":"14.4","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-05-02"},{"SOURCE_ROW_NUMBER":"107082","CASSETTE_NO":"57587818","SAMPLE_DT":"01/27/2005","QUARTZ_PCT":"05.6","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-27"},{"SOURCE_ROW_NUMBER":"139190","CASSETTE_NO":"50755023","SAMPLE_DT":"12/11/2004","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-12-11"},{"SOURCE_ROW_NUMBER":"73791","CASSETTE_NO":"57536330","SAMPLE_DT":"11/16/2004","QUARTZ_PCT":"14.3","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-11-16"},{"SOURCE_ROW_NUMBER":"148639","CASSETTE_NO":"57401711","SAMPLE_DT":"11/19/2001","QUARTZ_PCT":"00.7","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-19"},{"SOURCE_ROW_NUMBER":"68058","CASSETTE_NO":"57401735","SAMPLE_DT":"11/19/2001","QUARTZ_PCT":"01.3","OCC_CODE_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-19"},{"SOURCE_ROW_NUMBER":"9266","CASSETTE_NO":"57401729","SAMPLE_DT":"11/19/2001","QUARTZ_PCT":"20.5","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-19"},{"SOURCE_ROW_NUMBER":"5217","CASSETTE_NO":"57401731","SAMPLE_DT":"11/19/2001","QUARTZ_PCT":"02.3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-19"},{"SOURCE_ROW_NUMBER":"86798","CASSETTE_NO":"50589601","SAMPLE_DT":"04/23/2001","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2001-04-23"},{"SOURCE_ROW_NUMBER":"150255","CASSETTE_NO":"57301037","SAMPLE_DT":"04/05/2001","QUARTZ_PCT":"22.2","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-05"},{"SOURCE_ROW_NUMBER":"112055","CASSETTE_NO":"57293641","SAMPLE_DT":"10/10/2000","QUARTZ_PCT":"09.5","OCC_CODE_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-10"},{"SOURCE_ROW_NUMBER":"70273","CASSETTE_NO":"57293873","SAMPLE_DT":"10/10/2000","QUARTZ_PCT":"10.3","OCC_CODE_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-10"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":233,"firstDate":"2000-04-19","lastDate":"2009-04-09","metrics":{"ss":154,"amountDue":50756,"contested":4,"amountPaid":49242.3,"recentRows":0,"section104d":1,"unterminated":1,"proposedPenalty":50811},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"963838","VIOLATION_NO":"8339906","VIOLATION_ISSUE_DT":"04/09/2009","SIG_SUB":"N","PART_SECTION":"71.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/22/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-04-09"},{"SOURCE_ROW_NUMBER":"964048","VIOLATION_NO":"8327396","VIOLATION_ISSUE_DT":"02/10/2009","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/17/2009","PROPOSED_PENALTY":"1026","AMOUNT_DUE":"1026","AMOUNT_PAID":"1026","CONTESTED_IND":"N","sourceDate":"2009-02-10"},{"SOURCE_ROW_NUMBER":"964047","VIOLATION_NO":"8327394","VIOLATION_ISSUE_DT":"02/06/2009","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-02-06"},{"SOURCE_ROW_NUMBER":"964046","VIOLATION_NO":"8327393","VIOLATION_ISSUE_DT":"02/06/2009","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"1026","AMOUNT_DUE":"1026","AMOUNT_PAID":"1026","CONTESTED_IND":"N","sourceDate":"2009-02-06"},{"SOURCE_ROW_NUMBER":"964045","VIOLATION_NO":"8327391","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/06/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"80.65","CONTESTED_IND":"N","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"964044","VIOLATION_NO":"8327390","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"964043","VIOLATION_NO":"8327389","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"Y","PART_SECTION":"48.31(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/26/2009","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"964042","VIOLATION_NO":"8327388","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"N","PART_SECTION":"48.31(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/26/2009","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"964041","VIOLATION_NO":"8327387","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"N","PART_SECTION":"48.29(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"964040","VIOLATION_NO":"8327386","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"Y","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"190","CONTESTED_IND":"N","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"964039","VIOLATION_NO":"8327385","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"N","PART_SECTION":"77.1607(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"964038","VIOLATION_NO":"8327384","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"190","CONTESTED_IND":"N","sourceDate":"2009-01-26"}]}],"safety":{"href":"/api/v1/mines/1518202/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518202/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Bathing facilities; change rooms; sanitary flush toilet facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-E/section-71.400","part":"71","subchapter":"O","subpart":"E","id":"71.400","citation":"30 CFR 71.400","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Hazard training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.31","part":"48","subchapter":"H","subpart":"B","id":"48.31","citation":"30 CFR 48.31","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 48.29","heading":"Records of training.","id":"48.29","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.29","part":"48","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subchapter":"H","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","subpart":"B","subpartHeading":"Subpart B—Training and Retraining of Miners Working at Surface Mines and Surface Areas of Underground Mines","text":"(a) Upon a miner's completion of each MSHA approved training program, the operator shall record and certify on MSHA form 5000-23 that the miner has received the specified training. A copy of the training certificate shall be given to the miner at the completion of the training. The training certificates for each miner shall be available at the mine site for inspection by MSHA and for examination by the miners, the miners' representative and State inspection agencies. When a miner leaves the operator's employ, the miner shall be entitled to a copy of his training certificates.\n\n(b) False certification that training was given shall be punishable under section 110 (a) and (f) of the Act.\n\n(c) Copies of training certificates for currently employed miners shall be kept at the mine site for 2 years, or for 60 days after termination of employment.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[43 FR 47459, Oct. 13, 1978, as amended at 47 FR 14706, Apr. 6, 1982; 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1607","heading":"Loading and haulage equipment; operation.","id":"77.1607","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1607","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Vehicles shall follow at a safe distance; passing shall be limited to areas of adequate clearance and visibility.\n\n(b) Mobile equipment operators shall have full control of the equipment while it is in motion.\n\n(c) Equipment operating speeds shall be prudent and consistent with conditions of roadway, grades, clearance, visibility, traffic, and the type of equipment used.\n\n(d) Cabs of mobile equipment shall be kept free of extraneous materials.\n\n(e) Operators shall sit facing the direction of travel while operating equipment with dual controls.\n\n(f) When an equipment operator is present, men shall notify him before getting on or off equipment.\n\n(g) Equipment operators shall be certain, by signal or other means, that all persons are clear before starting or moving equipment.\n\n(h) Where possible, aerial tramways shall not be started until the tramway operator has ascertained that everyone is in the clear.\n\n(i) Dust control measures shall be taken where dust significantly reduces visibility of equipment operators.\n\n(j) Dippers, buckets, loading booms, or heavy suspended loads shall not be swung over the cabs of haulage vehicles until the drivers are out of the cabs and in safe locations, unless the trucks are designed specifically to protect the drivers from falling material.\n\n(k) Men shall not work or pass under the buckets or booms of loaders in operation.\n\n(l) Tires shall be deflated before repairs on them are started and adequate means shall be provided to prevent wheel locking rims from creating a hazard during tire inflation.\n\n(m) Electrically powered mobile equipment shall not be left unattended unless the master switch is in the off position, all operating controls are in the neutral position, and the brakes are set or other equivalent precautions are taken against rolling.\n\n(n) Mobile equipment shall not be left unattended unless the brakes are set. The wheels shall be turned into a bank or berm, or shall be blocked, when such equipment is parked on a grade.\n\n(o) Lights, flares, or other warning devices shall be posted when parked equipment creates a hazard to vehicular traffic.\n\n(p) Dippers, buckets, scraper blades, and similar movable parts shall be secured or lowered to the ground when not in use.\n\n(q) Shovel trailing cables shall not be moved with the shovel dipper unless cable slings or sleds are used.\n\n(r) Equipment which is to be hauled shall be loaded and protected so as to prevent sliding or spillage.\n\n(s) When moving between work areas, the equipment shall be secured in the travel position.\n\n(t) Any load extending more than 4 feet beyond the rear of the vehicle body should be marked clearly with a red flag by day and a red light at night.\n\n(u) Tow bars shall be used to tow heavy equipment and a safety chain shall be used in conjunction with each tow bar.\n\n(v) Railroad cars shall be kept under control at all times by the car dropper. Cars shall be dropped at a safe rate and in a manner that will insure that the car dropper maintains a safe position while working and traveling around the cars.\n\n(w) Railroad cars shall not be coupled or uncoupled manually from the inside of curves unless the railroad and cars are so designed to eliminate any hazard from coupling or uncoupling cars from inside of curves.\n\n(x) Persons shall wear safety belts when dropping railroad cars.\n\n(y) Railcars shall not be left on sidetracks unless ample clearance is provided for traffic on adjacent tracks.\n\n(z) Parked railcars, unless held effectively by brakes, shall be blocked securely.\n\n(aa) Railroad cars and all trucks shall be trimmed properly when they have been loaded higher than the confines of their cargo space.\n\n(bb) When the entire length of a conveyor is visible from the starting switch, the operator shall visually check to make certain that all persons are in the clear before starting the conveyor. When the entire length of the conveyor is not visible from the starting switch, a positive audible or visible warning system shall be installed and operated to warn persons that the conveyor will be started.\n\n(cc) Unguarded conveyors with walkways shall be equipped with emergency stop devices or cords along their full length.\n\n(dd) Adequate backstops or brakes shall be installed on inclined-conveyor drive units to prevent conveyors from running in reverse if a hazard to personnel would be caused.\n\n(ee) Aerial tram conveyor buckets shall not be overloaded, and feed shall be regulated to prevent spillage.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518202","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}