{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518061","name":"No 7","status":"Abandoned and Sealed","status_date":"2002-10-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Virgie","operator_id":"P22063","operator_name":"Ember Contracting Inc","controller_id":"C13803","controller_name":"Randy  Gilkerson","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.236389,"longitude":-82.676944},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":505},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518061","name":"No 7"},"operator":{"type":"operator","id":"P22063","name":"Ember Contracting Inc"},"controller":{"type":"controller","id":"C13803","name":"Randy  Gilkerson"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13803","name":"Randy  Gilkerson et al"},"object":{"type":"mine","id":"1518061","name":"No 7"},"validFrom":"1992-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518061|C13803|1992-09-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22063","name":"Ember Contracting Inc"},"object":{"type":"mine","id":"1518061","name":"No 7"},"validFrom":"1998-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518061|P22063|1998-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13803","name":"Randy  Gilkerson et al"},"object":{"type":"operator","id":"P22063","name":"Ember Contracting Inc"},"validFrom":"1998-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518061","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518061|P22063|1998-06-01|C13803|1992-09-01|91200"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":12,"firstDate":"2000-03-29","lastDate":"2002-01-02","metrics":{"daysLost":634,"injuries":12,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"147671","DOCUMENT_NO":"220020110029","ACCIDENT_DT":"01/02/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"18","NARRATIVE":"EE WAS HANGING VENTILATION CURTAINS AND A ROCK FELL FROM MINE TOP, STRIKING EE IN LEFT UPPER SIDE/BACK.","sourceDate":"2002-01-02"},{"SOURCE_ROW_NUMBER":"61551","DOCUMENT_NO":"220012540012","ACCIDENT_DT":"08/27/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"62","NARRATIVE":"EE WAS DRILLING BOLT HOLES IN ROOF TOP. STEEL GOT STUCK SO HE WAS SPINNING THE HEAD IN AN ATTEMPT TO LOOSEN STEEL, CAUGHT HIS LEFT PINKIE FINGERBETWEEN HEAD OF BOLT MACHINE AND DRILL STEEL.","sourceDate":"2001-08-27"},{"SOURCE_ROW_NUMBER":"57245","DOCUMENT_NO":"220010950018","ACCIDENT_DT":"03/26/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"EMPLOYEE WAS CLEANING RIB AREA WITH SCOOP AND SOME DEBRIS HIT HIM IN FACIAL AREA.","sourceDate":"2001-03-26"},{"SOURCE_ROW_NUMBER":"61550","DOCUMENT_NO":"220010430120","ACCIDENT_DT":"02/07/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"349","NARRATIVE":"EE WAS BOLTING ROOF TOP WHEN A PIECE OF SANDSTONE SLUG FELL FROM BETWEEN 2 ROOF BOLTS STRIKING EE IN LOWER BACK AREA.","sourceDate":"2001-02-07"},{"SOURCE_ROW_NUMBER":"212174","DOCUMENT_NO":"220010120008","ACCIDENT_DT":"01/03/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"EE WAS ASSISTING IN REPLACING A BELT ON THE BELTLINE AND CAUGHT HIS HAND BETWEEN A BEARING AND ROLLER.","sourceDate":"2001-01-03"},{"SOURCE_ROW_NUMBER":"35815","DOCUMENT_NO":"220003390095","ACCIDENT_DT":"11/22/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE WAS OPERATING SCOOP AND TRAVELING DOWN GRADE. HE STATED THAT HE BEGAN TO SLIDE INSIDE OF SCOOP AND REACHED OUT TO HOLD ONTO SCOOP AND CAUGHT THE TIPS OF HIS FINGERS.","sourceDate":"2000-11-22"},{"SOURCE_ROW_NUMBER":"177764","DOCUMENT_NO":"220003250100","ACCIDENT_DT":"10/21/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"142","NARRATIVE":"EE STATED THAT HE WAS HELPING TO CHANGE BELT STRUCTURE AND WHILE DOING SO, THAT HIS LEFT KNEE POPPED.","sourceDate":"2000-10-21"},{"SOURCE_ROW_NUMBER":"169122","DOCUMENT_NO":"220002690065","ACCIDENT_DT":"09/21/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"51","NARRATIVE":"EMPLOYEE WAS BOLTING ROOF TOP IN #5 ENTRY. THE ROOF BOLT CAME BACK OUT, CAUSING INJURY TO LEFT HAND.","sourceDate":"2000-09-21"},{"SOURCE_ROW_NUMBER":"203523","DOCUMENT_NO":"220002060063","ACCIDENT_DT":"07/12/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EMPLOYEE STATED THAT HE HAD WENT TO BATTERY STATION TO REPLACE BATTERIES. HE SAID THAT HE HOPPED OFF SIDE OF SCOOP AND THAT HE STARTED FEELING PAIN IN LOWER AND UPPER BACK. HE SAID THAT HE MUS T HAVE LANDED WRONG.","sourceDate":"2000-07-12"},{"SOURCE_ROW_NUMBER":"259603","DOCUMENT_NO":"220001300009","ACCIDENT_DT":"04/27/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE STATED THAT HE HAD BEEN BOLTING ROOF TOP IN #6 HEADING. HE HAD WENT TO LOAD GIVE ON BUGGY AND BUMPED HIS HEAD AGAINST LOW SPOT IN ROOF TOP.","sourceDate":"2000-04-27"},{"SOURCE_ROW_NUMBER":"61552","DOCUMENT_NO":"220001150113","ACCIDENT_DT":"04/14/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","NARRATIVE":"EE WAS UNLOADING BELT STRUCTURE AND CUT HIS FINGER.","sourceDate":"2000-04-14"},{"SOURCE_ROW_NUMBER":"78840","DOCUMENT_NO":"220001040023","ACCIDENT_DT":"03/29/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"EE STATED THAT HE WAS BOLTING ROOF TOP IN #2 HEADING WHEN HIS LEGS SLIPPED OUT FROM UNDER HIM CAUSING HIM TO STRETCH GROIN MUSCLE.","sourceDate":"2000-03-29"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-10-16","lastDate":"2002-10-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":74,"firstDate":"2000-02-09","lastDate":"2002-08-26","metrics":{"ss":42,"delinquent":74,"recentRows":0,"paidPenalty":9988,"proposedPenalty":9988,"currentAssessment":9988},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"988293","VIOLATION_NO":"7390985","ISSUE_DT":"08/26/2002","CFR_STANDARD_CD":"75.360(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-26"},{"SOURCE_ROW_NUMBER":"988224","VIOLATION_NO":"7388468","ISSUE_DT":"05/21/2002","CFR_STANDARD_CD":"75.523","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"196.00","CURRENT_ASSESSMENT_AMT":"196.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"988223","VIOLATION_NO":"7388467","ISSUE_DT":"05/21/2002","CFR_STANDARD_CD":"75.1714-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"988222","VIOLATION_NO":"7388459","ISSUE_DT":"05/08/2002","CFR_STANDARD_CD":"75.383(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"956500","VIOLATION_NO":"7388934","ISSUE_DT":"03/14/2002","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-14"},{"SOURCE_ROW_NUMBER":"956499","VIOLATION_NO":"7388933","ISSUE_DT":"03/14/2002","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-14"},{"SOURCE_ROW_NUMBER":"956477","VIOLATION_NO":"4013989","ISSUE_DT":"11/07/2001","CFR_STANDARD_CD":"75.902","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"161.00","CURRENT_ASSESSMENT_AMT":"161.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"956476","VIOLATION_NO":"4013988","ISSUE_DT":"11/07/2001","CFR_STANDARD_CD":"75.900","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"161.00","CURRENT_ASSESSMENT_AMT":"161.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"956475","VIOLATION_NO":"4013987","ISSUE_DT":"11/06/2001","CFR_STANDARD_CD":"75.900","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-06"},{"SOURCE_ROW_NUMBER":"956474","VIOLATION_NO":"4013986","ISSUE_DT":"11/06/2001","CFR_STANDARD_CD":"75.900","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"161.00","CURRENT_ASSESSMENT_AMT":"161.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-06"},{"SOURCE_ROW_NUMBER":"956473","VIOLATION_NO":"4013985","ISSUE_DT":"11/06/2001","CFR_STANDARD_CD":"75.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-06"},{"SOURCE_ROW_NUMBER":"956478","VIOLATION_NO":"7377818","ISSUE_DT":"10/29/2001","CFR_STANDARD_CD":"75.1715","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-10-29"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":224,"firstDate":"2000-01-03","lastDate":"2002-07-19","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":2,"validSamples":222,"maxConcentration":3.487,"concentrationTotal":157.863},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1651147","CASS_NUM":"50660188","SMP_TAKEN_DT":"7/19/2002","CONC":".451","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-19"},{"SOURCE_ROW_NUMBER":"578616","CASS_NUM":"50660178","SMP_TAKEN_DT":"7/18/2002","CONC":"1","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-18"},{"SOURCE_ROW_NUMBER":"1059865","CASS_NUM":"50660190","SMP_TAKEN_DT":"7/17/2002","CONC":".915","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-17"},{"SOURCE_ROW_NUMBER":"243148","CASS_NUM":"50607435","SMP_TAKEN_DT":"7/16/2002","CONC":".48","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-16"},{"SOURCE_ROW_NUMBER":"1548571","CASS_NUM":"50607436","SMP_TAKEN_DT":"7/15/2002","CONC":".945","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-15"},{"SOURCE_ROW_NUMBER":"380044","CASS_NUM":"50635310","SMP_TAKEN_DT":"7/15/2002","CONC":".51","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-15"},{"SOURCE_ROW_NUMBER":"1362846","CASS_NUM":"57421821","SMP_TAKEN_DT":"7/9/2002","CONC":".717","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"956535","CASS_NUM":"57421936","SMP_TAKEN_DT":"7/9/2002","CONC":".693","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"951212","CASS_NUM":"57421818","SMP_TAKEN_DT":"7/9/2002","CONC":"1.045","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BLASTER/SHOOTER/SHOTFIRER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"886826","CASS_NUM":"57421925","SMP_TAKEN_DT":"7/9/2002","CONC":".467","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"590602","CASS_NUM":"57421932","SMP_TAKEN_DT":"7/9/2002","CONC":".398","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"335286","CASS_NUM":"57421939","SMP_TAKEN_DT":"7/9/2002","CONC":".678","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-09"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2000-12-06","lastDate":"2000-12-06","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1998-06-01","lastDate":"1998-06-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":43,"firstDate":"2000-01-03","lastDate":"2002-10-07","metrics":{"inspectors":57,"recentRows":0,"onSiteHours":619.25,"inspectionHours":984.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"513496","EVENT_NO":"4179626","INSPECTION_BEGIN_DT":"10/07/2002","INSPECTION_END_DT":"10/16/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"684948","EVENT_NO":"4179619","INSPECTION_BEGIN_DT":"07/03/2002","INSPECTION_END_DT":"08/28/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"21","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"473357","EVENT_NO":"4167745","INSPECTION_BEGIN_DT":"07/01/2002","INSPECTION_END_DT":"07/29/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15.5","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2002-07-01"},{"SOURCE_ROW_NUMBER":"739317","EVENT_NO":"4179682","INSPECTION_BEGIN_DT":"05/07/2002","INSPECTION_END_DT":"05/09/2002","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2002-05-07"},{"SOURCE_ROW_NUMBER":"548192","EVENT_NO":"4179613","INSPECTION_BEGIN_DT":"04/29/2002","INSPECTION_END_DT":"05/16/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2002-04-29"},{"SOURCE_ROW_NUMBER":"535583","EVENT_NO":"4179608","INSPECTION_BEGIN_DT":"04/10/2002","INSPECTION_END_DT":"06/25/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"60.75","SUM_TOTAL_ON_SITE_HOURS":"40","sourceDate":"2002-04-10"},{"SOURCE_ROW_NUMBER":"929803","EVENT_NO":"4179605","INSPECTION_BEGIN_DT":"03/28/2002","INSPECTION_END_DT":"04/03/2002","ACTIVITY_CODE":"BBF","ACTIVITY":"PART 50 AUDITS","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"31","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2002-03-28"},{"SOURCE_ROW_NUMBER":"550545","EVENT_NO":"4179658","INSPECTION_BEGIN_DT":"02/14/2002","INSPECTION_END_DT":"03/04/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2002-02-14"},{"SOURCE_ROW_NUMBER":"700957","EVENT_NO":"4167830","INSPECTION_BEGIN_DT":"01/09/2002","INSPECTION_END_DT":"01/23/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2002-01-09"},{"SOURCE_ROW_NUMBER":"657350","EVENT_NO":"4167831","INSPECTION_BEGIN_DT":"01/09/2002","INSPECTION_END_DT":"03/25/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"45.5","SUM_TOTAL_ON_SITE_HOURS":"28","sourceDate":"2002-01-09"},{"SOURCE_ROW_NUMBER":"507259","EVENT_NO":"4167828","INSPECTION_BEGIN_DT":"12/18/2001","INSPECTION_END_DT":"01/09/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"374780","EVENT_NO":"4167824","INSPECTION_BEGIN_DT":"11/13/2001","INSPECTION_END_DT":"11/26/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2001-11-13"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":0,"employees":0,"production":0},"2002-Q3":{"hours":6593,"employees":23,"production":30961},"2002-Q2":{"hours":14161,"employees":23,"production":84667},"2002-Q1":{"hours":14831,"employees":23,"production":93772},"2001-Q4":{"hours":11711,"employees":22,"production":71993},"2001-Q3":{"hours":12445,"employees":25,"production":86160},"2001-Q2":{"hours":12578,"employees":23,"production":83102},"2001-Q1":{"hours":10883,"employees":18,"production":59114},"2000-Q4":{"hours":12787,"employees":24,"production":60072},"2000-Q3":{"hours":13379,"employees":24,"production":70558},"2000-Q2":{"hours":14897,"employees":25,"production":71793},"2000-Q1":{"hours":15136,"employees":25,"production":65648}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":56199,"employees":25,"production":268071},"2001":{"hours":47617,"employees":22,"production":300369},"2002":{"hours":35585,"employees":23,"production":209400}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":9,"firstDate":"2000-02-09","lastDate":"2002-05-08","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":665,"pelDoseTotal":394},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"67586","EVENT_NO":"4179682","SURVEY_DATE":"05/08/2002","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"120","ACT_DOSE_85":"50","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"67585","EVENT_NO":"4179682","SURVEY_DATE":"05/08/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"73","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"67584","EVENT_NO":"4179682","SURVEY_DATE":"05/08/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"40","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"67583","EVENT_NO":"4179682","SURVEY_DATE":"05/08/2002","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"100","ACT_DOSE_85":"62","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"67582","EVENT_NO":"4179682","SURVEY_DATE":"05/08/2002","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"96","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"67590","EVENT_NO":"6144923","SURVEY_DATE":"02/09/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"101","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2000-02-09"},{"SOURCE_ROW_NUMBER":"67589","EVENT_NO":"6144923","SURVEY_DATE":"02/09/2000","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"120","ACT_DOSE_85":"107","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2000-02-09"},{"SOURCE_ROW_NUMBER":"67588","EVENT_NO":"6144923","SURVEY_DATE":"02/09/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"35","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2000-02-09"},{"SOURCE_ROW_NUMBER":"67587","EVENT_NO":"6144923","SURVEY_DATE":"02/09/2000","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"101","PEL_DOSE_90":"61","SURVEY_TYPE":"I","sourceDate":"2000-02-09"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":35,"firstDate":"2000-02-09","lastDate":"2002-07-09","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":7,"validSamples":35,"quartzPctTotal":129.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"127811","CASSETTE_NO":"57421936","SAMPLE_DT":"07/09/2002","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"64960","CASSETTE_NO":"57421821","SAMPLE_DT":"07/09/2002","QUARTZ_PCT":"03.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"162101","CASSETTE_NO":"57411721","SAMPLE_DT":"05/08/2002","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"94284","CASSETTE_NO":"57411814","SAMPLE_DT":"05/08/2002","QUARTZ_PCT":"04.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"82686","CASSETTE_NO":"57411843","SAMPLE_DT":"05/08/2002","QUARTZ_PCT":"03.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"151052","CASSETTE_NO":"57390350","SAMPLE_DT":"02/19/2002","QUARTZ_PCT":"03.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-19"},{"SOURCE_ROW_NUMBER":"4141","CASSETTE_NO":"57390363","SAMPLE_DT":"02/19/2002","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-19"},{"SOURCE_ROW_NUMBER":"156649","CASSETTE_NO":"57385292","SAMPLE_DT":"12/18/2001","QUARTZ_PCT":"02.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"118349","CASSETTE_NO":"57385287","SAMPLE_DT":"12/18/2001","QUARTZ_PCT":"02.0","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"8788","CASSETTE_NO":"57385336","SAMPLE_DT":"12/18/2001","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"76316","CASSETTE_NO":"57385190","SAMPLE_DT":"11/13/2001","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-13"},{"SOURCE_ROW_NUMBER":"21490","CASSETTE_NO":"57385226","SAMPLE_DT":"11/13/2001","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-13"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":74,"firstDate":"2000-02-09","lastDate":"2002-08-26","metrics":{"ss":42,"amountDue":9988,"contested":0,"amountPaid":9988,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":9988},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"946559","VIOLATION_NO":"7390985","VIOLATION_ISSUE_DT":"08/26/2002","SIG_SUB":"N","PART_SECTION":"75.360(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/26/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-08-26"},{"SOURCE_ROW_NUMBER":"946549","VIOLATION_NO":"7388468","VIOLATION_ISSUE_DT":"05/21/2002","SIG_SUB":"Y","PART_SECTION":"75.523","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2002","PROPOSED_PENALTY":"196","AMOUNT_DUE":"196","AMOUNT_PAID":"196","CONTESTED_IND":"N","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"946548","VIOLATION_NO":"7388467","VIOLATION_ISSUE_DT":"05/21/2002","SIG_SUB":"N","PART_SECTION":"75.1714-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/29/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"946547","VIOLATION_NO":"7388459","VIOLATION_ISSUE_DT":"05/08/2002","SIG_SUB":"N","PART_SECTION":"75.383(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-05-08"},{"SOURCE_ROW_NUMBER":"946530","VIOLATION_NO":"7388934","VIOLATION_ISSUE_DT":"03/14/2002","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/14/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-03-14"},{"SOURCE_ROW_NUMBER":"946529","VIOLATION_NO":"7388933","VIOLATION_ISSUE_DT":"03/14/2002","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/14/2002","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"224","CONTESTED_IND":"N","sourceDate":"2002-03-14"},{"SOURCE_ROW_NUMBER":"946590","VIOLATION_NO":"4013989","VIOLATION_ISSUE_DT":"11/07/2001","SIG_SUB":"Y","PART_SECTION":"75.902","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/07/2001","PROPOSED_PENALTY":"161","AMOUNT_DUE":"161","AMOUNT_PAID":"161","CONTESTED_IND":"N","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"946589","VIOLATION_NO":"4013988","VIOLATION_ISSUE_DT":"11/07/2001","SIG_SUB":"Y","PART_SECTION":"75.900","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/08/2001","PROPOSED_PENALTY":"161","AMOUNT_DUE":"161","AMOUNT_PAID":"161","CONTESTED_IND":"N","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"946588","VIOLATION_NO":"4013987","VIOLATION_ISSUE_DT":"11/06/2001","SIG_SUB":"N","PART_SECTION":"75.900","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/07/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-06"},{"SOURCE_ROW_NUMBER":"946587","VIOLATION_NO":"4013986","VIOLATION_ISSUE_DT":"11/06/2001","SIG_SUB":"Y","PART_SECTION":"75.900","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/06/2001","PROPOSED_PENALTY":"161","AMOUNT_DUE":"161","AMOUNT_PAID":"161","CONTESTED_IND":"N","sourceDate":"2001-11-06"},{"SOURCE_ROW_NUMBER":"946586","VIOLATION_NO":"4013985","VIOLATION_ISSUE_DT":"11/06/2001","SIG_SUB":"N","PART_SECTION":"75.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/06/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-06"},{"SOURCE_ROW_NUMBER":"946591","VIOLATION_NO":"7377818","VIOLATION_ISSUE_DT":"10/29/2001","SIG_SUB":"N","PART_SECTION":"75.1715","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/29/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-10-29"}]}],"safety":{"href":"/api/v1/mines/1518061/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518061/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","heading":"Electric face equipment; deenergization.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523","part":"75","subchapter":"O","subpart":"F","id":"75.523","citation":"30 CFR 75.523","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","heading":"Low- and medium-voltage ground check monitor circuits.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.902","part":"75","subchapter":"O","subpart":"J","id":"75.902","citation":"30 CFR 75.902","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.900","heading":"Low- and medium-voltage circuits serving three-phase alternating current equipment; circuit breakers.","id":"75.900","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.900","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nLow- and medium-voltage power circuits serving three-phase alternating current equipment shall be protected by suitable circuit breakers of adequate interrupting capacity which are properly tested and maintained as prescribed by the Secretary. Such breakers shall be equipped with devices to provide protection against undervoltage, grounded phase, short circuit, and overcurrent.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.701","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","id":"75.701","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-H/section-75.701","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"H","subpartHeading":"Subpart H—Grounding","text":"[Statutory Provisions]\n\nMetallic frames, casings, and other enclosures of electric equipment that can become “alive” through failure of insulation or by contact with energized parts shall be grounded by methods approved by an authorized representative of the Secretary.","occurrenceCount":1},{"chapter":"I","heading":"Identification check system.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1715","part":"75","subchapter":"O","subpart":"R","id":"75.1715","citation":"30 CFR 75.1715","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518061","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}