{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518031","name":"Mine #3","status":"Abandoned and Sealed","status_date":"2005-05-27","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Fedscreek","operator_id":"P23119","operator_name":"Dry Fork Energy Inc","controller_id":"C12979","controller_name":"Kenneth L  Farley","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.425,"longitude":-82.25},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":863},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518031","name":"Mine #3"},"operator":{"type":"operator","id":"P23119","name":"Dry Fork Energy Inc"},"controller":{"type":"controller","id":"C12979","name":"Kenneth L  Farley"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12979","name":"Kenneth L  Farley et al"},"object":{"type":"mine","id":"1518031","name":"Mine #3"},"validFrom":"1995-05-24","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518031|C12979|1995-05-24|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15641","name":"Dirk  Johnson"},"object":{"type":"mine","id":"1518031","name":"Mine #3"},"validFrom":"1997-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518031|C15641|1997-09-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23834","name":"Tycoby Fuels Corp"},"object":{"type":"mine","id":"1518031","name":"Mine #3"},"validFrom":"1998-03-01","validTo":"1999-05-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518031|P23834|1998-03-01|1999-05-19"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15641","name":"Dirk  Johnson"},"object":{"type":"operator","id":"P23834","name":"Tycoby Fuels Corp"},"validFrom":"1998-03-01","validTo":"1999-05-19","current":false,"derived":true,"evidenceMineId":"1518031","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518031|P23834|1998-03-01|C15641|1997-09-01|96401"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23119","name":"Dry Fork Energy Inc"},"object":{"type":"mine","id":"1518031","name":"Mine #3"},"validFrom":"1999-05-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518031|P23119|1999-05-20|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12979","name":"Kenneth L  Farley et al"},"object":{"type":"operator","id":"P23119","name":"Dry Fork Energy Inc"},"validFrom":"1999-05-20","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518031","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518031|P23119|1999-05-20|C12979|1995-05-24|88305"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2000-08-28","lastDate":"2001-05-30","metrics":{"daysLost":119,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":6,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"151957","DOCUMENT_NO":"220011690092","ACCIDENT_DT":"05/30/2001","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"THE OPERATOR OF A SHUTTLE CAR REACHED HIS LEFT HAND OUT TO HOLD UP A CABLE AS HIS CAR WENT AROUND A CORNER AND HE STRUCK THE CAR FRAME WITH THE BACK OF HIS LEFT HAND.","sourceDate":"2001-05-30"},{"SOURCE_ROW_NUMBER":"108635","DOCUMENT_NO":"220010570133","ACCIDENT_DT":"09/13/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","NARRATIVE":"TRYING TO LINE A STAB JACK UP ON JOY MINER TO BEABLE TO WELD ON IT AND IT SLID OFF CRIB BLOCK ONTO SHOULDER","sourceDate":"2000-09-13"},{"SOURCE_ROW_NUMBER":"139027","DOCUMENT_NO":"220010570134","ACCIDENT_DT":"08/28/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"118","NARRATIVE":"EE WAS OPERATING HIS SHUTTLE CAR WHEN A PIECE OF ROCK FELL & STRUCK HIS HARD HAT/SHOULDER & FOREARM","sourceDate":"2000-08-28"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2005-05-27","lastDate":"2005-05-27","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":119,"firstDate":"2000-02-16","lastDate":"2002-10-31","metrics":{"ss":61,"delinquent":119,"recentRows":0,"paidPenalty":9475.02,"proposedPenalty":10643,"currentAssessment":10643},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"942124","VIOLATION_NO":"7394496","ISSUE_DT":"10/31/2002","CFR_STANDARD_CD":"75.514","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"140.00","CURRENT_ASSESSMENT_AMT":"140.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-10-31"},{"SOURCE_ROW_NUMBER":"942125","VIOLATION_NO":"9982678","ISSUE_DT":"10/04/2002","CFR_STANDARD_CD":"70.101","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-10-04"},{"SOURCE_ROW_NUMBER":"941636","VIOLATION_NO":"7390026","ISSUE_DT":"09/05/2002","CFR_STANDARD_CD":"75.1103-4","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-05"},{"SOURCE_ROW_NUMBER":"941635","VIOLATION_NO":"7390025","ISSUE_DT":"09/05/2002","CFR_STANDARD_CD":"75.1102","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-05"},{"SOURCE_ROW_NUMBER":"941634","VIOLATION_NO":"7390024","ISSUE_DT":"08/29/2002","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"941633","VIOLATION_NO":"7390023","ISSUE_DT":"08/29/2002","CFR_STANDARD_CD":"75.523-3","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"941632","VIOLATION_NO":"7390022","ISSUE_DT":"08/29/2002","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"941631","VIOLATION_NO":"7389478","ISSUE_DT":"08/12/2002","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"941630","VIOLATION_NO":"7389477","ISSUE_DT":"08/12/2002","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"941623","VIOLATION_NO":"4237602","ISSUE_DT":"07/31/2002","CFR_STANDARD_CD":"75.370","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-31"},{"SOURCE_ROW_NUMBER":"941629","VIOLATION_NO":"7389472","ISSUE_DT":"07/24/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-24"},{"SOURCE_ROW_NUMBER":"941628","VIOLATION_NO":"7389471","ISSUE_DT":"07/19/2002","CFR_STANDARD_CD":"75.1719-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-19"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":391,"firstDate":"2000-01-11","lastDate":"2002-09-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":36,"validSamples":355,"maxConcentration":7.677,"concentrationTotal":158.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"621059","CASS_NUM":"50676325","SMP_TAKEN_DT":"9/25/2002","CONC":".017","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-25"},{"SOURCE_ROW_NUMBER":"423137","CASS_NUM":"50676313","SMP_TAKEN_DT":"9/25/2002","CONC":".78","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-25"},{"SOURCE_ROW_NUMBER":"326764","CASS_NUM":"50676330","SMP_TAKEN_DT":"9/25/2002","CONC":".021","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-25"},{"SOURCE_ROW_NUMBER":"1559074","CASS_NUM":"50676321","SMP_TAKEN_DT":"9/24/2002","CONC":".562","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-24"},{"SOURCE_ROW_NUMBER":"32758","CASS_NUM":"50676332","SMP_TAKEN_DT":"9/24/2002","CONC":"1.854","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-24"},{"SOURCE_ROW_NUMBER":"1093426","CASS_NUM":"50676303","SMP_TAKEN_DT":"9/23/2002","CONC":"1.553","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-23"},{"SOURCE_ROW_NUMBER":"453296","CASS_NUM":"50676316","SMP_TAKEN_DT":"9/23/2002","CONC":"1.305","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-23"},{"SOURCE_ROW_NUMBER":"995266","CASS_NUM":"50676318","SMP_TAKEN_DT":"9/20/2002","CONC":"1.418","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-20"},{"SOURCE_ROW_NUMBER":"42920","CASS_NUM":"50676300","SMP_TAKEN_DT":"9/20/2002","CONC":"1.923","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-20"},{"SOURCE_ROW_NUMBER":"1384538","CASS_NUM":"50676296","SMP_TAKEN_DT":"9/18/2002","CONC":".945","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-18"},{"SOURCE_ROW_NUMBER":"135153","CASS_NUM":"50676302","SMP_TAKEN_DT":"9/18/2002","CONC":"7.677","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-18"},{"SOURCE_ROW_NUMBER":"992018","CASS_NUM":"50673764","SMP_TAKEN_DT":"8/29/2002","CONC":".163","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-29"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":61,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1998-03-01","lastDate":"1999-05-20","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":56,"firstDate":"2000-01-06","lastDate":"2005-03-23","metrics":{"inspectors":78,"recentRows":0,"onSiteHours":1108,"inspectionHours":1607,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"686483","EVENT_NO":"4177118","INSPECTION_BEGIN_DT":"03/23/2005","INSPECTION_END_DT":"03/23/2005","ACTIVITY_CODE":"CFC","ACTIVITY":"OTHER CONTACTS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2005-03-23"},{"SOURCE_ROW_NUMBER":"769887","EVENT_NO":"4176776","INSPECTION_BEGIN_DT":"12/29/2004","INSPECTION_END_DT":"12/29/2004","ACTIVITY_CODE":"CFC","ACTIVITY":"OTHER CONTACTS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"979433","EVENT_NO":"4176664","INSPECTION_BEGIN_DT":"08/20/2004","INSPECTION_END_DT":"08/20/2004","ACTIVITY_CODE":"CFC","ACTIVITY":"OTHER CONTACTS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2004-08-20"},{"SOURCE_ROW_NUMBER":"727484","EVENT_NO":"4176657","INSPECTION_BEGIN_DT":"05/21/2004","INSPECTION_END_DT":"05/21/2004","ACTIVITY_CODE":"CFC","ACTIVITY":"OTHER CONTACTS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2004-05-21"},{"SOURCE_ROW_NUMBER":"274317","EVENT_NO":"4176136","INSPECTION_BEGIN_DT":"03/11/2004","INSPECTION_END_DT":"03/11/2004","ACTIVITY_CODE":"CFC","ACTIVITY":"OTHER CONTACTS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2004-03-11"},{"SOURCE_ROW_NUMBER":"792529","EVENT_NO":"4176120","INSPECTION_BEGIN_DT":"12/18/2003","INSPECTION_END_DT":"12/24/2003","ACTIVITY_CODE":"CFC","ACTIVITY":"OTHER CONTACTS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2003-12-18"},{"SOURCE_ROW_NUMBER":"922680","EVENT_NO":"4176015","INSPECTION_BEGIN_DT":"09/23/2003","INSPECTION_END_DT":"09/26/2003","ACTIVITY_CODE":"CFC","ACTIVITY":"OTHER CONTACTS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2003-09-23"},{"SOURCE_ROW_NUMBER":"930504","EVENT_NO":"4176004","INSPECTION_BEGIN_DT":"04/03/2003","INSPECTION_END_DT":"04/08/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2003-04-03"},{"SOURCE_ROW_NUMBER":"654919","EVENT_NO":"4162818","INSPECTION_BEGIN_DT":"02/07/2003","INSPECTION_END_DT":"02/07/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2003-02-07"},{"SOURCE_ROW_NUMBER":"3919","EVENT_NO":"4161937","INSPECTION_BEGIN_DT":"10/01/2002","INSPECTION_END_DT":"11/21/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"44","SUM_TOTAL_ON_SITE_HOURS":"20","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"916536","EVENT_NO":"4161936","INSPECTION_BEGIN_DT":"08/20/2002","INSPECTION_END_DT":"09/04/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"36","SUM_TOTAL_ON_SITE_HOURS":"20.5","sourceDate":"2002-08-20"},{"SOURCE_ROW_NUMBER":"1027717","EVENT_NO":"4161676","INSPECTION_BEGIN_DT":"07/01/2002","INSPECTION_END_DT":"09/30/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"128","SUM_TOTAL_ON_SITE_HOURS":"97","sourceDate":"2002-07-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":30,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005-Q2":{"hours":0,"employees":0,"production":0},"2003-Q2":{"hours":0,"employees":0,"production":0},"2003-Q1":{"hours":0,"employees":0,"production":0},"2002-Q4":{"hours":3776,"employees":37,"production":1183},"2002-Q3":{"hours":19459,"employees":38,"production":18359},"2002-Q2":{"hours":19127,"employees":38,"production":36228},"2002-Q1":{"hours":19036,"employees":38,"production":40703},"2001-Q4":{"hours":21661,"employees":36,"production":32988},"2001-Q3":{"hours":19054,"employees":37,"production":34689},"2001-Q2":{"hours":19664,"employees":34,"production":30652},"2001-Q1":{"hours":16466,"employees":34,"production":33940},"2000-Q4":{"hours":16128,"employees":34,"production":30840}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":75094,"employees":36,"production":167423},"2001":{"hours":76845,"employees":36,"production":132269},"2002":{"hours":61398,"employees":38,"production":96473}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":33,"firstDate":"2000-01-11","lastDate":"2002-05-23","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":1716,"pelDoseTotal":1211},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"67016","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"168","PEL_DOSE_90":"148","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67015","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"40","PEL_DOSE_90":"24","SURVEY_TYPE":"F","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67014","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"12","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67013","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"66","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67012","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"47","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67011","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67010","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"73","PEL_DOSE_90":"61","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67009","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"14","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67008","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"43","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67007","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"059","ACT_DOSE_85":"69","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67006","EVENT_NO":"4162544","SURVEY_DATE":"05/23/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"059","ACT_DOSE_85":"78","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"67005","EVENT_NO":"4161854","SURVEY_DATE":"12/21/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2000-12-21"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":25,"firstDate":"2000-02-22","lastDate":"2002-08-22","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":11.7,"validSamples":25,"quartzPctTotal":151.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"59260","CASSETTE_NO":"57389894","SAMPLE_DT":"08/22/2002","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-08-22"},{"SOURCE_ROW_NUMBER":"148954","CASSETTE_NO":"57398259","SAMPLE_DT":"05/01/2002","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-01"},{"SOURCE_ROW_NUMBER":"35119","CASSETTE_NO":"57398567","SAMPLE_DT":"05/01/2002","QUARTZ_PCT":"07.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-01"},{"SOURCE_ROW_NUMBER":"60307","CASSETTE_NO":"57398570","SAMPLE_DT":"03/19/2002","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-19"},{"SOURCE_ROW_NUMBER":"70915","CASSETTE_NO":"57385787","SAMPLE_DT":"01/08/2002","QUARTZ_PCT":"03.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-08"},{"SOURCE_ROW_NUMBER":"10131","CASSETTE_NO":"57385727","SAMPLE_DT":"01/08/2002","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-08"},{"SOURCE_ROW_NUMBER":"2187","CASSETTE_NO":"57385768","SAMPLE_DT":"01/08/2002","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-08"},{"SOURCE_ROW_NUMBER":"143685","CASSETTE_NO":"57345696","SAMPLE_DT":"11/05/2001","QUARTZ_PCT":"11.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-05"},{"SOURCE_ROW_NUMBER":"15844","CASSETTE_NO":"57345695","SAMPLE_DT":"11/05/2001","QUARTZ_PCT":"05.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-05"},{"SOURCE_ROW_NUMBER":"63766","CASSETTE_NO":"57363633","SAMPLE_DT":"08/28/2001","QUARTZ_PCT":"07.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-08-28"},{"SOURCE_ROW_NUMBER":"91660","CASSETTE_NO":"57363165","SAMPLE_DT":"06/26/2001","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-26"},{"SOURCE_ROW_NUMBER":"120720","CASSETTE_NO":"57324515","SAMPLE_DT":"04/16/2001","QUARTZ_PCT":"06.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-16"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":119,"firstDate":"2000-02-16","lastDate":"2002-10-31","metrics":{"ss":61,"amountDue":10643,"contested":0,"amountPaid":9475.02,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":10643},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"943399","VIOLATION_NO":"7394496","VIOLATION_ISSUE_DT":"10/31/2002","SIG_SUB":"Y","PART_SECTION":"75.514","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/31/2002","PROPOSED_PENALTY":"140","AMOUNT_DUE":"140","AMOUNT_PAID":"140","CONTESTED_IND":"N","sourceDate":"2002-10-31"},{"SOURCE_ROW_NUMBER":"943400","VIOLATION_NO":"9982678","VIOLATION_ISSUE_DT":"10/04/2002","SIG_SUB":"Y","PART_SECTION":"70.101","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/29/2002","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2002-10-04"},{"SOURCE_ROW_NUMBER":"943378","VIOLATION_NO":"7390026","VIOLATION_ISSUE_DT":"09/05/2002","SIG_SUB":"N","PART_SECTION":"75.1103-4","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-09-05"},{"SOURCE_ROW_NUMBER":"943377","VIOLATION_NO":"7390025","VIOLATION_ISSUE_DT":"09/05/2002","SIG_SUB":"Y","PART_SECTION":"75.1102","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2002","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2002-09-05"},{"SOURCE_ROW_NUMBER":"943376","VIOLATION_NO":"7390024","VIOLATION_ISSUE_DT":"08/29/2002","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/04/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"943375","VIOLATION_NO":"7390023","VIOLATION_ISSUE_DT":"08/29/2002","SIG_SUB":"Y","PART_SECTION":"75.523-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/04/2002","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"943374","VIOLATION_NO":"7390022","VIOLATION_ISSUE_DT":"08/29/2002","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/04/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"943373","VIOLATION_NO":"7389478","VIOLATION_ISSUE_DT":"08/12/2002","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/12/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"943372","VIOLATION_NO":"7389477","VIOLATION_ISSUE_DT":"08/12/2002","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/12/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"943365","VIOLATION_NO":"4237602","VIOLATION_ISSUE_DT":"07/31/2002","SIG_SUB":"N","PART_SECTION":"75.370","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-07-31"},{"SOURCE_ROW_NUMBER":"943371","VIOLATION_NO":"7389472","VIOLATION_ISSUE_DT":"07/24/2002","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/29/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"54.99","CONTESTED_IND":"N","sourceDate":"2002-07-24"},{"SOURCE_ROW_NUMBER":"943370","VIOLATION_NO":"7389471","VIOLATION_ISSUE_DT":"07/19/2002","SIG_SUB":"N","PART_SECTION":"75.1719-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/29/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-07-19"}]}],"safety":{"href":"/api/v1/mines/1518031/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518031/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Electrical connections or splices; suitability.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.514","part":"75","subchapter":"O","subpart":"F","id":"75.514","citation":"30 CFR 75.514","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"[Reserved]","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-B/section-70.101","part":"70","subchapter":"O","subpart":"B","id":"70.101","citation":"30 CFR 70.101","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Slippage and sequence switches.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1102","part":"75","subchapter":"O","subpart":"L","id":"75.1102","citation":"30 CFR 75.1102","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Illumination in working places.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1719-1","part":"75","subchapter":"O","subpart":"R","id":"75.1719-1","citation":"30 CFR 75.1719-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518031","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}