{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518026","name":"No. 5","status":"Abandoned and Sealed","status_date":"2012-05-11","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Martin","nearest_town":"Lovely","operator_id":"P15627","operator_name":"Coalburg Enterprises, Inc.","controller_id":"C11194","controller_name":"James H  Booth","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.9625,"longitude":-82.588333},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":666},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518026","name":"No. 5"},"operator":{"type":"operator","id":"P15627","name":"Coalburg Enterprises, Inc."},"controller":{"type":"controller","id":"C11194","name":"James H  Booth"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11194","name":"James H  Booth et al"},"object":{"type":"mine","id":"1518026","name":"No. 5"},"validFrom":"1984-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518026|C11194|1984-04-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15428","name":"Richard  Goff"},"object":{"type":"mine","id":"1518026","name":"No. 5"},"validFrom":"1996-04-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518026|C15428|1996-04-26|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23467","name":"Bethel Energy Corp"},"object":{"type":"mine","id":"1518026","name":"No. 5"},"validFrom":"1998-02-01","validTo":"2002-12-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518026|P23467|1998-02-01|2002-12-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15428","name":"Richard  Goff"},"object":{"type":"operator","id":"P23467","name":"Bethel Energy Corp"},"validFrom":"1998-02-01","validTo":"2002-12-29","current":false,"derived":true,"evidenceMineId":"1518026","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518026|P23467|1998-02-01|C15428|1996-04-26|95571"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050887","name":"Argus Energy, LLC"},"object":{"type":"mine","id":"1518026","name":"No. 5"},"validFrom":"2002-12-30","validTo":"2002-12-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518026|0050887|2002-12-30|2002-12-30"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11194","name":"James H  Booth et al"},"object":{"type":"mine","id":"1518026","name":"No. 5"},"validFrom":"2002-12-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518026|C11194|2002-12-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11194","name":"James H  Booth et al"},"object":{"type":"operator","id":"0050887","name":"Argus Energy, LLC"},"validFrom":"2002-12-30","validTo":"2002-12-30","current":false,"derived":true,"evidenceMineId":"1518026","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518026|0050887|2002-12-30|C11194|2002-12-30|83987"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P15627","name":"Coalburg Enterprises, Inc."},"object":{"type":"mine","id":"1518026","name":"No. 5"},"validFrom":"2002-12-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518026|P15627|2002-12-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11194","name":"James H  Booth et al"},"object":{"type":"operator","id":"P15627","name":"Coalburg Enterprises, Inc."},"validFrom":"2002-12-31","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518026","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518026|P15627|2002-12-31|C11194|1984-04-01|83862"}}],"coverage":{"historyRecords":3,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":13,"firstDate":"2000-01-11","lastDate":"2004-09-11","metrics":{"daysLost":735,"injuries":13,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"134608","DOCUMENT_NO":"220042640095","ACCIDENT_DT":"09/11/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"27","NARRATIVE":"EE was walking around roof bolter when a rock fell in between roof bolts hitting him in the head. Rock was about 1 inch thick 1 foot wide.","sourceDate":"2004-09-11"},{"SOURCE_ROW_NUMBER":"203518","DOCUMENT_NO":"220041530032","ACCIDENT_DT":"05/21/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"43","NARRATIVE":"EE WAS DRILLING HOLE IN ROOF FOR ROOF BOLT WHEN DRILL STEEL BENT, HITTING HIS LEFT HAND AND BREAKING HIS LEFT WRIST.","sourceDate":"2004-05-21"},{"SOURCE_ROW_NUMBER":"91608","DOCUMENT_NO":"220033630072","ACCIDENT_DT":"12/16/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"FELL JUST ABOVE BOLTS FROM SPAD 1103 TO 1429 (3 FULL INTERSECTIONS IN #5 ENTRY. BUTTED OFF #5 ENTRY INBY SPAD #1429 LEAVING A BARRIER BLOCK 60\" THICK. INSTALLED SUPPLEMENT ROOF SUPPORT IN #4 A ND #6 ENTRY BY ADDING ROPE BOLTS AND CRIBBING 4 RIGHT BREAK THROUGHS AND CRIBBING 6 LEFT BREAK THROUGHS IN AFFECT AREA.","sourceDate":"2003-12-16"},{"SOURCE_ROW_NUMBER":"177759","DOCUMENT_NO":"220033210036","ACCIDENT_DT":"11/11/2003","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","NARRATIVE":"EE WAS DRILLING A CONNECTOR ON A CABLE AND IT GOT FOULED UP. DRILL BIT KICKED AROUND & HIT RING FINGER AND LITTLE FINGER.","sourceDate":"2003-11-11"},{"SOURCE_ROW_NUMBER":"229427","DOCUMENT_NO":"220032790065","ACCIDENT_DT":"09/20/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"195","NARRATIVE":"EE WAS WALKING AND CUTTING A BELT CLAMP HIS FOOT SLIPED AND HURT HIS HIP.","sourceDate":"2003-09-20"},{"SOURCE_ROW_NUMBER":"14338","DOCUMENT_NO":"220031540059","ACCIDENT_DT":"05/27/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"276","NARRATIVE":"THE EE HAD FINISHED BOLTING AND BACKED BOLTER UP& WAS CHANGING BITS OUT WHEN A PIECE OF DRAW ROCK FELL 2\" THICK, 6'LONG IN #2 ENTRY ON SECTION DRAW ROCK HIT HIM ON BACK OF NECK & LEFT SHOULDER","sourceDate":"2003-05-27"},{"SOURCE_ROW_NUMBER":"233701","DOCUMENT_NO":"220001710121","ACCIDENT_DT":"06/12/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"CHIEF ELECT AND MINE FOREMAN WAS CALLED OUT AT 6:00 PM TO CHECK POWER PROBLEM. FOUND ROOF FALL TRACK ENTRY #2 BELTHEAD, FALL MEASURED 18' WIDE,BY 60' LENGTH BY 5' THICK. THIS AREA WAS BOLTED WITH 48\" RESIN BOLTS.","sourceDate":"2000-06-12"},{"SOURCE_ROW_NUMBER":"199169","DOCUMENT_NO":"220001540029","ACCIDENT_DT":"05/24/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"40","NARRATIVE":"EE WAS CLOSING GARAGE DOOR TO SUPPLY ROOM, WHEN ROLLERS AND PINS BROKE OUT OF A SECTION OF THE DOOR, LETTING THAT SECTION OF THE DOOR COLLAPSE AND HIT EE IN THE BACK OF HIS HEAD AND NECK. Y","sourceDate":"2000-05-24"},{"SOURCE_ROW_NUMBER":"10026","DOCUMENT_NO":"220001540034","ACCIDENT_DT":"05/24/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"28","NARRATIVE":"EE WAS DRILLING TOP, DRILL STEEL WRENCH CAME OFF HEAD OF BOLT, MASHED LEFT HAND CAUSING LACERATION. WILL NEED SUTURES.","sourceDate":"2000-05-24"},{"SOURCE_ROW_NUMBER":"263827","DOCUMENT_NO":"220000560054","ACCIDENT_DT":"02/21/2000","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between running or meshing objects","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","NARRATIVE":"EE WAS GREASING UNIVERSAL DRIVELINE ON LOCOMOTIVE, PUT LEFT HAND ON U-JOINT TO ROTATE DRIVELINE AROUND TO GREASE FITTING. (EE DIDN'T HAVE PARK BRAKE SET.) LOCOMOTIVE STARTED FREEWHEELING, GLOV E CAUGHT IN U-JOINT WHILE LOCOMOTIVE WAS FREEWHEELING, CAUSING REMOVAL TO TIP OF LEFT RING RINGER.","sourceDate":"2000-02-21"},{"SOURCE_ROW_NUMBER":"173441","DOCUMENT_NO":"220000590137","ACCIDENT_DT":"02/21/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"50","NARRATIVE":"EE WAS PUTTING HYDRAULIC PUMP ON 488 S & S SCOOP, FOOT SLIPPED ON OILY SURFACE TWISTED KNEE.","sourceDate":"2000-02-21"},{"SOURCE_ROW_NUMBER":"203517","DOCUMENT_NO":"220000590018","ACCIDENT_DT":"02/18/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"3","DAYS_LOST":"41","NARRATIVE":"EE WAS OPERATING REMOTE CONTROL CONTINOUS MINER CUTTING FACE OF #9 ENTRY PIECE OF DRAW SLATE FELL FROM BETWEEN RIB AND ROOF BOLT STRIKING EE ON HEAD, RT SIDE OF FACE, AND RT ARM CAUSING LACERA TIONS.","sourceDate":"2000-02-18"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-05-11","lastDate":"2012-05-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":85,"firstDate":"2000-01-13","lastDate":"2004-08-30","metrics":{"ss":19,"delinquent":85,"recentRows":0,"paidPenalty":5071,"proposedPenalty":7701,"currentAssessment":7453},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1009446","VIOLATION_NO":"7412591","ISSUE_DT":"08/30/2004","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-30"},{"SOURCE_ROW_NUMBER":"1009445","VIOLATION_NO":"7412590","ISSUE_DT":"08/29/2004","CFR_STANDARD_CD":"75.333(b)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-29"},{"SOURCE_ROW_NUMBER":"1009444","VIOLATION_NO":"7412586","ISSUE_DT":"08/23/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"1009443","VIOLATION_NO":"7412585","ISSUE_DT":"08/23/2004","CFR_STANDARD_CD":"75.364(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"1009442","VIOLATION_NO":"7412584","ISSUE_DT":"08/23/2004","CFR_STANDARD_CD":"75.310(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"1007340","VIOLATION_NO":"7408157","ISSUE_DT":"06/17/2004","CFR_STANDARD_CD":"75.1200","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"1007339","VIOLATION_NO":"7408156","ISSUE_DT":"06/17/2004","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"1007338","VIOLATION_NO":"7408155","ISSUE_DT":"06/17/2004","CFR_STANDARD_CD":"75.383(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"1007337","VIOLATION_NO":"7408154","ISSUE_DT":"06/17/2004","CFR_STANDARD_CD":"75.1702","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"1007336","VIOLATION_NO":"7408135","ISSUE_DT":"04/20/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-20"},{"SOURCE_ROW_NUMBER":"1007335","VIOLATION_NO":"7408134","ISSUE_DT":"04/20/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-20"},{"SOURCE_ROW_NUMBER":"1007334","VIOLATION_NO":"7408133","ISSUE_DT":"04/20/2004","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":25,"firstDate":"2000-10-11","lastDate":"2004-12-16","metrics":{"appeals":0,"decisions":25,"recentRows":0,"decisionPenalty":3375,"originalPenalty":3891},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"182891","VIOLATION_NO":"7403929","DOCKET_NO":"KENT 2004-199","DECISION_DT":"12/16/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"154.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-16"},{"SOURCE_ROW_NUMBER":"182890","VIOLATION_NO":"7403144","DOCKET_NO":"KENT 2004-199","DECISION_DT":"12/16/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"114.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-16"},{"SOURCE_ROW_NUMBER":"185644","VIOLATION_NO":"7412586","DOCKET_NO":"KENT 2005-17","DECISION_DT":"12/15/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-15"},{"SOURCE_ROW_NUMBER":"185383","VIOLATION_NO":"7412590","DOCKET_NO":"KENT 2005-17","DECISION_DT":"12/15/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-15"},{"SOURCE_ROW_NUMBER":"185263","VIOLATION_NO":"7412585","DOCKET_NO":"KENT 2005-17","DECISION_DT":"12/15/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-15"},{"SOURCE_ROW_NUMBER":"185262","VIOLATION_NO":"7412584","DOCKET_NO":"KENT 2005-17","DECISION_DT":"12/15/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-15"},{"SOURCE_ROW_NUMBER":"2958","VIOLATION_NO":"7412591","DOCKET_NO":"KENT 2005-17","DECISION_DT":"12/15/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"165.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-15"},{"SOURCE_ROW_NUMBER":"184663","VIOLATION_NO":"7408134","DOCKET_NO":"KENT 2004-262","DECISION_DT":"09/27/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-09-27"},{"SOURCE_ROW_NUMBER":"184508","VIOLATION_NO":"7408129","DOCKET_NO":"KENT 2004-262","DECISION_DT":"09/27/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-09-27"},{"SOURCE_ROW_NUMBER":"184486","VIOLATION_NO":"7408135","DOCKET_NO":"KENT 2004-262","DECISION_DT":"09/27/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-09-27"},{"SOURCE_ROW_NUMBER":"184485","VIOLATION_NO":"7408133","DOCKET_NO":"KENT 2004-262","DECISION_DT":"09/27/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"154.00","DECISION_PENALTY_AMT":"154.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-09-27"},{"SOURCE_ROW_NUMBER":"184401","VIOLATION_NO":"7408126","DOCKET_NO":"KENT 2004-262","DECISION_DT":"09/27/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-09-27"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":132,"firstDate":"2000-01-31","lastDate":"2004-08-31","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":11,"validSamples":121,"maxConcentration":3.252,"concentrationTotal":91.887},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"593931","CASS_NUM":"57508517","SMP_TAKEN_DT":"8/31/2004","CONC":".796","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"490020","CASS_NUM":"57508482","SMP_TAKEN_DT":"8/31/2004","CONC":".566","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"334624","CASS_NUM":"57508510","SMP_TAKEN_DT":"8/31/2004","CONC":".266","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"309198","CASS_NUM":"57508509","SMP_TAKEN_DT":"8/31/2004","CONC":".206","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"55770","CASS_NUM":"57508553","SMP_TAKEN_DT":"8/31/2004","CONC":"1.038","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"1566133","CASS_NUM":"50745890","SMP_TAKEN_DT":"8/6/2004","CONC":".582","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-06"},{"SOURCE_ROW_NUMBER":"973911","CASS_NUM":"50745852","SMP_TAKEN_DT":"8/6/2004","CONC":".258","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-06"},{"SOURCE_ROW_NUMBER":"1653380","CASS_NUM":"50745871","SMP_TAKEN_DT":"8/5/2004","CONC":"2.66","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-05"},{"SOURCE_ROW_NUMBER":"386617","CASS_NUM":"50745877","SMP_TAKEN_DT":"8/5/2004","CONC":".163","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-05"},{"SOURCE_ROW_NUMBER":"115719","CASS_NUM":"50745832","SMP_TAKEN_DT":"8/5/2004","CONC":".385","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-08-05"},{"SOURCE_ROW_NUMBER":"1580297","CASS_NUM":"50745826","SMP_TAKEN_DT":"7/13/2004","CONC":".263","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-07-13"},{"SOURCE_ROW_NUMBER":"1566439","CASS_NUM":"57563329","SMP_TAKEN_DT":"6/22/2004","CONC":".171","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-22"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":5,"firstDate":"2000-03-30","lastDate":"2003-07-17","metrics":{"linkedIssuances":5},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":169,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":23,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1998-02-01","lastDate":"2002-12-31","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":45,"firstDate":"2000-01-03","lastDate":"2004-08-31","metrics":{"inspectors":53,"recentRows":0,"onSiteHours":730,"inspectionHours":1262.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"643213","EVENT_NO":"4183850","INSPECTION_BEGIN_DT":"08/31/2004","INSPECTION_END_DT":"09/30/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"55298","EVENT_NO":"4184466","INSPECTION_BEGIN_DT":"07/07/2004","INSPECTION_END_DT":"07/07/2004","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-07-07"},{"SOURCE_ROW_NUMBER":"947931","EVENT_NO":"4184463","INSPECTION_BEGIN_DT":"07/01/2004","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"36","SUM_TOTAL_ON_SITE_HOURS":"19","sourceDate":"2004-07-01"},{"SOURCE_ROW_NUMBER":"183210","EVENT_NO":"4183833","INSPECTION_BEGIN_DT":"06/17/2004","INSPECTION_END_DT":"07/01/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"1092501","EVENT_NO":"4183832","INSPECTION_BEGIN_DT":"06/09/2004","INSPECTION_END_DT":"06/25/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"757227","EVENT_NO":"4183826","INSPECTION_BEGIN_DT":"04/30/2004","INSPECTION_END_DT":"06/01/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-04-30"},{"SOURCE_ROW_NUMBER":"1020522","EVENT_NO":"4183823","INSPECTION_BEGIN_DT":"04/01/2004","INSPECTION_END_DT":"06/25/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"78","SUM_TOTAL_ON_SITE_HOURS":"51.5","sourceDate":"2004-04-01"},{"SOURCE_ROW_NUMBER":"790940","EVENT_NO":"4183818","INSPECTION_BEGIN_DT":"02/19/2004","INSPECTION_END_DT":"03/05/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-02-19"},{"SOURCE_ROW_NUMBER":"514530","EVENT_NO":"4183816","INSPECTION_BEGIN_DT":"01/21/2004","INSPECTION_END_DT":"01/26/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"18","sourceDate":"2004-01-21"},{"SOURCE_ROW_NUMBER":"929343","EVENT_NO":"4183813","INSPECTION_BEGIN_DT":"01/05/2004","INSPECTION_END_DT":"03/31/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"198.5","SUM_TOTAL_ON_SITE_HOURS":"122","sourceDate":"2004-01-05"},{"SOURCE_ROW_NUMBER":"379757","EVENT_NO":"4183770","INSPECTION_BEGIN_DT":"12/22/2003","INSPECTION_END_DT":"12/22/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2003-12-22"},{"SOURCE_ROW_NUMBER":"372123","EVENT_NO":"4183769","INSPECTION_BEGIN_DT":"11/12/2003","INSPECTION_END_DT":"11/14/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2003-11-12"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":22,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q4":{"hours":0,"employees":0,"production":0},"2004-Q3":{"hours":8760,"employees":21,"production":68155},"2004-Q2":{"hours":15181,"employees":24,"production":55614},"2004-Q1":{"hours":18779,"employees":29,"production":94912},"2003-Q4":{"hours":21360,"employees":31,"production":115740},"2003-Q3":{"hours":17636,"employees":32,"production":110034},"2003-Q2":{"hours":22241,"employees":30,"production":99572},"2001-Q4":{"hours":0,"employees":0,"production":0},"2001-Q3":{"hours":0,"employees":0,"production":0},"2000-Q2":{"hours":20,"employees":2,"production":0},"2000-Q1":{"hours":24468,"employees":42,"production":81349}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":24488,"employees":22,"production":81349},"2003":{"hours":61237,"employees":31,"production":325346},"2004":{"hours":42720,"employees":25,"production":218681}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":22,"firstDate":"2000-02-29","lastDate":"2004-06-22","metrics":{"recentRows":0,"doseOver100":5,"actDoseTotal":1673,"pelDoseTotal":1236},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"66882","EVENT_NO":"4183832","SURVEY_DATE":"06/22/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"63","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2004-06-22"},{"SOURCE_ROW_NUMBER":"66881","EVENT_NO":"4183832","SURVEY_DATE":"06/22/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"78","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2004-06-22"},{"SOURCE_ROW_NUMBER":"66880","EVENT_NO":"4183832","SURVEY_DATE":"06/22/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"72","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2004-06-22"},{"SOURCE_ROW_NUMBER":"66879","EVENT_NO":"4183832","SURVEY_DATE":"06/22/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"83","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2004-06-22"},{"SOURCE_ROW_NUMBER":"66878","EVENT_NO":"4183832","SURVEY_DATE":"06/22/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"118","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2004-06-22"},{"SOURCE_ROW_NUMBER":"66877","EVENT_NO":"4183816","SURVEY_DATE":"01/22/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"83","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2004-01-22"},{"SOURCE_ROW_NUMBER":"66876","EVENT_NO":"4183816","SURVEY_DATE":"01/22/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2004-01-22"},{"SOURCE_ROW_NUMBER":"66875","EVENT_NO":"4183816","SURVEY_DATE":"01/22/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"96","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2004-01-22"},{"SOURCE_ROW_NUMBER":"66874","EVENT_NO":"4183816","SURVEY_DATE":"01/22/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","ACT_DOSE_85":"85","PEL_DOSE_90":"68","SURVEY_TYPE":"I","sourceDate":"2004-01-22"},{"SOURCE_ROW_NUMBER":"66873","EVENT_NO":"4183816","SURVEY_DATE":"01/22/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"07","MANUFACTURER_CD":"058","ACT_DOSE_85":"125","PEL_DOSE_90":"105","SURVEY_TYPE":"I","sourceDate":"2004-01-22"},{"SOURCE_ROW_NUMBER":"66872","EVENT_NO":"4175032","SURVEY_DATE":"05/05/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"26","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2003-05-05"},{"SOURCE_ROW_NUMBER":"66871","EVENT_NO":"4175032","SURVEY_DATE":"05/05/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"76","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2003-05-05"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":20,"firstDate":"2000-02-07","lastDate":"2004-06-22","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":10.1,"validSamples":19,"quartzPctTotal":109.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"151692","CASSETTE_NO":"57563333","SAMPLE_DT":"06/22/2004","QUARTZ_PCT":"03.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-22"},{"SOURCE_ROW_NUMBER":"22466","CASSETTE_NO":"57563302","SAMPLE_DT":"06/22/2004","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-22"},{"SOURCE_ROW_NUMBER":"152067","CASSETTE_NO":"57554108","SAMPLE_DT":"05/10/2004","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-10"},{"SOURCE_ROW_NUMBER":"60953","CASSETTE_NO":"57554103","SAMPLE_DT":"05/10/2004","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-10"},{"SOURCE_ROW_NUMBER":"122297","CASSETTE_NO":"57519804","SAMPLE_DT":"02/23/2004","QUARTZ_PCT":"05.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"82168","CASSETTE_NO":"57519795","SAMPLE_DT":"02/23/2004","QUARTZ_PCT":"08.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"53827","CASSETTE_NO":"50726152","SAMPLE_DT":"01/13/2004","QUARTZ_PCT":"04.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-13"},{"SOURCE_ROW_NUMBER":"89979","CASSETTE_NO":"57519552","SAMPLE_DT":"12/22/2003","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-22"},{"SOURCE_ROW_NUMBER":"34078","CASSETTE_NO":"57519597","SAMPLE_DT":"12/22/2003","QUARTZ_PCT":"06.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-22"},{"SOURCE_ROW_NUMBER":"127033","CASSETTE_NO":"50718603","SAMPLE_DT":"12/21/2003","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2003-12-21"},{"SOURCE_ROW_NUMBER":"137841","CASSETTE_NO":"50717306","SAMPLE_DT":"12/02/2003","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-02"},{"SOURCE_ROW_NUMBER":"127365","CASSETTE_NO":"50718674","SAMPLE_DT":"12/02/2003","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-02"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":94,"firstDate":"2000-01-13","lastDate":"2004-08-30","metrics":{"ss":19,"amountDue":7453,"contested":23,"amountPaid":5071,"recentRows":0,"section104d":0,"unterminated":2,"proposedPenalty":7701},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"942836","VIOLATION_NO":"7412591","VIOLATION_ISSUE_DT":"08/30/2004","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/31/2004","PROPOSED_PENALTY":"177","AMOUNT_DUE":"165","AMOUNT_PAID":"165","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2005-17","sourceDate":"2004-08-30"},{"SOURCE_ROW_NUMBER":"942835","VIOLATION_NO":"7412590","VIOLATION_ISSUE_DT":"08/29/2004","SIG_SUB":"N","PART_SECTION":"75.333(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/31/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2005-17","sourceDate":"2004-08-29"},{"SOURCE_ROW_NUMBER":"942834","VIOLATION_NO":"7412586","VIOLATION_ISSUE_DT":"08/23/2004","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2005-17","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"942833","VIOLATION_NO":"7412585","VIOLATION_ISSUE_DT":"08/23/2004","SIG_SUB":"N","PART_SECTION":"75.364(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2005-17","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"942832","VIOLATION_NO":"7412584","VIOLATION_ISSUE_DT":"08/23/2004","SIG_SUB":"N","PART_SECTION":"75.310(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2005-17","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"942813","VIOLATION_NO":"7408157","VIOLATION_ISSUE_DT":"06/17/2004","SIG_SUB":"N","PART_SECTION":"75.1200","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/22/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"942812","VIOLATION_NO":"7408156","VIOLATION_ISSUE_DT":"06/17/2004","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/22/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"942811","VIOLATION_NO":"7408155","VIOLATION_ISSUE_DT":"06/17/2004","SIG_SUB":"N","PART_SECTION":"75.383(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/22/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"942810","VIOLATION_NO":"7408154","VIOLATION_ISSUE_DT":"06/17/2004","SIG_SUB":"N","PART_SECTION":"75.1702","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/22/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"942809","VIOLATION_NO":"7408135","VIOLATION_ISSUE_DT":"04/20/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/22/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2004-262","sourceDate":"2004-04-20"},{"SOURCE_ROW_NUMBER":"942808","VIOLATION_NO":"7408134","VIOLATION_ISSUE_DT":"04/20/2004","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/22/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2004-262","sourceDate":"2004-04-20"},{"SOURCE_ROW_NUMBER":"942807","VIOLATION_NO":"7408133","VIOLATION_ISSUE_DT":"04/20/2004","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/27/2004","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"154","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2004-262","sourceDate":"2004-04-20"}]}],"safety":{"href":"/api/v1/mines/1518026/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518026/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Mine map.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1200","part":"75","subchapter":"O","subpart":"M","id":"75.1200","citation":"30 CFR 75.1200","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Smoking; prohibition.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1702","part":"75","subchapter":"O","subpart":"R","id":"75.1702","citation":"30 CFR 75.1702","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518026","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}