{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1517990","name":"#5 Punch Mine","status":"Abandoned and Sealed","status_date":"2002-01-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Knott","nearest_town":"Sassafras","operator_id":"P23236","operator_name":"Gemco Energies Inc","controller_id":"C15304","controller_name":"Jimmy W  Tackett","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.266389,"longitude":-83.013333},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":802},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517990","name":"#5 Punch Mine"},"operator":{"type":"operator","id":"P23236","name":"Gemco Energies Inc"},"controller":{"type":"controller","id":"C15304","name":"Jimmy W  Tackett"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15304","name":"Jimmy W  Tackett et al"},"object":{"type":"mine","id":"1517990","name":"#5 Punch Mine"},"validFrom":"1995-09-27","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517990|C15304|1995-09-27|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23236","name":"Gemco Energies Inc"},"object":{"type":"mine","id":"1517990","name":"#5 Punch Mine"},"validFrom":"1997-10-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517990|P23236|1997-10-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15304","name":"Jimmy W  Tackett et al"},"object":{"type":"operator","id":"P23236","name":"Gemco Energies Inc"},"validFrom":"1997-10-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517990","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517990|P23236|1997-10-01|C15304|1995-09-27|95225"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":20,"firstDate":"2000-02-29","lastDate":"2001-09-14","metrics":{"daysLost":211,"injuries":11,"fatalities":0,"recentRows":0,"restrictedDays":5,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"225026","DOCUMENT_NO":"220012670008","ACCIDENT_DT":"09/14/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"17","NARRATIVE":"EE WAS HITTING BELT STRUCTURE WITH A HAMMER AND A PIECE OF METAL HIT HIM IN THE RIGHT EYE.","sourceDate":"2001-09-14"},{"SOURCE_ROW_NUMBER":"95867","DOCUMENT_NO":"220012670116","ACCIDENT_DT":"09/11/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"SOFT SHELL TOP WITH RIDE AT 8'. THE AREA WAS CRIBBED & METAL SUPPORT. THE FALL WAS 8' X 40' X 18' IN THE MAIN RETURN. IT BLOCKED THE RETURN FOR TRAVEL. MINING HAS BEEN STOPPED DUE TO THIS FALL & OTHER AREAS IN THE RETURN 3,000' DEEP.","sourceDate":"2001-09-11"},{"SOURCE_ROW_NUMBER":"113088","DOCUMENT_NO":"220012120026","ACCIDENT_DT":"07/23/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"TOP WAS CHANGING INTO SANDSTONE. TRANSITION AREA HAD A HORSEBACK AND SOFT SHELL. THE ENTRY WAS STOPPED AND CRIBBED OFF. IT FELL ONE WEEK LATER.","sourceDate":"2001-07-23"},{"SOURCE_ROW_NUMBER":"199167","DOCUMENT_NO":"220012010080","ACCIDENT_DT":"07/18/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE BURNT HANDS WHILE USING TORCH.","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"160578","DOCUMENT_NO":"220011910031","ACCIDENT_DT":"06/28/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"6' X 20' X 30' - THE ROOF HAS A RIDER SEAM AT 6'-8' IN THE AREA. WATER IN THE ROOF AND THE RIDERCONTRIBUTED TO FALL. #3 MAIN, #4 ENTRY, 2200' UNDERGROUND.","sourceDate":"2001-06-28"},{"SOURCE_ROW_NUMBER":"61542","DOCUMENT_NO":"220011580033","ACCIDENT_DT":"06/05/2001","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"A PIECE OF DRAW ROCK FELL FROM THE BOLTER CANOPY AND HIT EE ON THE LEFT HAND. THE LEFT THUMB HAD TO HAVE STITCHES.","sourceDate":"2001-06-05"},{"SOURCE_ROW_NUMBER":"121670","DOCUMENT_NO":"220011490151","ACCIDENT_DT":"05/25/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"33","NARRATIVE":"EE WAS PULLING MINING CABLE.","sourceDate":"2001-05-25"},{"SOURCE_ROW_NUMBER":"263824","DOCUMENT_NO":"220011430012","ACCIDENT_DT":"05/11/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE FALL WAS 1800 UNDERGROUND ON THE MAIN INTAKE. IT WAS IN A TRANSITION AREA WHEN WE BEGAN HOLDING THE MAIN ROOF THAT HAS PREVIOUS BEEN TAKEN. THE BRATTICE LINE WAS REROUTED TO EXTABLISH THE PRIMARY ESCAPEWAY.","sourceDate":"2001-05-11"},{"SOURCE_ROW_NUMBER":"61541","DOCUMENT_NO":"220011380017","ACCIDENT_DT":"04/30/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"EE WAS HANGING MINER CABLE AND PULLED A MUSCLE.","sourceDate":"2001-04-30"},{"SOURCE_ROW_NUMBER":"18578","DOCUMENT_NO":"220011280030","ACCIDENT_DT":"04/27/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE AREA OF ROOF BECAME VERY WET WITH THE RIDER AT 6'. 7800' UNDERGROUND OFF #6 MAIN RETURN IN #7 HEADING IN 6 LEFT MAIN. VENTILATION WAS AFFECTED.","sourceDate":"2001-04-27"},{"SOURCE_ROW_NUMBER":"14334","DOCUMENT_NO":"220011280031","ACCIDENT_DT":"04/27/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"8000 UNDERGROUND, #1 ENTRY, #6 MAIN SOFT TOP SURROUNDING HORSEBACK.","sourceDate":"2001-04-27"},{"SOURCE_ROW_NUMBER":"31534","DOCUMENT_NO":"220011280029","ACCIDENT_DT":"04/26/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE WAS WALKING ON HEAD OF MACHINE HIS RATCHET SLIPPED AND HE HIT HIS ELBOW ON THE CONTINUOUS MINER.","sourceDate":"2001-04-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-01-16","lastDate":"2002-01-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":194,"firstDate":"2000-01-19","lastDate":"2001-09-05","metrics":{"ss":49,"delinquent":194,"recentRows":0,"paidPenalty":27312,"proposedPenalty":27312,"currentAssessment":27312},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1126928","VIOLATION_NO":"7513250","ISSUE_DT":"09/05/2001","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-05"},{"SOURCE_ROW_NUMBER":"1126927","VIOLATION_NO":"7513249","ISSUE_DT":"09/05/2001","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-05"},{"SOURCE_ROW_NUMBER":"1126926","VIOLATION_NO":"7513248","ISSUE_DT":"09/04/2001","CFR_STANDARD_CD":"75.1103-4(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-04"},{"SOURCE_ROW_NUMBER":"1126925","VIOLATION_NO":"7513247","ISSUE_DT":"09/04/2001","CFR_STANDARD_CD":"75.204(c)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"399.00","CURRENT_ASSESSMENT_AMT":"399.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-04"},{"SOURCE_ROW_NUMBER":"1126924","VIOLATION_NO":"7513246","ISSUE_DT":"09/04/2001","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-04"},{"SOURCE_ROW_NUMBER":"1126922","VIOLATION_NO":"7477493","ISSUE_DT":"08/29/2001","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-29"},{"SOURCE_ROW_NUMBER":"1126921","VIOLATION_NO":"7477488","ISSUE_DT":"08/23/2001","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"557.00","CURRENT_ASSESSMENT_AMT":"557.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"1126920","VIOLATION_NO":"7477487","ISSUE_DT":"08/23/2001","CFR_STANDARD_CD":"75.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"1126919","VIOLATION_NO":"7477486","ISSUE_DT":"08/23/2001","CFR_STANDARD_CD":"75.1100-2(e)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"1126918","VIOLATION_NO":"7477485","ISSUE_DT":"08/23/2001","CFR_STANDARD_CD":"75.1100-2(e)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"1126917","VIOLATION_NO":"7477484","ISSUE_DT":"08/23/2001","CFR_STANDARD_CD":"75.1714-2(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"399.00","CURRENT_ASSESSMENT_AMT":"399.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"1126916","VIOLATION_NO":"7477483","ISSUE_DT":"08/23/2001","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-23"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":186,"firstDate":"2000-02-04","lastDate":"2001-09-07","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":16,"validSamples":170,"maxConcentration":3.924,"concentrationTotal":143.244},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"773486","CASS_NUM":"50603755","SMP_TAKEN_DT":"9/7/2001","CONC":"1.075","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-09-07"},{"SOURCE_ROW_NUMBER":"553831","CASS_NUM":"50603680","SMP_TAKEN_DT":"9/6/2001","CONC":"1.865","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"1639728","CASS_NUM":"50597989","SMP_TAKEN_DT":"8/24/2001","CONC":".534","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-24"},{"SOURCE_ROW_NUMBER":"1649398","CASS_NUM":"50597991","SMP_TAKEN_DT":"8/23/2001","CONC":"3.01","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"481644","CASS_NUM":"50597990","SMP_TAKEN_DT":"8/22/2001","CONC":".84","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-22"},{"SOURCE_ROW_NUMBER":"1591753","CASS_NUM":"57340216","SMP_TAKEN_DT":"8/21/2001","CONC":".496","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-21"},{"SOURCE_ROW_NUMBER":"1342732","CASS_NUM":"57340215","SMP_TAKEN_DT":"8/21/2001","CONC":".223","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-21"},{"SOURCE_ROW_NUMBER":"1090391","CASS_NUM":"57340185","SMP_TAKEN_DT":"8/21/2001","CONC":".216","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-21"},{"SOURCE_ROW_NUMBER":"1025164","CASS_NUM":"50598049","SMP_TAKEN_DT":"8/21/2001","CONC":".429","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-21"},{"SOURCE_ROW_NUMBER":"742168","CASS_NUM":"57340202","SMP_TAKEN_DT":"8/21/2001","CONC":".247","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-21"},{"SOURCE_ROW_NUMBER":"437699","CASS_NUM":"57340227","SMP_TAKEN_DT":"8/21/2001","CONC":".216","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-21"},{"SOURCE_ROW_NUMBER":"253343","CASS_NUM":"57340240","SMP_TAKEN_DT":"8/21/2001","CONC":".501","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-21"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":86,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":21,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1997-10-01","lastDate":"1997-10-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":42,"firstDate":"2000-01-19","lastDate":"2002-01-15","metrics":{"inspectors":51,"recentRows":0,"onSiteHours":667.75,"inspectionHours":1060.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"327690","EVENT_NO":"4222133","INSPECTION_BEGIN_DT":"01/15/2002","INSPECTION_END_DT":"01/15/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"574933","EVENT_NO":"4225062","INSPECTION_BEGIN_DT":"12/12/2001","INSPECTION_END_DT":"12/12/2001","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2001-12-12"},{"SOURCE_ROW_NUMBER":"813398","EVENT_NO":"4222117","INSPECTION_BEGIN_DT":"10/04/2001","INSPECTION_END_DT":"10/04/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2001-10-04"},{"SOURCE_ROW_NUMBER":"432345","EVENT_NO":"4213507","INSPECTION_BEGIN_DT":"09/12/2001","INSPECTION_END_DT":"09/17/2001","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"12.25","sourceDate":"2001-09-12"},{"SOURCE_ROW_NUMBER":"114250","EVENT_NO":"4225033","INSPECTION_BEGIN_DT":"08/24/2001","INSPECTION_END_DT":"08/24/2001","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2001-08-24"},{"SOURCE_ROW_NUMBER":"946205","EVENT_NO":"4213932","INSPECTION_BEGIN_DT":"07/23/2001","INSPECTION_END_DT":"07/23/2001","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2001-07-23"},{"SOURCE_ROW_NUMBER":"375200","EVENT_NO":"4229510","INSPECTION_BEGIN_DT":"07/02/2001","INSPECTION_END_DT":"09/07/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"118.5","SUM_TOTAL_ON_SITE_HOURS":"69.75","sourceDate":"2001-07-02"},{"SOURCE_ROW_NUMBER":"516733","EVENT_NO":"4225944","INSPECTION_BEGIN_DT":"06/27/2001","INSPECTION_END_DT":"07/02/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"136625","EVENT_NO":"4225946","INSPECTION_BEGIN_DT":"06/27/2001","INSPECTION_END_DT":"08/29/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"40","SUM_TOTAL_ON_SITE_HOURS":"24","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"38209","EVENT_NO":"4225945","INSPECTION_BEGIN_DT":"06/27/2001","INSPECTION_END_DT":"07/02/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"274953","EVENT_NO":"4225002","INSPECTION_BEGIN_DT":"06/05/2001","INSPECTION_END_DT":"06/06/2001","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2001-06-05"},{"SOURCE_ROW_NUMBER":"831040","EVENT_NO":"4217664","INSPECTION_BEGIN_DT":"05/24/2001","INSPECTION_END_DT":"05/24/2001","ACTIVITY_CODE":"CEA","ACTIVITY":"ROOF CONTROL TECHNICAL INVESTIGTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2001-05-24"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001-Q3":{"hours":13771,"employees":27,"production":33567},"2001-Q2":{"hours":14209,"employees":27,"production":47220},"2001-Q1":{"hours":17065,"employees":30,"production":54629},"2000-Q4":{"hours":16813,"employees":29,"production":69668},"2000-Q3":{"hours":15532,"employees":30,"production":61038},"2000-Q2":{"hours":18481,"employees":29,"production":55932},"2000-Q1":{"hours":17376,"employees":31,"production":53618}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":68202,"employees":32,"production":240256},"2001":{"hours":45045,"employees":29,"production":135416}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":11,"firstDate":"2000-05-15","lastDate":"2001-06-28","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":652,"pelDoseTotal":453},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"66160","EVENT_NO":"4225945","SURVEY_DATE":"06/28/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"55","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2001-06-28"},{"SOURCE_ROW_NUMBER":"66159","EVENT_NO":"4225945","SURVEY_DATE":"06/28/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"62","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2001-06-28"},{"SOURCE_ROW_NUMBER":"66158","EVENT_NO":"4225945","SURVEY_DATE":"06/28/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"62","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2001-06-28"},{"SOURCE_ROW_NUMBER":"66157","EVENT_NO":"4225945","SURVEY_DATE":"06/28/2001","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"30","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2001-06-28"},{"SOURCE_ROW_NUMBER":"66156","EVENT_NO":"4225945","SURVEY_DATE":"06/28/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"38","MANUFACTURER_CD":"033","ACT_DOSE_85":"42","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2001-06-28"},{"SOURCE_ROW_NUMBER":"66155","EVENT_NO":"4225944","SURVEY_DATE":"06/28/2001","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"47","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2001-06-28"},{"SOURCE_ROW_NUMBER":"66165","EVENT_NO":"4233373","SURVEY_DATE":"05/15/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"033","ACT_DOSE_85":"116","PEL_DOSE_90":"109","SURVEY_TYPE":"I","sourceDate":"2000-05-15"},{"SOURCE_ROW_NUMBER":"66164","EVENT_NO":"4233373","SURVEY_DATE":"05/15/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"48","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2000-05-15"},{"SOURCE_ROW_NUMBER":"66163","EVENT_NO":"4233373","SURVEY_DATE":"05/15/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"110","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2000-05-15"},{"SOURCE_ROW_NUMBER":"66162","EVENT_NO":"4233373","SURVEY_DATE":"05/15/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"51","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2000-05-15"},{"SOURCE_ROW_NUMBER":"66161","EVENT_NO":"4233373","SURVEY_DATE":"05/15/2000","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"29","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2000-05-15"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":16,"firstDate":"2000-02-07","lastDate":"2001-08-02","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":21.1,"validSamples":16,"quartzPctTotal":140.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"61281","CASSETTE_NO":"57329193","SAMPLE_DT":"08/02/2001","QUARTZ_PCT":"15.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-08-02"},{"SOURCE_ROW_NUMBER":"62117","CASSETTE_NO":"57315196","SAMPLE_DT":"06/28/2001","QUARTZ_PCT":"16.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-28"},{"SOURCE_ROW_NUMBER":"103041","CASSETTE_NO":"50578510","SAMPLE_DT":"05/08/2001","QUARTZ_PCT":"14.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-05-08"},{"SOURCE_ROW_NUMBER":"153658","CASSETTE_NO":"50578476","SAMPLE_DT":"05/03/2001","QUARTZ_PCT":"21.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-05-03"},{"SOURCE_ROW_NUMBER":"30603","CASSETTE_NO":"57315580","SAMPLE_DT":"04/19/2001","QUARTZ_PCT":"20.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-19"},{"SOURCE_ROW_NUMBER":"19755","CASSETTE_NO":"57315625","SAMPLE_DT":"04/19/2001","QUARTZ_PCT":"18.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-19"},{"SOURCE_ROW_NUMBER":"143161","CASSETTE_NO":"57315485","SAMPLE_DT":"02/28/2001","QUARTZ_PCT":"00.7","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-02-28"},{"SOURCE_ROW_NUMBER":"87754","CASSETTE_NO":"57309998","SAMPLE_DT":"12/04/2000","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-12-04"},{"SOURCE_ROW_NUMBER":"36477","CASSETTE_NO":"57310075","SAMPLE_DT":"12/04/2000","QUARTZ_PCT":"00.3","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-12-04"},{"SOURCE_ROW_NUMBER":"139071","CASSETTE_NO":"57300222","SAMPLE_DT":"09/12/2000","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-09-12"},{"SOURCE_ROW_NUMBER":"130595","CASSETTE_NO":"57300169","SAMPLE_DT":"09/12/2000","QUARTZ_PCT":"07.9","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-09-12"},{"SOURCE_ROW_NUMBER":"78507","CASSETTE_NO":"57300256","SAMPLE_DT":"09/12/2000","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-09-12"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":201,"firstDate":"2000-01-19","lastDate":"2001-09-12","metrics":{"ss":49,"amountDue":27312,"contested":0,"amountPaid":27312,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":27312},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"937296","VIOLATION_NO":"7478002","VIOLATION_ISSUE_DT":"09/12/2001","SECTION_OF_ACT":"103(k)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"09/17/2001","CONTESTED_IND":"N","sourceDate":"2001-09-12"},{"SOURCE_ROW_NUMBER":"937267","VIOLATION_NO":"7513250","VIOLATION_ISSUE_DT":"09/05/2001","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/05/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-05"},{"SOURCE_ROW_NUMBER":"937266","VIOLATION_NO":"7513249","VIOLATION_ISSUE_DT":"09/05/2001","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/05/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-05"},{"SOURCE_ROW_NUMBER":"937265","VIOLATION_NO":"7513248","VIOLATION_ISSUE_DT":"09/04/2001","SIG_SUB":"N","PART_SECTION":"75.1103-4(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/05/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-04"},{"SOURCE_ROW_NUMBER":"937264","VIOLATION_NO":"7513247","VIOLATION_ISSUE_DT":"09/04/2001","SIG_SUB":"Y","PART_SECTION":"75.204(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/05/2001","PROPOSED_PENALTY":"399","AMOUNT_DUE":"399","AMOUNT_PAID":"399","CONTESTED_IND":"N","sourceDate":"2001-09-04"},{"SOURCE_ROW_NUMBER":"937263","VIOLATION_NO":"7513246","VIOLATION_ISSUE_DT":"09/04/2001","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/04/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-04"},{"SOURCE_ROW_NUMBER":"937261","VIOLATION_NO":"7477493","VIOLATION_ISSUE_DT":"08/29/2001","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2001","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"340","CONTESTED_IND":"N","sourceDate":"2001-08-29"},{"SOURCE_ROW_NUMBER":"937260","VIOLATION_NO":"7477492","VIOLATION_ISSUE_DT":"08/29/2001","PART_SECTION":"75.1403-10(i)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"09/04/2001","CONTESTED_IND":"N","sourceDate":"2001-08-29"},{"SOURCE_ROW_NUMBER":"937259","VIOLATION_NO":"7477488","VIOLATION_ISSUE_DT":"08/23/2001","SIG_SUB":"Y","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/23/2001","PROPOSED_PENALTY":"557","AMOUNT_DUE":"557","AMOUNT_PAID":"557","CONTESTED_IND":"N","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"937258","VIOLATION_NO":"7477487","VIOLATION_ISSUE_DT":"08/23/2001","SIG_SUB":"N","PART_SECTION":"75.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/23/2001","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"340","CONTESTED_IND":"N","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"937257","VIOLATION_NO":"7477486","VIOLATION_ISSUE_DT":"08/23/2001","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/23/2001","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"340","CONTESTED_IND":"N","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"937256","VIOLATION_NO":"7477485","VIOLATION_ISSUE_DT":"08/23/2001","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/23/2001","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"340","CONTESTED_IND":"N","sourceDate":"2001-08-23"}]}],"safety":{"href":"/api/v1/mines/1517990/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517990/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Roof bolting.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.204","part":"75","subchapter":"O","subpart":"C","id":"75.204","citation":"30 CFR 75.204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-10","heading":"Criteria—Haulage; general.","id":"75.1403-10","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-10","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) A permissible trip light or other approved device such as reflectors, approved by the Coal Mine Safety District Manager(s), should be used on the rear of trips pulled, on the front of trips pushed and on trips lowered in slopes. However, trip lights or other approved devices need not be used on cars being shifted to and from loading machines, on cars being handled at loading heads, during gathering operations at working faces, when trailing locomotives are used, or on trips pulled by animals.\n\n(b) Cars on main haulage roads should not be pushed, except where necessary to push cars from side tracks located near the working section to the producing entries and rooms, where necessary to clear switches and sidetracks, and on the approach to cages, slopes, and surface inclines.\n\n(c) Warning lights or reflective signs or tapes should be installed along haulage roads at locations of abrupt or sudden changes in the overhead clearance.\n\n(d) No person, other than the motorman and brakeman, should ride on a locomotive unless authorized by the mine foreman, and then only when safe riding facilities are provided. No person should ride on any loaded car or on the bumper of any car. However, the brakeman may ride on the rear bumper of the last car of a slow moving trip pulled by a locomotive.\n\n(e) Positive-acting stopblocks or derails should be used where necessary to protect persons from danger of runaway haulage equipment.\n\n(f) An audible warning should be given by the operator of all self-propelled equipment including off-track equipment, where persons may be endangered by the movement of the equipment.\n\n(g) Locomotives and personnel carriers should not approach to within 300 feet of preceding haulage equipment, except trailing locomotives that are an integral part of the trip.\n\n(h) A total of at least 36 inches of unobstructed side clearance (both sides combined) should be provided for all rubber-tired haulage equipment where such equipment is used.\n\n(i) Off-track haulage roadways should be maintained as free as practicable from bottom irregularities, debris, and wet or muddy conditions that affect the control of the equipment.\n\n(j) Operators of self-propelled equipment should face in the direction of travel.\n\n(k) Mechanical steering and control devices should be maintained so as to provide positive control at all times.\n\n(l) All self-propelled rubber-tired haulage equipment should be equipped with well maintained brakes, lights, and a warning device.\n\n(m) On and after March 30, 1971, all tram control switches on rubber-tired equipment should be designed to provide automatic return to the stop or off position when released.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.701","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","id":"75.701","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-H/section-75.701","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"H","subpartHeading":"Subpart H—Grounding","text":"[Statutory Provisions]\n\nMetallic frames, casings, and other enclosures of electric equipment that can become “alive” through failure of insulation or by contact with energized parts shall be grounded by methods approved by an authorized representative of the Secretary.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517990","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}