{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1517976","name":"Mine No 1","status":"Abandoned and Sealed","status_date":"2003-03-25","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Pikeville","operator_id":"P24662","operator_name":"Bluegrass Mining Co., Inc","controller_id":"C16063","controller_name":"Doug A  Reed","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.551388,"longitude":-82.480833},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":331},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517976","name":"Mine No 1"},"operator":{"type":"operator","id":"P24662","name":"Bluegrass Mining Co., Inc"},"controller":{"type":"controller","id":"C16063","name":"Doug A  Reed"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07431","name":"Troy  Wright"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"1979-06-12","validTo":"1999-06-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|C07431|1979-06-12|1999-06-03"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"1988-09-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|C13562|1988-09-28|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00829","name":"Mack  Stiltner et al"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"1988-11-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|C00829|1988-11-08|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11000","name":"James L  Bevins"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"1989-04-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|C11000|1989-04-10|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19831","name":"Mc Coy Elkhorn Coal Corp"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"1997-09-01","validTo":"1998-09-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P19831|1997-09-01|1998-09-22"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P19831","name":"Mc Coy Elkhorn Coal Corp"},"validFrom":"1997-09-01","validTo":"1998-09-22","current":false,"derived":true,"evidenceMineId":"1517976","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P19831|1997-09-01|C13562|1988-09-28|90331"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22088","name":"J J Coal Company Inc"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"1998-09-23","validTo":"1999-04-28","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P22088|1998-09-23|1999-04-28"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00829","name":"Mack  Stiltner et al"},"object":{"type":"operator","id":"P22088","name":"J J Coal Company Inc"},"validFrom":"1998-09-23","validTo":"1999-04-28","current":false,"derived":true,"evidenceMineId":"1517976","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P22088|1998-09-23|C00829|1988-11-08|50329"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P09453","name":"Wright Coal Company Inc"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"1999-04-29","validTo":"1999-06-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P09453|1999-04-29|1999-06-03"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07431","name":"Troy  Wright"},"object":{"type":"operator","id":"P09453","name":"Wright Coal Company Inc"},"validFrom":"1999-04-29","validTo":"1999-06-03","current":false,"derived":true,"evidenceMineId":"1517976","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P09453|1999-04-29|C07431|1979-06-12|74577"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P20276","name":"Fools Gold Energy Corp"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"1999-06-04","validTo":"2001-05-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P20276|1999-06-04|2001-05-17"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11000","name":"James L  Bevins"},"object":{"type":"operator","id":"P20276","name":"Fools Gold Energy Corp"},"validFrom":"1999-06-04","validTo":"2001-05-17","current":false,"derived":true,"evidenceMineId":"1517976","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P20276|1999-06-04|C11000|1989-04-10|83352"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24662","name":"Bluegrass Mining Co., Inc"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"2001-05-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P24662|2001-05-18|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16063","name":"Doug A  Reed"},"object":{"type":"mine","id":"1517976","name":"Mine No 1"},"validFrom":"2001-05-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|C16063|2001-05-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16063","name":"Doug A  Reed"},"object":{"type":"operator","id":"P24662","name":"Bluegrass Mining Co., Inc"},"validFrom":"2001-05-18","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517976","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517976|P24662|2001-05-18|C16063|2001-05-18|98225"}}],"coverage":{"historyRecords":5,"edgeCount":15,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2001-12-17","lastDate":"2001-12-17","metrics":{"daysLost":16,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"139020","DOCUMENT_NO":"220020150035","ACCIDENT_DT":"12/17/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"16","NARRATIVE":"EE SLIPPED, CAUGHT HIMSELF WITH LEFT HAND CAUSING PAIN IN LEFT WRIST.","sourceDate":"2001-12-17"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2003-03-25","lastDate":"2003-03-25","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":55,"firstDate":"2000-01-18","lastDate":"2002-10-10","metrics":{"ss":18,"delinquent":55,"recentRows":0,"paidPenalty":3525.7,"proposedPenalty":3721,"currentAssessment":3721},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"945419","VIOLATION_NO":"7392985","ISSUE_DT":"10/10/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-10-10"},{"SOURCE_ROW_NUMBER":"945418","VIOLATION_NO":"7392984","ISSUE_DT":"10/10/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"113.00","CURRENT_ASSESSMENT_AMT":"113.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-10-10"},{"SOURCE_ROW_NUMBER":"944892","VIOLATION_NO":"7387297","ISSUE_DT":"08/29/2002","CFR_STANDARD_CD":"75.1100-2(e)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"944891","VIOLATION_NO":"7387296","ISSUE_DT":"08/29/2002","CFR_STANDARD_CD":"77.504","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"944890","VIOLATION_NO":"7387295","ISSUE_DT":"08/29/2002","CFR_STANDARD_CD":"77.509(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"76.00","CURRENT_ASSESSMENT_AMT":"76.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"944889","VIOLATION_NO":"7387291","ISSUE_DT":"08/15/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"113.00","CURRENT_ASSESSMENT_AMT":"113.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-15"},{"SOURCE_ROW_NUMBER":"944888","VIOLATION_NO":"7387290","ISSUE_DT":"08/15/2002","CFR_STANDARD_CD":"77.1607(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-15"},{"SOURCE_ROW_NUMBER":"944887","VIOLATION_NO":"7387282","ISSUE_DT":"08/05/2002","CFR_STANDARD_CD":"70.207(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-05"},{"SOURCE_ROW_NUMBER":"944825","VIOLATION_NO":"7387263","ISSUE_DT":"06/18/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-18"},{"SOURCE_ROW_NUMBER":"944824","VIOLATION_NO":"7387262","ISSUE_DT":"06/18/2002","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"66.00","CURRENT_ASSESSMENT_AMT":"66.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-18"},{"SOURCE_ROW_NUMBER":"944823","VIOLATION_NO":"7387260","ISSUE_DT":"06/17/2002","CFR_STANDARD_CD":"75.1100-2(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-17"},{"SOURCE_ROW_NUMBER":"944822","VIOLATION_NO":"7387254","ISSUE_DT":"06/10/2002","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-10"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":108,"firstDate":"2000-01-05","lastDate":"2002-09-11","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":35,"validSamples":73,"maxConcentration":15.525,"concentrationTotal":90.232},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"392091","CASS_NUM":"50645870","SMP_TAKEN_DT":"9/11/2002","CONC":".865","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-11"},{"SOURCE_ROW_NUMBER":"462217","CASS_NUM":"50652235","SMP_TAKEN_DT":"8/22/2002","CONC":".014","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-22"},{"SOURCE_ROW_NUMBER":"1337531","CASS_NUM":"57422145","SMP_TAKEN_DT":"8/13/2002","CONC":".87","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-13"},{"SOURCE_ROW_NUMBER":"923219","CASS_NUM":"57422125","SMP_TAKEN_DT":"8/13/2002","CONC":".276","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-13"},{"SOURCE_ROW_NUMBER":"857887","CASS_NUM":"57422156","SMP_TAKEN_DT":"8/13/2002","CONC":".687","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-13"},{"SOURCE_ROW_NUMBER":"111160","CASS_NUM":"57422143","SMP_TAKEN_DT":"8/13/2002","CONC":"1.232","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID WORK POSITION","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-13"},{"SOURCE_ROW_NUMBER":"80996","CASS_NUM":"57422158","SMP_TAKEN_DT":"8/13/2002","CONC":"1.387","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-13"},{"SOURCE_ROW_NUMBER":"3413","CASS_NUM":"57422144","SMP_TAKEN_DT":"8/13/2002","CONC":".092","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-13"},{"SOURCE_ROW_NUMBER":"1170325","CASS_NUM":"57422128","SMP_TAKEN_DT":"8/12/2002","CONC":".778","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"962436","CASS_NUM":"57422153","SMP_TAKEN_DT":"8/12/2002","CONC":".257","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"737610","CASS_NUM":"57422115","SMP_TAKEN_DT":"8/12/2002","CONC":".499","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"649367","CASS_NUM":"57422114","SMP_TAKEN_DT":"8/12/2002","CONC":".264","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-12"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":23,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1997-09-01","lastDate":"2001-05-18","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":31,"firstDate":"2000-01-18","lastDate":"2003-03-25","metrics":{"inspectors":32,"recentRows":0,"onSiteHours":413.75,"inspectionHours":587.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"531684","EVENT_NO":"4163594","INSPECTION_BEGIN_DT":"03/25/2003","INSPECTION_END_DT":"03/25/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2003-03-25"},{"SOURCE_ROW_NUMBER":"1111831","EVENT_NO":"4163585","INSPECTION_BEGIN_DT":"10/08/2002","INSPECTION_END_DT":"10/21/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2002-10-08"},{"SOURCE_ROW_NUMBER":"1076497","EVENT_NO":"4164473","INSPECTION_BEGIN_DT":"08/12/2002","INSPECTION_END_DT":"08/29/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"19","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"1023798","EVENT_NO":"4163426","INSPECTION_BEGIN_DT":"07/30/2002","INSPECTION_END_DT":"09/24/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"52","SUM_TOTAL_ON_SITE_HOURS":"34","sourceDate":"2002-07-30"},{"SOURCE_ROW_NUMBER":"595663","EVENT_NO":"4164467","INSPECTION_BEGIN_DT":"07/30/2002","INSPECTION_END_DT":"08/14/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2002-07-30"},{"SOURCE_ROW_NUMBER":"714935","EVENT_NO":"4163418","INSPECTION_BEGIN_DT":"05/16/2002","INSPECTION_END_DT":"06/28/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"52.5","SUM_TOTAL_ON_SITE_HOURS":"35","sourceDate":"2002-05-16"},{"SOURCE_ROW_NUMBER":"1030459","EVENT_NO":"4164132","INSPECTION_BEGIN_DT":"04/23/2002","INSPECTION_END_DT":"04/30/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2002-04-23"},{"SOURCE_ROW_NUMBER":"892592","EVENT_NO":"4163104","INSPECTION_BEGIN_DT":"04/15/2002","INSPECTION_END_DT":"04/29/2002","ACTIVITY_CODE":"CEC","ACTIVITY":"VENTILATION TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2002-04-15"},{"SOURCE_ROW_NUMBER":"626523","EVENT_NO":"6187953","INSPECTION_BEGIN_DT":"03/11/2002","INSPECTION_END_DT":"03/29/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"60.5","SUM_TOTAL_ON_SITE_HOURS":"46","sourceDate":"2002-03-11"},{"SOURCE_ROW_NUMBER":"1074913","EVENT_NO":"4163746","INSPECTION_BEGIN_DT":"03/08/2002","INSPECTION_END_DT":"03/08/2002","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2002-03-08"},{"SOURCE_ROW_NUMBER":"67680","EVENT_NO":"4164113","INSPECTION_BEGIN_DT":"03/04/2002","INSPECTION_END_DT":"04/30/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2002-03-04"},{"SOURCE_ROW_NUMBER":"401814","EVENT_NO":"4163699","INSPECTION_BEGIN_DT":"01/24/2002","INSPECTION_END_DT":"02/01/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2002-01-24"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":19,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003-Q1":{"hours":0,"employees":0,"production":0},"2002-Q4":{"hours":1128,"employees":19,"production":8506},"2002-Q3":{"hours":6874,"employees":14,"production":30637},"2002-Q2":{"hours":8370,"employees":15,"production":32916},"2002-Q1":{"hours":9214,"employees":16,"production":44608},"2001-Q4":{"hours":6882,"employees":13,"production":34421},"2001-Q3":{"hours":5694,"employees":14,"production":28377},"2001-Q2":{"hours":0,"employees":0,"production":0},"2000-Q3":{"hours":0,"employees":0,"production":0},"2000-Q1":{"hours":10620,"employees":23,"production":36430}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":10620,"employees":23,"production":36430},"2001":{"hours":12576,"employees":14,"production":62798},"2002":{"hours":25586,"employees":16,"production":116667}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":11,"firstDate":"2000-02-24","lastDate":"2001-11-28","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":708,"pelDoseTotal":512},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"65858","EVENT_NO":"4163671","SURVEY_DATE":"11/28/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"66","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"65857","EVENT_NO":"4163671","SURVEY_DATE":"11/28/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"106","PEL_DOSE_90":"88","SURVEY_TYPE":"I","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"65856","EVENT_NO":"4163671","SURVEY_DATE":"11/28/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"106","PEL_DOSE_90":"88","SURVEY_TYPE":"I","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"65855","EVENT_NO":"4163671","SURVEY_DATE":"11/28/2001","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"75","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"65854","EVENT_NO":"4163671","SURVEY_DATE":"11/28/2001","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"47","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"65853","EVENT_NO":"4163671","SURVEY_DATE":"11/28/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"55","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"65863","EVENT_NO":"6141904","SURVEY_DATE":"02/24/2000","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2000-02-24"},{"SOURCE_ROW_NUMBER":"65862","EVENT_NO":"6141904","SURVEY_DATE":"02/24/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"81","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2000-02-24"},{"SOURCE_ROW_NUMBER":"65861","EVENT_NO":"6141904","SURVEY_DATE":"02/24/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"69","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2000-02-24"},{"SOURCE_ROW_NUMBER":"65860","EVENT_NO":"6141904","SURVEY_DATE":"02/24/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"53","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2000-02-24"},{"SOURCE_ROW_NUMBER":"65859","EVENT_NO":"6141904","SURVEY_DATE":"02/24/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"44","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2000-02-24"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":10,"firstDate":"2000-01-12","lastDate":"2002-09-06","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":23.9,"validSamples":10,"quartzPctTotal":66.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"135209","CASSETTE_NO":"50670767","SAMPLE_DT":"09/06/2002","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-09-06"},{"SOURCE_ROW_NUMBER":"113353","CASSETTE_NO":"50645908","SAMPLE_DT":"08/16/2002","QUARTZ_PCT":"02.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-08-16"},{"SOURCE_ROW_NUMBER":"95984","CASSETTE_NO":"57422075","SAMPLE_DT":"07/30/2002","QUARTZ_PCT":"23.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-07-30"},{"SOURCE_ROW_NUMBER":"141240","CASSETTE_NO":"50652263","SAMPLE_DT":"05/21/2002","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"117018","CASSETTE_NO":"50649110","SAMPLE_DT":"05/07/2002","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-07"},{"SOURCE_ROW_NUMBER":"101222","CASSETTE_NO":"57422861","SAMPLE_DT":"04/23/2002","QUARTZ_PCT":"11.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-04-23"},{"SOURCE_ROW_NUMBER":"40268","CASSETTE_NO":"57400478","SAMPLE_DT":"03/12/2002","QUARTZ_PCT":"04.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-12"},{"SOURCE_ROW_NUMBER":"135686","CASSETTE_NO":"57324772","SAMPLE_DT":"11/28/2001","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"80199","CASSETTE_NO":"50473077","SAMPLE_DT":"01/13/2000","QUARTZ_PCT":"04.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-01-13"},{"SOURCE_ROW_NUMBER":"135118","CASSETTE_NO":"50473117","SAMPLE_DT":"01/12/2000","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-01-12"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":56,"firstDate":"2000-01-18","lastDate":"2002-10-10","metrics":{"ss":18,"amountDue":3721,"contested":0,"amountPaid":3525.7,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":3721},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"935174","VIOLATION_NO":"7392985","VIOLATION_ISSUE_DT":"10/10/2002","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/17/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-10-10"},{"SOURCE_ROW_NUMBER":"935173","VIOLATION_NO":"7392984","VIOLATION_ISSUE_DT":"10/10/2002","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/17/2002","PROPOSED_PENALTY":"113","AMOUNT_DUE":"113","AMOUNT_PAID":"113","CONTESTED_IND":"N","sourceDate":"2002-10-10"},{"SOURCE_ROW_NUMBER":"935172","VIOLATION_NO":"7387297","VIOLATION_ISSUE_DT":"08/29/2002","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/29/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"935171","VIOLATION_NO":"7387296","VIOLATION_ISSUE_DT":"08/29/2002","SIG_SUB":"N","PART_SECTION":"77.504","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"935170","VIOLATION_NO":"7387295","VIOLATION_ISSUE_DT":"08/29/2002","SIG_SUB":"Y","PART_SECTION":"77.509(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/29/2002","PROPOSED_PENALTY":"76","AMOUNT_DUE":"76","AMOUNT_PAID":"76","CONTESTED_IND":"N","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"935169","VIOLATION_NO":"7387291","VIOLATION_ISSUE_DT":"08/15/2002","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2002","PROPOSED_PENALTY":"113","AMOUNT_DUE":"113","AMOUNT_PAID":"113","CONTESTED_IND":"N","sourceDate":"2002-08-15"},{"SOURCE_ROW_NUMBER":"935168","VIOLATION_NO":"7387290","VIOLATION_ISSUE_DT":"08/15/2002","SIG_SUB":"N","PART_SECTION":"77.1607(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-08-15"},{"SOURCE_ROW_NUMBER":"935167","VIOLATION_NO":"7387282","VIOLATION_ISSUE_DT":"08/05/2002","SIG_SUB":"N","PART_SECTION":"70.207(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/05/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-08-05"},{"SOURCE_ROW_NUMBER":"935158","VIOLATION_NO":"7387263","VIOLATION_ISSUE_DT":"06/18/2002","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/25/2002","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2002-06-18"},{"SOURCE_ROW_NUMBER":"935157","VIOLATION_NO":"7387262","VIOLATION_ISSUE_DT":"06/18/2002","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/25/2002","PROPOSED_PENALTY":"66","AMOUNT_DUE":"66","AMOUNT_PAID":"66","CONTESTED_IND":"N","sourceDate":"2002-06-18"},{"SOURCE_ROW_NUMBER":"935156","VIOLATION_NO":"7387261","VIOLATION_ISSUE_DT":"06/17/2002","PART_SECTION":"75.1403-5(g)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"1","TERMINATION_DT":"06/18/2002","CONTESTED_IND":"N","sourceDate":"2002-06-17"},{"SOURCE_ROW_NUMBER":"935155","VIOLATION_NO":"7387260","VIOLATION_ISSUE_DT":"06/17/2002","SIG_SUB":"N","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/25/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-06-17"}]}],"safety":{"href":"/api/v1/mines/1517976/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517976/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":2},{"chapter":"I","heading":"Electrical connections or splices; suitability.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.504","part":"77","subchapter":"O","subpart":"F","id":"77.504","citation":"30 CFR 77.504","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Transformers; installation and guarding.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.509","part":"77","subchapter":"O","subpart":"F","id":"77.509","citation":"30 CFR 77.509","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1607","heading":"Loading and haulage equipment; operation.","id":"77.1607","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1607","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Vehicles shall follow at a safe distance; passing shall be limited to areas of adequate clearance and visibility.\n\n(b) Mobile equipment operators shall have full control of the equipment while it is in motion.\n\n(c) Equipment operating speeds shall be prudent and consistent with conditions of roadway, grades, clearance, visibility, traffic, and the type of equipment used.\n\n(d) Cabs of mobile equipment shall be kept free of extraneous materials.\n\n(e) Operators shall sit facing the direction of travel while operating equipment with dual controls.\n\n(f) When an equipment operator is present, men shall notify him before getting on or off equipment.\n\n(g) Equipment operators shall be certain, by signal or other means, that all persons are clear before starting or moving equipment.\n\n(h) Where possible, aerial tramways shall not be started until the tramway operator has ascertained that everyone is in the clear.\n\n(i) Dust control measures shall be taken where dust significantly reduces visibility of equipment operators.\n\n(j) Dippers, buckets, loading booms, or heavy suspended loads shall not be swung over the cabs of haulage vehicles until the drivers are out of the cabs and in safe locations, unless the trucks are designed specifically to protect the drivers from falling material.\n\n(k) Men shall not work or pass under the buckets or booms of loaders in operation.\n\n(l) Tires shall be deflated before repairs on them are started and adequate means shall be provided to prevent wheel locking rims from creating a hazard during tire inflation.\n\n(m) Electrically powered mobile equipment shall not be left unattended unless the master switch is in the off position, all operating controls are in the neutral position, and the brakes are set or other equivalent precautions are taken against rolling.\n\n(n) Mobile equipment shall not be left unattended unless the brakes are set. The wheels shall be turned into a bank or berm, or shall be blocked, when such equipment is parked on a grade.\n\n(o) Lights, flares, or other warning devices shall be posted when parked equipment creates a hazard to vehicular traffic.\n\n(p) Dippers, buckets, scraper blades, and similar movable parts shall be secured or lowered to the ground when not in use.\n\n(q) Shovel trailing cables shall not be moved with the shovel dipper unless cable slings or sleds are used.\n\n(r) Equipment which is to be hauled shall be loaded and protected so as to prevent sliding or spillage.\n\n(s) When moving between work areas, the equipment shall be secured in the travel position.\n\n(t) Any load extending more than 4 feet beyond the rear of the vehicle body should be marked clearly with a red flag by day and a red light at night.\n\n(u) Tow bars shall be used to tow heavy equipment and a safety chain shall be used in conjunction with each tow bar.\n\n(v) Railroad cars shall be kept under control at all times by the car dropper. Cars shall be dropped at a safe rate and in a manner that will insure that the car dropper maintains a safe position while working and traveling around the cars.\n\n(w) Railroad cars shall not be coupled or uncoupled manually from the inside of curves unless the railroad and cars are so designed to eliminate any hazard from coupling or uncoupling cars from inside of curves.\n\n(x) Persons shall wear safety belts when dropping railroad cars.\n\n(y) Railcars shall not be left on sidetracks unless ample clearance is provided for traffic on adjacent tracks.\n\n(z) Parked railcars, unless held effectively by brakes, shall be blocked securely.\n\n(aa) Railroad cars and all trucks shall be trimmed properly when they have been loaded higher than the confines of their cargo space.\n\n(bb) When the entire length of a conveyor is visible from the starting switch, the operator shall visually check to make certain that all persons are in the clear before starting the conveyor. When the entire length of the conveyor is not visible from the starting switch, a positive audible or visible warning system shall be installed and operated to warn persons that the conveyor will be started.\n\n(cc) Unguarded conveyors with walkways shall be equipped with emergency stop devices or cords along their full length.\n\n(dd) Adequate backstops or brakes shall be installed on inclined-conveyor drive units to prevent conveyors from running in reverse if a hazard to personnel would be caused.\n\n(ee) Aerial tram conveyor buckets shall not be overloaded, and feed shall be regulated to prevent spillage.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-5","heading":"Criteria—Belt conveyors.","id":"75.1403-5","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-5","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) Positive-acting stop controls should be installed along all belt conveyors used to transport men, and such controls should be readily accessible and maintained so that the belt can be stopped or started at any location.\n\n(b) Belt conveyors used for regularly scheduled mantrips should be stopped while men are loading or unloading.\n\n(c) All belt conveyors used for the transportation of persons should have a minimum vertical clearance of 18 inches from the nearest overhead projection when measured from the edge of the belt and there should be at least 36 inches of side clearance where men board or leave such belt conveyors.\n\n(d) When men are being transported on regularly scheduled mantrips on belt conveyors the belt speed should not exceed 300 feet per minute when the vertical clearance is less than 24 inches, and should not exceed 350 feet per minute when the vertical clearance is 24 inches or more.\n\n(e) Adequate illumination including colored lights or reflective signs should be installed at all loading and unloading stations. Such colored lights and reflective signs should be so located as to be observable to all persons riding the belt conveyor.\n\n(f) After supplies have been transported on belt conveyors such belts should be examined for unsafe conditions prior to the transportation of men on regularly scheduled mantrips, and belt conveyors should be clear before men are transported.\n\n(g) A clear travelway at least 24 inches wide should be provided on both sides of all belt conveyors installed after March 30, 1970. Where roof supports are installed within 24 inches of a belt conveyor, a clear travelway at least 24 inches wide should be provided on the side of such support farthest from the conveyor.\n\n(h) On belt conveyors that do not transport men, stop and start controls should be installed at intervals not to exceed 1,000 feet. Such controls should be properly installed and positioned so as to be readily accessible.\n\n(i) Telephone or other suitable communications should be provided at points where men or supplies are regularly loaded on or unloaded from the belt conveyors.\n\n(j) Persons should not cross moving belt conveyors, except where suitable crossing facilities are provided.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517976","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}