{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1517962","name":"# 2","status":"Abandoned and Sealed","status_date":"2010-08-18","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Martin","nearest_town":"Prestonsburg","operator_id":"P23696","operator_name":"Starlight Coal Inc","controller_id":"C15567","controller_name":"Dennis R  Yonts","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.634166,"longitude":-82.662222},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1653},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517962","name":"# 2"},"operator":{"type":"operator","id":"P23696","name":"Starlight Coal Inc"},"controller":{"type":"controller","id":"C15567","name":"Dennis R  Yonts"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15567","name":"Dennis R  Yonts"},"object":{"type":"mine","id":"1517962","name":"# 2"},"validFrom":"1997-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517962|C15567|1997-04-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23756","name":"Resolve Mining Corp"},"object":{"type":"mine","id":"1517962","name":"# 2"},"validFrom":"1997-07-01","validTo":"1998-03-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517962|P23756|1997-07-01|1998-03-13"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C06191","name":"Benjamin  Hampton"},"object":{"type":"mine","id":"1517962","name":"# 2"},"validFrom":"1997-07-01","validTo":"1998-03-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517962|C06191|1997-07-01|1998-03-13"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06191","name":"Benjamin  Hampton"},"object":{"type":"operator","id":"P23756","name":"Resolve Mining Corp"},"validFrom":"1997-07-01","validTo":"1998-03-13","current":false,"derived":true,"evidenceMineId":"1517962","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517962|P23756|1997-07-01|C06191|1997-07-01|71125"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23696","name":"Starlight Coal Inc"},"object":{"type":"mine","id":"1517962","name":"# 2"},"validFrom":"1998-03-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517962|P23696|1998-03-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15567","name":"Dennis R  Yonts"},"object":{"type":"operator","id":"P23696","name":"Starlight Coal Inc"},"validFrom":"1998-03-14","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517962","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517962|P23696|1998-03-14|C15567|1997-04-01|96219"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":4,"firstDate":"2000-01-27","lastDate":"2004-05-17","metrics":{"daysLost":22,"injuries":2,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"229420","DOCUMENT_NO":"220041530123","ACCIDENT_DT":"05/17/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"While using a metal pry bar to move a conveyer belt roller, the ee got his left foot caught under the pry bar. This resulted in a bruised foot, no broken bones. This happened in the surface shop area.","sourceDate":"2004-05-17"},{"SOURCE_ROW_NUMBER":"57233","DOCUMENT_NO":"220023600010","ACCIDENT_DT":"12/11/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE ROOF STARTED TO SHOW SIGNS OF FAILURE. THE AREA WAS CRIB & TIMBERED & DANGERED OFF.","sourceDate":"2002-12-11"},{"SOURCE_ROW_NUMBER":"61540","DOCUMENT_NO":"220012190035","ACCIDENT_DT":"07/30/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE ROOF STARTED TO SHOW SIGNS OF FAILURE. THE AREA WAS THEN CRIBED OFF.","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"164860","DOCUMENT_NO":"220000380173","ACCIDENT_DT":"01/27/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"18","NARRATIVE":"TORE OR PULLED A MUSCLE IN LOWER LET LEG INSTALLING A TAIL ROLLER BEARING.","sourceDate":"2000-01-27"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2010-08-18","lastDate":"2010-08-18","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":358,"firstDate":"2000-01-13","lastDate":"2004-04-19","metrics":{"ss":158,"delinquent":358,"recentRows":0,"paidPenalty":1401,"proposedPenalty":65016,"currentAssessment":65016},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"977188","VIOLATION_NO":"7404285","ISSUE_DT":"04/19/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"305.00","CURRENT_ASSESSMENT_AMT":"305.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"977187","VIOLATION_NO":"7404284","ISSUE_DT":"04/19/2004","CFR_STANDARD_CD":"75.1100-2(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"977186","VIOLATION_NO":"7404283","ISSUE_DT":"04/19/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"191.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"977185","VIOLATION_NO":"7404282","ISSUE_DT":"04/19/2004","CFR_STANDARD_CD":"75.1106-3(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"977184","VIOLATION_NO":"7404281","ISSUE_DT":"04/19/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"977183","VIOLATION_NO":"7404280","ISSUE_DT":"04/19/2004","CFR_STANDARD_CD":"75.208","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"191.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"1006347","VIOLATION_NO":"7408068","ISSUE_DT":"03/22/2004","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"1006346","VIOLATION_NO":"7408067","ISSUE_DT":"03/22/2004","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"3000.00","CURRENT_ASSESSMENT_AMT":"3000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"1006345","VIOLATION_NO":"7408066","ISSUE_DT":"03/22/2004","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"191.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"1006344","VIOLATION_NO":"7408065","ISSUE_DT":"03/22/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"3000.00","CURRENT_ASSESSMENT_AMT":"3000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"1006343","VIOLATION_NO":"7408064","ISSUE_DT":"03/22/2004","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3400.00","CURRENT_ASSESSMENT_AMT":"3400.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"1006342","VIOLATION_NO":"7408063","ISSUE_DT":"03/22/2004","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-22"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":332,"firstDate":"2000-01-03","lastDate":"2004-04-21","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":19,"validSamples":313,"maxConcentration":5.057,"concentrationTotal":91.232},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1589296","CASS_NUM":"57563366","SMP_TAKEN_DT":"4/21/2004","CONC":".434","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"731750","CASS_NUM":"57563341","SMP_TAKEN_DT":"4/21/2004","CONC":".421","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"608548","CASS_NUM":"57563348","SMP_TAKEN_DT":"4/21/2004","CONC":".465","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"567364","CASS_NUM":"57563362","SMP_TAKEN_DT":"4/21/2004","CONC":".411","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"183991","CASS_NUM":"57563347","SMP_TAKEN_DT":"4/21/2004","CONC":".41","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"1650844","CASS_NUM":"50734605","SMP_TAKEN_DT":"4/5/2004","CONC":".051","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-05"},{"SOURCE_ROW_NUMBER":"974813","CASS_NUM":"50734637","SMP_TAKEN_DT":"3/8/2004","CONC":".031","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-08"},{"SOURCE_ROW_NUMBER":"204295","CASS_NUM":"50734638","SMP_TAKEN_DT":"3/5/2004","CONC":".168","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-05"},{"SOURCE_ROW_NUMBER":"1286160","CASS_NUM":"50734560","SMP_TAKEN_DT":"3/4/2004","CONC":".046","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"27065","CASS_NUM":"50734633","SMP_TAKEN_DT":"3/3/2004","CONC":".077","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-03"},{"SOURCE_ROW_NUMBER":"1475612","CASS_NUM":"57519874","SMP_TAKEN_DT":"3/2/2004","CONC":".116","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-02"},{"SOURCE_ROW_NUMBER":"1435533","CASS_NUM":"57519832","SMP_TAKEN_DT":"3/2/2004","CONC":".331","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-02"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":46,"firstDate":"2000-05-31","lastDate":"2004-03-11","metrics":{"linkedIssuances":46},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":324,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":49,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1997-07-01","lastDate":"1998-03-14","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":92,"firstDate":"2000-01-05","lastDate":"2004-09-07","metrics":{"inspectors":122,"recentRows":0,"onSiteHours":1426.5,"inspectionHours":2086.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"770104","EVENT_NO":"4175335","INSPECTION_BEGIN_DT":"09/07/2004","INSPECTION_END_DT":"09/07/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2004-09-07"},{"SOURCE_ROW_NUMBER":"620191","EVENT_NO":"4183991","INSPECTION_BEGIN_DT":"04/21/2004","INSPECTION_END_DT":"04/21/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"552612","EVENT_NO":"4175322","INSPECTION_BEGIN_DT":"04/19/2004","INSPECTION_END_DT":"06/21/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"54","SUM_TOTAL_ON_SITE_HOURS":"34","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"705676","EVENT_NO":"4183966","INSPECTION_BEGIN_DT":"02/26/2004","INSPECTION_END_DT":"03/03/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2004-02-26"},{"SOURCE_ROW_NUMBER":"1092293","EVENT_NO":"4183951","INSPECTION_BEGIN_DT":"02/02/2004","INSPECTION_END_DT":"02/10/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"8.75","sourceDate":"2004-02-02"},{"SOURCE_ROW_NUMBER":"653490","EVENT_NO":"4183952","INSPECTION_BEGIN_DT":"02/02/2004","INSPECTION_END_DT":"02/11/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"8.75","sourceDate":"2004-02-02"},{"SOURCE_ROW_NUMBER":"427738","EVENT_NO":"4183954","INSPECTION_BEGIN_DT":"02/02/2004","INSPECTION_END_DT":"03/03/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"4.75","sourceDate":"2004-02-02"},{"SOURCE_ROW_NUMBER":"81933","EVENT_NO":"4183953","INSPECTION_BEGIN_DT":"02/02/2004","INSPECTION_END_DT":"02/12/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"8.25","sourceDate":"2004-02-02"},{"SOURCE_ROW_NUMBER":"324993","EVENT_NO":"4183750","INSPECTION_BEGIN_DT":"01/28/2004","INSPECTION_END_DT":"01/28/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2004-01-28"},{"SOURCE_ROW_NUMBER":"442289","EVENT_NO":"4183276","INSPECTION_BEGIN_DT":"01/05/2004","INSPECTION_END_DT":"03/31/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"121.5","SUM_TOTAL_ON_SITE_HOURS":"80.5","sourceDate":"2004-01-05"},{"SOURCE_ROW_NUMBER":"167938","EVENT_NO":"4183734","INSPECTION_BEGIN_DT":"12/29/2003","INSPECTION_END_DT":"12/29/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2003-12-29"},{"SOURCE_ROW_NUMBER":"424718","EVENT_NO":"4183730","INSPECTION_BEGIN_DT":"11/25/2003","INSPECTION_END_DT":"11/26/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"8.75","sourceDate":"2003-11-25"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":37,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q3":{"hours":208,"employees":3,"production":0},"2004-Q2":{"hours":4040,"employees":10,"production":5151},"2004-Q1":{"hours":7014,"employees":18,"production":13100},"2003-Q4":{"hours":9535,"employees":20,"production":14473},"2003-Q3":{"hours":10542,"employees":22,"production":18934},"2003-Q2":{"hours":11589,"employees":22,"production":22500},"2003-Q1":{"hours":11791,"employees":24,"production":21554},"2002-Q4":{"hours":11695,"employees":22,"production":23619},"2002-Q3":{"hours":14000,"employees":24,"production":23432},"2002-Q2":{"hours":10250,"employees":24,"production":20166},"2002-Q1":{"hours":12565,"employees":24,"production":26468},"2001-Q4":{"hours":11128,"employees":22,"production":18401}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":48739,"employees":25,"production":108086},"2001":{"hours":39858,"employees":21,"production":86065},"2002":{"hours":48510,"employees":24,"production":93685},"2003":{"hours":43457,"employees":22,"production":77461},"2004":{"hours":11262,"employees":14,"production":18251}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2002-02-11","lastDate":"2004-03-02","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":781,"pelDoseTotal":555},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"65633","EVENT_NO":"4183966","SURVEY_DATE":"03/02/2004","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"47","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2004-03-02"},{"SOURCE_ROW_NUMBER":"65632","EVENT_NO":"4183966","SURVEY_DATE":"03/02/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"120","ACT_DOSE_85":"62","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2004-03-02"},{"SOURCE_ROW_NUMBER":"65631","EVENT_NO":"4183966","SURVEY_DATE":"03/02/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"114","ACT_DOSE_85":"64","PEL_DOSE_90":"61","SURVEY_TYPE":"I","sourceDate":"2004-03-02"},{"SOURCE_ROW_NUMBER":"65630","EVENT_NO":"4183966","SURVEY_DATE":"03/02/2004","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"49","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2004-03-02"},{"SOURCE_ROW_NUMBER":"65629","EVENT_NO":"4183966","SURVEY_DATE":"03/02/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"61","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2004-03-02"},{"SOURCE_ROW_NUMBER":"65628","EVENT_NO":"4175526","SURVEY_DATE":"01/24/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"114","ACT_DOSE_85":"37","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2003-01-24"},{"SOURCE_ROW_NUMBER":"65627","EVENT_NO":"4175526","SURVEY_DATE":"01/24/2003","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"28","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2003-01-24"},{"SOURCE_ROW_NUMBER":"65626","EVENT_NO":"4175526","SURVEY_DATE":"01/24/2003","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"42","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2003-01-24"},{"SOURCE_ROW_NUMBER":"65625","EVENT_NO":"4175526","SURVEY_DATE":"01/24/2003","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"18","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2003-01-24"},{"SOURCE_ROW_NUMBER":"65624","EVENT_NO":"4175526","SURVEY_DATE":"01/24/2003","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2003-01-24"},{"SOURCE_ROW_NUMBER":"65623","EVENT_NO":"4174138","SURVEY_DATE":"02/11/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"034","ACT_DOSE_85":"45","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2002-02-11"},{"SOURCE_ROW_NUMBER":"65622","EVENT_NO":"4174138","SURVEY_DATE":"02/11/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"034","ACT_DOSE_85":"74","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2002-02-11"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":17,"firstDate":"2000-01-20","lastDate":"2004-04-21","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":10.8,"validSamples":14,"quartzPctTotal":68.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"61736","CASSETTE_NO":"57563341","SAMPLE_DT":"04/21/2004","QUARTZ_PCT":"08.9","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"42947","CASSETTE_NO":"57563348","SAMPLE_DT":"04/21/2004","QUARTZ_PCT":"10.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"93736","CASSETTE_NO":"50710464","SAMPLE_DT":"01/14/2004","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2004-01-14"},{"SOURCE_ROW_NUMBER":"157976","CASSETTE_NO":"57519631","SAMPLE_DT":"12/29/2003","QUARTZ_PCT":"06.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-29"},{"SOURCE_ROW_NUMBER":"8348","CASSETTE_NO":"57519634","SAMPLE_DT":"12/29/2003","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-29"},{"SOURCE_ROW_NUMBER":"104184","CASSETTE_NO":"57468478","SAMPLE_DT":"07/31/2003","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-07-31"},{"SOURCE_ROW_NUMBER":"160713","CASSETTE_NO":"57447144","SAMPLE_DT":"01/24/2003","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-01-24"},{"SOURCE_ROW_NUMBER":"91979","CASSETTE_NO":"57431039","SAMPLE_DT":"11/20/2002","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-11-20"},{"SOURCE_ROW_NUMBER":"151301","CASSETTE_NO":"57432027","SAMPLE_DT":"01/17/2002","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-17"},{"SOURCE_ROW_NUMBER":"118568","CASSETTE_NO":"57385392","SAMPLE_DT":"11/05/2001","QUARTZ_PCT":"09.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-05"},{"SOURCE_ROW_NUMBER":"88617","CASSETTE_NO":"57385633","SAMPLE_DT":"11/05/2001","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-05"},{"SOURCE_ROW_NUMBER":"77262","CASSETTE_NO":"57346134","SAMPLE_DT":"08/20/2001","QUARTZ_PCT":"00.7","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-08-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":365,"firstDate":"2000-01-13","lastDate":"2004-04-19","metrics":{"ss":159,"amountDue":65016,"contested":0,"amountPaid":1401,"recentRows":0,"section104d":8,"unterminated":3,"proposedPenalty":65016},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"933835","VIOLATION_NO":"7404285","VIOLATION_ISSUE_DT":"04/19/2004","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"6","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2004","PROPOSED_PENALTY":"305","AMOUNT_DUE":"305","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"933834","VIOLATION_NO":"7404284","VIOLATION_ISSUE_DT":"04/19/2004","SIG_SUB":"N","PART_SECTION":"75.1100-2(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"933833","VIOLATION_NO":"7404283","VIOLATION_ISSUE_DT":"04/19/2004","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2004","PROPOSED_PENALTY":"191","AMOUNT_DUE":"191","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"933832","VIOLATION_NO":"7404282","VIOLATION_ISSUE_DT":"04/19/2004","SIG_SUB":"N","PART_SECTION":"75.1106-3(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"933831","VIOLATION_NO":"7404281","VIOLATION_ISSUE_DT":"04/19/2004","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"933830","VIOLATION_NO":"7404280","VIOLATION_ISSUE_DT":"04/19/2004","SIG_SUB":"Y","PART_SECTION":"75.208","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2004","PROPOSED_PENALTY":"191","AMOUNT_DUE":"191","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"933753","VIOLATION_NO":"7408068","VIOLATION_ISSUE_DT":"03/22/2004","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"933752","VIOLATION_NO":"7408067","VIOLATION_ISSUE_DT":"03/22/2004","SIG_SUB":"Y","PART_SECTION":"75.512","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"03/23/2004","PROPOSED_PENALTY":"3000","AMOUNT_DUE":"3000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"933751","VIOLATION_NO":"7408066","VIOLATION_ISSUE_DT":"03/22/2004","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2004","PROPOSED_PENALTY":"191","AMOUNT_DUE":"191","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"933750","VIOLATION_NO":"7408065","VIOLATION_ISSUE_DT":"03/22/2004","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"03/23/2004","PROPOSED_PENALTY":"3000","AMOUNT_DUE":"3000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"933749","VIOLATION_NO":"7408064","VIOLATION_ISSUE_DT":"03/22/2004","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"03/23/2004","PROPOSED_PENALTY":"3400","AMOUNT_DUE":"3400","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"933748","VIOLATION_NO":"7408063","VIOLATION_ISSUE_DT":"03/22/2004","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-03-22"}]}],"safety":{"href":"/api/v1/mines/1517962/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517962/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1106-3","heading":"Storage of liquefied and nonliquefied compressed gas cylinders; requirements.","id":"75.1106-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:\n\n(1) Clearly marked and identified as to their contents in accordance with Department of Transportation regulations.\n\n(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or otherwise secured against being accidently tipped over.\n\n(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.\n\n(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.\n\n(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.\n\n[36 FR 22061, Nov. 19, 1971]","occurrenceCount":1},{"chapter":"I","heading":"Warning devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.208","part":"75","subchapter":"O","subpart":"C","id":"75.208","citation":"30 CFR 75.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517962","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}