{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"1517961","name":"Feds Creek Mine","status":"Abandoned","status_date":"2001-08-13","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Leslie","nearest_town":"Chappell","operator_id":"P23317","operator_name":"Bledsoe Coal Corp","controller_id":"C13562","controller_name":"James River Coal Company","district":"C07","office":"Barbourville KY Field Office","employees":0,"latitude":36.9872,"longitude":-83.3267},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":757},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517961","name":"Feds Creek Mine"},"operator":{"type":"operator","id":"P23317","name":"Bledsoe Coal Corp"},"controller":{"type":"controller","id":"C13562","name":"James River Coal Company"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1517961","name":"Feds Creek Mine"},"validFrom":"1995-06-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1517961|C13562|1995-06-20|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23317","name":"Bledsoe Coal Corp"},"object":{"type":"mine","id":"1517961","name":"Feds Creek Mine"},"validFrom":"1997-07-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1517961|P23317|1997-07-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P23317","name":"Bledsoe Coal Corp"},"validFrom":"1997-07-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517961","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1517961|P23317|1997-07-01|C13562|1995-06-20|90412"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":35,"firstDate":"2000-02-03","lastDate":"2001-07-24","metrics":{"daysLost":731,"injuries":27,"fatalities":0,"recentRows":0,"restrictedDays":15,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"229424","DOCUMENT_NO":"220012140052","ACCIDENT_DT":"07/24/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE WAS CUTTING TIMBERS WITH A CROSSCUT SAW. HE CUT HIS THUMB.","sourceDate":"2001-07-24"},{"SOURCE_ROW_NUMBER":"57232","DOCUMENT_NO":"220011350006","ACCIDENT_DT":"05/08/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"14","NARRATIVE":"EMPLOYEE CAUGHT HIS LEFT LEG BETWEEN THE ROOF BOLTER HEAD AND THE FRAME OF THE MACHINE WHILE WORKING ON THE UNIT.","sourceDate":"2001-05-08"},{"SOURCE_ROW_NUMBER":"91603","DOCUMENT_NO":"220010730003","ACCIDENT_DT":"03/13/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"71","NARRATIVE":"EMPLOYEE ALLEGES HE STRAINED HIS BACK PITCHING TIMBERS ON 001 SECTION.","sourceDate":"2001-03-13"},{"SOURCE_ROW_NUMBER":"203512","DOCUMENT_NO":"220010930039","ACCIDENT_DT":"03/06/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"42","NARRATIVE":"EE ALLEGES HE TWISTED HIS LEFT KNEE WHEN HE TURNED TO INSTALL ROOF BOLTS.","sourceDate":"2001-03-06"},{"SOURCE_ROW_NUMBER":"74416","DOCUMENT_NO":"220010660004","ACCIDENT_DT":"03/05/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","NARRATIVE":"EE WAS REPAIRING A SCOOP OUTSIDE AND FELL ON SCOOP CUTTING HIS LEFT HAND.","sourceDate":"2001-03-05"},{"SOURCE_ROW_NUMBER":"100150","DOCUMENT_NO":"220010660010","ACCIDENT_DT":"03/02/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"37","NARRATIVE":"EMPLOYEE ALLEGES HE STRAINED HIS GROIN WHILE LIFTING A RIB RAIL ON THE CONTINUOUS MINER.","sourceDate":"2001-03-02"},{"SOURCE_ROW_NUMBER":"229425","DOCUMENT_NO":"220010220034","ACCIDENT_DT":"01/06/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"84","NARRATIVE":"EE ALLEGES HE TWISTED HIS LEFT KNEE WHEN HE STEPPED ON A CONCRETE BLOCK, HOWEVER, MEDICATL RECORDS INDICUTE HE HAS ALREADY BEEN TREATION WITH A DR FOR LEFT KNEE DISORDER.","sourceDate":"2001-01-06"},{"SOURCE_ROW_NUMBER":"70129","DOCUMENT_NO":"220003550033","ACCIDENT_DT":"12/16/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"29","NARRATIVE":"EE ALLEGES HE STRAINED HIS BACK WHILE INSTALLING BELT STRUCTURE FOR A NEW PANEL.","sourceDate":"2000-12-16"},{"SOURCE_ROW_NUMBER":"139020","DOCUMENT_NO":"220003320054","ACCIDENT_DT":"11/13/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNINTENTIONAL FALL OF ROOF DISCOVERED ON THE WEEKLY EXAM AT THE #53 ENTRY 001 SECTION SUBMAINS THE FALL WAS APPROX 40'X48\"X20'","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"199171","DOCUMENT_NO":"220003210045","ACCIDENT_DT":"11/01/2000","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Continuous miner helper, Coal mole helper, Bridgeman","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE WAS STRUCK ON NOSE BY BELT LIFTER.","sourceDate":"2000-11-01"},{"SOURCE_ROW_NUMBER":"156303","DOCUMENT_NO":"220002990005","ACCIDENT_DT":"10/20/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNINTENTIONAL FALL OF ROOF WAS DISCOVERED AT BREAK #40 ON #2 BELT IN THE #3 RIGHT BREAK. THE FALL WAS APP. 18' X 15' X 4-9'.","sourceDate":"2000-10-20"},{"SOURCE_ROW_NUMBER":"246654","DOCUMENT_NO":"220003080007","ACCIDENT_DT":"09/21/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"EMPLOYEE ALLEGES HE STRAINED HIS BACK WHILE MOVING BELT STAND. EMPLOYEE STARTED MISSING WORK DUE TO THIS ACCIDENT ON 10-31-00.","sourceDate":"2000-09-21"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2001-08-13","lastDate":"2001-08-13","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":60,"firstDate":"2000-02-15","lastDate":"2001-07-18","metrics":{"ss":15,"delinquent":60,"recentRows":0,"paidPenalty":6568,"proposedPenalty":8368,"currentAssessment":6568},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1097397","VIOLATION_NO":"7454800","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097396","VIOLATION_NO":"7454799","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097395","VIOLATION_NO":"7454798","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097394","VIOLATION_NO":"7454797","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.362(d)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097393","VIOLATION_NO":"7454796","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097392","VIOLATION_NO":"7454795","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.523-2(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097391","VIOLATION_NO":"7454794","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.523-3(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097390","VIOLATION_NO":"7454793","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097389","VIOLATION_NO":"7454792","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.1103","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097388","VIOLATION_NO":"7454791","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"75.1101","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097387","VIOLATION_NO":"7454790","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"1097386","VIOLATION_NO":"7454789","ISSUE_DT":"07/18/2001","CFR_STANDARD_CD":"77.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-18"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2,"firstDate":"2000-10-03","lastDate":"2001-06-06","metrics":{"appeals":0,"decisions":2,"recentRows":0,"decisionPenalty":1800,"originalPenalty":3684},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"234061","VIOLATION_NO":"7454191","DOCKET_NO":"KENT20010087","DECISION_DT":"06/06/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3500.00","DECISION_PENALTY_AMT":"1700.00","JUDGE_FIRST_NAME":"Irwin","JUDGE_LAST_NAME":"Schroeder","sourceDate":"2001-06-06"},{"SOURCE_ROW_NUMBER":"234060","VIOLATION_NO":"7450381","DOCKET_NO":"KENT20000173","DECISION_DT":"10/03/2000","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"184.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2000-10-03"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":208,"firstDate":"2000-01-12","lastDate":"2009-01-07","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":23,"validSamples":185,"maxConcentration":3.905,"concentrationTotal":148.761},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"173903","CASS_NUM":"50977924","SMP_TAKEN_DT":"1/7/2009","CONC":".162","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-01-07"},{"SOURCE_ROW_NUMBER":"920342","CASS_NUM":"50586622","SMP_TAKEN_DT":"7/25/2001","CONC":".412","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-07-25"},{"SOURCE_ROW_NUMBER":"1592925","CASS_NUM":"57337975","SMP_TAKEN_DT":"6/27/2001","CONC":".128","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"1288654","CASS_NUM":"57338032","SMP_TAKEN_DT":"6/27/2001","CONC":".487","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"1027201","CASS_NUM":"57337971","SMP_TAKEN_DT":"6/27/2001","CONC":".69","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"901717","CASS_NUM":"57337526","SMP_TAKEN_DT":"6/27/2001","CONC":"1.13","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"838817","CASS_NUM":"57337988","SMP_TAKEN_DT":"6/27/2001","CONC":".852","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"695780","CASS_NUM":"57337966","SMP_TAKEN_DT":"6/27/2001","CONC":".684","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"692480","CASS_NUM":"57337951","SMP_TAKEN_DT":"6/27/2001","CONC":".448","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"131115","CASS_NUM":"57338005","SMP_TAKEN_DT":"6/27/2001","CONC":".174","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BELT MAN/CONVEYOR MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"109611","CASS_NUM":"57337521","SMP_TAKEN_DT":"6/27/2001","CONC":".372","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"1162212","CASS_NUM":"50586590","SMP_TAKEN_DT":"5/25/2001","CONC":"1.014","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-05-25"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":3,"firstDate":"2000-03-28","lastDate":"2001-02-20","metrics":{"linkedIssuances":3},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":219,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":57,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1997-07-01","lastDate":"1997-07-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":37,"firstDate":"2000-02-15","lastDate":"2001-07-17","metrics":{"inspectors":47,"recentRows":0,"onSiteHours":633,"inspectionHours":1188.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"430204","EVENT_NO":"4219303","INSPECTION_BEGIN_DT":"07/17/2001","INSPECTION_END_DT":"08/07/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"74","SUM_TOTAL_ON_SITE_HOURS":"37","sourceDate":"2001-07-17"},{"SOURCE_ROW_NUMBER":"649574","EVENT_NO":"4220779","INSPECTION_BEGIN_DT":"06/27/2001","INSPECTION_END_DT":"07/02/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"745721","EVENT_NO":"4209739","INSPECTION_BEGIN_DT":"05/20/2001","INSPECTION_END_DT":"05/21/2001","ACTIVITY_CODE":"CBC","ACTIVITY":"ELECTRICAL SPOT INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2001-05-20"},{"SOURCE_ROW_NUMBER":"75759","EVENT_NO":"4209592","INSPECTION_BEGIN_DT":"04/16/2001","INSPECTION_END_DT":"06/28/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"43","SUM_TOTAL_ON_SITE_HOURS":"24","sourceDate":"2001-04-16"},{"SOURCE_ROW_NUMBER":"376852","EVENT_NO":"4220751","INSPECTION_BEGIN_DT":"04/11/2001","INSPECTION_END_DT":"04/17/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2001-04-11"},{"SOURCE_ROW_NUMBER":"180153","EVENT_NO":"4220749","INSPECTION_BEGIN_DT":"04/06/2001","INSPECTION_END_DT":"04/19/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2001-04-06"},{"SOURCE_ROW_NUMBER":"272919","EVENT_NO":"4209184","INSPECTION_BEGIN_DT":"02/22/2001","INSPECTION_END_DT":"03/30/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2001-02-22"},{"SOURCE_ROW_NUMBER":"13969","EVENT_NO":"4209185","INSPECTION_BEGIN_DT":"02/22/2001","INSPECTION_END_DT":"03/30/2001","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"140","SUM_TOTAL_ON_SITE_HOURS":"82.5","sourceDate":"2001-02-22"},{"SOURCE_ROW_NUMBER":"1081567","EVENT_NO":"4220730","INSPECTION_BEGIN_DT":"02/17/2001","INSPECTION_END_DT":"03/22/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.5","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2001-02-17"},{"SOURCE_ROW_NUMBER":"1137710","EVENT_NO":"4220726","INSPECTION_BEGIN_DT":"02/09/2001","INSPECTION_END_DT":"02/13/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2001-02-09"},{"SOURCE_ROW_NUMBER":"98704","EVENT_NO":"4220727","INSPECTION_BEGIN_DT":"02/09/2001","INSPECTION_END_DT":"02/13/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2001-02-09"},{"SOURCE_ROW_NUMBER":"1092000","EVENT_NO":"4218398","INSPECTION_BEGIN_DT":"01/23/2001","INSPECTION_END_DT":"02/04/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"28","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2001-01-23"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001-Q4":{"hours":0,"employees":0,"production":0},"2001-Q3":{"hours":6194,"employees":30,"production":26965},"2001-Q2":{"hours":18636,"employees":30,"production":94135},"2001-Q1":{"hours":38011,"employees":59,"production":250946},"2000-Q4":{"hours":36629,"employees":58,"production":191389},"2000-Q3":{"hours":23173,"employees":51,"production":118294},"2000-Q2":{"hours":22896,"employees":36,"production":139378},"2000-Q1":{"hours":20526,"employees":34,"production":197289}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":103224,"employees":45,"production":646350},"2001":{"hours":62841,"employees":40,"production":372046}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":11,"firstDate":"2000-02-24","lastDate":"2001-02-09","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":937,"pelDoseTotal":698},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"65632","EVENT_NO":"4220727","SURVEY_DATE":"02/09/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"210","PEL_DOSE_90":"197","SURVEY_TYPE":"I","sourceDate":"2001-02-09"},{"SOURCE_ROW_NUMBER":"65631","EVENT_NO":"4220727","SURVEY_DATE":"02/09/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"122","PEL_DOSE_90":"104","SURVEY_TYPE":"I","sourceDate":"2001-02-09"},{"SOURCE_ROW_NUMBER":"65630","EVENT_NO":"4220727","SURVEY_DATE":"02/09/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"53","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2001-02-09"},{"SOURCE_ROW_NUMBER":"65629","EVENT_NO":"4219029","SURVEY_DATE":"05/03/2000","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"30","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2000-05-03"},{"SOURCE_ROW_NUMBER":"65628","EVENT_NO":"4219028","SURVEY_DATE":"05/03/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"098","ACT_DOSE_85":"58","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2000-05-03"},{"SOURCE_ROW_NUMBER":"65627","EVENT_NO":"4219028","SURVEY_DATE":"05/03/2000","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"067","ACT_DOSE_85":"112","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2000-05-03"},{"SOURCE_ROW_NUMBER":"65626","EVENT_NO":"4219028","SURVEY_DATE":"05/03/2000","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"067","ACT_DOSE_85":"99","PEL_DOSE_90":"68","SURVEY_TYPE":"I","sourceDate":"2000-05-03"},{"SOURCE_ROW_NUMBER":"65625","EVENT_NO":"4219028","SURVEY_DATE":"05/03/2000","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"57","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2000-05-03"},{"SOURCE_ROW_NUMBER":"65624","EVENT_NO":"4218340","SURVEY_DATE":"02/24/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"62","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2000-02-24"},{"SOURCE_ROW_NUMBER":"65623","EVENT_NO":"4218340","SURVEY_DATE":"02/24/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"102","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2000-02-24"},{"SOURCE_ROW_NUMBER":"65622","EVENT_NO":"4218340","SURVEY_DATE":"02/24/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"32","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2000-02-24"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":39,"firstDate":"2000-02-24","lastDate":"2001-06-27","metrics":{"recentRows":0,"voidSamples":5,"maxQuartzPct":16.4,"validSamples":34,"quartzPctTotal":225.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"142589","CASSETTE_NO":"57338032","SAMPLE_DT":"06/27/2001","QUARTZ_PCT":"09.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"91131","CASSETTE_NO":"57337988","SAMPLE_DT":"06/27/2001","QUARTZ_PCT":"16.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"64905","CASSETTE_NO":"57337966","SAMPLE_DT":"06/27/2001","QUARTZ_PCT":"10.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"2683","CASSETTE_NO":"57337951","SAMPLE_DT":"06/27/2001","QUARTZ_PCT":"12.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"87622","CASSETTE_NO":"50597944","SAMPLE_DT":"04/24/2001","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2001-04-24"},{"SOURCE_ROW_NUMBER":"40939","CASSETTE_NO":"50597938","SAMPLE_DT":"04/24/2001","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-24"},{"SOURCE_ROW_NUMBER":"15956","CASSETTE_NO":"57347309","SAMPLE_DT":"04/11/2001","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-11"},{"SOURCE_ROW_NUMBER":"166602","CASSETTE_NO":"50586601","SAMPLE_DT":"03/23/2001","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-23"},{"SOURCE_ROW_NUMBER":"146327","CASSETTE_NO":"50586625","SAMPLE_DT":"03/23/2001","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-23"},{"SOURCE_ROW_NUMBER":"147617","CASSETTE_NO":"57348952","SAMPLE_DT":"03/08/2001","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-08"},{"SOURCE_ROW_NUMBER":"101044","CASSETTE_NO":"57348910","SAMPLE_DT":"03/08/2001","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-08"},{"SOURCE_ROW_NUMBER":"29097","CASSETTE_NO":"57348893","SAMPLE_DT":"03/08/2001","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":63,"firstDate":"2000-02-15","lastDate":"2001-07-18","metrics":{"ss":15,"amountDue":6568,"contested":1,"amountPaid":6568,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":8368},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"934068","VIOLATION_NO":"7454800","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/23/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934067","VIOLATION_NO":"7454799","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/23/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934066","VIOLATION_NO":"7454798","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934065","VIOLATION_NO":"7454797","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"N","PART_SECTION":"75.362(d)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934064","VIOLATION_NO":"7454796","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/18/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934063","VIOLATION_NO":"7454795","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"Y","PART_SECTION":"75.523-2(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2001","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"207","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934062","VIOLATION_NO":"7454794","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2001","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"207","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934061","VIOLATION_NO":"7454793","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/23/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934060","VIOLATION_NO":"7454792","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"N","PART_SECTION":"75.1103","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/23/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934059","VIOLATION_NO":"7454791","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"N","PART_SECTION":"75.1101","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/23/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934058","VIOLATION_NO":"7454790","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"N","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"934057","VIOLATION_NO":"7454789","VIOLATION_ISSUE_DT":"07/18/2001","SIG_SUB":"Y","PART_SECTION":"77.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2001","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"207","CONTESTED_IND":"N","sourceDate":"2001-07-18"}]}],"safety":{"href":"/api/v1/mines/1517961/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517961/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":1},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment; performance requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-2","part":"75","subchapter":"O","subpart":"F","id":"75.523-2","citation":"30 CFR 75.523-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Automatic fire warning devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103","part":"75","subchapter":"O","subpart":"L","id":"75.1103","citation":"30 CFR 75.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Deluge-type water sprays, foam generators; main and secondary belt-conveyor drives.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1101","part":"75","subchapter":"O","subpart":"L","id":"75.1101","citation":"30 CFR 75.1101","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517961","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}