{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1517944","name":"Black Gold 3","status":"Abandoned","status_date":"2000-08-17","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Hopkins","nearest_town":"Nortonville","operator_id":"P21230","operator_name":"Sunrise Coal Inc","controller_id":"C14280","controller_name":"Ray  Jones","district":"C10","office":"Madisonville KY Field Office","employees":0,"latitude":37.1736,"longitude":-87.5089},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":106},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517944","name":"Black Gold 3"},"operator":{"type":"operator","id":"P21230","name":"Sunrise Coal Inc"},"controller":{"type":"controller","id":"C14280","name":"Ray  Jones"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14280","name":"Ray  Jones"},"object":{"type":"mine","id":"1517944","name":"Black Gold 3"},"validFrom":"1990-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517944|C14280|1990-11-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21230","name":"Sunrise Coal Inc"},"object":{"type":"mine","id":"1517944","name":"Black Gold 3"},"validFrom":"1997-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517944|P21230|1997-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14280","name":"Ray  Jones"},"object":{"type":"operator","id":"P21230","name":"Sunrise Coal Inc"},"validFrom":"1997-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517944","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517944|P21230|1997-06-01|C14280|1990-11-01|92407"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":8,"firstDate":"2000-01-10","lastDate":"2000-04-04","metrics":{"daysLost":170,"injuries":6,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"203504","DOCUMENT_NO":"220001050078","ACCIDENT_DT":"04/04/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL 2ND WEST, #4 ENTRY #12 XC 1100 OUTBY LOADING POINT. APP 45'L X 28'W 6 TO 7'H.","sourceDate":"2000-04-04"},{"SOURCE_ROW_NUMBER":"173436","DOCUMENT_NO":"220001050062","ACCIDENT_DT":"04/01/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"58","NARRATIVE":"EMPLOYEE DRILLED HOLE FOR ROOF BOLT, STEEL HUNG IN ROOF, AS HE REACHED FOR STEEL IT DROPPED OUT OF ROOF AND CAUGHT FINGER BETWEEN DRILL HEAD AND STEEL.","sourceDate":"2000-04-01"},{"SOURCE_ROW_NUMBER":"74411","DOCUMENT_NO":"220000750009","ACCIDENT_DT":"03/03/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","DAYS_LOST":"77","NARRATIVE":"EE WAS TAKING DOWN SOME LOOSE ROCK WITH COAL BAR IN #2 ROOM APPX 40' OUTBY THE FACE. TOOK DOWN ONE PIECE AND AS HE WAS PREPARING TO TAKE DOWN ANOTHER, A PIECE OF ROCK FELL STRIKING HIM IN THE BACK BETWEEEN THE SHOULDER BLADES.","sourceDate":"2000-03-03"},{"SOURCE_ROW_NUMBER":"272354","DOCUMENT_NO":"220000690026","ACCIDENT_DT":"03/01/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"EE WAS INSTALLING ROOF BOLTS IN #1 ENTRY 2ND WEST AS HE INSERTED ROOF BOLT IN HOLE A PIECE OF SLATE (1/2\" X 12\" X 16\") FELL AND CAUGHT FINGER BETWEEN ROCK AND BOLTER FRAME.","sourceDate":"2000-03-01"},{"SOURCE_ROW_NUMBER":"35800","DOCUMENT_NO":"220000590074","ACCIDENT_DT":"02/02/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL WAS FOUND IN #3 ENTRY, #9 XC 2ND WEST 300' OUTBY LOADING POINT FALL 23'L X 18'W X 0 TO 4'H.","sourceDate":"2000-02-02"},{"SOURCE_ROW_NUMBER":"190577","DOCUMENT_NO":"220000320009","ACCIDENT_DT":"01/21/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"32","NARRATIVE":"EE STATED WAS INSTALLING ROOF BOLTS IN #7. REPORTED TO FORMAN THAT HE GOT UP FROM HIS KNEES TO MOVE BOLTER, FELT A POP IN HIS BACK.","sourceDate":"2000-01-21"},{"SOURCE_ROW_NUMBER":"194825","DOCUMENT_NO":"220000200007","ACCIDENT_DT":"01/15/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","NARRATIVE":"EE STARTED ENDLOADER TO LET IT WARM UP. AS HE WAS GETTING OFF LOADER, FOOT SLIPPED ON BOTTOM STEP. HE STUMBLED BACKWARD AND STRUCK HIS HEAD ON CORNER OF FUEL STORAGE BOX.","sourceDate":"2000-01-15"},{"SOURCE_ROW_NUMBER":"147660","DOCUMENT_NO":"220000380163","ACCIDENT_DT":"01/10/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Supply man, Supply worker, Nipper","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"ON 1/22/00 EE REPORTED TO HIS FOREMAN THAT HE WAS UNLOADING OIL ON UNIT 1/10/00 HE FELT A TWINGE IN HIS NECK, ON 1/26/00 REPORTED NECK STILL BOTHERING HIM WAS GOING TO DR.","sourceDate":"2000-01-10"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2000-08-17","lastDate":"2000-08-17","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":8,"firstDate":"2000-01-12","lastDate":"2000-06-05","metrics":{"ss":1,"delinquent":8,"recentRows":0,"paidPenalty":627,"proposedPenalty":627,"currentAssessment":627},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1251483","VIOLATION_NO":"7641572","ISSUE_DT":"06/05/2000","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-06-05"},{"SOURCE_ROW_NUMBER":"1251482","VIOLATION_NO":"7641571","ISSUE_DT":"05/16/2000","CFR_STANDARD_CD":"75.1106-3(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-05-16"},{"SOURCE_ROW_NUMBER":"1253444","VIOLATION_NO":"7641614","ISSUE_DT":"03/13/2000","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"242.00","CURRENT_ASSESSMENT_AMT":"242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-03-13"},{"SOURCE_ROW_NUMBER":"1253332","VIOLATION_NO":"7641666","ISSUE_DT":"03/10/2000","CFR_STANDARD_CD":"75.1107-4(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-03-10"},{"SOURCE_ROW_NUMBER":"1253331","VIOLATION_NO":"7641662","ISSUE_DT":"03/03/2000","CFR_STANDARD_CD":"75.523-2(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-03-03"},{"SOURCE_ROW_NUMBER":"1252777","VIOLATION_NO":"7641132","ISSUE_DT":"01/19/2000","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-01-19"},{"SOURCE_ROW_NUMBER":"1253153","VIOLATION_NO":"7641482","ISSUE_DT":"01/12/2000","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-01-12"},{"SOURCE_ROW_NUMBER":"1253152","VIOLATION_NO":"7641481","ISSUE_DT":"01/12/2000","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-01-12"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":44,"firstDate":"2000-01-17","lastDate":"2000-06-14","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":43,"maxConcentration":2.705,"concentrationTotal":39.048},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1330352","CASS_NUM":"57285548","SMP_TAKEN_DT":"6/14/2000","CONC":".733","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"899361","CASS_NUM":"57285412","SMP_TAKEN_DT":"6/14/2000","CONC":"1.224","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"711347","CASS_NUM":"57285547","SMP_TAKEN_DT":"6/14/2000","CONC":".661","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"609412","CASS_NUM":"57285442","SMP_TAKEN_DT":"6/14/2000","CONC":".109","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"528808","CASS_NUM":"57285483","SMP_TAKEN_DT":"6/14/2000","CONC":".552","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"457021","CASS_NUM":"57285552","SMP_TAKEN_DT":"6/14/2000","CONC":".767","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"4251","CASS_NUM":"57285407","SMP_TAKEN_DT":"6/14/2000","CONC":".583","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"499075","CASS_NUM":"50540495","SMP_TAKEN_DT":"5/30/2000","CONC":"1.121","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-05-30"},{"SOURCE_ROW_NUMBER":"787962","CASS_NUM":"50540493","SMP_TAKEN_DT":"5/26/2000","CONC":".356","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-05-26"},{"SOURCE_ROW_NUMBER":"368258","CASS_NUM":"50540500","SMP_TAKEN_DT":"5/24/2000","CONC":".681","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-05-24"},{"SOURCE_ROW_NUMBER":"381314","CASS_NUM":"50540494","SMP_TAKEN_DT":"5/23/2000","CONC":".414","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-05-23"},{"SOURCE_ROW_NUMBER":"1604875","CASS_NUM":"57285349","SMP_TAKEN_DT":"5/17/2000","CONC":"1.327","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-05-17"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1997-06-01","lastDate":"1997-06-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":14,"firstDate":"2000-01-04","lastDate":"2000-07-11","metrics":{"inspectors":20,"recentRows":0,"onSiteHours":230,"inspectionHours":396,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"932358","EVENT_NO":"4280198","INSPECTION_BEGIN_DT":"07/11/2000","INSPECTION_END_DT":"08/30/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2000-07-11"},{"SOURCE_ROW_NUMBER":"166397","EVENT_NO":"4280244","INSPECTION_BEGIN_DT":"06/28/2000","INSPECTION_END_DT":"06/28/2000","ACTIVITY_CODE":"CFA","ACTIVITY":"MINE IDLE","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2000-06-28"},{"SOURCE_ROW_NUMBER":"449185","EVENT_NO":"4281314","INSPECTION_BEGIN_DT":"06/14/2000","INSPECTION_END_DT":"06/22/2000","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"798810","EVENT_NO":"4279248","INSPECTION_BEGIN_DT":"05/31/2000","INSPECTION_END_DT":"05/31/2000","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2000-05-31"},{"SOURCE_ROW_NUMBER":"496604","EVENT_NO":"4280234","INSPECTION_BEGIN_DT":"05/17/2000","INSPECTION_END_DT":"05/25/2000","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2000-05-17"},{"SOURCE_ROW_NUMBER":"157234","EVENT_NO":"4279072","INSPECTION_BEGIN_DT":"04/03/2000","INSPECTION_END_DT":"06/14/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"191.5","SUM_TOTAL_ON_SITE_HOURS":"113.5","sourceDate":"2000-04-03"},{"SOURCE_ROW_NUMBER":"298016","EVENT_NO":"4280194","INSPECTION_BEGIN_DT":"03/21/2000","INSPECTION_END_DT":"03/21/2000","ACTIVITY_CODE":"CED","ACTIVITY":"RESP DUST TECHNICAL INVESTIGATION","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2000-03-21"},{"SOURCE_ROW_NUMBER":"173196","EVENT_NO":"4280058","INSPECTION_BEGIN_DT":"03/13/2000","INSPECTION_END_DT":"04/14/2000","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2000-03-13"},{"SOURCE_ROW_NUMBER":"816512","EVENT_NO":"4279722","INSPECTION_BEGIN_DT":"03/07/2000","INSPECTION_END_DT":"03/07/2000","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2000-03-07"},{"SOURCE_ROW_NUMBER":"806348","EVENT_NO":"4280055","INSPECTION_BEGIN_DT":"03/01/2000","INSPECTION_END_DT":"03/07/2000","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2000-03-01"},{"SOURCE_ROW_NUMBER":"690964","EVENT_NO":"4280192","INSPECTION_BEGIN_DT":"02/17/2000","INSPECTION_END_DT":"03/31/2000","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2000-02-17"},{"SOURCE_ROW_NUMBER":"585694","EVENT_NO":"4279711","INSPECTION_BEGIN_DT":"01/19/2000","INSPECTION_END_DT":"01/19/2000","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2000-01-19"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000-Q3":{"hours":1440,"employees":3,"production":0},"2000-Q2":{"hours":20814,"employees":39,"production":95889},"2000-Q1":{"hours":23703,"employees":39,"production":102234}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":45957,"employees":39,"production":198123}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":5,"firstDate":"2000-03-01","lastDate":"2000-03-01","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":368,"pelDoseTotal":268},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"65445","EVENT_NO":"4280055","SURVEY_DATE":"03/01/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"033","ACT_DOSE_85":"61","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2000-03-01"},{"SOURCE_ROW_NUMBER":"65444","EVENT_NO":"4280055","SURVEY_DATE":"03/01/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"70","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2000-03-01"},{"SOURCE_ROW_NUMBER":"65443","EVENT_NO":"4280055","SURVEY_DATE":"03/01/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"54","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2000-03-01"},{"SOURCE_ROW_NUMBER":"65442","EVENT_NO":"4280055","SURVEY_DATE":"03/01/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"126","PEL_DOSE_90":"116","SURVEY_TYPE":"I","sourceDate":"2000-03-01"},{"SOURCE_ROW_NUMBER":"65441","EVENT_NO":"4280055","SURVEY_DATE":"03/01/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"57","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2000-03-01"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":6,"firstDate":"2000-03-13","lastDate":"2000-06-14","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":3.4,"validSamples":5,"quartzPctTotal":11.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"119802","CASSETTE_NO":"57285547","SAMPLE_DT":"06/14/2000","QUARTZ_PCT":"03.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"20564","CASSETTE_NO":"57285412","SAMPLE_DT":"06/14/2000","QUARTZ_PCT":"02.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-06-14"},{"SOURCE_ROW_NUMBER":"152037","CASSETTE_NO":"57285436","SAMPLE_DT":"05/17/2000","QUARTZ_PCT":"00.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-05-17"},{"SOURCE_ROW_NUMBER":"165207","CASSETTE_NO":"50540499","SAMPLE_DT":"04/17/2000","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2000-04-17"},{"SOURCE_ROW_NUMBER":"30817","CASSETTE_NO":"50495851","SAMPLE_DT":"03/20/2000","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-03-20"},{"SOURCE_ROW_NUMBER":"44137","CASSETTE_NO":"57210816","SAMPLE_DT":"03/13/2000","QUARTZ_PCT":"01.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-03-13"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":8,"firstDate":"2000-01-12","lastDate":"2000-06-05","metrics":{"ss":1,"amountDue":627,"contested":0,"amountPaid":627,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":627},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"932779","VIOLATION_NO":"7641572","VIOLATION_ISSUE_DT":"06/05/2000","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/05/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-06-05"},{"SOURCE_ROW_NUMBER":"932778","VIOLATION_NO":"7641571","VIOLATION_ISSUE_DT":"05/16/2000","SIG_SUB":"N","PART_SECTION":"75.1106-3(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-05-16"},{"SOURCE_ROW_NUMBER":"932777","VIOLATION_NO":"7641614","VIOLATION_ISSUE_DT":"03/13/2000","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/13/2000","PROPOSED_PENALTY":"242","AMOUNT_DUE":"242","AMOUNT_PAID":"242","CONTESTED_IND":"N","sourceDate":"2000-03-13"},{"SOURCE_ROW_NUMBER":"932773","VIOLATION_NO":"7641666","VIOLATION_ISSUE_DT":"03/10/2000","SIG_SUB":"N","PART_SECTION":"75.1107-4(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/10/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-03-10"},{"SOURCE_ROW_NUMBER":"932772","VIOLATION_NO":"7641662","VIOLATION_ISSUE_DT":"03/03/2000","SIG_SUB":"N","PART_SECTION":"75.523-2(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/03/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-03-03"},{"SOURCE_ROW_NUMBER":"932776","VIOLATION_NO":"7641132","VIOLATION_ISSUE_DT":"01/19/2000","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"12","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/27/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-01-19"},{"SOURCE_ROW_NUMBER":"932775","VIOLATION_NO":"7641482","VIOLATION_ISSUE_DT":"01/12/2000","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/12/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-01-12"},{"SOURCE_ROW_NUMBER":"932774","VIOLATION_NO":"7641481","VIOLATION_ISSUE_DT":"01/12/2000","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/12/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-01-12"}]}],"safety":{"href":"/api/v1/mines/1517944/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517944/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1106-3","heading":"Storage of liquefied and nonliquefied compressed gas cylinders; requirements.","id":"75.1106-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:\n\n(1) Clearly marked and identified as to their contents in accordance with Department of Transportation regulations.\n\n(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or otherwise secured against being accidently tipped over.\n\n(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.\n\n(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.\n\n(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.\n\n[36 FR 22061, Nov. 19, 1971]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment; performance requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-2","part":"75","subchapter":"O","subpart":"F","id":"75.523-2","citation":"30 CFR 75.523-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517944","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}