{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1517651","name":"Mine #1","status":"Abandoned and Sealed","status_date":"2013-09-30","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Sidney","operator_id":"P16149","operator_name":"Rockhouse Energy Mining","controller_id":"0127923","controller_name":"Alpha Natural Resources Holdings, Inc","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.665277,"longitude":-82.379166},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":18432},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517651","name":"Mine #1"},"operator":{"type":"operator","id":"P16149","name":"Rockhouse Energy Mining"},"controller":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"1517651","name":"Mine #1"},"validFrom":"1984-10-04","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|C02508|1984-10-04|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23103","name":"Rockhouse Energy Mining Company"},"object":{"type":"mine","id":"1517651","name":"Mine #1"},"validFrom":"1995-03-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|P23103|1995-03-01|2011-05-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"1517651","name":"Mine #1"},"validFrom":"1995-03-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|C02508|1995-03-01|2011-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P23103","name":"Rockhouse Energy Mining Company"},"validFrom":"1995-03-01","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"1517651","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|P23103|1995-03-01|C02508|1995-03-01|59394"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P16149","name":"Rockhouse Energy Mining"},"object":{"type":"mine","id":"1517651","name":"Mine #1"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|P16149|2011-06-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"1517651","name":"Mine #1"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P16149","name":"Rockhouse Energy Mining"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"1517651","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|P16149|2011-06-01|0041211|2011-06-01|1865"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"1517651","name":"Mine #1"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|0041211|2011-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P23103","name":"Rockhouse Energy Mining Company"},"validFrom":"2011-06-01","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"1517651","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|P23103|1995-03-01|0041211|2011-06-01|2246"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P16149","name":"Rockhouse Energy Mining"},"validFrom":"2011-06-01","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"1517651","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|P16149|2011-06-01|C02508|1984-10-04|59197"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"1517651","name":"Mine #1"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|0127923|2016-07-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P16149","name":"Rockhouse Energy Mining"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517651","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517651|P16149|2011-06-01|0127923|2016-07-26|25396"}}],"coverage":{"historyRecords":5,"edgeCount":12,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":288,"firstDate":"2000-01-07","lastDate":"2014-04-28","metrics":{"daysLost":8103,"injuries":227,"fatalities":3,"recentRows":0,"restrictedDays":212,"contractorRecords":16},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"40047","DOCUMENT_NO":"220141620002","ACCIDENT_DT":"04/28/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Claim filed for pneumoconiosis. X-ray read date of 4/28/2014. Termination date 2/19/2010.","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"224997","DOCUMENT_NO":"220140940001","ACCIDENT_DT":"03/31/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Supply man, Supply worker, Nipper","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Claim filed for hearing loss.","sourceDate":"2014-03-31"},{"SOURCE_ROW_NUMBER":"272328","DOCUMENT_NO":"220130310049","ACCIDENT_DT":"09/07/2012","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"ALL OTHER OCCUPATIONAL ILLNESSES","ACCIDENT_TYPE":"NEC","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping to remove the feeder. Material around the feeder broke loose and caused employee to stumble and fall. Employee continued working until 10/29/12 when he began missing work. On 1/28/13 we were notified that this was an occupational illness due to mental stress.","sourceDate":"2012-09-07"},{"SOURCE_ROW_NUMBER":"95830","DOCUMENT_NO":"220122210023","ACCIDENT_DT":"08/06/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While racking conveyor belt EE's pinky finger was caught between a pulley on a sheave wheel and the rope attached to the conveyor belt, resulting in a fracture to the tip of his pinky finger.","sourceDate":"2012-08-06"},{"SOURCE_ROW_NUMBER":"44340","DOCUMENT_NO":"220141130001","ACCIDENT_DT":"08/03/2012","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Supply man, Supply worker, Nipper","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Claim of cumulative trauma. Neck, shoulder, low back and knee pain. Diagnosed date of 1/21/2014.","sourceDate":"2012-08-03"},{"SOURCE_ROW_NUMBER":"95829","DOCUMENT_NO":"220121800005","ACCIDENT_DT":"06/04/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"58","NARRATIVE":"Employee was removing a pin to unhook the motor from a roof bolter it was towing. When he pulled on the pin the bolter shifted causing the pin to shift smashing his middle and ring finger on his left hand","sourceDate":"2012-06-04"},{"SOURCE_ROW_NUMBER":"272327","DOCUMENT_NO":"220121300009","ACCIDENT_DT":"03/05/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was hanging miner cable when he felt a pain in his lower back.  He has continued to work his regular scheduled shifts. On 4-27-12 he visited his Dr. and was given an immobilization device and continues to work his scheduled shifts.","sourceDate":"2012-03-05"},{"SOURCE_ROW_NUMBER":"22881","DOCUMENT_NO":"220113390037","ACCIDENT_DT":"11/28/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A non-injury roof fall occurred at this mine 2 breaks inby the #3 intake portal.  The fall was approximately 22'W X 20'L X 4'H.  The area has been breakered off.","sourceDate":"2011-11-28"},{"SOURCE_ROW_NUMBER":"31507","DOCUMENT_NO":"220112650001","ACCIDENT_DT":"09/10/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was using a slate bar to remove a rock from around the head jack of the continuous miner, when the bar slipped striking him in the ribs resulting in two fractured ribs.  Employee continued to work until 9-17-11 when he was diagnosed with the fracture.","sourceDate":"2011-09-10"},{"SOURCE_ROW_NUMBER":"147635","DOCUMENT_NO":"220112300006","ACCIDENT_DT":"08/08/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"151","NARRATIVE":"Employees had scaled some loose ribs in an old overcast area and was in the process of spot bolting the area. As he was putting the drill steel against the roof a piece of rib fell out knocking employee into the roof bolter controls causing a laceration to his face.","sourceDate":"2011-08-08"},{"SOURCE_ROW_NUMBER":"125814","DOCUMENT_NO":"220112140008","ACCIDENT_DT":"07/28/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While installing 4\" water line injured employee was positioned behind another employee, while other employee was hitting water line between his feet the hammer slipped striking injured employee in the mouth.","sourceDate":"2011-07-28"},{"SOURCE_ROW_NUMBER":"87367","DOCUMENT_NO":"220112860027","ACCIDENT_DT":"06/28/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was loading a joint of 6\" waterline when he felt a sharp pain in his lower back.  He has continued to work his scheduled shifts and has started physical therapy on 10/11/2011.","sourceDate":"2011-06-28"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2013-09-30","lastDate":"2013-09-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":4777,"firstDate":"2000-01-07","lastDate":"2013-09-25","metrics":{"ss":1767,"delinquent":4760,"recentRows":0,"paidPenalty":3816376.9,"proposedPenalty":4980458,"currentAssessment":3822525.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1058866","VIOLATION_NO":"8278188","ISSUE_DT":"09/25/2013","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1657.00","CURRENT_ASSESSMENT_AMT":"1657.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-09-25"},{"SOURCE_ROW_NUMBER":"1057406","VIOLATION_NO":"8273468","ISSUE_DT":"12/05/2012","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-12-05"},{"SOURCE_ROW_NUMBER":"1078506","VIOLATION_NO":"8232839","ISSUE_DT":"09/17/2012","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"634.00","CURRENT_ASSESSMENT_AMT":"634.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-17"},{"SOURCE_ROW_NUMBER":"1958067","VIOLATION_NO":"8273982","ISSUE_DT":"08/28/2012","CFR_STANDARD_CD":"75.523-3(c)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-28"},{"SOURCE_ROW_NUMBER":"1958066","VIOLATION_NO":"8273981","ISSUE_DT":"08/28/2012","CFR_STANDARD_CD":"75.1910(l)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-28"},{"SOURCE_ROW_NUMBER":"1958065","VIOLATION_NO":"8273979","ISSUE_DT":"08/27/2012","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-27"},{"SOURCE_ROW_NUMBER":"1958073","VIOLATION_NO":"8273978","ISSUE_DT":"08/23/2012","CFR_STANDARD_CD":"75.320(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-23"},{"SOURCE_ROW_NUMBER":"1958064","VIOLATION_NO":"8273975","ISSUE_DT":"08/15/2012","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-15"},{"SOURCE_ROW_NUMBER":"1958063","VIOLATION_NO":"8273974","ISSUE_DT":"08/15/2012","CFR_STANDARD_CD":"75.1714-3(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-15"},{"SOURCE_ROW_NUMBER":"1958062","VIOLATION_NO":"8273973","ISSUE_DT":"08/14/2012","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"1958061","VIOLATION_NO":"8273969","ISSUE_DT":"08/09/2012","CFR_STANDARD_CD":"75.337(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-09"},{"SOURCE_ROW_NUMBER":"1958072","VIOLATION_NO":"8273968","ISSUE_DT":"08/08/2012","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"372.00","CURRENT_ASSESSMENT_AMT":"372.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-08"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1040,"firstDate":"2000-10-19","lastDate":"2015-09-04","metrics":{"appeals":0,"decisions":1039,"recentRows":0,"decisionPenalty":2572495.9,"originalPenalty":3905964},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"333745","VIOLATION_NO":"8227264","DOCKET_NO":"KENT 2013-102","DECISION_DT":"09/04/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"3000.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2015-09-04"},{"SOURCE_ROW_NUMBER":"322576","VIOLATION_NO":"8260354","DOCKET_NO":"KENT 2012-891","DECISION_DT":"04/09/2015","DECISION_TYPE_CODE_DESC":"Vacate","ORIGINAL_PENALTY_AMT":"46600.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2015-04-09"},{"SOURCE_ROW_NUMBER":"85500","VIOLATION_NO":"8260352","DOCKET_NO":"KENT 2012-891","DECISION_DT":"04/09/2015","DECISION_TYPE_CODE_DESC":"Prevail","ORIGINAL_PENALTY_AMT":"42600.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2015-04-09"},{"SOURCE_ROW_NUMBER":"316252","VIOLATION_NO":"8265609","DOCKET_NO":"KENT 2012-376","DECISION_DT":"08/21/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-08-21"},{"SOURCE_ROW_NUMBER":"316251","VIOLATION_NO":"8260351","DOCKET_NO":"KENT 2012-376","DECISION_DT":"08/21/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-08-21"},{"SOURCE_ROW_NUMBER":"315582","VIOLATION_NO":"8265603","DOCKET_NO":"KENT 2012-376","DECISION_DT":"08/21/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"499.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-08-21"},{"SOURCE_ROW_NUMBER":"315581","VIOLATION_NO":"8260863","DOCKET_NO":"KENT 2012-376","DECISION_DT":"08/21/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"510.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-08-21"},{"SOURCE_ROW_NUMBER":"315193","VIOLATION_NO":"8265601","DOCKET_NO":"KENT 2012-376","DECISION_DT":"08/21/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"811.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-08-21"},{"SOURCE_ROW_NUMBER":"314048","VIOLATION_NO":"8258329","DOCKET_NO":"KENT 2012-247","DECISION_DT":"08/21/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-08-21"},{"SOURCE_ROW_NUMBER":"312969","VIOLATION_NO":"8265540","DOCKET_NO":"KENT 2012-247","DECISION_DT":"08/21/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"400.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-08-21"},{"SOURCE_ROW_NUMBER":"84272","VIOLATION_NO":"8265686","DOCKET_NO":"KENT 2012-733","DECISION_DT":"08/21/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-08-21"},{"SOURCE_ROW_NUMBER":"79845","VIOLATION_NO":"8260372","DOCKET_NO":"KENT 2012-247","DECISION_DT":"08/21/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-08-21"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":3710,"firstDate":"2000-01-03","lastDate":"2012-05-29","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":762,"validSamples":2948,"maxConcentration":32.247,"concentrationTotal":2859.332},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"998178","CASS_NUM":"51159706","SMP_TAKEN_DT":"5/29/2012","CONC":".809","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-29"},{"SOURCE_ROW_NUMBER":"363286","CASS_NUM":"51159739","SMP_TAKEN_DT":"5/26/2012","CONC":".378","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-26"},{"SOURCE_ROW_NUMBER":"205641","CASS_NUM":"51159731","SMP_TAKEN_DT":"5/26/2012","CONC":"1.266","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-26"},{"SOURCE_ROW_NUMBER":"1587362","CASS_NUM":"51159565","SMP_TAKEN_DT":"5/25/2012","CONC":".687","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-25"},{"SOURCE_ROW_NUMBER":"965484","CASS_NUM":"51159704","SMP_TAKEN_DT":"5/25/2012","CONC":".386","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-25"},{"SOURCE_ROW_NUMBER":"1067292","CASS_NUM":"51159721","SMP_TAKEN_DT":"5/24/2012","CONC":".799","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-24"},{"SOURCE_ROW_NUMBER":"1013792","CASS_NUM":"51159143","SMP_TAKEN_DT":"5/23/2012","CONC":"2.12","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-23"},{"SOURCE_ROW_NUMBER":"961596","CASS_NUM":"51159703","SMP_TAKEN_DT":"5/23/2012","CONC":".839","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-23"},{"SOURCE_ROW_NUMBER":"1169390","CASS_NUM":"51159138","SMP_TAKEN_DT":"5/22/2012","CONC":"1.486","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-22"},{"SOURCE_ROW_NUMBER":"154361","CASS_NUM":"51159714","SMP_TAKEN_DT":"5/22/2012","CONC":".483","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-22"},{"SOURCE_ROW_NUMBER":"1352855","CASS_NUM":"51159735","SMP_TAKEN_DT":"5/21/2012","CONC":".212","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-21"},{"SOURCE_ROW_NUMBER":"549760","CASS_NUM":"51176233","SMP_TAKEN_DT":"5/21/2012","CONC":"1.721","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-21"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":322,"firstDate":"2000-01-24","lastDate":"2012-09-11","metrics":{"linkedIssuances":322},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":724,"firstDate":"2000-07-19","lastDate":"2012-07-19","metrics":{"decisions":723,"ssChanged":211,"recentRows":0,"decisionPenalty":2179500,"proposedPenalty":3194754},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"115109","CITATION_NO":"8227264","CITATION_ISSUE_DT":"07/19/2012","DOCKET_NO":"KENT 2013-102","DECISION_DT":"09/04/2015","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"3000.00","sourceDate":"2012-07-19"},{"SOURCE_ROW_NUMBER":"365222","CITATION_NO":"8269875","CITATION_ISSUE_DT":"05/23/2012","DOCKET_NO":"KENT 2012-1365","DECISION_DT":"05/24/2013","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"127.00","DECISION_PENALTY_AMT":"127.00","sourceDate":"2012-05-23"},{"SOURCE_ROW_NUMBER":"29316","CITATION_NO":"8271008","CITATION_ISSUE_DT":"05/23/2012","DOCKET_NO":"KENT 2012-1365","DECISION_DT":"05/24/2013","CFR_STANDARD_CODE":"75.1100-2(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-05-23"},{"SOURCE_ROW_NUMBER":"255434","CITATION_NO":"8273929","CITATION_ISSUE_DT":"05/16/2012","DOCKET_NO":"KENT 2012-1365","DECISION_DT":"05/24/2013","CFR_STANDARD_CODE":"75.523-3(c)(2)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-05-16"},{"SOURCE_ROW_NUMBER":"85707","CITATION_NO":"8273926","CITATION_ISSUE_DT":"05/09/2012","DOCKET_NO":"KENT 2012-1365","DECISION_DT":"05/24/2013","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"1038.00","sourceDate":"2012-05-09"},{"SOURCE_ROW_NUMBER":"258788","CITATION_NO":"8265686","CITATION_ISSUE_DT":"01/09/2012","DOCKET_NO":"KENT 2012-733","DECISION_DT":"08/21/2013","CFR_STANDARD_CODE":"75.907","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-01-09"},{"SOURCE_ROW_NUMBER":"26892","CITATION_NO":"8265609","CITATION_ISSUE_DT":"10/19/2011","DOCKET_NO":"KENT 2012-376","DECISION_DT":"08/21/2013","CFR_STANDARD_CODE":"75.1713-7(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"365885","CITATION_NO":"8265603","CITATION_ISSUE_DT":"10/11/2011","DOCKET_NO":"KENT 2012-376","DECISION_DT":"08/21/2013","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"499.00","sourceDate":"2011-10-11"},{"SOURCE_ROW_NUMBER":"423461","CITATION_NO":"8265601","CITATION_ISSUE_DT":"10/04/2011","DOCKET_NO":"KENT 2012-376","DECISION_DT":"08/21/2013","CFR_STANDARD_CODE":"75.1502","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"811.00","sourceDate":"2011-10-04"},{"SOURCE_ROW_NUMBER":"27108","CITATION_NO":"8265540","CITATION_ISSUE_DT":"09/07/2011","DOCKET_NO":"KENT 2012-247","DECISION_DT":"08/21/2013","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"400.00","sourceDate":"2011-09-07"},{"SOURCE_ROW_NUMBER":"251748","CITATION_NO":"8260372","CITATION_ISSUE_DT":"08/30/2011","DOCKET_NO":"KENT 2012-247","DECISION_DT":"08/21/2013","CFR_STANDARD_CODE":"75.364(h)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"26975","CITATION_NO":"8260351","CITATION_ISSUE_DT":"08/17/2011","DOCKET_NO":"KENT 2012-376","DECISION_DT":"08/21/2013","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2011-08-17"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1039,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":10,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":201,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":9,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1995-03-01","lastDate":"2011-06-01","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":776,"firstDate":"2000-01-07","lastDate":"2013-09-25","metrics":{"inspectors":1182,"recentRows":0,"onSiteHours":22129.75,"inspectionHours":33138.5,"inspectionSamples":1703},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1029215","EVENT_NO":"4199521","INSPECTION_BEGIN_DT":"09/25/2013","INSPECTION_END_DT":"09/30/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20.25","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2013-09-25"},{"SOURCE_ROW_NUMBER":"791062","EVENT_NO":"4204107","INSPECTION_BEGIN_DT":"06/10/2013","INSPECTION_END_DT":"06/10/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2013-06-10"},{"SOURCE_ROW_NUMBER":"509964","EVENT_NO":"4203591","INSPECTION_BEGIN_DT":"06/03/2013","INSPECTION_END_DT":"06/05/2013","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"33","SUM_TOTAL_ON_SITE_HOURS":"21","sourceDate":"2013-06-03"},{"SOURCE_ROW_NUMBER":"444872","EVENT_NO":"6372139","INSPECTION_BEGIN_DT":"01/23/2013","INSPECTION_END_DT":"01/23/2013","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2013-01-23"},{"SOURCE_ROW_NUMBER":"137464","EVENT_NO":"4199559","INSPECTION_BEGIN_DT":"01/14/2013","INSPECTION_END_DT":"01/14/2013","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2013-01-14"},{"SOURCE_ROW_NUMBER":"275238","EVENT_NO":"4203960","INSPECTION_BEGIN_DT":"01/08/2013","INSPECTION_END_DT":"01/08/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2013-01-08"},{"SOURCE_ROW_NUMBER":"188285","EVENT_NO":"4199551","INSPECTION_BEGIN_DT":"12/04/2012","INSPECTION_END_DT":"12/04/2012","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2012-12-04"},{"SOURCE_ROW_NUMBER":"208570","EVENT_NO":"4197750","INSPECTION_BEGIN_DT":"11/19/2012","INSPECTION_END_DT":"11/19/2012","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.75","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"888723","EVENT_NO":"4197748","INSPECTION_BEGIN_DT":"11/14/2012","INSPECTION_END_DT":"11/14/2012","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2012-11-14"},{"SOURCE_ROW_NUMBER":"774091","EVENT_NO":"4197747","INSPECTION_BEGIN_DT":"10/30/2012","INSPECTION_END_DT":"10/30/2012","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2012-10-30"},{"SOURCE_ROW_NUMBER":"29033","EVENT_NO":"4198599","INSPECTION_BEGIN_DT":"10/04/2012","INSPECTION_END_DT":"10/04/2012","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2012-10-04"},{"SOURCE_ROW_NUMBER":"966569","EVENT_NO":"4198597","INSPECTION_BEGIN_DT":"10/02/2012","INSPECTION_END_DT":"12/12/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"140.75","SUM_TOTAL_ON_SITE_HOURS":"96.75","sourceDate":"2012-10-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":160,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013-Q3":{"hours":0,"employees":0,"production":0},"2013-Q2":{"hours":0,"employees":0,"production":0},"2013-Q1":{"hours":14830,"employees":27,"production":0},"2012-Q4":{"hours":15414,"employees":38,"production":0},"2012-Q3":{"hours":10949,"employees":26,"production":0},"2012-Q2":{"hours":54489,"employees":134,"production":133611},"2012-Q1":{"hours":59687,"employees":136,"production":149872},"2011-Q4":{"hours":55899,"employees":87,"production":124245},"2011-Q3":{"hours":58739,"employees":116,"production":137033},"2011-Q2":{"hours":63793,"employees":100,"production":175489},"2011-Q1":{"hours":67020,"employees":100,"production":161869},"2010-Q4":{"hours":53805,"employees":86,"production":100536}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":35,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":439605,"employees":153,"production":2217020},"2005":{"hours":414480,"employees":167,"production":2099392},"2006":{"hours":386579,"employees":148,"production":1315043},"2007":{"hours":294228,"employees":118,"production":715893},"2008":{"hours":327323,"employees":129,"production":1027460},"2009":{"hours":254779,"employees":106,"production":668973},"2010":{"hours":222525,"employees":87,"production":605866},"2011":{"hours":245451,"employees":102,"production":598636},"2012":{"hours":140539,"employees":86,"production":283483},"2013":{"hours":14830,"employees":27,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":249,"firstDate":"2000-01-10","lastDate":"2012-02-08","metrics":{"recentRows":0,"doseOver100":101,"actDoseTotal":43764,"pelDoseTotal":39045},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"61664","EVENT_NO":"4197891","SURVEY_DATE":"02/08/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"62","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"61663","EVENT_NO":"4197891","SURVEY_DATE":"02/08/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"36","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"61662","EVENT_NO":"4197891","SURVEY_DATE":"02/08/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"100","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"61661","EVENT_NO":"4197891","SURVEY_DATE":"02/08/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"61","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"61660","EVENT_NO":"4197891","SURVEY_DATE":"02/08/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"63","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"61659","EVENT_NO":"4197891","SURVEY_DATE":"02/08/2012","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"71","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"61658","EVENT_NO":"4197891","SURVEY_DATE":"02/08/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"121","PEL_DOSE_90":"108","SURVEY_TYPE":"I","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"61657","EVENT_NO":"4197891","SURVEY_DATE":"01/19/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"47","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2012-01-19"},{"SOURCE_ROW_NUMBER":"61656","EVENT_NO":"4197891","SURVEY_DATE":"01/19/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"50","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2012-01-19"},{"SOURCE_ROW_NUMBER":"61655","EVENT_NO":"4197891","SURVEY_DATE":"01/19/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"44","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2012-01-19"},{"SOURCE_ROW_NUMBER":"61654","EVENT_NO":"4197891","SURVEY_DATE":"01/19/2012","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"56","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2012-01-19"},{"SOURCE_ROW_NUMBER":"61653","EVENT_NO":"4197891","SURVEY_DATE":"01/19/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"100","PEL_DOSE_90":"87","SURVEY_TYPE":"I","sourceDate":"2012-01-19"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":243,"firstDate":"2000-01-10","lastDate":"2012-04-25","metrics":{"recentRows":0,"voidSamples":17,"maxQuartzPct":28.4,"validSamples":226,"quartzPctTotal":1349.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"32395","CASSETTE_NO":"57978532","SAMPLE_DT":"04/25/2012","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-04-25"},{"SOURCE_ROW_NUMBER":"120163","CASSETTE_NO":"57942664","SAMPLE_DT":"02/08/2012","QUARTZ_PCT":"03.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"82593","CASSETTE_NO":"57942506","SAMPLE_DT":"12/12/2011","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"29752","CASSETTE_NO":"51137646","SAMPLE_DT":"11/15/2011","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-11-15"},{"SOURCE_ROW_NUMBER":"167287","CASSETTE_NO":"57889819","SAMPLE_DT":"10/27/2011","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"16614","CASSETTE_NO":"57889797","SAMPLE_DT":"10/27/2011","QUARTZ_PCT":"03.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"159079","CASSETTE_NO":"57890032","SAMPLE_DT":"08/15/2011","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-15"},{"SOURCE_ROW_NUMBER":"20949","CASSETTE_NO":"57914191","SAMPLE_DT":"07/25/2011","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-07-25"},{"SOURCE_ROW_NUMBER":"127592","CASSETTE_NO":"57908060","SAMPLE_DT":"04/04/2011","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-04-04"},{"SOURCE_ROW_NUMBER":"52551","CASSETTE_NO":"57907831","SAMPLE_DT":"03/10/2011","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-10"},{"SOURCE_ROW_NUMBER":"133916","CASSETTE_NO":"57907662","SAMPLE_DT":"03/03/2011","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-03"},{"SOURCE_ROW_NUMBER":"82733","CASSETTE_NO":"51094675","SAMPLE_DT":"02/10/2011","QUARTZ_PCT":"03.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-02-10"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":4861,"firstDate":"2000-01-07","lastDate":"2013-09-25","metrics":{"ss":1771,"amountDue":3822525.9,"contested":967,"amountPaid":3816376.9,"recentRows":0,"section104d":65,"unterminated":38,"proposedPenalty":4980458},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"905372","VIOLATION_NO":"8278188","VIOLATION_ISSUE_DT":"09/25/2013","SIG_SUB":"Y","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/30/2013","PROPOSED_PENALTY":"1657","AMOUNT_DUE":"1657","AMOUNT_PAID":"1657","CONTESTED_IND":"N","sourceDate":"2013-09-25"},{"SOURCE_ROW_NUMBER":"905987","VIOLATION_NO":"8273468","VIOLATION_ISSUE_DT":"12/05/2012","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/06/2012","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"N","sourceDate":"2012-12-05"},{"SOURCE_ROW_NUMBER":"905363","VIOLATION_NO":"8232839","VIOLATION_ISSUE_DT":"09/17/2012","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/19/2012","PROPOSED_PENALTY":"634","AMOUNT_DUE":"634","AMOUNT_PAID":"634","CONTESTED_IND":"N","sourceDate":"2012-09-17"},{"SOURCE_ROW_NUMBER":"905362","VIOLATION_NO":"8232838","VIOLATION_ISSUE_DT":"09/17/2012","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"07/02/2013","CONTESTED_IND":"N","sourceDate":"2012-09-17"},{"SOURCE_ROW_NUMBER":"904220","VIOLATION_NO":"8273982","VIOLATION_ISSUE_DT":"08/28/2012","SIG_SUB":"N","PART_SECTION":"75.523-3(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/30/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-08-28"},{"SOURCE_ROW_NUMBER":"904219","VIOLATION_NO":"8273981","VIOLATION_ISSUE_DT":"08/28/2012","SIG_SUB":"N","PART_SECTION":"75.1910(l)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/28/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-08-28"},{"SOURCE_ROW_NUMBER":"904218","VIOLATION_NO":"8273979","VIOLATION_ISSUE_DT":"08/27/2012","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/27/2012","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2012-08-27"},{"SOURCE_ROW_NUMBER":"905321","VIOLATION_NO":"8273978","VIOLATION_ISSUE_DT":"08/23/2012","SIG_SUB":"N","PART_SECTION":"75.320(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/23/2012","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"N","sourceDate":"2012-08-23"},{"SOURCE_ROW_NUMBER":"904217","VIOLATION_NO":"8273975","VIOLATION_ISSUE_DT":"08/15/2012","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/16/2012","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"585","CONTESTED_IND":"N","sourceDate":"2012-08-15"},{"SOURCE_ROW_NUMBER":"904216","VIOLATION_NO":"8273974","VIOLATION_ISSUE_DT":"08/15/2012","SIG_SUB":"N","PART_SECTION":"75.1714-3(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/15/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-08-15"},{"SOURCE_ROW_NUMBER":"904215","VIOLATION_NO":"8273973","VIOLATION_ISSUE_DT":"08/14/2012","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/28/2012","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"904214","VIOLATION_NO":"8273969","VIOLATION_ISSUE_DT":"08/09/2012","SIG_SUB":"N","PART_SECTION":"75.337(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/16/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-08-09"}]}],"safety":{"href":"/api/v1/mines/1517651/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517651/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1910","heading":"Nonpermissible diesel-powered equipment; electrical system design and performance requirements.","id":"75.1910","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1910","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"Electrical circuits and components associated with or connected to electrical systems on nonpermissible diesel-powered equipment utilizing storage batteries and integral charging systems, except for the special category of equipment under § 75.1908(d), must conform to the following requirements:\n\n(a) Overload and short circuit protection must be provided for electric circuits and components in accordance with §§ 75.518 and 75.518-1 of this part;\n\n(b) Each electric conductor from the battery to the starting motor must be protected against short circuit by fuses or other circuit-interrupting devices placed as near as practicable to the battery terminals;\n\n(c) Each branch circuit conductor connected to the main circuit between the battery and charging generator must be protected against short circuit by fuses or other automatic circuit-interrupting devices;\n\n(d) The electrical system shall be equipped with a circuit-interrupting device by means of which all power conductors can be deenergized. The device must be located as close as practicable to the battery terminals and be designed to operate within its electrical rating without damage. The device shall not automatically reset after being actuated. All magnetic circuit-interrupting devices must be mounted in a manner to preclude their closing by force of gravity;\n\n(e) Each motor and charging generator must be protected by an automatic overcurrent device. One protective device will be acceptable when two motors of the same rating operate simultaneously and perform virtually the same duty;\n\n(f) Each ungrounded conductor must have insulation compatible with the impressed voltage. Insulation materials must be resistant to deterioration from engine heat and oil. Electric conductors must meet the applicable requirements of §§ 75.513 and 75.513-1, except electric conductors for starting motors, which must only meet the requirements of § 75.513;\n\n(g) All wiring must have adequate mechanical protection to prevent damage to the cable that might result in short circuits;\n\n(h) Sharp edges and corners must be removed at all points where there is a possibility of damaging wires, cables, or conduits by cutting or abrasion. The insulation of the cables within a battery box must be protected against abrasion;\n\n(i) When insulated wires other than cables pass through metal frames, the holes must be substantially bushed with insulated bushings. Cables must enter metal frames of motors, splice boxes, and electric components only through proper fittings. All electrical connections and splices must be mechanically and electrically efficient, and suitable connectors shall be used. All electrical connectors or splices in insulated wire must be reinsulated at least to the same degree of protection as the remainder of the wire;\n\n(j) The battery must be secured to prevent movement, and must be protected from external damage by position. Batteries that are not protected from external damage by position must be enclosed in a battery box. Flame-resistant insulation treated to resist chemical reaction to electrolyte must be provided on battery connections to prevent battery terminals from contacting conducting surfaces;\n\n(k) A battery box, including the cover, must be constructed of steel with a minimum thickness of 1/8 inch, or of a material other than steel that provides equivalent strength;\n\n(l) Battery-box covers must be lined with a flame-resistant insulating material permanently attached to the underside of the cover, unless equivalent protection is provided. Battery-box covers must be provided with a means for securing them in closed position. At least 1/2 inch of air space must be provided between the underside of the cover and the top of the battery, including terminals;\n\n(m) Battery boxes must be provided with ventilation openings to prevent the accumulation of flammable or toxic gases or vapors within the battery box. The size and locations of openings for ventilation must prevent direct access to battery terminals;\n\n(n) The battery must be insulated from the battery-box walls and supported on insulating materials. Insulating materials that may be subject to chemical reaction with electrolyte must be treated to resist such action; and\n\n(o) Drainage holes must be provided in the bottom of each battery box.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","heading":"Air quality detectors and measurement devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.320","part":"75","subchapter":"O","subpart":"D","id":"75.320","citation":"30 CFR 75.320","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.337","heading":"Construction and repair of seals.","id":"75.337","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.337","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) The mine operator shall maintain and repair seals to protect miners from hazards of sealed areas.\n\n(b) Prior to sealing, the mine operator shall—\n\n(1) Remove insulated cables, batteries, and other potential electric ignition sources from the area to be sealed when constructing seals, unless it is not safe to do so. If ignition sources cannot safely be removed, seals must be constructed to at least 120 psi;\n\n(2) Remove metallic objects through or across seals; and\n\n(3) Breach or remove all stoppings in the first crosscut inby the seals immediately prior to sealing the area.\n\n(c) A certified person designated by the mine operator shall directly supervise seal construction and repair and—\n\n(1) Examine each seal site immediately prior to construction or repair to ensure that the site is in accordance with the approved ventilation plan;\n\n(2) Examine each seal under construction or repair during each shift to ensure that the seal is being constructed or repaired in accordance with the approved ventilation plan;\n\n(3) Examine each seal upon completion of construction or repair to ensure that construction or repair is in accordance with the approved ventilation plan;\n\n(4) Certify by initials, date, and time that the examinations were made; and\n\n(5) Make a record of the examination at the completion of any shift during which an examination was conducted. The record shall include each deficiency and the corrective action taken. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be kept at the mine for one year.\n\n(d) Upon completion of construction of each seal a senior mine management official, such as a mine manager or superintendent, shall certify that the construction, installation, and materials used were in accordance with the approved ventilation plan. The mine operator shall retain the certification for as long as the seal is needed to serve the purpose for which it was built.\n\n(e) The mine operator shall—\n\n(1) Notify the District Manager between two and fourteen days prior to commencement of seal construction;\n\n(2) Notify the District Manager, in writing, within five days of completion of a set of seals and provide a copy of the certification required in paragraph (d) of this section; and\n\n(3) Submit a copy of quality control results to the District Manager for seal material properties specified by § 75.335 within 30 days of completion of quality control tests.\n\n(f) Welding, cutting, and soldering. Welding, cutting, and soldering with an arc or flame are prohibited within 150 feet of a seal. An operator may request a different location in the ventilation plan to be approved by the District Manager. The operator's request must address methods the mine operator will use to continuously monitor atmospheric conditions in the sealed area during welding or burning; the airflow conditions in and around the work area; the rock dust and water application methods; the availability of fire extinguishers on hand; the procedures to maintain safe conditions, and other relevant factors.\n\n(g) Sampling pipes. (1) For seals constructed after April 18, 2008, one non-metallic sampling pipe shall be installed in each seal that shall extend into the center of the first connecting crosscut inby the seal. If an open crosscut does not exist, the sampling pipe shall extend one-half of the distance of the open entry inby the seal.\n\n(2) Each sampling pipe shall be equipped with a shut-off valve and appropriate fittings for taking gas samples.\n\n(3) The sampling pipes shall be labeled to indicate the location of the sampling point when more than one sampling pipe is installed through a seal.\n\n(4) If a new seal is constructed to replace or reinforce an existing seal with a sampling pipe, the sampling pipe in the existing seal shall extend through the new seal. An additional sampling pipe shall be installed through each new seal to sample the area between seals, as specified in the approved ventilation plan.\n\n(h) Water drainage system. For each set of seals constructed after April 18, 2008, the seal at the lowest elevation shall have a corrosion-resistant, non-metallic water drainage system. Seals shall not impound water or slurry. Water or slurry shall not accumulate within the sealed area to any depth that can adversely affect a seal.\n\n[73 FR 21207, Apr. 18, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517651","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}