{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1517507","name":"Deanefield","status":"Abandoned","status_date":"2002-07-02","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Ohio","nearest_town":"Reynolds Station","operator_id":"P22829","operator_name":"United Minerals Co LLC","controller_id":"C15833","controller_name":"Peabody Energy Corporation","district":"C10","office":"Madisonville KY Field Office","employees":0,"latitude":37.686111,"longitude":-86.801388},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":474},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517507","name":"Deanefield"},"operator":{"type":"operator","id":"P22829","name":"United Minerals Co LLC"},"controller":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C10966","name":"Rickey S  Winn"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"1984-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|C10966|1984-02-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14485","name":"Anthony V  Lanham"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"1991-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|C14485|1991-08-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C10330","name":"Danny  Jasper"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"1993-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|C10330|1993-03-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21637","name":"Lanham Mining Company Inc"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"1994-02-01","validTo":"1994-06-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P21637|1994-02-01|1994-06-19"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14485","name":"Anthony V  Lanham"},"object":{"type":"operator","id":"P21637","name":"Lanham Mining Company Inc"},"validFrom":"1994-02-01","validTo":"1994-06-19","current":false,"derived":true,"evidenceMineId":"1517507","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P21637|1994-02-01|C14485|1991-08-01|93004"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15089","name":"Peabody Energy et al"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"1994-06-01","validTo":"2015-12-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|C15089|1994-06-01|2015-12-30"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P15213","name":"Rickey S Winn Construction"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"1994-06-20","validTo":"1996-03-24","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P15213|1994-06-20|1996-03-24"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C10966","name":"Rickey S  Winn"},"object":{"type":"operator","id":"P15213","name":"Rickey S Winn Construction"},"validFrom":"1994-06-20","validTo":"1996-03-24","current":false,"derived":true,"evidenceMineId":"1517507","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P15213|1994-06-20|C10966|1984-02-01|83224"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21637","name":"Lanham Mining Company Inc"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"1996-03-25","validTo":"1999-06-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P21637|1996-03-25|1999-06-21"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14485","name":"Anthony V  Lanham"},"object":{"type":"operator","id":"P21637","name":"Lanham Mining Company Inc"},"validFrom":"1996-03-25","validTo":"1999-06-21","current":false,"derived":true,"evidenceMineId":"1517507","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P21637|1996-03-25|C14485|1991-08-01|93005"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22303","name":"Danny Jasper Inc"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"1999-06-22","validTo":"2002-04-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P22303|1999-06-22|2002-04-21"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C10330","name":"Danny  Jasper"},"object":{"type":"operator","id":"P22303","name":"Danny Jasper Inc"},"validFrom":"1999-06-22","validTo":"2002-04-21","current":false,"derived":true,"evidenceMineId":"1517507","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P22303|1999-06-22|C10330|1993-03-01|81771"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22829","name":"United Minerals Co LLC"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"2002-04-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P22829|2002-04-22|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15089","name":"Peabody Energy et al"},"object":{"type":"operator","id":"P22829","name":"United Minerals Co LLC"},"validFrom":"2002-04-22","validTo":"2015-12-30","current":false,"derived":true,"evidenceMineId":"1517507","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P22829|2002-04-22|C15089|1994-06-01|94727"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15089","name":"United Minerals Inc et al"},"object":{"type":"operator","id":"P22829","name":"United Minerals Co LLC"},"validFrom":"2002-04-22","validTo":"2015-12-30","current":false,"derived":true,"evidenceMineId":"1517507","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P22829|2002-04-22|C15089|1994-06-01|94728"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"1517507","name":"Deanefield"},"validFrom":"2015-12-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|C15833|2015-12-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P22829","name":"United Minerals Co LLC"},"validFrom":"2015-12-31","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517507","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517507|P22829|2002-04-22|C15833|2015-12-31|97037"}}],"coverage":{"historyRecords":7,"edgeCount":17,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":8,"firstDate":"2000-02-24","lastDate":"2002-02-23","metrics":{"daysLost":93,"injuries":8,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"186326","DOCUMENT_NO":"220020640008","ACCIDENT_DT":"02/23/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"EE WAS CLEANING MUD FROM A BATTERY BOX WITH A SHORT METAL BAR. THE BAR SLIPPED AND CAUGHT HIS THUMB BETWEEN BAR AND BULLDOZER.","sourceDate":"2002-02-23"},{"SOURCE_ROW_NUMBER":"207828","DOCUMENT_NO":"220020640009","ACCIDENT_DT":"02/21/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"OPERATOR WAS CLIMBING ONTO A DOZER. WHEN HIS FOOT SLIPPED ONT HE LADDER DUE TO MUDDY. WET CONDITIONS AS A RESULT HE HIT HIS RIB CAGE.","sourceDate":"2002-02-21"},{"SOURCE_ROW_NUMBER":"246603","DOCUMENT_NO":"220012540036","ACCIDENT_DT":"08/22/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"DOING MECHANICAL REPAIRS ON BULLDOZER. RUBBED ARM ACROSS EYES. GOT FOREIGN OBJECT IN LEFT EYE.","sourceDate":"2001-08-22"},{"SOURCE_ROW_NUMBER":"78787","DOCUMENT_NO":"220010780024","ACCIDENT_DT":"03/08/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","NARRATIVE":"WHILE CHANGING AN AIR HOSE ON A MOTORIZED OIL PUMP, THE TOP OF THE AIR MOTOR MOVED AND CAUGHT EE'S FINGER CAUSING A CUT AND BREAK OF THE FINGER.","sourceDate":"2001-03-08"},{"SOURCE_ROW_NUMBER":"31500","DOCUMENT_NO":"220010160087","ACCIDENT_DT":"01/07/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","NARRATIVE":"OPERATOR WAS GETTING OUT OF THE DOZER. HE STEPPED ONTO THE DOZER TRACK WHICH WAS WET. HE SLIPPED& HIT HIS HEAD ON THE BLADE LIFT CYLINDER, CUTTING HIS HEAD WHICH REQUIRED SUTURES.","sourceDate":"2001-01-07"},{"SOURCE_ROW_NUMBER":"173397","DOCUMENT_NO":"220002720021","ACCIDENT_DT":"09/08/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Coal/ore shovel operator,  Shoveler,  Power shoveler","NO_INJURIES":"1","DAYS_LOST":"89","NARRATIVE":"OPERATOR WAS SCRAPING DIRT OFF THE TOP OF THE COAL WITH THE FRT BUCKET OF THE TRACKHOE WHEN THE BUCKET HIT AN OLD OIL WELL CASING PIPE 9\"-6\" IN DIAMENTER. WHEN HE HIT THE CASING IT CAUSED A BI JOLT THAT CAUSED WHIPLASH TO HIS NECK. HE DID NOT EXPERIENCE PAIN UNTIL A FEW DAYS LATER","sourceDate":"2000-09-08"},{"SOURCE_ROW_NUMBER":"134565","DOCUMENT_NO":"220001120071","ACCIDENT_DT":"03/31/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"USING HAMMER AND CHISEL TO REMOVE A BROKEN BOLT, A TINY PIECE OF METAL GOT IN RIGHT EYE. HE THOUGHT IT WAS DIRT BUT BY 4-2-00 IT WAS SWOLLEN SHUT.","sourceDate":"2000-03-31"},{"SOURCE_ROW_NUMBER":"143306","DOCUMENT_NO":"220000730058","ACCIDENT_DT":"02/24/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","NARRATIVE":"WHILE LOADING EXPLOSIVES INTO DRILL HOLES WITH A BULK TRUCK, HE TWISTED HIS RIGHT KNEE CLIMBING IN AND OUT OF TRUCK.","sourceDate":"2000-02-24"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-07-02","lastDate":"2002-07-02","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":48,"firstDate":"2000-05-03","lastDate":"2002-06-12","metrics":{"ss":11,"delinquent":48,"recentRows":0,"paidPenalty":3426,"proposedPenalty":3426,"currentAssessment":3426},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1252761","VIOLATION_NO":"7650870","ISSUE_DT":"06/12/2002","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-12"},{"SOURCE_ROW_NUMBER":"1252755","VIOLATION_NO":"4062444","ISSUE_DT":"06/04/2002","CFR_STANDARD_CD":"48.26(b)(7)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"188.00","CURRENT_ASSESSMENT_AMT":"188.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-04"},{"SOURCE_ROW_NUMBER":"1252760","VIOLATION_NO":"7650858","ISSUE_DT":"05/01/2002","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"90.00","CURRENT_ASSESSMENT_AMT":"90.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-01"},{"SOURCE_ROW_NUMBER":"1252759","VIOLATION_NO":"7650857","ISSUE_DT":"04/25/2002","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"90.00","CURRENT_ASSESSMENT_AMT":"90.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-25"},{"SOURCE_ROW_NUMBER":"1252758","VIOLATION_NO":"7650856","ISSUE_DT":"04/25/2002","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"90.00","CURRENT_ASSESSMENT_AMT":"90.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-25"},{"SOURCE_ROW_NUMBER":"1252757","VIOLATION_NO":"7650855","ISSUE_DT":"04/25/2002","CFR_STANDARD_CD":"77.1109(e)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-25"},{"SOURCE_ROW_NUMBER":"1252756","VIOLATION_NO":"7650854","ISSUE_DT":"04/15/2002","CFR_STANDARD_CD":"71.403(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-15"},{"SOURCE_ROW_NUMBER":"1258658","VIOLATION_NO":"7644079","ISSUE_DT":"12/06/2001","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-06"},{"SOURCE_ROW_NUMBER":"1258657","VIOLATION_NO":"7644077","ISSUE_DT":"11/08/2001","CFR_STANDARD_CD":"77.206(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-08"},{"SOURCE_ROW_NUMBER":"1258656","VIOLATION_NO":"7644076","ISSUE_DT":"11/08/2001","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-08"},{"SOURCE_ROW_NUMBER":"1258655","VIOLATION_NO":"7644075","ISSUE_DT":"11/08/2001","CFR_STANDARD_CD":"77.410(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-08"},{"SOURCE_ROW_NUMBER":"1258654","VIOLATION_NO":"7644074","ISSUE_DT":"11/08/2001","CFR_STANDARD_CD":"77.410(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-08"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":44,"firstDate":"2000-01-11","lastDate":"2002-03-23","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":43,"maxConcentration":2.544,"concentrationTotal":32.262},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"508303","CASS_NUM":"50604320","SMP_TAKEN_DT":"3/23/2002","CONC":".461","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-23"},{"SOURCE_ROW_NUMBER":"1362834","CASS_NUM":"57372601","SMP_TAKEN_DT":"2/12/2002","CONC":"1.851","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"641903","CASS_NUM":"57372511","SMP_TAKEN_DT":"2/12/2002","CONC":".939","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"606210","CASS_NUM":"57372552","SMP_TAKEN_DT":"2/12/2002","CONC":".305","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"249976","CASS_NUM":"57372637","SMP_TAKEN_DT":"2/12/2002","CONC":".477","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"181993","CASS_NUM":"57372635","SMP_TAKEN_DT":"2/12/2002","CONC":".118","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"633151","CASS_NUM":"50604316","SMP_TAKEN_DT":"1/29/2002","CONC":".483","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-29"},{"SOURCE_ROW_NUMBER":"1116105","CASS_NUM":"50604303","SMP_TAKEN_DT":"10/19/2001","CONC":".462","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-10-19"},{"SOURCE_ROW_NUMBER":"1071491","CASS_NUM":"50604310","SMP_TAKEN_DT":"9/26/2001","CONC":".882","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-09-26"},{"SOURCE_ROW_NUMBER":"553375","CASS_NUM":"50604306","SMP_TAKEN_DT":"9/26/2001","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCRAPPER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-09-26"},{"SOURCE_ROW_NUMBER":"1621741","CASS_NUM":"50604307","SMP_TAKEN_DT":"7/20/2001","CONC":"1.285","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCRAPPER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-07-20"},{"SOURCE_ROW_NUMBER":"878673","CASS_NUM":"50604327","SMP_TAKEN_DT":"7/13/2001","CONC":"1.27","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-07-13"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":227,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":52,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":7,"firstDate":"1994-02-01","lastDate":"2002-04-22","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":18,"firstDate":"2000-01-10","lastDate":"2002-04-04","metrics":{"inspectors":24,"recentRows":0,"onSiteHours":399.75,"inspectionHours":710.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"700771","EVENT_NO":"4279699","INSPECTION_BEGIN_DT":"04/04/2002","INSPECTION_END_DT":"07/02/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"76","SUM_TOTAL_ON_SITE_HOURS":"43.5","sourceDate":"2002-04-04"},{"SOURCE_ROW_NUMBER":"827636","EVENT_NO":"4281935","INSPECTION_BEGIN_DT":"03/22/2002","INSPECTION_END_DT":"03/22/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2002-03-22"},{"SOURCE_ROW_NUMBER":"776541","EVENT_NO":"4283032","INSPECTION_BEGIN_DT":"02/12/2002","INSPECTION_END_DT":"02/25/2002","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15.75","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"33686","EVENT_NO":"4283031","INSPECTION_BEGIN_DT":"02/11/2002","INSPECTION_END_DT":"02/11/2002","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2002-02-11"},{"SOURCE_ROW_NUMBER":"1064208","EVENT_NO":"4281848","INSPECTION_BEGIN_DT":"10/03/2001","INSPECTION_END_DT":"03/08/2002","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2001-10-03"},{"SOURCE_ROW_NUMBER":"54551","EVENT_NO":"4281847","INSPECTION_BEGIN_DT":"10/03/2001","INSPECTION_END_DT":"03/08/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"74","SUM_TOTAL_ON_SITE_HOURS":"47","sourceDate":"2001-10-03"},{"SOURCE_ROW_NUMBER":"79271","EVENT_NO":"4281045","INSPECTION_BEGIN_DT":"08/15/2001","INSPECTION_END_DT":"08/16/2001","ACTIVITY_CODE":"CBA","ACTIVITY":"ELECTRICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2001-08-15"},{"SOURCE_ROW_NUMBER":"32008","EVENT_NO":"4282493","INSPECTION_BEGIN_DT":"07/02/2001","INSPECTION_END_DT":"07/02/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2001-07-02"},{"SOURCE_ROW_NUMBER":"780381","EVENT_NO":"4282388","INSPECTION_BEGIN_DT":"05/31/2001","INSPECTION_END_DT":"06/04/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2001-05-31"},{"SOURCE_ROW_NUMBER":"1129403","EVENT_NO":"4281917","INSPECTION_BEGIN_DT":"04/02/2001","INSPECTION_END_DT":"09/25/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"96","SUM_TOTAL_ON_SITE_HOURS":"51.5","sourceDate":"2001-04-02"},{"SOURCE_ROW_NUMBER":"854388","EVENT_NO":"4282376","INSPECTION_BEGIN_DT":"03/26/2001","INSPECTION_END_DT":"06/12/2001","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"17","sourceDate":"2001-03-26"},{"SOURCE_ROW_NUMBER":"1105215","EVENT_NO":"4279644","INSPECTION_BEGIN_DT":"10/03/2000","INSPECTION_END_DT":"03/19/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"171","SUM_TOTAL_ON_SITE_HOURS":"95.5","sourceDate":"2000-10-03"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":11,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q3":{"hours":0,"employees":0,"production":0},"2002-Q2":{"hours":743,"employees":3,"production":4222},"2002-Q1":{"hours":4095,"employees":7,"production":10682},"2001-Q4":{"hours":5265,"employees":9,"production":18273},"2001-Q3":{"hours":5265,"employees":9,"production":25543},"2001-Q2":{"hours":8294,"employees":11,"production":35120},"2001-Q1":{"hours":8940,"employees":13,"production":27473},"2000-Q4":{"hours":10010,"employees":14,"production":43938},"2000-Q3":{"hours":9162,"employees":13,"production":35416},"2000-Q2":{"hours":9464,"employees":13,"production":38854},"2000-Q1":{"hours":10192,"employees":14,"production":35738}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":38828,"employees":14,"production":153946},"2001":{"hours":27764,"employees":11,"production":106409},"2002":{"hours":4838,"employees":5,"production":14904}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":6,"firstDate":"2001-07-02","lastDate":"2002-02-11","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":419,"pelDoseTotal":230},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"60677","EVENT_NO":"4283031","SURVEY_DATE":"02/11/2002","OCCUPATION_CD_DESC":"MECHANIC HELPER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"36","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2002-02-11"},{"SOURCE_ROW_NUMBER":"60676","EVENT_NO":"4283031","SURVEY_DATE":"02/11/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"19","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2002-02-11"},{"SOURCE_ROW_NUMBER":"60675","EVENT_NO":"4283031","SURVEY_DATE":"02/11/2002","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"93","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2002-02-11"},{"SOURCE_ROW_NUMBER":"60674","EVENT_NO":"4283031","SURVEY_DATE":"02/11/2002","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"118","ACT_DOSE_85":"100","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2002-02-11"},{"SOURCE_ROW_NUMBER":"60673","EVENT_NO":"4283031","SURVEY_DATE":"02/11/2002","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"101","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2002-02-11"},{"SOURCE_ROW_NUMBER":"60672","EVENT_NO":"4282493","SURVEY_DATE":"07/02/2001","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"70","PEL_DOSE_90":"53","SURVEY_TYPE":"F","sourceDate":"2001-07-02"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":48,"firstDate":"2000-05-03","lastDate":"2002-06-12","metrics":{"ss":11,"amountDue":3426,"contested":0,"amountPaid":3426,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":3426},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"894761","VIOLATION_NO":"7650870","VIOLATION_ISSUE_DT":"06/12/2002","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/14/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-06-12"},{"SOURCE_ROW_NUMBER":"894755","VIOLATION_NO":"4062444","VIOLATION_ISSUE_DT":"06/04/2002","SIG_SUB":"Y","PART_SECTION":"48.26(b)(7)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"06/04/2002","PROPOSED_PENALTY":"188","AMOUNT_DUE":"188","AMOUNT_PAID":"188","CONTESTED_IND":"N","sourceDate":"2002-06-04"},{"SOURCE_ROW_NUMBER":"894760","VIOLATION_NO":"7650858","VIOLATION_ISSUE_DT":"05/01/2002","SIG_SUB":"Y","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/07/2002","PROPOSED_PENALTY":"90","AMOUNT_DUE":"90","AMOUNT_PAID":"90","CONTESTED_IND":"N","sourceDate":"2002-05-01"},{"SOURCE_ROW_NUMBER":"894759","VIOLATION_NO":"7650857","VIOLATION_ISSUE_DT":"04/25/2002","SIG_SUB":"Y","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/01/2002","PROPOSED_PENALTY":"90","AMOUNT_DUE":"90","AMOUNT_PAID":"90","CONTESTED_IND":"N","sourceDate":"2002-04-25"},{"SOURCE_ROW_NUMBER":"894758","VIOLATION_NO":"7650856","VIOLATION_ISSUE_DT":"04/25/2002","SIG_SUB":"Y","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/25/2002","PROPOSED_PENALTY":"90","AMOUNT_DUE":"90","AMOUNT_PAID":"90","CONTESTED_IND":"N","sourceDate":"2002-04-25"},{"SOURCE_ROW_NUMBER":"894757","VIOLATION_NO":"7650855","VIOLATION_ISSUE_DT":"04/25/2002","SIG_SUB":"N","PART_SECTION":"77.1109(e)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/25/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-04-25"},{"SOURCE_ROW_NUMBER":"894756","VIOLATION_NO":"7650854","VIOLATION_ISSUE_DT":"04/15/2002","SIG_SUB":"N","PART_SECTION":"71.403(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/12/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-04-15"},{"SOURCE_ROW_NUMBER":"894798","VIOLATION_NO":"7644079","VIOLATION_ISSUE_DT":"12/06/2001","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/21/2001","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2001-12-06"},{"SOURCE_ROW_NUMBER":"894797","VIOLATION_NO":"7644077","VIOLATION_ISSUE_DT":"11/08/2001","SIG_SUB":"N","PART_SECTION":"77.206(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/08/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-08"},{"SOURCE_ROW_NUMBER":"894796","VIOLATION_NO":"7644076","VIOLATION_ISSUE_DT":"11/08/2001","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/16/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-08"},{"SOURCE_ROW_NUMBER":"894795","VIOLATION_NO":"7644075","VIOLATION_ISSUE_DT":"11/08/2001","SIG_SUB":"N","PART_SECTION":"77.410(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/08/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-08"},{"SOURCE_ROW_NUMBER":"894794","VIOLATION_NO":"7644074","VIOLATION_ISSUE_DT":"11/08/2001","SIG_SUB":"N","PART_SECTION":"77.410(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/08/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-08"}]}],"safety":{"href":"/api/v1/mines/1517507/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517507/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","heading":"Experienced miner training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.26","part":"48","subchapter":"H","subpart":"B","id":"48.26","citation":"30 CFR 48.26","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","heading":"Waiver of surface facilities requirements; posting of waiver.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-E/section-71.403","part":"71","subchapter":"O","subpart":"E","id":"71.403","citation":"30 CFR 71.403","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.206","heading":"Ladders; construction; installation and maintenance.","id":"77.206","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.206","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Ladders shall be of substantial construction and maintained in good condition.\n\n(b) Wooden members of ladders shall not be painted.\n\n(c) Steep or vertical ladders which are used regularly at fixed locations shall be anchored securely and provided with backguards extending from a point not more than 7 feet from the bottom of the ladder to the top of the ladder.\n\n(d) Fixed ladders shall not incline backwards at any point unless provided with backguards.\n\n(e) Fixed ladders shall be anchored securely and installed to provide at least 3 inches of toe clearance.\n\n(f) Fixed ladders shall project at least 3 feet above landings, or substantial handholds shall be provided above the landings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517507","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}