{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1517407","name":"No 4","status":"Abandoned and Sealed","status_date":"2004-08-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Floyd","nearest_town":"Honaker","operator_id":"P19090","operator_name":"C & L Coal Company Inc","controller_id":"C00363","controller_name":"Conroy  Coleman","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.491388,"longitude":-82.708611},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":1094},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517407","name":"No 4"},"operator":{"type":"operator","id":"P19090","name":"C & L Coal Company Inc"},"controller":{"type":"controller","id":"C00363","name":"Conroy  Coleman"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00363","name":"Conroy  Coleman  et al"},"object":{"type":"mine","id":"1517407","name":"No 4"},"validFrom":"1987-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517407|C00363|1987-11-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14285","name":"Roger  Hunter"},"object":{"type":"mine","id":"1517407","name":"No 4"},"validFrom":"1990-11-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517407|C14285|1990-11-28|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21237","name":"Hunter Mining Inc"},"object":{"type":"mine","id":"1517407","name":"No 4"},"validFrom":"1993-06-01","validTo":"1994-09-20","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517407|P21237|1993-06-01|1994-09-20"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14285","name":"Roger  Hunter"},"object":{"type":"operator","id":"P21237","name":"Hunter Mining Inc"},"validFrom":"1993-06-01","validTo":"1994-09-20","current":false,"derived":true,"evidenceMineId":"1517407","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517407|P21237|1993-06-01|C14285|1990-11-28|92414"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19090","name":"C & L Coal Company Inc"},"object":{"type":"mine","id":"1517407","name":"No 4"},"validFrom":"1994-09-21","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517407|P19090|1994-09-21|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00363","name":"Conroy  Coleman  et al"},"object":{"type":"operator","id":"P19090","name":"C & L Coal Company Inc"},"validFrom":"1994-09-21","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517407","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517407|P19090|1994-09-21|C00363|1987-11-01|46444"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":10,"firstDate":"2000-02-29","lastDate":"2004-04-22","metrics":{"daysLost":619,"injuries":9,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"91551","DOCUMENT_NO":"220041240019","ACCIDENT_DT":"04/22/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Security guard, Watchman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"OIL OUT OF TRANSFORMER SPILLED ON HIM.","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"173384","DOCUMENT_NO":"220041050035","ACCIDENT_DT":"04/02/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Fell off mantrip.","sourceDate":"2004-04-02"},{"SOURCE_ROW_NUMBER":"216448","DOCUMENT_NO":"220040400040","ACCIDENT_DT":"01/30/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"12","NARRATIVE":"THROWING A CHAIN ACROSS BELT.","sourceDate":"2004-01-30"},{"SOURCE_ROW_NUMBER":"83089","DOCUMENT_NO":"220022590002","ACCIDENT_DT":"09/06/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Coal dump operator","NO_INJURIES":"1","DAYS_LOST":"211","NARRATIVE":"BATTERIES BLEW UP AND LID HIT HIM WHILE WALKING BY","sourceDate":"2002-09-06"},{"SOURCE_ROW_NUMBER":"27230","DOCUMENT_NO":"220020840132","ACCIDENT_DT":"03/15/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"334","NARRATIVE":"STRAINED HIMSELF WHILE LIFTING ROCKDUST.","sourceDate":"2002-03-15"},{"SOURCE_ROW_NUMBER":"138972","DOCUMENT_NO":"220020310008","ACCIDENT_DT":"01/22/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Cutting machine operator, Ripper, Universal operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"CUTTING MACHINE RAN OVER LUMP OF COAL AND HURT BACK.","sourceDate":"2002-01-22"},{"SOURCE_ROW_NUMBER":"125790","DOCUMENT_NO":"220001850136","ACCIDENT_DT":"06/19/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"40","NARRATIVE":"DRIVING A SCOOP, RUN OVER ROCK, THROW UP INTO TOP OF CANOPY.","sourceDate":"2000-06-19"},{"SOURCE_ROW_NUMBER":"130144","DOCUMENT_NO":"220001220040","ACCIDENT_DT":"04/24/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"DRIVING TO FAST DOWN HILL.","sourceDate":"2000-04-24"},{"SOURCE_ROW_NUMBER":"100091","DOCUMENT_NO":"220000870013","ACCIDENT_DT":"03/20/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ELECTRICAL FIRE, OUTSIDE COMPACTOR BANK SHORTED OUT INTERNALY.","sourceDate":"2000-03-20"},{"SOURCE_ROW_NUMBER":"229371","DOCUMENT_NO":"220000730056","ACCIDENT_DT":"02/29/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"9","NARRATIVE":"WORKING ON BELT' RED DEVIL BAR SLIP HIT HIM ON THUMB WAS CUT.","sourceDate":"2000-02-29"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2004-08-16","lastDate":"2004-08-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":262,"firstDate":"2000-01-13","lastDate":"2004-07-08","metrics":{"ss":112,"delinquent":251,"recentRows":0,"paidPenalty":29544,"proposedPenalty":29544,"currentAssessment":29544},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"977305","VIOLATION_NO":"7408868","ISSUE_DT":"07/08/2004","CFR_STANDARD_CD":"75.1711-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"291.00","CURRENT_ASSESSMENT_AMT":"291.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-08"},{"SOURCE_ROW_NUMBER":"977306","VIOLATION_NO":"7408869","ISSUE_DT":"07/07/2004","CFR_STANDARD_CD":"77.208(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-07"},{"SOURCE_ROW_NUMBER":"964653","VIOLATION_NO":"7404210","ISSUE_DT":"05/04/2004","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"203.00","CURRENT_ASSESSMENT_AMT":"203.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"964652","VIOLATION_NO":"7404202","ISSUE_DT":"04/28/2004","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-28"},{"SOURCE_ROW_NUMBER":"964651","VIOLATION_NO":"7404201","ISSUE_DT":"04/28/2004","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-28"},{"SOURCE_ROW_NUMBER":"964650","VIOLATION_NO":"7404200","ISSUE_DT":"04/27/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-27"},{"SOURCE_ROW_NUMBER":"964647","VIOLATION_NO":"4026527","ISSUE_DT":"04/19/2004","CFR_STANDARD_CD":"75.1107-4(a)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"383.00","CURRENT_ASSESSMENT_AMT":"383.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"964649","VIOLATION_NO":"7404191","ISSUE_DT":"04/12/2004","CFR_STANDARD_CD":"75.402","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-12"},{"SOURCE_ROW_NUMBER":"964648","VIOLATION_NO":"7404190","ISSUE_DT":"04/12/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-12"},{"SOURCE_ROW_NUMBER":"977154","VIOLATION_NO":"7404272","ISSUE_DT":"02/24/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"977153","VIOLATION_NO":"7404271","ISSUE_DT":"02/24/2004","CFR_STANDARD_CD":"75.1103-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"977152","VIOLATION_NO":"7404270","ISSUE_DT":"02/24/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"247.00","CURRENT_ASSESSMENT_AMT":"247.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-24"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":360,"firstDate":"2000-01-03","lastDate":"2004-05-05","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":17,"validSamples":343,"maxConcentration":3.352,"concentrationTotal":204.779},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"781185","CASS_NUM":"50740578","SMP_TAKEN_DT":"5/5/2004","CONC":".064","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"CITATION SAMPLE/COMPLIANCE DURING FIRST SEVEN DAYS OF CYCLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-05"},{"SOURCE_ROW_NUMBER":"1358808","CASS_NUM":"57563356","SMP_TAKEN_DT":"5/4/2004","CONC":".653","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"1254662","CASS_NUM":"57563424","SMP_TAKEN_DT":"5/4/2004","CONC":".877","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"1127597","CASS_NUM":"57563396","SMP_TAKEN_DT":"5/4/2004","CONC":".283","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"1107554","CASS_NUM":"57563372","SMP_TAKEN_DT":"5/4/2004","CONC":".562","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"317108","CASS_NUM":"57563388","SMP_TAKEN_DT":"5/4/2004","CONC":".604","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"120737","CASS_NUM":"57563436","SMP_TAKEN_DT":"5/4/2004","CONC":".537","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"959009","CASS_NUM":"50661056","SMP_TAKEN_DT":"5/3/2004","CONC":".07","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-03"},{"SOURCE_ROW_NUMBER":"1368593","CASS_NUM":"57563518","SMP_TAKEN_DT":"3/25/2004","CONC":".91","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-25"},{"SOURCE_ROW_NUMBER":"1035225","CASS_NUM":"57563554","SMP_TAKEN_DT":"3/25/2004","CONC":".22","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-25"},{"SOURCE_ROW_NUMBER":"461783","CASS_NUM":"57563556","SMP_TAKEN_DT":"3/25/2004","CONC":".413","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-25"},{"SOURCE_ROW_NUMBER":"402816","CASS_NUM":"57563535","SMP_TAKEN_DT":"3/25/2004","CONC":".401","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-25"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":5,"firstDate":"2002-12-17","lastDate":"2004-09-01","metrics":{"linkedIssuances":5},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1993-06-01","lastDate":"1994-09-21","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":92,"firstDate":"2000-01-13","lastDate":"2004-07-06","metrics":{"inspectors":115,"recentRows":0,"onSiteHours":1443.75,"inspectionHours":2096.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"834315","EVENT_NO":"4175358","INSPECTION_BEGIN_DT":"07/06/2004","INSPECTION_END_DT":"08/16/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"32","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2004-07-06"},{"SOURCE_ROW_NUMBER":"596904","EVENT_NO":"4183993","INSPECTION_BEGIN_DT":"04/28/2004","INSPECTION_END_DT":"05/04/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2004-04-28"},{"SOURCE_ROW_NUMBER":"490405","EVENT_NO":"4171143","INSPECTION_BEGIN_DT":"04/06/2004","INSPECTION_END_DT":"06/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"68","SUM_TOTAL_ON_SITE_HOURS":"41.5","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"892709","EVENT_NO":"4183975","INSPECTION_BEGIN_DT":"03/22/2004","INSPECTION_END_DT":"03/25/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2004-03-22"},{"SOURCE_ROW_NUMBER":"1090222","EVENT_NO":"4175318","INSPECTION_BEGIN_DT":"03/16/2004","INSPECTION_END_DT":"03/16/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2004-03-16"},{"SOURCE_ROW_NUMBER":"1098479","EVENT_NO":"4175311","INSPECTION_BEGIN_DT":"01/20/2004","INSPECTION_END_DT":"03/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"77","SUM_TOTAL_ON_SITE_HOURS":"60","sourceDate":"2004-01-20"},{"SOURCE_ROW_NUMBER":"1103889","EVENT_NO":"4183738","INSPECTION_BEGIN_DT":"01/05/2004","INSPECTION_END_DT":"01/07/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2004-01-05"},{"SOURCE_ROW_NUMBER":"623102","EVENT_NO":"4175304","INSPECTION_BEGIN_DT":"11/18/2003","INSPECTION_END_DT":"11/18/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2003-11-18"},{"SOURCE_ROW_NUMBER":"25359","EVENT_NO":"4167912","INSPECTION_BEGIN_DT":"10/03/2003","INSPECTION_END_DT":"12/31/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"118.5","SUM_TOTAL_ON_SITE_HOURS":"77.75","sourceDate":"2003-10-03"},{"SOURCE_ROW_NUMBER":"670553","EVENT_NO":"4183709","INSPECTION_BEGIN_DT":"10/01/2003","INSPECTION_END_DT":"10/02/2003","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.25","sourceDate":"2003-10-01"},{"SOURCE_ROW_NUMBER":"245662","EVENT_NO":"4183708","INSPECTION_BEGIN_DT":"09/29/2003","INSPECTION_END_DT":"09/30/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"8.75","sourceDate":"2003-09-29"},{"SOURCE_ROW_NUMBER":"879480","EVENT_NO":"4175037","INSPECTION_BEGIN_DT":"07/23/2003","INSPECTION_END_DT":"09/15/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"75","SUM_TOTAL_ON_SITE_HOURS":"42","sourceDate":"2003-07-23"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":29,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q3":{"hours":1857,"employees":8,"production":6028},"2004-Q2":{"hours":3634,"employees":15,"production":4601},"2004-Q1":{"hours":4850,"employees":13,"production":13303},"2003-Q4":{"hours":6470,"employees":17,"production":12208},"2002-Q3":{"hours":5915,"employees":18,"production":13382},"2002-Q2":{"hours":7142,"employees":21,"production":16142},"2002-Q1":{"hours":6875,"employees":18,"production":15056},"2001-Q1":{"hours":5367,"employees":15,"production":23395},"2000-Q4":{"hours":5494,"employees":14,"production":14372},"2000-Q3":{"hours":4775,"employees":13,"production":15166},"2000-Q2":{"hours":4775,"employees":19,"production":15899},"2000-Q1":{"hours":3999,"employees":17,"production":16415}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":19043,"employees":17,"production":61852},"2001":{"hours":5367,"employees":15,"production":23395},"2002":{"hours":19932,"employees":19,"production":44580},"2003":{"hours":6470,"employees":17,"production":12208},"2004":{"hours":10341,"employees":13,"production":23932}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":24,"firstDate":"2000-02-03","lastDate":"2004-03-16","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":1255,"pelDoseTotal":872},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"59795","EVENT_NO":"4175318","SURVEY_DATE":"03/16/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"36","MANUFACTURER_CD":"043","ACT_DOSE_85":"61","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2004-03-16"},{"SOURCE_ROW_NUMBER":"59794","EVENT_NO":"4175318","SURVEY_DATE":"03/16/2004","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"55","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2004-03-16"},{"SOURCE_ROW_NUMBER":"59793","EVENT_NO":"4175318","SURVEY_DATE":"03/16/2004","OCCUPATION_CD_DESC":"BLASTER/SHOOTER/SHOTFIRER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"62","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2004-03-16"},{"SOURCE_ROW_NUMBER":"59792","EVENT_NO":"4175318","SURVEY_DATE":"03/16/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"38","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2004-03-16"},{"SOURCE_ROW_NUMBER":"59791","EVENT_NO":"4175318","SURVEY_DATE":"03/16/2004","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"41","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2004-03-16"},{"SOURCE_ROW_NUMBER":"59800","EVENT_NO":"4175535","SURVEY_DATE":"02/20/2003","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"24","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2003-02-20"},{"SOURCE_ROW_NUMBER":"59799","EVENT_NO":"4175535","SURVEY_DATE":"02/20/2003","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"17","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2003-02-20"},{"SOURCE_ROW_NUMBER":"59798","EVENT_NO":"4175535","SURVEY_DATE":"02/20/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"36","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2003-02-20"},{"SOURCE_ROW_NUMBER":"59797","EVENT_NO":"4175535","SURVEY_DATE":"02/20/2003","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"15","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2003-02-20"},{"SOURCE_ROW_NUMBER":"59796","EVENT_NO":"4175535","SURVEY_DATE":"02/20/2003","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"41","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2003-02-20"},{"SOURCE_ROW_NUMBER":"59790","EVENT_NO":"4174474","SURVEY_DATE":"02/27/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"64","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2002-02-27"},{"SOURCE_ROW_NUMBER":"59789","EVENT_NO":"4174474","SURVEY_DATE":"02/27/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"56","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2002-02-27"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":28,"firstDate":"2000-02-08","lastDate":"2004-01-07","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":7,"validSamples":28,"quartzPctTotal":106.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"126286","CASSETTE_NO":"57543920","SAMPLE_DT":"01/07/2004","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-07"},{"SOURCE_ROW_NUMBER":"2321","CASSETTE_NO":"57543928","SAMPLE_DT":"01/07/2004","QUARTZ_PCT":"01.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-07"},{"SOURCE_ROW_NUMBER":"57758","CASSETTE_NO":"57481118","SAMPLE_DT":"09/29/2003","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-09-29"},{"SOURCE_ROW_NUMBER":"45561","CASSETTE_NO":"57481105","SAMPLE_DT":"09/29/2003","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-09-29"},{"SOURCE_ROW_NUMBER":"110580","CASSETTE_NO":"57446919","SAMPLE_DT":"02/20/2003","QUARTZ_PCT":"00.4","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-02-20"},{"SOURCE_ROW_NUMBER":"46278","CASSETTE_NO":"57446950","SAMPLE_DT":"02/20/2003","QUARTZ_PCT":"03.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-02-20"},{"SOURCE_ROW_NUMBER":"144880","CASSETTE_NO":"57431217","SAMPLE_DT":"10/22/2002","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"142944","CASSETTE_NO":"57431218","SAMPLE_DT":"10/22/2002","QUARTZ_PCT":"02.0","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"8626","CASSETTE_NO":"57431225","SAMPLE_DT":"10/22/2002","QUARTZ_PCT":"02.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"147336","CASSETTE_NO":"57410541","SAMPLE_DT":"09/17/2002","QUARTZ_PCT":"03.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"154948","CASSETTE_NO":"57410289","SAMPLE_DT":"05/28/2002","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-28"},{"SOURCE_ROW_NUMBER":"64957","CASSETTE_NO":"57410286","SAMPLE_DT":"05/28/2002","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-28"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":268,"firstDate":"2000-01-13","lastDate":"2004-07-13","metrics":{"ss":112,"amountDue":29544,"contested":0,"amountPaid":29544,"recentRows":0,"section104d":0,"unterminated":3,"proposedPenalty":29544},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"882645","VIOLATION_NO":"7408876","VIOLATION_ISSUE_DT":"07/13/2004","PART_SECTION":"75.1711-3","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"07/21/2004","CONTESTED_IND":"N","sourceDate":"2004-07-13"},{"SOURCE_ROW_NUMBER":"882643","VIOLATION_NO":"7408868","VIOLATION_ISSUE_DT":"07/08/2004","SIG_SUB":"N","PART_SECTION":"75.1711-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"291","AMOUNT_DUE":"291","AMOUNT_PAID":"291","CONTESTED_IND":"N","sourceDate":"2004-07-08"},{"SOURCE_ROW_NUMBER":"882644","VIOLATION_NO":"7408869","VIOLATION_ISSUE_DT":"07/07/2004","SIG_SUB":"N","PART_SECTION":"77.208(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/13/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-07-07"},{"SOURCE_ROW_NUMBER":"882614","VIOLATION_NO":"7404210","VIOLATION_ISSUE_DT":"05/04/2004","SIG_SUB":"Y","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/06/2004","PROPOSED_PENALTY":"203","AMOUNT_DUE":"203","AMOUNT_PAID":"203","CONTESTED_IND":"N","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"882613","VIOLATION_NO":"7404202","VIOLATION_ISSUE_DT":"04/28/2004","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/28/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-28"},{"SOURCE_ROW_NUMBER":"882612","VIOLATION_NO":"7404201","VIOLATION_ISSUE_DT":"04/28/2004","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/28/2004","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2004-04-28"},{"SOURCE_ROW_NUMBER":"882611","VIOLATION_NO":"7404200","VIOLATION_ISSUE_DT":"04/27/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/28/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-27"},{"SOURCE_ROW_NUMBER":"882610","VIOLATION_NO":"7404199","VIOLATION_ISSUE_DT":"04/27/2004","PART_SECTION":"75.1107-4(a)(2)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/28/2004","CONTESTED_IND":"N","sourceDate":"2004-04-27"},{"SOURCE_ROW_NUMBER":"882607","VIOLATION_NO":"4026527","VIOLATION_ISSUE_DT":"04/19/2004","SIG_SUB":"Y","PART_SECTION":"75.1107-4(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"383","AMOUNT_DUE":"383","AMOUNT_PAID":"383","CONTESTED_IND":"N","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"882609","VIOLATION_NO":"7404191","VIOLATION_ISSUE_DT":"04/12/2004","SIG_SUB":"Y","PART_SECTION":"75.402","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2004","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2004-04-12"},{"SOURCE_ROW_NUMBER":"882608","VIOLATION_NO":"7404190","VIOLATION_ISSUE_DT":"04/12/2004","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2004","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2004-04-12"},{"SOURCE_ROW_NUMBER":"882545","VIOLATION_NO":"7404272","VIOLATION_ISSUE_DT":"02/24/2004","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/01/2004","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"154","CONTESTED_IND":"N","sourceDate":"2004-02-24"}]}],"safety":{"href":"/api/v1/mines/1517407/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517407/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Openings of active mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711-3","part":"75","subchapter":"O","subpart":"R","id":"75.1711-3","citation":"30 CFR 75.1711-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.402","heading":"Rock dusting.","id":"75.402","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.402","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"[Statutory Provision]\n\nAll underground areas of a coal mine, except those areas in which the dust is too wet or too high in incombustible content to propagate an explosion, shall be rock dusted to within 40 feet of all working faces, unless such areas are inaccessible or unsafe to enter or unless the Secretary or his authorized representative permits an exception upon his finding that such exception will not pose a hazard to the miners. All crosscuts that are less than 40 feet from a working face shall also be rock dusted.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517407","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}