{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1517390","name":"#1","status":"Abandoned and Sealed","status_date":"2012-05-11","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Floyd","nearest_town":"Endicott","operator_id":"0059505","operator_name":"LA Energy, LLC","controller_id":"0049573","controller_name":"Vhonda  Dotson","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.635833,"longitude":-82.668055},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1921},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517390","name":"#1"},"operator":{"type":"operator","id":"0059505","name":"LA Energy, LLC"},"controller":{"type":"controller","id":"0049573","name":"Vhonda  Dotson"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C09233","name":"Larry  Cantrell"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1983-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|C09233|1983-03-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12243","name":"Goble R Don"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1993-02-19","validTo":"1994-04-05","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|C12243|1993-02-19|1994-04-05"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22264","name":"B & D Coal Company Inc"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1993-04-01","validTo":"1993-04-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P22264|1993-04-01|1993-04-21"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12243","name":"Goble R Don"},"object":{"type":"operator","id":"P22264","name":"B & D Coal Company Inc"},"validFrom":"1993-04-01","validTo":"1993-04-21","current":false,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P22264|1993-04-01|C12243|1993-02-19|86465"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22406","name":"Sometime Mining Corp"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1993-04-22","validTo":"1993-12-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P22406|1993-04-22|1993-12-13"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12243","name":"Goble R Don"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1993-04-22","validTo":"1993-12-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|C12243|1993-04-22|1993-12-13"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12243","name":"Goble R Don"},"object":{"type":"operator","id":"P22406","name":"Sometime Mining Corp"},"validFrom":"1993-04-22","validTo":"1993-12-13","current":false,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P22406|1993-04-22|C12243|1993-04-22|86466"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13728","name":"Charles  Hunt"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1993-09-01","validTo":"2000-03-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|C13728|1993-09-01|2000-03-07"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P14094","name":"Cedar Grove Mining Inc"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1993-12-14","validTo":"1994-11-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P14094|1993-12-14|1994-11-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C09233","name":"Larry  Cantrell"},"object":{"type":"operator","id":"P14094","name":"Cedar Grove Mining Inc"},"validFrom":"1993-12-14","validTo":"1994-11-29","current":false,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P14094|1993-12-14|C09233|1983-03-01|79148"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22558","name":"J Cress Enterprises Inc"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1994-11-30","validTo":"1995-09-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P22558|1994-11-30|1995-09-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13728","name":"Charles  Hunt"},"object":{"type":"operator","id":"P22558","name":"J Cress Enterprises Inc"},"validFrom":"1994-11-30","validTo":"1995-09-11","current":false,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P22558|1994-11-30|C13728|1993-09-01|90946"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23237","name":"Hope Mining Inc"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1995-09-12","validTo":"1998-01-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P23237|1995-09-12|1998-01-11"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12171","name":"Eurmel  Hunter"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1995-09-12","validTo":"1998-01-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|C12171|1995-09-12|1998-01-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12171","name":"Eurmel  Hunter"},"object":{"type":"operator","id":"P23237","name":"Hope Mining Inc"},"validFrom":"1995-09-12","validTo":"1998-01-11","current":false,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P23237|1995-09-12|C12171|1995-09-12|86287"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23875","name":"Deanco Mining Inc"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1998-01-12","validTo":"1998-11-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P23875|1998-01-12|1998-11-30"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15666","name":"Keathley Brent"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1998-01-12","validTo":"1998-11-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|C15666|1998-01-12|1998-11-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15666","name":"Keathley Brent"},"object":{"type":"operator","id":"P23875","name":"Deanco Mining Inc"},"validFrom":"1998-01-12","validTo":"1998-11-30","current":false,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P23875|1998-01-12|C15666|1998-01-12|96460"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24052","name":"Bren-Co Inc"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1998-12-01","validTo":"1999-04-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P24052|1998-12-01|1999-04-08"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11537","name":"Robert B  Hughes"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1998-12-01","validTo":"1999-04-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|C11537|1998-12-01|1999-04-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11537","name":"Robert B  Hughes"},"object":{"type":"operator","id":"P24052","name":"Bren-Co Inc"},"validFrom":"1998-12-01","validTo":"1999-04-08","current":false,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P24052|1998-12-01|C11537|1998-12-01|84828"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14345","name":"Pamela J  Allen"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1999-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|C14345|1999-02-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24152","name":"Triple J Mining Inc"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1999-04-09","validTo":"2000-01-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P24152|1999-04-09|2000-01-03"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15826","name":"Wright Terry"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"1999-04-09","validTo":"2000-01-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|C15826|1999-04-09|2000-01-03"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15826","name":"Wright Terry"},"object":{"type":"operator","id":"P24152","name":"Triple J Mining Inc"},"validFrom":"1999-04-09","validTo":"2000-01-03","current":false,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P24152|1999-04-09|C15826|1999-04-09|96862"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24099","name":"Sly Branch Energy Inc"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"2000-01-04","validTo":"2005-05-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P24099|2000-01-04|2005-05-03"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14345","name":"Pamela J  Allen"},"object":{"type":"operator","id":"P24099","name":"Sly Branch Energy Inc"},"validFrom":"2000-01-04","validTo":"2005-05-03","current":false,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|P24099|2000-01-04|C14345|1999-02-01|92543"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0059505","name":"LA Energy, LLC"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"2005-05-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|0059505|2005-05-04|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0049573","name":"Vhonda  Dotson"},"object":{"type":"mine","id":"1517390","name":"#1"},"validFrom":"2005-05-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|0049573|2005-05-04|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0049573","name":"Vhonda  Dotson"},"object":{"type":"operator","id":"0059505","name":"LA Energy, LLC"},"validFrom":"2005-05-04","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517390|0059505|2005-05-04|0049573|2005-05-04|6208"}}],"coverage":{"historyRecords":10,"edgeCount":30,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":9,"firstDate":"2001-10-19","lastDate":"2005-07-23","metrics":{"daysLost":436,"injuries":7,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"190524","DOCUMENT_NO":"220052100039","ACCIDENT_DT":"07/23/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Blaster, Shooter, Shotfirer, Explosive worker, Powder gang/monkey","NO_INJURIES":"1","DAYS_LOST":"24","NARRATIVE":"EE WAS LOADING HIGHLINE CABLE INTO SCOOP BUCKET AND PUT HIS FOOT UNDER THE SCOOP BUCKET.  THE SCOOP OPERATOR LET THE BUCKET DOWN ON EE'S FOOT AND BROKE THE 3 MIDDLE TOES ON HIS RIGHT FOOT.","sourceDate":"2005-07-23"},{"SOURCE_ROW_NUMBER":"164814","DOCUMENT_NO":"220050960041","ACCIDENT_DT":"03/24/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"313","NARRATIVE":"EE CAME OUTSIDE AT END OF SHIFT ON 3/23/05 COMPLAINING KNEE WAS HURTING. WE TOLD EE WORKERS COMP WOULD NOT COVER SORE KNEES. EE CAME BACK TO WORK ON 3/24/05, WORKED ABOUT 3 HRS AND SAID EE HURT BACK SHOVELING AROUND A BELT DRIVE","sourceDate":"2005-03-24"},{"SOURCE_ROW_NUMBER":"160528","DOCUMENT_NO":"220042110017","ACCIDENT_DT":"07/14/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"EMPLOYEE GRABBED A ROCK TO GET IT OFF THE FEEDER WHILE THE FEEDER WAS RUNNING. THE ROCK KICKED UP & FOULED HIS HAND AGAINST THE ROOF, BRUISING HIS HAND AND CUTTING HIS FINGERS.","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"186308","DOCUMENT_NO":"220032480027","ACCIDENT_DT":"06/27/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"PRE-SHIFT MINE EXAMINER FOUND INTERSECTION OF #8 HEADING BELLIED DOWN IN LAST CROSSCUT TO FACE. ENTRY WAS CRIBBED OFF AT MOUTH OF PLACE. PRESHIFTED ABOUT 6:30 AM. FELL AT ABOUT 12:30 PM.","sourceDate":"2003-06-27"},{"SOURCE_ROW_NUMBER":"104336","DOCUMENT_NO":"220031750056","ACCIDENT_DT":"05/14/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"SCOOP OPERATOR WAS TAKING SCOOP TO BATTERY BARN TO CHANGE BATTERIES WHEN SOME DRAW ROCK FELL IN OPERATOR'S DECK AND ON EMPLOYEE. EMPLOYEE WAS BRUISED ON SOME PARTS OF BODY.","sourceDate":"2003-05-14"},{"SOURCE_ROW_NUMBER":"117313","DOCUMENT_NO":"220030690096","ACCIDENT_DT":"02/28/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE RAN OVER A ROCK WITH SCOOP AND IT PUT THE OPERATORS DECK OF THE SCOOP INTO THE ROOF. EE'S SHOULDER HIT THE ROOF AND IT BRUISED HIS SHOULDER.","sourceDate":"2003-02-28"},{"SOURCE_ROW_NUMBER":"164813","DOCUMENT_NO":"220030690095","ACCIDENT_DT":"02/27/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"63","NARRATIVE":"EE WAS USING SCOOP TO CLEAN UNDER BELT. BELT WAS HUNG IN HIGH TOP AND AS HE SCOOPED UNDER BELT AND BACKED UP FROM HIGH TOP TO LOW TOP, HIS JACKET HOOKED ON A ROOF BOLT PLATE AND IT DRAGGED HIM OFF OF THE SCOOP, BREAKING HIS WRIST.","sourceDate":"2003-02-27"},{"SOURCE_ROW_NUMBER":"237929","DOCUMENT_NO":"220023360072","ACCIDENT_DT":"11/15/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"19","NARRATIVE":"WE WERE USING A SCOOP, WIRE ROPE AND A PULL BLOCK TO PULL CONVEYER BELT TOGETHER WHEN A CHAIN HOLDING THE PULL BLOCK BROKE LETTING THE WIRE ROPE LOOSE. THE WIRE ROPE PINNED EE AGAINST RIB AND BRUISED HIM.","sourceDate":"2002-11-15"},{"SOURCE_ROW_NUMBER":"268004","DOCUMENT_NO":"220013020048","ACCIDENT_DT":"10/19/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"TURNED A BREAK IN #6 ENTRY. CLEANED IT UP WNET BACK TO BOLT IT AND FOUND A 40' CRACK IN ROOF. PUT UP 5' BOLTS TO SPOT BOLT WITH. BOLTER MAN BACKED OUT OF ENTRY AT ABOUT 1400 TO LET ROOF SETTLE . IT FELL AT 1445.","sourceDate":"2001-10-19"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-05-11","lastDate":"2012-05-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":477,"firstDate":"2000-03-15","lastDate":"2005-12-02","metrics":{"ss":223,"delinquent":477,"recentRows":0,"paidPenalty":2156,"proposedPenalty":127806,"currentAssessment":127806},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1016761","VIOLATION_NO":"7424255","ISSUE_DT":"12/02/2005","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"254.00","CURRENT_ASSESSMENT_AMT":"254.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-02"},{"SOURCE_ROW_NUMBER":"1015445","VIOLATION_NO":"7422873","ISSUE_DT":"07/11/2005","CFR_STANDARD_CD":"75.360(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-07-11"},{"SOURCE_ROW_NUMBER":"1015336","VIOLATION_NO":"7422864","ISSUE_DT":"06/16/2005","CFR_STANDARD_CD":"77.900-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-16"},{"SOURCE_ROW_NUMBER":"1015335","VIOLATION_NO":"7422863","ISSUE_DT":"06/16/2005","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-16"},{"SOURCE_ROW_NUMBER":"1015334","VIOLATION_NO":"7422862","ISSUE_DT":"06/14/2005","CFR_STANDARD_CD":"75.523-1(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"107.00","CURRENT_ASSESSMENT_AMT":"107.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"1015333","VIOLATION_NO":"7422861","ISSUE_DT":"06/14/2005","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"107.00","CURRENT_ASSESSMENT_AMT":"107.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"1015332","VIOLATION_NO":"7422860","ISSUE_DT":"06/14/2005","CFR_STANDARD_CD":"75.523-1(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"107.00","CURRENT_ASSESSMENT_AMT":"107.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"1015331","VIOLATION_NO":"7422859","ISSUE_DT":"06/14/2005","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"107.00","CURRENT_ASSESSMENT_AMT":"107.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"1015330","VIOLATION_NO":"7422858","ISSUE_DT":"06/14/2005","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"107.00","CURRENT_ASSESSMENT_AMT":"107.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"1015329","VIOLATION_NO":"7422857","ISSUE_DT":"06/14/2005","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"107.00","CURRENT_ASSESSMENT_AMT":"107.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"1015328","VIOLATION_NO":"7422856","ISSUE_DT":"06/14/2005","CFR_STANDARD_CD":"75.1100-1(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"1015327","VIOLATION_NO":"7422855","ISSUE_DT":"06/09/2005","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"254.00","CURRENT_ASSESSMENT_AMT":"254.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-09"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":347,"firstDate":"2000-01-31","lastDate":"2006-01-17","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":15,"validSamples":332,"maxConcentration":4.976,"concentrationTotal":279.684},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"395814","CASS_NUM":"50835051","SMP_TAKEN_DT":"1/17/2006","CONC":".445","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-01-17"},{"SOURCE_ROW_NUMBER":"290628","CASS_NUM":"57575496","SMP_TAKEN_DT":"6/16/2005","CONC":".135","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BELT MAN/CONVEYOR MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-06-16"},{"SOURCE_ROW_NUMBER":"1329514","CASS_NUM":"57575999","SMP_TAKEN_DT":"5/24/2005","CONC":"1.985","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"1215046","CASS_NUM":"57575982","SMP_TAKEN_DT":"5/24/2005","CONC":".427","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"1199251","CASS_NUM":"57575992","SMP_TAKEN_DT":"5/24/2005","CONC":"1.548","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"979193","CASS_NUM":"57575938","SMP_TAKEN_DT":"5/24/2005","CONC":"1.195","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"110295","CASS_NUM":"57575993","SMP_TAKEN_DT":"5/24/2005","CONC":"1.609","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"174378","CASS_NUM":"50803055","SMP_TAKEN_DT":"5/23/2005","CONC":".866","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-23"},{"SOURCE_ROW_NUMBER":"1071541","CASS_NUM":"50803011","SMP_TAKEN_DT":"5/20/2005","CONC":"1.081","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-20"},{"SOURCE_ROW_NUMBER":"1129869","CASS_NUM":"50803012","SMP_TAKEN_DT":"5/19/2005","CONC":"1.003","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-19"},{"SOURCE_ROW_NUMBER":"1265179","CASS_NUM":"50730835","SMP_TAKEN_DT":"5/18/2005","CONC":"1.072","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-18"},{"SOURCE_ROW_NUMBER":"970684","CASS_NUM":"50803050","SMP_TAKEN_DT":"5/17/2005","CONC":".967","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-17"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":24,"firstDate":"2001-01-11","lastDate":"2005-06-29","metrics":{"linkedIssuances":24},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":313,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":46,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":10,"firstDate":"1993-04-01","lastDate":"2005-05-04","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":9},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":90,"firstDate":"2000-01-25","lastDate":"2005-11-28","metrics":{"inspectors":125,"recentRows":0,"onSiteHours":1889,"inspectionHours":2817.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"736017","EVENT_NO":"4188844","INSPECTION_BEGIN_DT":"11/28/2005","INSPECTION_END_DT":"11/28/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-11-28"},{"SOURCE_ROW_NUMBER":"748670","EVENT_NO":"4189269","INSPECTION_BEGIN_DT":"10/19/2005","INSPECTION_END_DT":"12/28/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2005-10-19"},{"SOURCE_ROW_NUMBER":"355763","EVENT_NO":"4189078","INSPECTION_BEGIN_DT":"07/08/2005","INSPECTION_END_DT":"08/22/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2005-07-08"},{"SOURCE_ROW_NUMBER":"532176","EVENT_NO":"4189063","INSPECTION_BEGIN_DT":"04/05/2005","INSPECTION_END_DT":"06/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"168","SUM_TOTAL_ON_SITE_HOURS":"106","sourceDate":"2005-04-05"},{"SOURCE_ROW_NUMBER":"93179","EVENT_NO":"4189060","INSPECTION_BEGIN_DT":"03/07/2005","INSPECTION_END_DT":"03/15/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2005-03-07"},{"SOURCE_ROW_NUMBER":"1149868","EVENT_NO":"4189054","INSPECTION_BEGIN_DT":"01/05/2005","INSPECTION_END_DT":"01/25/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2005-01-05"},{"SOURCE_ROW_NUMBER":"1089027","EVENT_NO":"4189053","INSPECTION_BEGIN_DT":"01/05/2005","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"110.5","SUM_TOTAL_ON_SITE_HOURS":"83","sourceDate":"2005-01-05"},{"SOURCE_ROW_NUMBER":"678354","EVENT_NO":"4184763","INSPECTION_BEGIN_DT":"10/05/2004","INSPECTION_END_DT":"12/08/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"80.5","SUM_TOTAL_ON_SITE_HOURS":"62","sourceDate":"2004-10-05"},{"SOURCE_ROW_NUMBER":"310173","EVENT_NO":"4184767","INSPECTION_BEGIN_DT":"10/05/2004","INSPECTION_END_DT":"10/07/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2004-10-05"},{"SOURCE_ROW_NUMBER":"17874","EVENT_NO":"4184766","INSPECTION_BEGIN_DT":"10/05/2004","INSPECTION_END_DT":"10/15/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2004-10-05"},{"SOURCE_ROW_NUMBER":"384930","EVENT_NO":"4184752","INSPECTION_BEGIN_DT":"09/07/2004","INSPECTION_END_DT":"09/30/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-09-07"},{"SOURCE_ROW_NUMBER":"548005","EVENT_NO":"4183845","INSPECTION_BEGIN_DT":"07/22/2004","INSPECTION_END_DT":"08/09/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2004-07-22"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":45,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q1":{"hours":0,"employees":0,"production":0},"2005-Q4":{"hours":0,"employees":0,"production":0},"2005-Q3":{"hours":0,"employees":0,"production":0},"2005-Q2":{"hours":1424,"employees":19,"production":3759},"2005-Q1":{"hours":4537,"employees":13,"production":24435},"2004-Q4":{"hours":12042,"employees":18,"production":26675},"2004-Q3":{"hours":9297,"employees":19,"production":21059},"2004-Q2":{"hours":11852,"employees":18,"production":30590},"2004-Q1":{"hours":1359,"employees":7,"production":13477},"2003-Q3":{"hours":3561,"employees":11,"production":25851},"2003-Q2":{"hours":4891,"employees":11,"production":31797},"2003-Q1":{"hours":4672,"employees":10,"production":31517}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":9,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":27530,"employees":18,"production":76326},"2002":{"hours":20695,"employees":14,"production":111485},"2003":{"hours":13124,"employees":11,"production":89165},"2004":{"hours":34550,"employees":15,"production":91801},"2005":{"hours":5961,"employees":17,"production":28194}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":26,"firstDate":"2001-07-25","lastDate":"2004-10-07","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":1492,"pelDoseTotal":1023},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"59758","EVENT_NO":"4184767","SURVEY_DATE":"10/07/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"118","PEL_DOSE_90":"100","SURVEY_TYPE":"I","sourceDate":"2004-10-07"},{"SOURCE_ROW_NUMBER":"59757","EVENT_NO":"4184767","SURVEY_DATE":"10/07/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"105","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2004-10-07"},{"SOURCE_ROW_NUMBER":"59756","EVENT_NO":"4184767","SURVEY_DATE":"10/07/2004","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"100","ACT_DOSE_85":"92","PEL_DOSE_90":"87","SURVEY_TYPE":"I","sourceDate":"2004-10-07"},{"SOURCE_ROW_NUMBER":"59755","EVENT_NO":"4184767","SURVEY_DATE":"10/07/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"85","PEL_DOSE_90":"66","SURVEY_TYPE":"I","sourceDate":"2004-10-07"},{"SOURCE_ROW_NUMBER":"59754","EVENT_NO":"4184767","SURVEY_DATE":"10/07/2004","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"130","PEL_DOSE_90":"120","SURVEY_TYPE":"I","sourceDate":"2004-10-07"},{"SOURCE_ROW_NUMBER":"59753","EVENT_NO":"4183846","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"43","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"59752","EVENT_NO":"4183846","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"62","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"59751","EVENT_NO":"4183846","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"58","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"59750","EVENT_NO":"4183846","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"100","ACT_DOSE_85":"38","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"59749","EVENT_NO":"4183846","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"41","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"59748","EVENT_NO":"4175263","SURVEY_DATE":"12/10/2002","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"61","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2002-12-10"},{"SOURCE_ROW_NUMBER":"59747","EVENT_NO":"4175263","SURVEY_DATE":"12/10/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"46","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2002-12-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":23,"firstDate":"2000-05-10","lastDate":"2005-05-24","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":33.8,"validSamples":22,"quartzPctTotal":73.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"16761","CASSETTE_NO":"57575938","SAMPLE_DT":"05/24/2005","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"119863","CASSETTE_NO":"57577010","SAMPLE_DT":"01/25/2005","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"142834","CASSETTE_NO":"57507687","SAMPLE_DT":"10/07/2004","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-10-07"},{"SOURCE_ROW_NUMBER":"130223","CASSETTE_NO":"57507885","SAMPLE_DT":"09/20/2004","QUARTZ_PCT":"01.0","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-09-20"},{"SOURCE_ROW_NUMBER":"158648","CASSETTE_NO":"57508663","SAMPLE_DT":"07/28/2004","QUARTZ_PCT":"01.0","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"160270","CASSETTE_NO":"57563311","SAMPLE_DT":"05/24/2004","QUARTZ_PCT":"00.9","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-24"},{"SOURCE_ROW_NUMBER":"54783","CASSETTE_NO":"57563562","SAMPLE_DT":"03/30/2004","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-03-30"},{"SOURCE_ROW_NUMBER":"30518","CASSETTE_NO":"57458459","SAMPLE_DT":"05/21/2003","QUARTZ_PCT":"00.8","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-05-21"},{"SOURCE_ROW_NUMBER":"150060","CASSETTE_NO":"50685958","SAMPLE_DT":"04/04/2003","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2003-04-04"},{"SOURCE_ROW_NUMBER":"13644","CASSETTE_NO":"57468157","SAMPLE_DT":"03/19/2003","QUARTZ_PCT":"08.0","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-03-19"},{"SOURCE_ROW_NUMBER":"28854","CASSETTE_NO":"57468131","SAMPLE_DT":"03/18/2003","QUARTZ_PCT":"05.3","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-03-18"},{"SOURCE_ROW_NUMBER":"95478","CASSETTE_NO":"50657714","SAMPLE_DT":"02/20/2003","QUARTZ_PCT":"00.2","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-02-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":500,"firstDate":"2000-03-15","lastDate":"2005-12-19","metrics":{"ss":229,"amountDue":127806,"contested":0,"amountPaid":2156,"recentRows":0,"section104d":18,"unterminated":14,"proposedPenalty":127806},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"882354","VIOLATION_NO":"7424260","VIOLATION_ISSUE_DT":"12/19/2005","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/19/2006","CONTESTED_IND":"N","sourceDate":"2005-12-19"},{"SOURCE_ROW_NUMBER":"882353","VIOLATION_NO":"7424255","VIOLATION_ISSUE_DT":"12/02/2005","SIG_SUB":"Y","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"254","AMOUNT_DUE":"254","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-12-02"},{"SOURCE_ROW_NUMBER":"882129","VIOLATION_NO":"7423404","VIOLATION_ISSUE_DT":"07/27/2005","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/19/2006","CONTESTED_IND":"N","sourceDate":"2005-07-27"},{"SOURCE_ROW_NUMBER":"882128","VIOLATION_NO":"7422873","VIOLATION_ISSUE_DT":"07/11/2005","SIG_SUB":"N","PART_SECTION":"75.360(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/27/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-07-11"},{"SOURCE_ROW_NUMBER":"882065","VIOLATION_NO":"7422864","VIOLATION_ISSUE_DT":"06/16/2005","SIG_SUB":"N","PART_SECTION":"77.900-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/22/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-06-16"},{"SOURCE_ROW_NUMBER":"882064","VIOLATION_NO":"7422863","VIOLATION_ISSUE_DT":"06/16/2005","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/22/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-06-16"},{"SOURCE_ROW_NUMBER":"882063","VIOLATION_NO":"7422862","VIOLATION_ISSUE_DT":"06/14/2005","SIG_SUB":"Y","PART_SECTION":"75.523-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/15/2005","PROPOSED_PENALTY":"107","AMOUNT_DUE":"107","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"882062","VIOLATION_NO":"7422861","VIOLATION_ISSUE_DT":"06/14/2005","SIG_SUB":"Y","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/28/2005","PROPOSED_PENALTY":"107","AMOUNT_DUE":"107","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"882061","VIOLATION_NO":"7422860","VIOLATION_ISSUE_DT":"06/14/2005","SIG_SUB":"Y","PART_SECTION":"75.523-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/15/2005","PROPOSED_PENALTY":"107","AMOUNT_DUE":"107","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"882060","VIOLATION_NO":"7422859","VIOLATION_ISSUE_DT":"06/14/2005","SIG_SUB":"Y","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/15/2005","PROPOSED_PENALTY":"107","AMOUNT_DUE":"107","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"882059","VIOLATION_NO":"7422858","VIOLATION_ISSUE_DT":"06/14/2005","SIG_SUB":"Y","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/14/2005","PROPOSED_PENALTY":"107","AMOUNT_DUE":"107","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-06-14"},{"SOURCE_ROW_NUMBER":"882058","VIOLATION_NO":"7422857","VIOLATION_ISSUE_DT":"06/14/2005","SIG_SUB":"Y","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/15/2005","PROPOSED_PENALTY":"107","AMOUNT_DUE":"107","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-06-14"}]}],"safety":{"href":"/api/v1/mines/1517390/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517390/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; procedures.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.900-1","part":"77","subchapter":"O","subpart":"J","id":"77.900-1","citation":"30 CFR 77.900-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment installation requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-1","part":"75","subchapter":"O","subpart":"F","id":"75.523-1","citation":"30 CFR 75.523-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517390","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}