{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1517260","name":"Eagle Mine","status":"Abandoned","status_date":"2006-07-25","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Robinson Creek","operator_id":"P02779","operator_name":"Jet Coal Company Incorporated","controller_id":"C00996","controller_name":"Anthony  Newsome","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.362777,"longitude":-82.636666},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":2227},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1517260","name":"Eagle Mine"},"operator":{"type":"operator","id":"P02779","name":"Jet Coal Company Incorporated"},"controller":{"type":"controller","id":"C00996","name":"Anthony  Newsome"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00996","name":"Anthony  Newsome"},"object":{"type":"mine","id":"1517260","name":"Eagle Mine"},"validFrom":"1975-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517260|C00996|1975-04-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C08125","name":"Ronald S  Ratliff"},"object":{"type":"mine","id":"1517260","name":"Eagle Mine"},"validFrom":"1988-07-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517260|C08125|1988-07-08|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19607","name":"R S Mining Inc"},"object":{"type":"mine","id":"1517260","name":"Eagle Mine"},"validFrom":"1992-07-01","validTo":"1997-06-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517260|P19607|1992-07-01|1997-06-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C08125","name":"Ronald S  Ratliff"},"object":{"type":"operator","id":"P19607","name":"R S Mining Inc"},"validFrom":"1992-07-01","validTo":"1997-06-29","current":false,"derived":true,"evidenceMineId":"1517260","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517260|P19607|1992-07-01|C08125|1988-07-08|76409"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P02779","name":"Jet Coal Company Incorporated"},"object":{"type":"mine","id":"1517260","name":"Eagle Mine"},"validFrom":"1997-06-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517260|P02779|1997-06-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00996","name":"Anthony  Newsome"},"object":{"type":"operator","id":"P02779","name":"Jet Coal Company Incorporated"},"validFrom":"1997-06-30","validTo":null,"current":true,"derived":true,"evidenceMineId":"1517260","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1517260|P02779|1997-06-30|C00996|1975-04-01|51557"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":25,"firstDate":"2000-08-29","lastDate":"2006-03-27","metrics":{"daysLost":335,"injuries":25,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"48645","DOCUMENT_NO":"220061010035","ACCIDENT_DT":"03/27/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Pulling miner cable out of roadway hurt his back","sourceDate":"2006-03-27"},{"SOURCE_ROW_NUMBER":"35761","DOCUMENT_NO":"220060720057","ACCIDENT_DT":"02/27/2006","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall on # 5 belt between spads 825-826, 280' from #5 head drive. Size of the fall 20' X 70' X 5'.","sourceDate":"2006-02-27"},{"SOURCE_ROW_NUMBER":"173382","DOCUMENT_NO":"220053530089","ACCIDENT_DT":"12/01/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"31","NARRATIVE":"While pulling belt together with red devil, the red devil cable broke and belt clamps hit him on his ankle.","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1347","DOCUMENT_NO":"220052270082","ACCIDENT_DT":"07/21/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Belt foreman, Maintenance foreman, Maintenance supervisor","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"He said he was stepping off tailpiece and turned his knee.","sourceDate":"2005-07-21"},{"SOURCE_ROW_NUMBER":"52943","DOCUMENT_NO":"220051710083","ACCIDENT_DT":"06/13/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"ROOF FALL ON RETURN LEFT AIR COURSE APP 4500' FROM OUTSIDE. SIZ OF FALL 20 X 30 X 6 FEET","sourceDate":"2005-06-13"},{"SOURCE_ROW_NUMBER":"35760","DOCUMENT_NO":"220051680065","ACCIDENT_DT":"05/25/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"26","NARRATIVE":"WHILE TRAMMING CAR TOO CLOSE TO THE RIB, PINCHED ARM BETWEEN CAR AND RIB.","sourceDate":"2005-05-25"},{"SOURCE_ROW_NUMBER":"164807","DOCUMENT_NO":"220051460041","ACCIDENT_DT":"05/10/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"9","NARRATIVE":"While holding up belt scraper arm the man on the other side dropped his end over loading injured's side. Injured fell on his knee.","sourceDate":"2005-05-10"},{"SOURCE_ROW_NUMBER":"48644","DOCUMENT_NO":"220050310039","ACCIDENT_DT":"01/18/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"18","NARRATIVE":"He was sitting on rear of roof bolter with head down on arms when a rock fell hitting his head.","sourceDate":"2005-01-18"},{"SOURCE_ROW_NUMBER":"224964","DOCUMENT_NO":"220043230031","ACCIDENT_DT":"11/03/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"32","NARRATIVE":"While helping clean out hose, he placed his hand in a pinch point. Operator raised boom pinching finger.","sourceDate":"2004-11-03"},{"SOURCE_ROW_NUMBER":"44314","DOCUMENT_NO":"220041280059","ACCIDENT_DT":"04/19/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"19","NARRATIVE":"EE PUT HAND ON GROUND. ROCK FELL FROM ROOF HITTING ON HAND.","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"169054","DOCUMENT_NO":"220040680045","ACCIDENT_DT":"02/23/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"SCOOP WAS DIPPING UP A PIECE OF ROCK WHEN IT TWISTED STRIKING HIS FOOT WHICH TURNED HIS ANKLE.","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"207810","DOCUMENT_NO":"220040300020","ACCIDENT_DT":"01/13/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"13","NARRATIVE":"ROCK GOT STUCK IN SHUTTLE CAR WHILE BREAKING IT UP, IT FELL OUT OF CAR STRIKING HIS FOOT.","sourceDate":"2004-01-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-07-25","lastDate":"2006-07-25","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":400,"firstDate":"2000-01-19","lastDate":"2006-06-21","metrics":{"ss":134,"delinquent":388,"recentRows":0,"paidPenalty":48326,"proposedPenalty":49026,"currentAssessment":48326},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1035843","VIOLATION_NO":"7427953","ISSUE_DT":"06/21/2006","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"350.00","CURRENT_ASSESSMENT_AMT":"350.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"1035842","VIOLATION_NO":"7427952","ISSUE_DT":"06/21/2006","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"1035841","VIOLATION_NO":"7427951","ISSUE_DT":"06/21/2006","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"1035840","VIOLATION_NO":"7427950","ISSUE_DT":"06/21/2006","CFR_STANDARD_CD":"75.204(f)(7)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"1035839","VIOLATION_NO":"7427949","ISSUE_DT":"06/21/2006","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"1035847","VIOLATION_NO":"7435873","ISSUE_DT":"05/12/2006","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"191.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-12"},{"SOURCE_ROW_NUMBER":"1035846","VIOLATION_NO":"7435872","ISSUE_DT":"05/12/2006","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"191.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-12"},{"SOURCE_ROW_NUMBER":"1035845","VIOLATION_NO":"7435871","ISSUE_DT":"05/11/2006","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2700.00","CURRENT_ASSESSMENT_AMT":"2000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-11"},{"SOURCE_ROW_NUMBER":"1035844","VIOLATION_NO":"7435870","ISSUE_DT":"05/11/2006","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-11"},{"SOURCE_ROW_NUMBER":"1035838","VIOLATION_NO":"7426385","ISSUE_DT":"05/01/2006","CFR_STANDARD_CD":"75.1907(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-01"},{"SOURCE_ROW_NUMBER":"1035837","VIOLATION_NO":"7426384","ISSUE_DT":"05/01/2006","CFR_STANDARD_CD":"75.605","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-01"},{"SOURCE_ROW_NUMBER":"1035836","VIOLATION_NO":"7426379","ISSUE_DT":"04/20/2006","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"203.00","CURRENT_ASSESSMENT_AMT":"203.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2,"firstDate":"2001-07-16","lastDate":"2007-08-24","metrics":{"appeals":0,"decisions":2,"recentRows":0,"decisionPenalty":2113,"originalPenalty":2813},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"9107","VIOLATION_NO":"7435871","DOCKET_NO":"KENT 2007-61","DECISION_DT":"08/24/2007","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2700.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2007-08-24"},{"SOURCE_ROW_NUMBER":"471305","VIOLATION_NO":"7374564","DOCKET_NO":"KENT20010236","DECISION_DT":"07/16/2001","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"113.00","DECISION_PENALTY_AMT":"113.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2001-07-16"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1033,"firstDate":"2000-01-19","lastDate":"2008-01-03","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":49,"validSamples":984,"maxConcentration":4.684,"concentrationTotal":436.337},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1176310","CASS_NUM":"50925149","SMP_TAKEN_DT":"1/3/2008","CONC":".215","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-01-03"},{"SOURCE_ROW_NUMBER":"555159","CASS_NUM":"50838463","SMP_TAKEN_DT":"6/30/2006","CONC":".258","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-30"},{"SOURCE_ROW_NUMBER":"157853","CASS_NUM":"50838479","SMP_TAKEN_DT":"6/29/2006","CONC":".205","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-29"},{"SOURCE_ROW_NUMBER":"81691","CASS_NUM":"50838483","SMP_TAKEN_DT":"6/28/2006","CONC":".23","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-28"},{"SOURCE_ROW_NUMBER":"1409486","CASS_NUM":"50838501","SMP_TAKEN_DT":"6/27/2006","CONC":".276","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"564535","CASS_NUM":"50838470","SMP_TAKEN_DT":"6/26/2006","CONC":".092","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"1234183","CASS_NUM":"57578735","SMP_TAKEN_DT":"4/24/2006","CONC":".618","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-04-24"},{"SOURCE_ROW_NUMBER":"990543","CASS_NUM":"57578691","SMP_TAKEN_DT":"4/24/2006","CONC":".694","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-04-24"},{"SOURCE_ROW_NUMBER":"577931","CASS_NUM":"57578727","SMP_TAKEN_DT":"4/24/2006","CONC":".871","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-04-24"},{"SOURCE_ROW_NUMBER":"527792","CASS_NUM":"57578703","SMP_TAKEN_DT":"4/24/2006","CONC":".386","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-04-24"},{"SOURCE_ROW_NUMBER":"317106","CASS_NUM":"57578737","SMP_TAKEN_DT":"4/24/2006","CONC":".028","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-04-24"},{"SOURCE_ROW_NUMBER":"306570","CASS_NUM":"57578705","SMP_TAKEN_DT":"4/24/2006","CONC":".46","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-04-24"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":7,"firstDate":"2000-11-27","lastDate":"2005-01-04","metrics":{"linkedIssuances":7},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1,"firstDate":"2006-05-11","lastDate":"2006-05-11","metrics":{"decisions":1,"ssChanged":0,"recentRows":0,"decisionPenalty":2000,"proposedPenalty":2700},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"397785","CITATION_NO":"7435871","CITATION_ISSUE_DT":"05/11/2006","DOCKET_NO":"KENT 2007-61","DECISION_DT":"08/24/2007","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2700.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2006-05-11"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1992-07-01","lastDate":"1997-06-30","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":135,"firstDate":"2000-01-04","lastDate":"2006-04-06","metrics":{"inspectors":167,"recentRows":0,"onSiteHours":2542.25,"inspectionHours":3788.25,"inspectionSamples":27},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"585607","EVENT_NO":"4193109","INSPECTION_BEGIN_DT":"04/06/2006","INSPECTION_END_DT":"06/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"122.5","SUM_TOTAL_ON_SITE_HOURS":"79","sourceDate":"2006-04-06"},{"SOURCE_ROW_NUMBER":"842310","EVENT_NO":"4179170","INSPECTION_BEGIN_DT":"02/27/2006","INSPECTION_END_DT":"02/27/2006","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2006-02-27"},{"SOURCE_ROW_NUMBER":"19710","EVENT_NO":"4179166","INSPECTION_BEGIN_DT":"01/03/2006","INSPECTION_END_DT":"03/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"87.5","SUM_TOTAL_ON_SITE_HOURS":"71","sourceDate":"2006-01-03"},{"SOURCE_ROW_NUMBER":"905093","EVENT_NO":"4179163","INSPECTION_BEGIN_DT":"11/07/2005","INSPECTION_END_DT":"12/22/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"117.5","SUM_TOTAL_ON_SITE_HOURS":"94","sourceDate":"2005-11-07"},{"SOURCE_ROW_NUMBER":"990964","EVENT_NO":"4179216","INSPECTION_BEGIN_DT":"06/30/2005","INSPECTION_END_DT":"09/29/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"114.25","SUM_TOTAL_ON_SITE_HOURS":"80.5","sourceDate":"2005-06-30"},{"SOURCE_ROW_NUMBER":"612671","EVENT_NO":"4179210","INSPECTION_BEGIN_DT":"04/12/2005","INSPECTION_END_DT":"06/28/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"97.5","SUM_TOTAL_ON_SITE_HOURS":"75.5","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"134758","EVENT_NO":"4179203","INSPECTION_BEGIN_DT":"03/23/2005","INSPECTION_END_DT":"03/28/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2005-03-23"},{"SOURCE_ROW_NUMBER":"865618","EVENT_NO":"4179201","INSPECTION_BEGIN_DT":"03/14/2005","INSPECTION_END_DT":"03/16/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2005-03-14"},{"SOURCE_ROW_NUMBER":"842394","EVENT_NO":"4178146","INSPECTION_BEGIN_DT":"03/01/2005","INSPECTION_END_DT":"03/02/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2005-03-01"},{"SOURCE_ROW_NUMBER":"250864","EVENT_NO":"4184058","INSPECTION_BEGIN_DT":"01/24/2005","INSPECTION_END_DT":"02/01/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2005-01-24"},{"SOURCE_ROW_NUMBER":"259946","EVENT_NO":"4184057","INSPECTION_BEGIN_DT":"01/10/2005","INSPECTION_END_DT":"02/22/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"114","SUM_TOTAL_ON_SITE_HOURS":"76","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"966875","EVENT_NO":"4184055","INSPECTION_BEGIN_DT":"11/22/2004","INSPECTION_END_DT":"02/23/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2004-11-22"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":54,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q3":{"hours":1475,"employees":21,"production":1633},"2006-Q2":{"hours":15370,"employees":21,"production":30233},"2006-Q1":{"hours":16456,"employees":23,"production":37932},"2005-Q4":{"hours":15737,"employees":26,"production":35306},"2005-Q3":{"hours":16590,"employees":31,"production":33764},"2005-Q2":{"hours":17281,"employees":28,"production":31865},"2005-Q1":{"hours":15115,"employees":27,"production":30593},"2004-Q4":{"hours":16901,"employees":26,"production":29621},"2004-Q3":{"hours":16768,"employees":29,"production":34937},"2004-Q2":{"hours":16428,"employees":25,"production":39782},"2004-Q1":{"hours":16224,"employees":28,"production":42867},"2003-Q4":{"hours":15196,"employees":25,"production":29594}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":60994,"employees":25,"production":171334},"2001":{"hours":64729,"employees":25,"production":165644},"2002":{"hours":64140,"employees":26,"production":172732},"2003":{"hours":62973,"employees":26,"production":158593},"2004":{"hours":66321,"employees":27,"production":147207},"2005":{"hours":64723,"employees":28,"production":131528},"2006":{"hours":33301,"employees":22,"production":69798}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":41,"firstDate":"2000-01-25","lastDate":"2005-12-20","metrics":{"recentRows":0,"doseOver100":7,"actDoseTotal":2853,"pelDoseTotal":2189},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"59101","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"60","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59100","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"81","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59099","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"71","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59098","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"TIMBERMAN","ACT_DOSE_85":"41","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59097","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"83","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59096","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"053","ACT_DOSE_85":"25","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59095","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"23","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59094","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"32","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59093","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"29","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59092","EVENT_NO":"4179163","SURVEY_DATE":"12/20/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"65","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2005-12-20"},{"SOURCE_ROW_NUMBER":"59086","EVENT_NO":"4164576","SURVEY_DATE":"10/04/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"19","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2002-10-04"},{"SOURCE_ROW_NUMBER":"59085","EVENT_NO":"4164576","SURVEY_DATE":"10/04/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2002-10-04"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":94,"firstDate":"2000-02-01","lastDate":"2006-04-24","metrics":{"recentRows":0,"voidSamples":13,"maxQuartzPct":24.1,"validSamples":81,"quartzPctTotal":979.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"160105","CASSETTE_NO":"57578727","SAMPLE_DT":"04/24/2006","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-24"},{"SOURCE_ROW_NUMBER":"2871","CASSETTE_NO":"57575845","SAMPLE_DT":"11/22/2005","QUARTZ_PCT":"10.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"163183","CASSETTE_NO":"57573770","SAMPLE_DT":"08/31/2005","QUARTZ_PCT":"07.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-31"},{"SOURCE_ROW_NUMBER":"16691","CASSETTE_NO":"57582762","SAMPLE_DT":"07/19/2005","QUARTZ_PCT":"13.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-07-19"},{"SOURCE_ROW_NUMBER":"93823","CASSETTE_NO":"57582045","SAMPLE_DT":"05/23/2005","QUARTZ_PCT":"08.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-05-23"},{"SOURCE_ROW_NUMBER":"141155","CASSETTE_NO":"57581781","SAMPLE_DT":"03/16/2005","QUARTZ_PCT":"24.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-03-16"},{"SOURCE_ROW_NUMBER":"121497","CASSETTE_NO":"57581790","SAMPLE_DT":"03/02/2005","QUARTZ_PCT":"13.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-03-02"},{"SOURCE_ROW_NUMBER":"125098","CASSETTE_NO":"50748078","SAMPLE_DT":"01/28/2005","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2005-01-28"},{"SOURCE_ROW_NUMBER":"41697","CASSETTE_NO":"57581119","SAMPLE_DT":"01/25/2005","QUARTZ_PCT":"09.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"72560","CASSETTE_NO":"57581422","SAMPLE_DT":"01/13/2005","QUARTZ_PCT":"20.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-13"},{"SOURCE_ROW_NUMBER":"27784","CASSETTE_NO":"57581439","SAMPLE_DT":"01/13/2005","QUARTZ_PCT":"22.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-13"},{"SOURCE_ROW_NUMBER":"13674","CASSETTE_NO":"50758400","SAMPLE_DT":"12/22/2004","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-12-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":401,"firstDate":"2000-01-19","lastDate":"2006-06-21","metrics":{"ss":134,"amountDue":48326,"contested":2,"amountPaid":48326,"recentRows":0,"section104d":1,"unterminated":0,"proposedPenalty":49026},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"878541","VIOLATION_NO":"7427953","VIOLATION_ISSUE_DT":"06/21/2006","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"6","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2006","PROPOSED_PENALTY":"350","AMOUNT_DUE":"350","AMOUNT_PAID":"350","CONTESTED_IND":"N","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"878540","VIOLATION_NO":"7427952","VIOLATION_ISSUE_DT":"06/21/2006","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2006","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"878539","VIOLATION_NO":"7427951","VIOLATION_ISSUE_DT":"06/21/2006","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2006","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"878538","VIOLATION_NO":"7427950","VIOLATION_ISSUE_DT":"06/21/2006","SIG_SUB":"N","PART_SECTION":"75.204(f)(7)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"878537","VIOLATION_NO":"7427949","VIOLATION_ISSUE_DT":"06/21/2006","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2006","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"878545","VIOLATION_NO":"7435873","VIOLATION_ISSUE_DT":"05/12/2006","SIG_SUB":"Y","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/12/2006","PROPOSED_PENALTY":"191","AMOUNT_DUE":"191","AMOUNT_PAID":"191","CONTESTED_IND":"N","sourceDate":"2006-05-12"},{"SOURCE_ROW_NUMBER":"878544","VIOLATION_NO":"7435872","VIOLATION_ISSUE_DT":"05/12/2006","SIG_SUB":"Y","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2006","PROPOSED_PENALTY":"191","AMOUNT_DUE":"191","AMOUNT_PAID":"191","CONTESTED_IND":"N","sourceDate":"2006-05-12"},{"SOURCE_ROW_NUMBER":"878543","VIOLATION_NO":"7435871","VIOLATION_ISSUE_DT":"05/11/2006","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"05/15/2006","PROPOSED_PENALTY":"2700","AMOUNT_DUE":"2000","AMOUNT_PAID":"2000","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2007-61","sourceDate":"2006-05-11"},{"SOURCE_ROW_NUMBER":"878542","VIOLATION_NO":"7435870","VIOLATION_ISSUE_DT":"05/11/2006","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/12/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-05-11"},{"SOURCE_ROW_NUMBER":"878536","VIOLATION_NO":"7426385","VIOLATION_ISSUE_DT":"05/01/2006","SIG_SUB":"N","PART_SECTION":"75.1907(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/01/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-05-01"},{"SOURCE_ROW_NUMBER":"878535","VIOLATION_NO":"7426384","VIOLATION_ISSUE_DT":"05/01/2006","SIG_SUB":"N","PART_SECTION":"75.605","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/01/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-05-01"},{"SOURCE_ROW_NUMBER":"878534","VIOLATION_NO":"7426379","VIOLATION_ISSUE_DT":"04/20/2006","SIG_SUB":"Y","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2006","PROPOSED_PENALTY":"203","AMOUNT_DUE":"203","AMOUNT_PAID":"203","CONTESTED_IND":"N","sourceDate":"2006-04-20"}]}],"safety":{"href":"/api/v1/mines/1517260/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1517260/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":2},{"chapter":"I","heading":"Roof bolting.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.204","part":"75","subchapter":"O","subpart":"C","id":"75.204","citation":"30 CFR 75.204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Diesel-powered equipment intended for use in underground coal mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1907","part":"75","subchapter":"O","subpart":"T","id":"75.1907","citation":"30 CFR 75.1907","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Clamping of trailing cables to equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.605","part":"75","subchapter":"O","subpart":"G","id":"75.605","citation":"30 CFR 75.605","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1517260","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}