{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1516693","name":"Smith Fork Mine No 1","status":"Abandoned and Sealed","status_date":"2001-07-23","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Meta","operator_id":"P19831","operator_name":"Mc Coy Elkhorn Coal Corp","controller_id":"C13562","controller_name":"James River Coal Company","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.5767,"longitude":-82.4342},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":312},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1516693","name":"Smith Fork Mine No 1"},"operator":{"type":"operator","id":"P19831","name":"Mc Coy Elkhorn Coal Corp"},"controller":{"type":"controller","id":"C13562","name":"James River Coal Company"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C03360","name":"Dennis Allen  Ramey"},"object":{"type":"mine","id":"1516693","name":"Smith Fork Mine No 1"},"validFrom":"1987-09-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516693|C03360|1987-09-09|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1516693","name":"Smith Fork Mine No 1"},"validFrom":"1988-09-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516693|C13562|1988-09-28|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19167","name":"United Fuels Inc"},"object":{"type":"mine","id":"1516693","name":"Smith Fork Mine No 1"},"validFrom":"1989-08-01","validTo":"1992-04-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516693|P19167|1989-08-01|1992-04-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C03360","name":"Dennis Allen  Ramey"},"object":{"type":"operator","id":"P19167","name":"United Fuels Inc"},"validFrom":"1989-08-01","validTo":"1992-04-30","current":false,"derived":true,"evidenceMineId":"1516693","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516693|P19167|1989-08-01|C03360|1987-09-09|62611"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19831","name":"Mc Coy Elkhorn Coal Corp"},"object":{"type":"mine","id":"1516693","name":"Smith Fork Mine No 1"},"validFrom":"1992-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516693|P19831|1992-05-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P19831","name":"Mc Coy Elkhorn Coal Corp"},"validFrom":"1992-05-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1516693","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516693|P19831|1992-05-01|C13562|1988-09-28|90322"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":6,"firstDate":"2000-05-18","lastDate":"2000-11-14","metrics":{"daysLost":122,"injuries":5,"fatalities":0,"recentRows":0,"restrictedDays":12,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"44264","DOCUMENT_NO":"220003270033","ACCIDENT_DT":"11/14/2000","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"COAL RIB FELL STRIKING EE ON RIGHT ELBOW AND FOREARM CAUSING MINOR BRUISING.","sourceDate":"2000-11-14"},{"SOURCE_ROW_NUMBER":"130106","DOCUMENT_NO":"220002870019","ACCIDENT_DT":"09/18/2000","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"EE WAS USING A HAND HELD DISC GRINDER IT BECAME TANGLED IN HIS CLOTHING CAUSING IT TO STRIKE HIM ON THE RIGHT SIDE OF HIS HEAD AND EAR CAUSING LACERATIONS TO BOTH.","sourceDate":"2000-09-18"},{"SOURCE_ROW_NUMBER":"143237","DOCUMENT_NO":"220002870020","ACCIDENT_DT":"09/07/2000","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"HELPING MECHANIC PUT TOGETHER CONVEYER CHAIN ON MINER AND HIT 2ND FINGER OF LEFT HAND WITH HAMMER-FRACTURED FINGER.","sourceDate":"2000-09-07"},{"SOURCE_ROW_NUMBER":"117261","DOCUMENT_NO":"220002340118","ACCIDENT_DT":"08/10/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"STARTED TO LIFT TIMBER AND FELT PAIN IN GROIN AREA.","sourceDate":"2000-08-10"},{"SOURCE_ROW_NUMBER":"199066","DOCUMENT_NO":"220002070042","ACCIDENT_DT":"07/13/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE ROOF FALL OCCURRED IN #7 ENTRY, 6 X-CUTS INBY SURVEY STATION #4918; FALL WAS ABOUT 15' THICK, 18'L, 80'W. FALL FIRST CUT THE CABLE AND CRIBS AND 12X12\" TIMBERS WERE BEING SET FOR ADDITION AL SUPPORT WHEN IT FELL AGAIN, COVERING THE 14CM-9 JOY MINER.","sourceDate":"2000-07-13"},{"SOURCE_ROW_NUMBER":"138924","DOCUMENT_NO":"220001510202","ACCIDENT_DT":"05/18/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"120","NARRATIVE":"A PIECE OF DRAW ROCK FELL STRIKING EMPLOYEE ON RIGHT ANKLE.","sourceDate":"2000-05-18"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2001-07-23","lastDate":"2001-07-23","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":46,"firstDate":"2000-01-13","lastDate":"2001-01-25","metrics":{"ss":19,"delinquent":46,"recentRows":0,"paidPenalty":7683,"proposedPenalty":7683,"currentAssessment":7683},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"960311","VIOLATION_NO":"7374975","ISSUE_DT":"01/25/2001","CFR_STANDARD_CD":"75.312(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-01-25"},{"SOURCE_ROW_NUMBER":"960310","VIOLATION_NO":"7374974","ISSUE_DT":"01/25/2001","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"242.00","CURRENT_ASSESSMENT_AMT":"242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-01-25"},{"SOURCE_ROW_NUMBER":"960309","VIOLATION_NO":"7374973","ISSUE_DT":"01/23/2001","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"242.00","CURRENT_ASSESSMENT_AMT":"242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"960308","VIOLATION_NO":"7374972","ISSUE_DT":"01/23/2001","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"960307","VIOLATION_NO":"7374971","ISSUE_DT":"01/23/2001","CFR_STANDARD_CD":"75.208","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"242.00","CURRENT_ASSESSMENT_AMT":"242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"960306","VIOLATION_NO":"7374970","ISSUE_DT":"01/23/2001","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"960305","VIOLATION_NO":"7374962","ISSUE_DT":"01/04/2001","CFR_STANDARD_CD":"75.208","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"242.00","CURRENT_ASSESSMENT_AMT":"242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-01-04"},{"SOURCE_ROW_NUMBER":"960304","VIOLATION_NO":"7374961","ISSUE_DT":"01/04/2001","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-01-04"},{"SOURCE_ROW_NUMBER":"960303","VIOLATION_NO":"7374468","ISSUE_DT":"01/04/2001","CFR_STANDARD_CD":"75.1101-1(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-01-04"},{"SOURCE_ROW_NUMBER":"959165","VIOLATION_NO":"7374494","ISSUE_DT":"12/01/2000","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"475.00","CURRENT_ASSESSMENT_AMT":"475.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-12-01"},{"SOURCE_ROW_NUMBER":"959164","VIOLATION_NO":"7374493","ISSUE_DT":"12/01/2000","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"475.00","CURRENT_ASSESSMENT_AMT":"475.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-12-01"},{"SOURCE_ROW_NUMBER":"959163","VIOLATION_NO":"7374492","ISSUE_DT":"11/28/2000","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"475.00","CURRENT_ASSESSMENT_AMT":"475.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-28"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":151,"firstDate":"2000-01-05","lastDate":"2000-12-16","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":3,"validSamples":148,"maxConcentration":87.811,"concentrationTotal":160.155},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"715838","CASS_NUM":"50545224","SMP_TAKEN_DT":"12/16/2000","CONC":".46","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-16"},{"SOURCE_ROW_NUMBER":"456783","CASS_NUM":"50545263","SMP_TAKEN_DT":"12/16/2000","CONC":".516","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-16"},{"SOURCE_ROW_NUMBER":"653938","CASS_NUM":"50545272","SMP_TAKEN_DT":"12/15/2000","CONC":".96","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-15"},{"SOURCE_ROW_NUMBER":"487712","CASS_NUM":"50545240","SMP_TAKEN_DT":"12/15/2000","CONC":".47","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-15"},{"SOURCE_ROW_NUMBER":"203556","CASS_NUM":"50545201","SMP_TAKEN_DT":"12/15/2000","CONC":".715","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-15"},{"SOURCE_ROW_NUMBER":"101195","CASS_NUM":"50545259","SMP_TAKEN_DT":"12/15/2000","CONC":"1.535","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-15"},{"SOURCE_ROW_NUMBER":"1566136","CASS_NUM":"50545269","SMP_TAKEN_DT":"12/14/2000","CONC":".644","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-14"},{"SOURCE_ROW_NUMBER":"1029032","CASS_NUM":"50545238","SMP_TAKEN_DT":"12/14/2000","CONC":"1.046","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-14"},{"SOURCE_ROW_NUMBER":"977608","CASS_NUM":"50545260","SMP_TAKEN_DT":"12/14/2000","CONC":"1.418","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-14"},{"SOURCE_ROW_NUMBER":"14986","CASS_NUM":"50545261","SMP_TAKEN_DT":"12/14/2000","CONC":".518","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-14"},{"SOURCE_ROW_NUMBER":"1466135","CASS_NUM":"57298296","SMP_TAKEN_DT":"12/9/2000","CONC":".257","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-09"},{"SOURCE_ROW_NUMBER":"1427730","CASS_NUM":"57298270","SMP_TAKEN_DT":"12/9/2000","CONC":".249","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-09"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1989-08-01","lastDate":"1992-05-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":30,"firstDate":"2000-01-04","lastDate":"2001-07-16","metrics":{"inspectors":31,"recentRows":0,"onSiteHours":422,"inspectionHours":598.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"348963","EVENT_NO":"4163010","INSPECTION_BEGIN_DT":"07/16/2001","INSPECTION_END_DT":"08/03/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2001-07-16"},{"SOURCE_ROW_NUMBER":"306557","EVENT_NO":"4169527","INSPECTION_BEGIN_DT":"04/18/2001","INSPECTION_END_DT":"06/05/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2001-04-18"},{"SOURCE_ROW_NUMBER":"818405","EVENT_NO":"4165229","INSPECTION_BEGIN_DT":"02/27/2001","INSPECTION_END_DT":"02/28/2001","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2001-02-27"},{"SOURCE_ROW_NUMBER":"659841","EVENT_NO":"4169518","INSPECTION_BEGIN_DT":"01/31/2001","INSPECTION_END_DT":"02/08/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2001-01-31"},{"SOURCE_ROW_NUMBER":"957212","EVENT_NO":"4169511","INSPECTION_BEGIN_DT":"01/03/2001","INSPECTION_END_DT":"02/12/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2001-01-03"},{"SOURCE_ROW_NUMBER":"920743","EVENT_NO":"4169512","INSPECTION_BEGIN_DT":"01/03/2001","INSPECTION_END_DT":"02/12/2001","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"51","SUM_TOTAL_ON_SITE_HOURS":"40.5","sourceDate":"2001-01-03"},{"SOURCE_ROW_NUMBER":"751615","EVENT_NO":"4169503","INSPECTION_BEGIN_DT":"12/09/2000","INSPECTION_END_DT":"12/09/2000","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2000-12-09"},{"SOURCE_ROW_NUMBER":"907910","EVENT_NO":"4168850","INSPECTION_BEGIN_DT":"12/02/2000","INSPECTION_END_DT":"12/02/2000","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2000-12-02"},{"SOURCE_ROW_NUMBER":"632118","EVENT_NO":"4165211","INSPECTION_BEGIN_DT":"11/27/2000","INSPECTION_END_DT":"12/04/2000","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2000-11-27"},{"SOURCE_ROW_NUMBER":"24340","EVENT_NO":"4168849","INSPECTION_BEGIN_DT":"11/22/2000","INSPECTION_END_DT":"12/04/2000","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"40.5","SUM_TOTAL_ON_SITE_HOURS":"25","sourceDate":"2000-11-22"},{"SOURCE_ROW_NUMBER":"209518","EVENT_NO":"4168834","INSPECTION_BEGIN_DT":"10/14/2000","INSPECTION_END_DT":"10/14/2000","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2000-10-14"},{"SOURCE_ROW_NUMBER":"11211","EVENT_NO":"4168829","INSPECTION_BEGIN_DT":"10/07/2000","INSPECTION_END_DT":"11/14/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2000-10-07"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":9,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001-Q3":{"hours":0,"employees":0,"production":0},"2001-Q2":{"hours":0,"employees":0,"production":0},"2001-Q1":{"hours":10843,"employees":39,"production":58776},"2000-Q4":{"hours":24186,"employees":41,"production":153609},"2000-Q3":{"hours":24678,"employees":43,"production":140802},"2000-Q2":{"hours":27941,"employees":42,"production":193237},"2000-Q1":{"hours":28657,"employees":41,"production":166723}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":105462,"employees":43,"production":654371},"2001":{"hours":10843,"employees":39,"production":58776}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2000-01-05","lastDate":"2001-02-01","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":584,"pelDoseTotal":464},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"54292","EVENT_NO":"4169518","SURVEY_DATE":"02/01/2001","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"10","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2001-02-01"},{"SOURCE_ROW_NUMBER":"54291","EVENT_NO":"4169518","SURVEY_DATE":"02/01/2001","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"18","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2001-02-01"},{"SOURCE_ROW_NUMBER":"54290","EVENT_NO":"4169518","SURVEY_DATE":"02/01/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"23","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2001-02-01"},{"SOURCE_ROW_NUMBER":"54289","EVENT_NO":"4169518","SURVEY_DATE":"02/01/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"32","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2001-02-01"},{"SOURCE_ROW_NUMBER":"54288","EVENT_NO":"4169518","SURVEY_DATE":"02/01/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"118","PEL_DOSE_90":"110","SURVEY_TYPE":"I","sourceDate":"2001-02-01"},{"SOURCE_ROW_NUMBER":"54297","EVENT_NO":"6144514","SURVEY_DATE":"01/05/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"32","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2000-01-05"},{"SOURCE_ROW_NUMBER":"54296","EVENT_NO":"6144514","SURVEY_DATE":"01/05/2000","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"91","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2000-01-05"},{"SOURCE_ROW_NUMBER":"54295","EVENT_NO":"6144514","SURVEY_DATE":"01/05/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"73","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2000-01-05"},{"SOURCE_ROW_NUMBER":"54294","EVENT_NO":"6144514","SURVEY_DATE":"01/05/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"38","MANUFACTURER_CD":"058","ACT_DOSE_85":"62","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2000-01-05"},{"SOURCE_ROW_NUMBER":"54293","EVENT_NO":"6144514","SURVEY_DATE":"01/05/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"125","PEL_DOSE_90":"105","SURVEY_TYPE":"I","sourceDate":"2000-01-05"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":7,"firstDate":"2000-01-06","lastDate":"2000-10-14","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":6.2,"validSamples":7,"quartzPctTotal":33.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"118221","CASSETTE_NO":"57297652","SAMPLE_DT":"10/14/2000","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-14"},{"SOURCE_ROW_NUMBER":"127055","CASSETTE_NO":"57297621","SAMPLE_DT":"10/06/2000","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-06"},{"SOURCE_ROW_NUMBER":"12223","CASSETTE_NO":"57297607","SAMPLE_DT":"10/06/2000","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-06"},{"SOURCE_ROW_NUMBER":"79445","CASSETTE_NO":"50508627","SAMPLE_DT":"06/05/2000","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-06-05"},{"SOURCE_ROW_NUMBER":"152129","CASSETTE_NO":"57259933","SAMPLE_DT":"01/06/2000","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-01-06"},{"SOURCE_ROW_NUMBER":"151038","CASSETTE_NO":"57259519","SAMPLE_DT":"01/06/2000","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-01-06"},{"SOURCE_ROW_NUMBER":"105802","CASSETTE_NO":"57260043","SAMPLE_DT":"01/06/2000","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-01-06"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":46,"firstDate":"2000-01-13","lastDate":"2001-01-25","metrics":{"ss":19,"amountDue":7683,"contested":0,"amountPaid":7683,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":7683},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"846130","VIOLATION_NO":"7374975","VIOLATION_ISSUE_DT":"01/25/2001","SIG_SUB":"N","PART_SECTION":"75.312(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"8","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/29/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-01-25"},{"SOURCE_ROW_NUMBER":"846129","VIOLATION_NO":"7374974","VIOLATION_ISSUE_DT":"01/25/2001","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2001","PROPOSED_PENALTY":"242","AMOUNT_DUE":"242","AMOUNT_PAID":"242","CONTESTED_IND":"N","sourceDate":"2001-01-25"},{"SOURCE_ROW_NUMBER":"846128","VIOLATION_NO":"7374973","VIOLATION_ISSUE_DT":"01/23/2001","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2001","PROPOSED_PENALTY":"242","AMOUNT_DUE":"242","AMOUNT_PAID":"242","CONTESTED_IND":"N","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"846127","VIOLATION_NO":"7374972","VIOLATION_ISSUE_DT":"01/23/2001","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/25/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"846126","VIOLATION_NO":"7374971","VIOLATION_ISSUE_DT":"01/23/2001","SIG_SUB":"Y","PART_SECTION":"75.208","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2001","PROPOSED_PENALTY":"242","AMOUNT_DUE":"242","AMOUNT_PAID":"242","CONTESTED_IND":"N","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"846125","VIOLATION_NO":"7374970","VIOLATION_ISSUE_DT":"01/23/2001","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"846124","VIOLATION_NO":"7374962","VIOLATION_ISSUE_DT":"01/04/2001","SIG_SUB":"Y","PART_SECTION":"75.208","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/04/2001","PROPOSED_PENALTY":"242","AMOUNT_DUE":"242","AMOUNT_PAID":"242","CONTESTED_IND":"N","sourceDate":"2001-01-04"},{"SOURCE_ROW_NUMBER":"846123","VIOLATION_NO":"7374961","VIOLATION_ISSUE_DT":"01/04/2001","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-01-04"},{"SOURCE_ROW_NUMBER":"846122","VIOLATION_NO":"7374468","VIOLATION_ISSUE_DT":"01/04/2001","SIG_SUB":"N","PART_SECTION":"75.1101-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/04/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-01-04"},{"SOURCE_ROW_NUMBER":"846167","VIOLATION_NO":"7374494","VIOLATION_ISSUE_DT":"12/01/2000","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2000","PROPOSED_PENALTY":"475","AMOUNT_DUE":"475","AMOUNT_PAID":"475","CONTESTED_IND":"N","sourceDate":"2000-12-01"},{"SOURCE_ROW_NUMBER":"846166","VIOLATION_NO":"7374493","VIOLATION_ISSUE_DT":"12/01/2000","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2000","PROPOSED_PENALTY":"475","AMOUNT_DUE":"475","AMOUNT_PAID":"475","CONTESTED_IND":"N","sourceDate":"2000-12-01"},{"SOURCE_ROW_NUMBER":"846165","VIOLATION_NO":"7374492","VIOLATION_ISSUE_DT":"11/28/2000","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/29/2000","PROPOSED_PENALTY":"475","AMOUNT_DUE":"475","AMOUNT_PAID":"475","CONTESTED_IND":"N","sourceDate":"2000-11-28"}]}],"safety":{"href":"/api/v1/mines/1516693/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1516693/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Main mine fan examinations and records.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.312","part":"75","subchapter":"O","subpart":"D","id":"75.312","citation":"30 CFR 75.312","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","heading":"Warning devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.208","part":"75","subchapter":"O","subpart":"C","id":"75.208","citation":"30 CFR 75.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Deluge-type water spray systems.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1101-1","part":"75","subchapter":"O","subpart":"L","id":"75.1101-1","citation":"30 CFR 75.1101-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":3}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1516693","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}