{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1516599","name":"Burnwell Energy","status":"Abandoned","status_date":"2006-12-12","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Goody","operator_id":"P22248","operator_name":"Road Fork Development Company Inc","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.611944,"longitude":-82.206944},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":3442},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"operator":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc"},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12655","name":"Salmons Carlos"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"1980-02-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|C12655|1980-02-26|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12467","name":"Sharon  Preece et al"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"1986-01-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|C12467|1986-01-16|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P10466","name":"C & R Coal Company"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"1989-04-01","validTo":"1990-05-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P10466|1989-04-01|1990-05-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12655","name":"Salmons Carlos"},"object":{"type":"operator","id":"P10466","name":"C & R Coal Company"},"validFrom":"1989-04-01","validTo":"1990-05-29","current":false,"derived":true,"evidenceMineId":"1516599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P10466|1989-04-01|C12655|1980-02-26|87608"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17795","name":"Preece Energy Inc"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"1990-05-30","validTo":"1993-07-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P17795|1990-05-30|1993-07-26"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12467","name":"Sharon  Preece et al"},"object":{"type":"operator","id":"P17795","name":"Preece Energy Inc"},"validFrom":"1990-05-30","validTo":"1993-07-26","current":false,"derived":true,"evidenceMineId":"1516599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P17795|1990-05-30|C12467|1986-01-16|86960"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14849","name":"Dwight D  McCoy"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"1992-12-21","validTo":"1994-09-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|C14849|1992-12-21|1994-09-14"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"1993-01-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|C02508|1993-01-01|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22354","name":"Carbon Processors Inc"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"1993-07-27","validTo":"1994-01-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P22354|1993-07-27|1994-01-27"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14849","name":"Dwight D  McCoy"},"object":{"type":"operator","id":"P22354","name":"Carbon Processors Inc"},"validFrom":"1993-07-27","validTo":"1994-01-27","current":false,"derived":true,"evidenceMineId":"1516599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P22354|1993-07-27|C14849|1992-12-21|94056"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"1994-01-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P22248|1994-01-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc"},"validFrom":"1994-01-28","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"1516599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P22248|1994-01-28|C02508|1993-01-01|59302"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"1516599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P22248|1994-01-28|0041211|2011-06-01|1846"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"1516599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P22248|1994-01-28|0127923|2016-07-26|25111"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"1516599","name":"Burnwell Energy"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"1516599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516599|P22248|1994-01-28|0127321|2018-11-09|24746"}}],"coverage":{"historyRecords":7,"edgeCount":18,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":46,"firstDate":"2000-01-17","lastDate":"2006-10-31","metrics":{"daysLost":1753,"injuries":36,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"74298","DOCUMENT_NO":"220063180027","ACCIDENT_DT":"10/31/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"2","DAYS_LOST":"154","NARRATIVE":"While taking down a belt conveyor structure the structure fell prematurely throwing two employees to the ground 25 ft below.","sourceDate":"2006-10-31"},{"SOURCE_ROW_NUMBER":"18481","DOCUMENT_NO":"220063110026","ACCIDENT_DT":"10/31/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Dryer operator, Kiln operator,  Dry plant operator,  Fluid operator, Bed dryer operator","NO_INJURIES":"2","DAYS_LOST":"154","NARRATIVE":"While taking down a belt conveyor structure the structure fell prematurely throwing two employees to the ground 25 ft below.","sourceDate":"2006-10-31"},{"SOURCE_ROW_NUMBER":"186259","DOCUMENT_NO":"220061800058","ACCIDENT_DT":"06/20/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Member was pulling rail out of mine. Was pulling metal track tie from under the rail. His hand slipped and the tie cut his right index finger requiring stitches.","sourceDate":"2006-06-20"},{"SOURCE_ROW_NUMBER":"22818","DOCUMENT_NO":"220060240050","ACCIDENT_DT":"01/04/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured stated he and co-workers were supplying the roof bolter. He said he picked up the 42\" resin rebar and felt a pop in his back.","sourceDate":"2006-01-04"},{"SOURCE_ROW_NUMBER":"181973","DOCUMENT_NO":"220053180082","ACCIDENT_DT":"11/06/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Area had been mined 26 years prior. Area was 190' inby #3 portal. Hill seams were present and had additional support. Fall occurred just inby additional supports. Fall measured 35' x 20' x 5'.  Existing support was 48\" resin. Area has been rehabed.","sourceDate":"2005-11-06"},{"SOURCE_ROW_NUMBER":"74300","DOCUMENT_NO":"220053430040","ACCIDENT_DT":"10/07/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"12","NARRATIVE":"Employee was helping co-worker lift a piece of dried concrete out of the way where he was helping to install a belt drive.","sourceDate":"2005-10-07"},{"SOURCE_ROW_NUMBER":"125739","DOCUMENT_NO":"220052730047","ACCIDENT_DT":"09/26/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A ROOF FALL HAS OCCURRED IN THE #7 ENTRY 50' OUTBY THE FACE AT SPAD 9792. AREA OF FALL 60' X 19' X 35\" - 50\". TYPE SUPPORT 42\" RESIN BOLTS.","sourceDate":"2005-09-26"},{"SOURCE_ROW_NUMBER":"169020","DOCUMENT_NO":"220052510036","ACCIDENT_DT":"08/26/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"204","NARRATIVE":"Employee was installing a 42\"resin bolt in the roof. As he was pushing the bolt up the bolt bent & sprung out of the pot & the 8 x 8 plate cut his left forearm.","sourceDate":"2005-08-26"},{"SOURCE_ROW_NUMBER":"18482","DOCUMENT_NO":"220060870031","ACCIDENT_DT":"06/04/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof Fall occurred 1 x-cut inby suveryor station #9191 roof was support with 42\" resin bolts, fall measured 13' wide 10' thick, 30' long.","sourceDate":"2005-06-04"},{"SOURCE_ROW_NUMBER":"83058","DOCUMENT_NO":"220050870026","ACCIDENT_DT":"03/04/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"121","NARRATIVE":"Member was moving roof bolter up to install a row of bolts and twisted his left knee, resulting in a strained knee.","sourceDate":"2005-03-04"},{"SOURCE_ROW_NUMBER":"229318","DOCUMENT_NO":"220050410054","ACCIDENT_DT":"02/08/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"LW Propman, Propman helper, Move crew if LW, Move-up man, Jacksetter, Advanceman LW helper","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE WAS CLEANING OLD BELT ENTRY WITH A SCOOP TO SET A TAIL PIECE. AS EE WAS SCOOPING AN OLD BELT RAIL CAME INTO THE OPERATORS COMPARTMENT AND STRUCK EE IN THE RIGHT SIDE. EE WAS TAKEN TO LOCAL ER AND DIAGNOSED WITH A FRACTURED RIB.","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"237889","DOCUMENT_NO":"220041770019","ACCIDENT_DT":"06/18/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"43","NARRATIVE":"EE HAD MADE A BELT SPLICE AND WAS REMOVING THE OLD PIN FROM THE OLD SPLICE.  HE TOOK HIS SAFETY GLASSES OFF TO WIPE HIS EYES OFF WITH A RAG AND THEN HE FELT SOMETHING IN HIS RIGHT EYE.","sourceDate":"2004-06-18"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-12-12","lastDate":"2006-12-12","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":757,"firstDate":"2000-01-19","lastDate":"2006-12-01","metrics":{"ss":432,"delinquent":716,"recentRows":0,"paidPenalty":281782,"proposedPenalty":306900,"currentAssessment":284400},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"971205","VIOLATION_NO":"7431135","ISSUE_DT":"12/01/2006","CFR_STANDARD_CD":"77.1710(g)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-12-01"},{"SOURCE_ROW_NUMBER":"971206","VIOLATION_NO":"7431136","ISSUE_DT":"11/06/2006","CFR_STANDARD_CD":"48.31","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-11-06"},{"SOURCE_ROW_NUMBER":"969373","VIOLATION_NO":"7431142","ISSUE_DT":"09/07/2006","CFR_STANDARD_CD":"75.312(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"969372","VIOLATION_NO":"7431141","ISSUE_DT":"09/07/2006","CFR_STANDARD_CD":"75.310(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"969371","VIOLATION_NO":"7430700","ISSUE_DT":"09/07/2006","CFR_STANDARD_CD":"75.312(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"969370","VIOLATION_NO":"7430699","ISSUE_DT":"09/07/2006","CFR_STANDARD_CD":"75.312(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"969369","VIOLATION_NO":"7430698","ISSUE_DT":"09/07/2006","CFR_STANDARD_CD":"75.310(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"969368","VIOLATION_NO":"7430697","ISSUE_DT":"09/07/2006","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"968808","VIOLATION_NO":"7437765","ISSUE_DT":"05/24/2006","CFR_STANDARD_CD":"75.364(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-24"},{"SOURCE_ROW_NUMBER":"968807","VIOLATION_NO":"7437764","ISSUE_DT":"05/24/2006","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"375.00","CURRENT_ASSESSMENT_AMT":"375.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-24"},{"SOURCE_ROW_NUMBER":"968806","VIOLATION_NO":"7437763","ISSUE_DT":"05/24/2006","CFR_STANDARD_CD":"77.1109","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-24"},{"SOURCE_ROW_NUMBER":"968805","VIOLATION_NO":"7437762","ISSUE_DT":"05/24/2006","CFR_STANDARD_CD":"75.310(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-24"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":5,"firstDate":"2003-12-04","lastDate":"2006-12-13","metrics":{"appeals":0,"decisions":5,"recentRows":0,"decisionPenalty":27620,"originalPenalty":50120},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3504","VIOLATION_NO":"7411587","DOCKET_NO":"KENT 2005-93","DECISION_DT":"12/13/2006","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2006-12-13"},{"SOURCE_ROW_NUMBER":"3503","VIOLATION_NO":"7411586","DOCKET_NO":"KENT 2005-93","DECISION_DT":"12/13/2006","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2006-12-13"},{"SOURCE_ROW_NUMBER":"471797","VIOLATION_NO":"4507799","DOCKET_NO":"KENT20030301","DECISION_DT":"12/04/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"18000.00","DECISION_PENALTY_AMT":"9000.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2003-12-04"},{"SOURCE_ROW_NUMBER":"471019","VIOLATION_NO":"4507798","DOCKET_NO":"KENT20030301","DECISION_DT":"12/04/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"14000.00","DECISION_PENALTY_AMT":"9500.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2003-12-04"},{"SOURCE_ROW_NUMBER":"174000","VIOLATION_NO":"4507800","DOCKET_NO":"KENT20030301","DECISION_DT":"12/04/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"18000.00","DECISION_PENALTY_AMT":"9000.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2003-12-04"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":595,"firstDate":"2000-01-17","lastDate":"2006-02-08","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":29,"validSamples":566,"maxConcentration":4.85,"concentrationTotal":331.244},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1555201","CASS_NUM":"57583731","SMP_TAKEN_DT":"2/8/2006","CONC":".136","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SECTION FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"1527292","CASS_NUM":"57583700","SMP_TAKEN_DT":"2/8/2006","CONC":".576","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"1402845","CASS_NUM":"57583736","SMP_TAKEN_DT":"2/8/2006","CONC":".501","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"1114954","CASS_NUM":"57583774","SMP_TAKEN_DT":"2/8/2006","CONC":".426","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"927963","CASS_NUM":"57583775","SMP_TAKEN_DT":"2/8/2006","CONC":".148","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"742154","CASS_NUM":"57583811","SMP_TAKEN_DT":"2/8/2006","CONC":"1.224","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"665721","CASS_NUM":"50814260","SMP_TAKEN_DT":"1/27/2006","CONC":".004","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-01-27"},{"SOURCE_ROW_NUMBER":"61242","CASS_NUM":"50814288","SMP_TAKEN_DT":"1/27/2006","CONC":".336","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-01-27"},{"SOURCE_ROW_NUMBER":"1545053","CASS_NUM":"50814273","SMP_TAKEN_DT":"1/26/2006","CONC":".231","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-01-26"},{"SOURCE_ROW_NUMBER":"694044","CASS_NUM":"50814218","SMP_TAKEN_DT":"1/26/2006","CONC":".146","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-01-26"},{"SOURCE_ROW_NUMBER":"1107726","CASS_NUM":"50814243","SMP_TAKEN_DT":"1/25/2006","CONC":".064","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-01-25"},{"SOURCE_ROW_NUMBER":"1595043","CASS_NUM":"57580603","SMP_TAKEN_DT":"12/9/2005","CONC":".176","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-12-09"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":9,"firstDate":"2001-05-02","lastDate":"2004-05-20","metrics":{"linkedIssuances":9},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":5,"firstDate":"2002-10-09","lastDate":"2004-11-08","metrics":{"decisions":5,"ssChanged":0,"recentRows":0,"decisionPenalty":27620,"proposedPenalty":50120},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1641","CITATION_NO":"7411587","CITATION_ISSUE_DT":"11/08/2004","DOCKET_NO":"KENT 2005-93","DECISION_DT":"12/13/2006","CFR_STANDARD_CODE":"75.342(a)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","sourceDate":"2004-11-08"},{"SOURCE_ROW_NUMBER":"1640","CITATION_NO":"7411586","CITATION_ISSUE_DT":"11/08/2004","DOCKET_NO":"KENT 2005-93","DECISION_DT":"12/13/2006","CFR_STANDARD_CODE":"75.342(a)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","sourceDate":"2004-11-08"},{"SOURCE_ROW_NUMBER":"225809","CITATION_NO":"4507800","CITATION_ISSUE_DT":"10/09/2002","DOCKET_NO":"KENT20030301","DECISION_DT":"12/04/2003","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"18000.00","DECISION_PENALTY_AMT":"9000.00","sourceDate":"2002-10-09"},{"SOURCE_ROW_NUMBER":"112649","CITATION_NO":"4507798","CITATION_ISSUE_DT":"10/09/2002","DOCKET_NO":"KENT20030301","DECISION_DT":"12/04/2003","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"14000.00","DECISION_PENALTY_AMT":"9500.00","sourceDate":"2002-10-09"},{"SOURCE_ROW_NUMBER":"12","CITATION_NO":"4507799","CITATION_ISSUE_DT":"10/09/2002","DOCKET_NO":"KENT20030301","DECISION_DT":"12/04/2003","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"18000.00","DECISION_PENALTY_AMT":"9000.00","sourceDate":"2002-10-09"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":793,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":151,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":7,"firstDate":"1989-04-01","lastDate":"1994-01-28","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":126,"firstDate":"2000-01-19","lastDate":"2006-11-06","metrics":{"inspectors":166,"recentRows":0,"onSiteHours":2926.75,"inspectionHours":4276.5,"inspectionSamples":6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"84468","EVENT_NO":"4173402","INSPECTION_BEGIN_DT":"11/06/2006","INSPECTION_END_DT":"11/08/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2006-11-06"},{"SOURCE_ROW_NUMBER":"289670","EVENT_NO":"4173401","INSPECTION_BEGIN_DT":"10/31/2006","INSPECTION_END_DT":"12/08/2006","ACTIVITY_CODE":"E07","ACTIVITY":"Non-Fatal Accident Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"43","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2006-10-31"},{"SOURCE_ROW_NUMBER":"16800","EVENT_NO":"4173199","INSPECTION_BEGIN_DT":"10/19/2006","INSPECTION_END_DT":"10/19/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2006-10-19"},{"SOURCE_ROW_NUMBER":"759429","EVENT_NO":"4172894","INSPECTION_BEGIN_DT":"07/03/2006","INSPECTION_END_DT":"09/21/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"34.5","SUM_TOTAL_ON_SITE_HOURS":"22.25","sourceDate":"2006-07-03"},{"SOURCE_ROW_NUMBER":"360966","EVENT_NO":"4172749","INSPECTION_BEGIN_DT":"04/18/2006","INSPECTION_END_DT":"06/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"46.25","SUM_TOTAL_ON_SITE_HOURS":"32.25","sourceDate":"2006-04-18"},{"SOURCE_ROW_NUMBER":"742989","EVENT_NO":"4172940","INSPECTION_BEGIN_DT":"03/24/2006","INSPECTION_END_DT":"03/24/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2006-03-24"},{"SOURCE_ROW_NUMBER":"348526","EVENT_NO":"4173158","INSPECTION_BEGIN_DT":"01/09/2006","INSPECTION_END_DT":"03/15/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"98.5","SUM_TOTAL_ON_SITE_HOURS":"68","sourceDate":"2006-01-09"},{"SOURCE_ROW_NUMBER":"82979","EVENT_NO":"4172877","INSPECTION_BEGIN_DT":"01/03/2006","INSPECTION_END_DT":"01/03/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2006-01-03"},{"SOURCE_ROW_NUMBER":"66393","EVENT_NO":"4173154","INSPECTION_BEGIN_DT":"11/07/2005","INSPECTION_END_DT":"11/07/2005","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2005-11-07"},{"SOURCE_ROW_NUMBER":"749675","EVENT_NO":"4172798","INSPECTION_BEGIN_DT":"10/04/2005","INSPECTION_END_DT":"12/21/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"141.5","SUM_TOTAL_ON_SITE_HOURS":"96.25","sourceDate":"2005-10-04"},{"SOURCE_ROW_NUMBER":"1012765","EVENT_NO":"4173004","INSPECTION_BEGIN_DT":"09/26/2005","INSPECTION_END_DT":"09/26/2005","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2005-09-26"},{"SOURCE_ROW_NUMBER":"692495","EVENT_NO":"4172920","INSPECTION_BEGIN_DT":"07/01/2005","INSPECTION_END_DT":"09/13/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"106.5","SUM_TOTAL_ON_SITE_HOURS":"76.5","sourceDate":"2005-07-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":72,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q4":{"hours":0,"employees":0,"production":0},"2006-Q3":{"hours":16,"employees":1,"production":0},"2006-Q2":{"hours":94,"employees":1,"production":696},"2006-Q1":{"hours":17477,"employees":32,"production":63197},"2005-Q4":{"hours":18819,"employees":31,"production":81493},"2005-Q3":{"hours":20106,"employees":34,"production":95059},"2005-Q2":{"hours":24418,"employees":36,"production":92709},"2005-Q1":{"hours":22742,"employees":34,"production":137516},"2004-Q4":{"hours":23557,"employees":35,"production":75761},"2004-Q3":{"hours":23422,"employees":35,"production":76457},"2004-Q2":{"hours":23740,"employees":37,"production":96470},"2004-Q1":{"hours":24389,"employees":38,"production":90570}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":74003,"employees":30,"production":482071},"2001":{"hours":90923,"employees":38,"production":460637},"2002":{"hours":94224,"employees":40,"production":488511},"2003":{"hours":95208,"employees":38,"production":411069},"2004":{"hours":95108,"employees":36,"production":339258},"2005":{"hours":86085,"employees":34,"production":406777},"2006":{"hours":17587,"employees":13,"production":63893}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":44,"firstDate":"2001-04-16","lastDate":"2005-11-02","metrics":{"recentRows":0,"doseOver100":16,"actDoseTotal":4256,"pelDoseTotal":3342},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"54133","EVENT_NO":"4172798","SURVEY_DATE":"11/02/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"87","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"54132","EVENT_NO":"4172798","SURVEY_DATE":"11/02/2005","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"002","ACT_DOSE_85":"31","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"54131","EVENT_NO":"4172798","SURVEY_DATE":"11/02/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"67","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"54130","EVENT_NO":"4172798","SURVEY_DATE":"11/02/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"64","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"54129","EVENT_NO":"4172798","SURVEY_DATE":"11/02/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"141","PEL_DOSE_90":"125","SURVEY_TYPE":"I","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"54128","EVENT_NO":"4172481","SURVEY_DATE":"10/26/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"039","ACT_DOSE_85":"64","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2004-10-26"},{"SOURCE_ROW_NUMBER":"54127","EVENT_NO":"4172481","SURVEY_DATE":"10/26/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"098","ACT_DOSE_85":"77","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2004-10-26"},{"SOURCE_ROW_NUMBER":"54126","EVENT_NO":"4172481","SURVEY_DATE":"10/26/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"94","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2004-10-26"},{"SOURCE_ROW_NUMBER":"54125","EVENT_NO":"4172481","SURVEY_DATE":"10/26/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"75","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2004-10-26"},{"SOURCE_ROW_NUMBER":"54124","EVENT_NO":"4172481","SURVEY_DATE":"10/26/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"127","PEL_DOSE_90":"109","SURVEY_TYPE":"I","sourceDate":"2004-10-26"},{"SOURCE_ROW_NUMBER":"54123","EVENT_NO":"4172430","SURVEY_DATE":"01/20/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"94","PEL_DOSE_90":"82","SURVEY_TYPE":"I","sourceDate":"2004-01-20"},{"SOURCE_ROW_NUMBER":"54122","EVENT_NO":"4172430","SURVEY_DATE":"01/20/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"119","PEL_DOSE_90":"94","SURVEY_TYPE":"I","sourceDate":"2004-01-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":45,"firstDate":"2000-04-10","lastDate":"2006-02-08","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":21.7,"validSamples":45,"quartzPctTotal":276.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"88389","CASSETTE_NO":"57583811","SAMPLE_DT":"02/08/2006","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"61686","CASSETTE_NO":"57580677","SAMPLE_DT":"11/23/2005","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-11-23"},{"SOURCE_ROW_NUMBER":"104106","CASSETTE_NO":"50791418","SAMPLE_DT":"09/20/2005","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"61755","CASSETTE_NO":"57466195","SAMPLE_DT":"04/06/2005","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-04-06"},{"SOURCE_ROW_NUMBER":"117976","CASSETTE_NO":"57508232","SAMPLE_DT":"02/04/2005","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-02-04"},{"SOURCE_ROW_NUMBER":"30691","CASSETTE_NO":"57562309","SAMPLE_DT":"12/01/2004","QUARTZ_PCT":"06.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-12-01"},{"SOURCE_ROW_NUMBER":"92544","CASSETTE_NO":"57562248","SAMPLE_DT":"10/13/2004","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-10-13"},{"SOURCE_ROW_NUMBER":"52839","CASSETTE_NO":"57562196","SAMPLE_DT":"10/13/2004","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-10-13"},{"SOURCE_ROW_NUMBER":"18693","CASSETTE_NO":"57562416","SAMPLE_DT":"08/19/2004","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-08-19"},{"SOURCE_ROW_NUMBER":"83845","CASSETTE_NO":"57555290","SAMPLE_DT":"06/30/2004","QUARTZ_PCT":"03.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-30"},{"SOURCE_ROW_NUMBER":"132770","CASSETTE_NO":"57544450","SAMPLE_DT":"01/07/2004","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-07"},{"SOURCE_ROW_NUMBER":"128814","CASSETTE_NO":"57457767","SAMPLE_DT":"11/12/2003","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-11-12"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":771,"firstDate":"2000-01-19","lastDate":"2006-12-01","metrics":{"ss":433,"amountDue":284400,"contested":5,"amountPaid":281782,"recentRows":0,"section104d":8,"unterminated":3,"proposedPenalty":306900},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"845363","VIOLATION_NO":"7431135","VIOLATION_ISSUE_DT":"12/01/2006","SIG_SUB":"Y","PART_SECTION":"77.1710(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Occurred","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/01/2006","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"154","CONTESTED_IND":"N","sourceDate":"2006-12-01"},{"SOURCE_ROW_NUMBER":"845364","VIOLATION_NO":"7431136","VIOLATION_ISSUE_DT":"11/06/2006","SIG_SUB":"N","PART_SECTION":"48.31","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/08/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-11-06"},{"SOURCE_ROW_NUMBER":"845362","VIOLATION_NO":"7431134","VIOLATION_ISSUE_DT":"10/31/2006","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"12/01/2006","CONTESTED_IND":"N","sourceDate":"2006-10-31"},{"SOURCE_ROW_NUMBER":"845089","VIOLATION_NO":"7431142","VIOLATION_ISSUE_DT":"09/07/2006","SIG_SUB":"N","PART_SECTION":"75.312(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/11/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"845088","VIOLATION_NO":"7431141","VIOLATION_ISSUE_DT":"09/07/2006","SIG_SUB":"N","PART_SECTION":"75.310(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/07/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"845087","VIOLATION_NO":"7430700","VIOLATION_ISSUE_DT":"09/07/2006","SIG_SUB":"N","PART_SECTION":"75.312(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/11/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"845086","VIOLATION_NO":"7430699","VIOLATION_ISSUE_DT":"09/07/2006","SIG_SUB":"N","PART_SECTION":"75.312(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/11/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"845085","VIOLATION_NO":"7430698","VIOLATION_ISSUE_DT":"09/07/2006","SIG_SUB":"N","PART_SECTION":"75.310(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/07/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"845084","VIOLATION_NO":"7430697","VIOLATION_ISSUE_DT":"09/07/2006","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/07/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"844980","VIOLATION_NO":"7437765","VIOLATION_ISSUE_DT":"05/24/2006","SIG_SUB":"N","PART_SECTION":"75.364(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/02/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-05-24"},{"SOURCE_ROW_NUMBER":"844979","VIOLATION_NO":"7437764","VIOLATION_ISSUE_DT":"05/24/2006","SIG_SUB":"Y","PART_SECTION":"77.1103(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/02/2006","PROPOSED_PENALTY":"375","AMOUNT_DUE":"375","AMOUNT_PAID":"375","CONTESTED_IND":"N","sourceDate":"2006-05-24"},{"SOURCE_ROW_NUMBER":"844978","VIOLATION_NO":"7437763","VIOLATION_ISSUE_DT":"05/24/2006","SIG_SUB":"N","PART_SECTION":"77.1109","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/02/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-05-24"}]}],"safety":{"href":"/api/v1/mines/1516599/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1516599/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Protective clothing; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1710","part":"77","subchapter":"O","subpart":"R","id":"77.1710","citation":"30 CFR 77.1710","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Hazard training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.31","part":"48","subchapter":"H","subpart":"B","id":"48.31","citation":"30 CFR 48.31","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Main mine fan examinations and records.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.312","part":"75","subchapter":"O","subpart":"D","id":"75.312","citation":"30 CFR 75.312","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":3},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1516599","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}