{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1516183","name":"Mine #9","status":"Abandoned and Sealed","status_date":"2005-06-23","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Virgie","operator_id":"P24269","operator_name":"Sister Bear Mining Inc","controller_id":"C13346","controller_name":"Stanley W Osborne","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.393888,"longitude":-82.611666},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":147},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1516183","name":"Mine #9"},"operator":{"type":"operator","id":"P24269","name":"Sister Bear Mining Inc"},"controller":{"type":"controller","id":"C13346","name":"Stanley W Osborne"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C06899","name":"Thomas B  Ratliff"},"object":{"type":"mine","id":"1516183","name":"Mine #9"},"validFrom":"1978-09-01","validTo":"2019-06-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|C06899|1978-09-01|2019-06-19"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C06337","name":"Thompson Benny"},"object":{"type":"mine","id":"1516183","name":"Mine #9"},"validFrom":"1981-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|C06337|1981-11-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P12847","name":"T & T Kentucky Coal Company Inc"},"object":{"type":"mine","id":"1516183","name":"Mine #9"},"validFrom":"1987-10-01","validTo":"1990-06-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|P12847|1987-10-01|1990-06-06"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06337","name":"Thompson Benny"},"object":{"type":"operator","id":"P12847","name":"T & T Kentucky Coal Company Inc"},"validFrom":"1987-10-01","validTo":"1990-06-06","current":false,"derived":true,"evidenceMineId":"1516183","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|P12847|1987-10-01|C06337|1981-11-01|71539"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P08667","name":"Landmark Mining Company Inc"},"object":{"type":"mine","id":"1516183","name":"Mine #9"},"validFrom":"1990-06-07","validTo":"2001-04-05","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|P08667|1990-06-07|2001-04-05"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06899","name":"Thomas B  Ratliff"},"object":{"type":"operator","id":"P08667","name":"Landmark Mining Company Inc"},"validFrom":"1990-06-07","validTo":"2001-04-05","current":false,"derived":true,"evidenceMineId":"1516183","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|P08667|1990-06-07|C06899|1978-09-01|73160"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13346","name":"Stanley W Osborne"},"object":{"type":"mine","id":"1516183","name":"Mine #9"},"validFrom":"1996-09-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|C13346|1996-09-04|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24269","name":"Sister Bear Mining Inc"},"object":{"type":"mine","id":"1516183","name":"Mine #9"},"validFrom":"2001-04-06","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|P24269|2001-04-06|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13346","name":"Stanley W Osborne"},"object":{"type":"operator","id":"P24269","name":"Sister Bear Mining Inc"},"validFrom":"2001-04-06","validTo":null,"current":true,"derived":true,"evidenceMineId":"1516183","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|P24269|2001-04-06|C13346|1996-09-04|89395"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0148921","name":"Kevin  Ratliff"},"object":{"type":"mine","id":"1516183","name":"Mine #9"},"validFrom":"2019-06-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|0148921|2019-06-20|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0148921","name":"Kevin  Ratliff"},"object":{"type":"operator","id":"P08667","name":"Landmark Mining Company Inc"},"validFrom":"2019-06-20","validTo":"2001-04-05","current":false,"derived":true,"evidenceMineId":"1516183","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516183|P08667|1990-06-07|0148921|2019-06-20|30461"}}],"coverage":{"historyRecords":4,"edgeCount":11,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":4,"firstDate":"2001-07-30","lastDate":"2001-10-05","metrics":{"daysLost":655,"injuries":4,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"91502","DOCUMENT_NO":"220012820062","ACCIDENT_DT":"10/05/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"A PIECE OF ROCK FELL AND HIT EE INT HE HEAD AN DNECK.","sourceDate":"2001-10-05"},{"SOURCE_ROW_NUMBER":"112980","DOCUMENT_NO":"220012850059","ACCIDENT_DT":"09/28/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Blaster, Shooter, Shotfirer, Explosive worker, Powder gang/monkey","NO_INJURIES":"1","DAYS_LOST":"187","NARRATIVE":"EMPLOYEE WAS MOVING BELT LINE (PULLING) AND FELT PAIN IN HIS BACK TO HIS FOOT.","sourceDate":"2001-09-28"},{"SOURCE_ROW_NUMBER":"147578","DOCUMENT_NO":"220012180015","ACCIDENT_DT":"07/30/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"229","NARRATIVE":"EE WAS RUNNING A GALLIS SINGLE HEAD ROOF BOLTER, DRILLING A BOOM HOLE. A PIECE OF ROCK FELL FROM BETWEEN THE BOLTS, STRIKING THE EE.","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"44258","DOCUMENT_NO":"220012120008","ACCIDENT_DT":"07/30/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between two or more moving objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"229","NARRATIVE":"EMPLOYEE PUT HAND BETWEEN BELT AND CAUGHT HIS ARM AND IT ROLLED HIS ARM AROUND A ROLLER.","sourceDate":"2001-07-30"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2005-06-23","lastDate":"2005-06-23","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":33,"firstDate":"2001-08-03","lastDate":"2002-02-05","metrics":{"ss":10,"delinquent":33,"recentRows":0,"paidPenalty":0,"proposedPenalty":2972,"currentAssessment":2972},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"945822","VIOLATION_NO":"7385823","ISSUE_DT":"02/05/2002","CFR_STANDARD_CD":"70.207(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-02-05"},{"SOURCE_ROW_NUMBER":"945821","VIOLATION_NO":"7385526","ISSUE_DT":"12/31/2001","CFR_STANDARD_CD":"70.208","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-31"},{"SOURCE_ROW_NUMBER":"1633230","VIOLATION_NO":"4493184","ISSUE_DT":"12/19/2001","CFR_STANDARD_CD":"75.1103-4(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"76.00","CURRENT_ASSESSMENT_AMT":"76.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-19"},{"SOURCE_ROW_NUMBER":"1633229","VIOLATION_NO":"4493183","ISSUE_DT":"12/19/2001","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"161.00","CURRENT_ASSESSMENT_AMT":"161.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-19"},{"SOURCE_ROW_NUMBER":"1633228","VIOLATION_NO":"4493182","ISSUE_DT":"12/19/2001","CFR_STANDARD_CD":"75.1702","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-19"},{"SOURCE_ROW_NUMBER":"1633227","VIOLATION_NO":"4493181","ISSUE_DT":"12/19/2001","CFR_STANDARD_CD":"75.1101-23(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-19"},{"SOURCE_ROW_NUMBER":"1633226","VIOLATION_NO":"4493180","ISSUE_DT":"12/18/2001","CFR_STANDARD_CD":"75.601","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"1633225","VIOLATION_NO":"4493179","ISSUE_DT":"12/18/2001","CFR_STANDARD_CD":"75.523-3(b)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"97.00","CURRENT_ASSESSMENT_AMT":"97.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"1633224","VIOLATION_NO":"4493178","ISSUE_DT":"12/18/2001","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"1633223","VIOLATION_NO":"4493177","ISSUE_DT":"12/18/2001","CFR_STANDARD_CD":"75.1100-2(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"1633222","VIOLATION_NO":"4493176","ISSUE_DT":"12/17/2001","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-17"},{"SOURCE_ROW_NUMBER":"1633221","VIOLATION_NO":"4493175","ISSUE_DT":"12/17/2001","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-12-17"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":34,"firstDate":"2001-07-31","lastDate":"2002-01-19","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":2,"validSamples":32,"maxConcentration":8.431,"concentrationTotal":35.025},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"705347","CASS_NUM":"50620580","SMP_TAKEN_DT":"1/19/2002","CONC":"1.145","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-19"},{"SOURCE_ROW_NUMBER":"843484","CASS_NUM":"50620565","SMP_TAKEN_DT":"1/18/2002","CONC":".422","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-18"},{"SOURCE_ROW_NUMBER":"1079557","CASS_NUM":"50620560","SMP_TAKEN_DT":"1/16/2002","CONC":".324","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-16"},{"SOURCE_ROW_NUMBER":"563777","CASS_NUM":"50620553","SMP_TAKEN_DT":"1/16/2002","CONC":"1.224","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-16"},{"SOURCE_ROW_NUMBER":"1364938","CASS_NUM":"50620534","SMP_TAKEN_DT":"1/15/2002","CONC":".383","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"1510421","CASS_NUM":"57324111","SMP_TAKEN_DT":"1/14/2002","CONC":".152","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-14"},{"SOURCE_ROW_NUMBER":"1148640","CASS_NUM":"57324132","SMP_TAKEN_DT":"1/14/2002","CONC":"2.01","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BLASTER/SHOOTER/SHOTFIRER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-14"},{"SOURCE_ROW_NUMBER":"1125167","CASS_NUM":"57324115","SMP_TAKEN_DT":"1/14/2002","CONC":"8.431","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"MALFUNCTIONING PUMP","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-14"},{"SOURCE_ROW_NUMBER":"1076563","CASS_NUM":"57324120","SMP_TAKEN_DT":"1/14/2002","CONC":".23","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-14"},{"SOURCE_ROW_NUMBER":"785695","CASS_NUM":"57324195","SMP_TAKEN_DT":"1/14/2002","CONC":".977","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-14"},{"SOURCE_ROW_NUMBER":"309185","CASS_NUM":"57324164","SMP_TAKEN_DT":"1/14/2002","CONC":".656","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-14"},{"SOURCE_ROW_NUMBER":"144537","CASS_NUM":"57324117","SMP_TAKEN_DT":"1/14/2002","CONC":".815","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-14"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"1987-10-01","lastDate":"2001-04-06","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":18,"firstDate":"2001-04-26","lastDate":"2005-06-23","metrics":{"inspectors":21,"recentRows":0,"onSiteHours":151.25,"inspectionHours":240.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"508880","EVENT_NO":"4179212","INSPECTION_BEGIN_DT":"06/23/2005","INSPECTION_END_DT":"06/23/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2005-06-23"},{"SOURCE_ROW_NUMBER":"271912","EVENT_NO":"4186200","INSPECTION_BEGIN_DT":"05/10/2004","INSPECTION_END_DT":"05/10/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2004-05-10"},{"SOURCE_ROW_NUMBER":"776657","EVENT_NO":"4186193","INSPECTION_BEGIN_DT":"03/29/2004","INSPECTION_END_DT":"03/29/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2004-03-29"},{"SOURCE_ROW_NUMBER":"21344","EVENT_NO":"4163423","INSPECTION_BEGIN_DT":"07/10/2002","INSPECTION_END_DT":"07/10/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2002-07-10"},{"SOURCE_ROW_NUMBER":"973676","EVENT_NO":"4163414","INSPECTION_BEGIN_DT":"04/16/2002","INSPECTION_END_DT":"04/16/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2002-04-16"},{"SOURCE_ROW_NUMBER":"327577","EVENT_NO":"6187958","INSPECTION_BEGIN_DT":"03/26/2002","INSPECTION_END_DT":"03/28/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2002-03-26"},{"SOURCE_ROW_NUMBER":"875995","EVENT_NO":"4164111","INSPECTION_BEGIN_DT":"02/25/2002","INSPECTION_END_DT":"02/25/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2002-02-25"},{"SOURCE_ROW_NUMBER":"319851","EVENT_NO":"4163686","INSPECTION_BEGIN_DT":"01/02/2002","INSPECTION_END_DT":"05/06/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"21.5","SUM_TOTAL_ON_SITE_HOURS":"10.75","sourceDate":"2002-01-02"},{"SOURCE_ROW_NUMBER":"775989","EVENT_NO":"4163685","INSPECTION_BEGIN_DT":"12/31/2001","INSPECTION_END_DT":"12/31/2001","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2001-12-31"},{"SOURCE_ROW_NUMBER":"1104163","EVENT_NO":"6187948","INSPECTION_BEGIN_DT":"12/13/2001","INSPECTION_END_DT":"12/21/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"43.5","SUM_TOTAL_ON_SITE_HOURS":"32.75","sourceDate":"2001-12-13"},{"SOURCE_ROW_NUMBER":"109028","EVENT_NO":"6187947","INSPECTION_BEGIN_DT":"12/10/2001","INSPECTION_END_DT":"12/13/2001","ACTIVITY_CODE":"BBF","ACTIVITY":"PART 50 AUDITS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2001-12-10"},{"SOURCE_ROW_NUMBER":"597309","EVENT_NO":"4163666","INSPECTION_BEGIN_DT":"11/19/2001","INSPECTION_END_DT":"12/06/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.75","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2001-11-19"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001-Q4":{"hours":9410,"employees":20,"production":16612},"2001-Q3":{"hours":9065,"employees":20,"production":19949},"2001-Q2":{"hours":1918,"employees":9,"production":2837}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":20393,"employees":16,"production":39398}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":6,"firstDate":"2001-11-26","lastDate":"2001-11-26","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":240,"pelDoseTotal":124},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"52751","EVENT_NO":"4163667","SURVEY_DATE":"11/26/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"58","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"52750","EVENT_NO":"4163667","SURVEY_DATE":"11/26/2001","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"19","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"52749","EVENT_NO":"4163667","SURVEY_DATE":"11/26/2001","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"28","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"52748","EVENT_NO":"4163667","SURVEY_DATE":"11/26/2001","OCCUPATION_CD_DESC":"BLASTER/SHOOTER/SHOTFIRER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"17","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"52747","EVENT_NO":"4163667","SURVEY_DATE":"11/26/2001","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"07","MANUFACTURER_CD":"067","ACT_DOSE_85":"18","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"52746","EVENT_NO":"4163667","SURVEY_DATE":"11/26/2001","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"100","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2001-11-26"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":4,"firstDate":"2001-09-26","lastDate":"2002-01-14","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":13.9,"validSamples":4,"quartzPctTotal":25.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"156170","CASSETTE_NO":"57324117","SAMPLE_DT":"01/14/2002","QUARTZ_PCT":"02.1","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-14"},{"SOURCE_ROW_NUMBER":"106158","CASSETTE_NO":"57324751","SAMPLE_DT":"11/26/2001","QUARTZ_PCT":"13.9","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"84315","CASSETTE_NO":"57324985","SAMPLE_DT":"09/26/2001","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-09-26"},{"SOURCE_ROW_NUMBER":"32762","CASSETTE_NO":"57325004","SAMPLE_DT":"09/26/2001","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-09-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":34,"firstDate":"2001-08-03","lastDate":"2002-02-05","metrics":{"ss":10,"amountDue":2972,"contested":0,"amountPaid":0,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":2972},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"835821","VIOLATION_NO":"7385823","VIOLATION_ISSUE_DT":"02/05/2002","SIG_SUB":"N","PART_SECTION":"70.207(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/05/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-02-05"},{"SOURCE_ROW_NUMBER":"835854","VIOLATION_NO":"7385526","VIOLATION_ISSUE_DT":"12/31/2001","SIG_SUB":"N","PART_SECTION":"70.208","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/31/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-31"},{"SOURCE_ROW_NUMBER":"835853","VIOLATION_NO":"4493184","VIOLATION_ISSUE_DT":"12/19/2001","SIG_SUB":"Y","PART_SECTION":"75.1103-4(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/20/2001","PROPOSED_PENALTY":"76","AMOUNT_DUE":"76","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-19"},{"SOURCE_ROW_NUMBER":"835852","VIOLATION_NO":"4493183","VIOLATION_ISSUE_DT":"12/19/2001","SIG_SUB":"Y","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"6","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/20/2001","PROPOSED_PENALTY":"161","AMOUNT_DUE":"161","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-19"},{"SOURCE_ROW_NUMBER":"835851","VIOLATION_NO":"4493182","VIOLATION_ISSUE_DT":"12/19/2001","SIG_SUB":"N","PART_SECTION":"75.1702","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/20/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-19"},{"SOURCE_ROW_NUMBER":"835850","VIOLATION_NO":"4493181","VIOLATION_ISSUE_DT":"12/19/2001","SIG_SUB":"N","PART_SECTION":"75.1101-23(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/20/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-19"},{"SOURCE_ROW_NUMBER":"835849","VIOLATION_NO":"4493180","VIOLATION_ISSUE_DT":"12/18/2001","SIG_SUB":"N","PART_SECTION":"75.601","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/19/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"835848","VIOLATION_NO":"4493179","VIOLATION_ISSUE_DT":"12/18/2001","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/19/2001","PROPOSED_PENALTY":"97","AMOUNT_DUE":"97","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"835847","VIOLATION_NO":"4493178","VIOLATION_ISSUE_DT":"12/18/2001","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/18/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"835846","VIOLATION_NO":"4493177","VIOLATION_ISSUE_DT":"12/18/2001","SIG_SUB":"N","PART_SECTION":"75.1100-2(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/18/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"835845","VIOLATION_NO":"4493176","VIOLATION_ISSUE_DT":"12/17/2001","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/18/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-17"},{"SOURCE_ROW_NUMBER":"835844","VIOLATION_NO":"4493175","VIOLATION_ISSUE_DT":"12/17/2001","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/18/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2001-12-17"}]}],"safety":{"href":"/api/v1/mines/1516183/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1516183/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Quarterly sampling; mechanized mining units.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.208","part":"70","subchapter":"O","subpart":"C","id":"70.208","citation":"30 CFR 70.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","heading":"Smoking; prohibition.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1702","part":"75","subchapter":"O","subpart":"R","id":"75.1702","citation":"30 CFR 75.1702","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Short circuit protection of trailing cables.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601","part":"75","subchapter":"O","subpart":"G","id":"75.601","citation":"30 CFR 75.601","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1516183","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}