{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1516177","name":"#2","status":"Abandoned and Sealed","status_date":"2004-12-30","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Floyd","nearest_town":"Beaver","operator_id":"P24301","operator_name":"T & M Coal Company Llc","controller_id":"C15878","controller_name":"Douglas K  Tackett; James R  Mitchell","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.410277,"longitude":-82.666388},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":546},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1516177","name":"#2"},"operator":{"type":"operator","id":"P24301","name":"T & M Coal Company Llc"},"controller":{"type":"controller","id":"C15878","name":"Douglas K  Tackett; James R  Mitchell"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P18963","name":"Dude Branch Mining Inc"},"object":{"type":"mine","id":"1516177","name":"#2"},"validFrom":"1987-09-01","validTo":"2000-07-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516177|P18963|1987-09-01|2000-07-26"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13125","name":"James R  Mitchell"},"object":{"type":"mine","id":"1516177","name":"#2"},"validFrom":"1987-09-01","validTo":"2000-07-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516177|C13125|1987-09-01|2000-07-26"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13125","name":"James R  Mitchell"},"object":{"type":"operator","id":"P18963","name":"Dude Branch Mining Inc"},"validFrom":"1987-09-01","validTo":"2000-07-26","current":false,"derived":true,"evidenceMineId":"1516177","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516177|P18963|1987-09-01|C13125|1987-09-01|88636"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15878","name":"James R  Mitchell et al"},"object":{"type":"mine","id":"1516177","name":"#2"},"validFrom":"1999-08-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516177|C15878|1999-08-17|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24301","name":"T & M Coal Company Llc"},"object":{"type":"mine","id":"1516177","name":"#2"},"validFrom":"2000-07-27","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516177|P24301|2000-07-27|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15878","name":"James R  Mitchell et al"},"object":{"type":"operator","id":"P24301","name":"T & M Coal Company Llc"},"validFrom":"2000-07-27","validTo":null,"current":true,"derived":true,"evidenceMineId":"1516177","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516177|P24301|2000-07-27|C15878|1999-08-17|97385"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15878","name":"Douglas K  Tackett et al"},"object":{"type":"operator","id":"P24301","name":"T & M Coal Company Llc"},"validFrom":"2000-07-27","validTo":null,"current":true,"derived":true,"evidenceMineId":"1516177","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516177|P24301|2000-07-27|C15878|1999-08-17|97386"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2001-02-26","lastDate":"2002-07-31","metrics":{"daysLost":796,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"138917","DOCUMENT_NO":"220022260009","ACCIDENT_DT":"07/31/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"186","NARRATIVE":"EMPLOYEE WAS STANDING IN MINE WHEN DRAW ROCK FELL AND HIT HIM ON THE LOWER BACK.","sourceDate":"2002-07-31"},{"SOURCE_ROW_NUMBER":"27183","DOCUMENT_NO":"220011560049","ACCIDENT_DT":"05/27/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"273","NARRATIVE":"EE WAS CLEARING ROCK FROM CONVEYOR FEEDER WHEN AROCK FLEW UP & SMASHED HIS RIGHT HAND & RING FINGER.","sourceDate":"2001-05-27"},{"SOURCE_ROW_NUMBER":"125733","DOCUMENT_NO":"220010730013","ACCIDENT_DT":"02/26/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"337","NARRATIVE":"EMP WAS CRAWLING & BACK SNAPPED, HE WAS CARRYING A BUCKET OF WATER AND HAMMER.","sourceDate":"2001-02-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2004-12-30","lastDate":"2004-12-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":127,"firstDate":"2000-08-09","lastDate":"2002-08-12","metrics":{"ss":45,"delinquent":127,"recentRows":0,"paidPenalty":5370,"proposedPenalty":11346,"currentAssessment":11346},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"976368","VIOLATION_NO":"7390677","ISSUE_DT":"08/12/2002","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"976367","VIOLATION_NO":"7390676","ISSUE_DT":"08/12/2002","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"976366","VIOLATION_NO":"7390675","ISSUE_DT":"08/07/2002","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-07"},{"SOURCE_ROW_NUMBER":"976365","VIOLATION_NO":"7390673","ISSUE_DT":"07/31/2002","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-31"},{"SOURCE_ROW_NUMBER":"976364","VIOLATION_NO":"7390672","ISSUE_DT":"07/31/2002","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-31"},{"SOURCE_ROW_NUMBER":"976363","VIOLATION_NO":"7390671","ISSUE_DT":"07/31/2002","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-31"},{"SOURCE_ROW_NUMBER":"974877","VIOLATION_NO":"7386789","ISSUE_DT":"07/15/2002","CFR_STANDARD_CD":"75.220","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-15"},{"SOURCE_ROW_NUMBER":"974876","VIOLATION_NO":"7386788","ISSUE_DT":"07/15/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-15"},{"SOURCE_ROW_NUMBER":"976347","VIOLATION_NO":"7390662","ISSUE_DT":"05/15/2002","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"976346","VIOLATION_NO":"7390661","ISSUE_DT":"05/15/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"976345","VIOLATION_NO":"7386720","ISSUE_DT":"05/15/2002","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"976344","VIOLATION_NO":"7386719","ISSUE_DT":"05/15/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-15"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":175,"firstDate":"2000-08-30","lastDate":"2002-10-11","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":10,"validSamples":165,"maxConcentration":6.788,"concentrationTotal":111.515},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1604629","CASS_NUM":"50656256","SMP_TAKEN_DT":"10/11/2002","CONC":".671","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-10-11"},{"SOURCE_ROW_NUMBER":"309714","CASS_NUM":"50656249","SMP_TAKEN_DT":"10/10/2002","CONC":"1.236","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-10-10"},{"SOURCE_ROW_NUMBER":"841023","CASS_NUM":"50656259","SMP_TAKEN_DT":"10/9/2002","CONC":".892","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-10-09"},{"SOURCE_ROW_NUMBER":"291193","CASS_NUM":"50656250","SMP_TAKEN_DT":"10/8/2002","CONC":"1.536","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-10-08"},{"SOURCE_ROW_NUMBER":"11414","CASS_NUM":"50656252","SMP_TAKEN_DT":"10/7/2002","CONC":"1.247","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"1447674","CASS_NUM":"57413521","SMP_TAKEN_DT":"10/1/2002","CONC":".164","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"926630","CASS_NUM":"57413484","SMP_TAKEN_DT":"10/1/2002","CONC":".072","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"1192164","CASS_NUM":"57410466","SMP_TAKEN_DT":"9/17/2002","CONC":".411","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"941033","CASS_NUM":"57410461","SMP_TAKEN_DT":"9/17/2002","CONC":".131","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"888402","CASS_NUM":"57410470","SMP_TAKEN_DT":"9/17/2002","CONC":".332","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"645193","CASS_NUM":"57410475","SMP_TAKEN_DT":"9/17/2002","CONC":".27","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"228303","CASS_NUM":"57410557","SMP_TAKEN_DT":"9/17/2002","CONC":".389","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-17"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1987-09-01","lastDate":"2000-07-27","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":47,"firstDate":"2000-03-01","lastDate":"2004-12-30","metrics":{"inspectors":57,"recentRows":0,"onSiteHours":664.25,"inspectionHours":993,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"219118","EVENT_NO":"4189002","INSPECTION_BEGIN_DT":"12/30/2004","INSPECTION_END_DT":"12/30/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2004-12-30"},{"SOURCE_ROW_NUMBER":"1159418","EVENT_NO":"4171146","INSPECTION_BEGIN_DT":"04/15/2004","INSPECTION_END_DT":"04/15/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2004-04-15"},{"SOURCE_ROW_NUMBER":"327370","EVENT_NO":"6188688","INSPECTION_BEGIN_DT":"01/07/2003","INSPECTION_END_DT":"01/07/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2003-01-07"},{"SOURCE_ROW_NUMBER":"274206","EVENT_NO":"4175466","INSPECTION_BEGIN_DT":"11/26/2002","INSPECTION_END_DT":"11/26/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2002-11-26"},{"SOURCE_ROW_NUMBER":"281798","EVENT_NO":"4175004","INSPECTION_BEGIN_DT":"10/18/2002","INSPECTION_END_DT":"12/10/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2002-10-18"},{"SOURCE_ROW_NUMBER":"350703","EVENT_NO":"5811950","INSPECTION_BEGIN_DT":"10/09/2002","INSPECTION_END_DT":"10/09/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2002-10-09"},{"SOURCE_ROW_NUMBER":"858330","EVENT_NO":"4174967","INSPECTION_BEGIN_DT":"10/01/2002","INSPECTION_END_DT":"10/02/2002","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"704782","EVENT_NO":"4174968","INSPECTION_BEGIN_DT":"10/01/2002","INSPECTION_END_DT":"10/02/2002","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"48234","EVENT_NO":"4174969","INSPECTION_BEGIN_DT":"10/01/2002","INSPECTION_END_DT":"10/22/2002","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"107410","EVENT_NO":"4174893","INSPECTION_BEGIN_DT":"08/21/2002","INSPECTION_END_DT":"10/01/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"75.5","SUM_TOTAL_ON_SITE_HOURS":"52.5","sourceDate":"2002-08-21"},{"SOURCE_ROW_NUMBER":"301441","EVENT_NO":"4174245","INSPECTION_BEGIN_DT":"07/15/2002","INSPECTION_END_DT":"07/16/2002","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2002-07-15"},{"SOURCE_ROW_NUMBER":"734285","EVENT_NO":"4174961","INSPECTION_BEGIN_DT":"07/02/2002","INSPECTION_END_DT":"09/30/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"82","SUM_TOTAL_ON_SITE_HOURS":"63","sourceDate":"2002-07-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":29,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003-Q1":{"hours":0,"employees":0,"production":0},"2002-Q4":{"hours":5830,"employees":15,"production":16312},"2002-Q3":{"hours":8386,"employees":28,"production":25133},"2002-Q2":{"hours":7740,"employees":22,"production":15042},"2002-Q1":{"hours":7509,"employees":22,"production":11761},"2001-Q4":{"hours":8797,"employees":24,"production":19360},"2001-Q3":{"hours":9415,"employees":32,"production":20403},"2001-Q2":{"hours":13175,"employees":38,"production":34190},"2001-Q1":{"hours":10,"employees":1,"production":0},"2000-Q4":{"hours":9050,"employees":33,"production":21264},"2000-Q3":{"hours":8344,"employees":24,"production":11718},"2000-Q2":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":17394,"employees":29,"production":32982},"2001":{"hours":31397,"employees":25,"production":73953},"2002":{"hours":29465,"employees":22,"production":68248}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":11,"firstDate":"2001-08-01","lastDate":"2002-10-01","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":507,"pelDoseTotal":319},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"52745","EVENT_NO":"4174968","SURVEY_DATE":"10/01/2002","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"29","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"52744","EVENT_NO":"4174968","SURVEY_DATE":"10/01/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"35","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"52743","EVENT_NO":"4174967","SURVEY_DATE":"10/01/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"49","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"52742","EVENT_NO":"4174967","SURVEY_DATE":"10/01/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"46","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"52741","EVENT_NO":"4174967","SURVEY_DATE":"10/01/2002","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"068","ACT_DOSE_85":"34","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"52740","EVENT_NO":"4174967","SURVEY_DATE":"10/01/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"31","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"52739","EVENT_NO":"4174967","SURVEY_DATE":"10/01/2002","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"61","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"52738","EVENT_NO":"4166233","SURVEY_DATE":"08/01/2001","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"77","PEL_DOSE_90":"63","SURVEY_TYPE":"I","sourceDate":"2001-08-01"},{"SOURCE_ROW_NUMBER":"52737","EVENT_NO":"4166233","SURVEY_DATE":"08/01/2001","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"20","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2001-08-01"},{"SOURCE_ROW_NUMBER":"52736","EVENT_NO":"4166233","SURVEY_DATE":"08/01/2001","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"86","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2001-08-01"},{"SOURCE_ROW_NUMBER":"52735","EVENT_NO":"4166233","SURVEY_DATE":"08/01/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"39","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2001-08-01"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":16,"firstDate":"2000-08-30","lastDate":"2002-10-14","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":21.7,"validSamples":15,"quartzPctTotal":75.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"70655","CASSETTE_NO":"50656258","SAMPLE_DT":"10/14/2002","QUARTZ_PCT":"02.2","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-10-14"},{"SOURCE_ROW_NUMBER":"144391","CASSETTE_NO":"50632911","SAMPLE_DT":"10/01/2002","QUARTZ_PCT":"02.9","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"19086","CASSETTE_NO":"57410466","SAMPLE_DT":"09/17/2002","QUARTZ_PCT":"21.7","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"5208","CASSETTE_NO":"57413337","SAMPLE_DT":"08/21/2002","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-08-21"},{"SOURCE_ROW_NUMBER":"67160","CASSETTE_NO":"57413582","SAMPLE_DT":"03/06/2002","QUARTZ_PCT":"01.5","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"45901","CASSETTE_NO":"57399797","SAMPLE_DT":"12/27/2001","QUARTZ_PCT":"03.2","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-27"},{"SOURCE_ROW_NUMBER":"92521","CASSETTE_NO":"57385638","SAMPLE_DT":"10/31/2001","QUARTZ_PCT":"03.2","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-10-31"},{"SOURCE_ROW_NUMBER":"141314","CASSETTE_NO":"57345931","SAMPLE_DT":"09/18/2001","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-09-18"},{"SOURCE_ROW_NUMBER":"43829","CASSETTE_NO":"57345890","SAMPLE_DT":"09/18/2001","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-09-18"},{"SOURCE_ROW_NUMBER":"66848","CASSETTE_NO":"57298635","SAMPLE_DT":"06/29/2001","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-29"},{"SOURCE_ROW_NUMBER":"57447","CASSETTE_NO":"57325935","SAMPLE_DT":"05/30/2001","QUARTZ_PCT":"02.1","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-05-30"},{"SOURCE_ROW_NUMBER":"80312","CASSETTE_NO":"50584838","SAMPLE_DT":"02/12/2001","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2001-02-12"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":127,"firstDate":"2000-08-09","lastDate":"2002-08-12","metrics":{"ss":45,"amountDue":11346,"contested":0,"amountPaid":5370,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":11346},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"835745","VIOLATION_NO":"7390677","VIOLATION_ISSUE_DT":"08/12/2002","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/12/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"835744","VIOLATION_NO":"7390676","VIOLATION_ISSUE_DT":"08/12/2002","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/12/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"835743","VIOLATION_NO":"7390675","VIOLATION_ISSUE_DT":"08/07/2002","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/07/2002","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-08-07"},{"SOURCE_ROW_NUMBER":"835742","VIOLATION_NO":"7390673","VIOLATION_ISSUE_DT":"07/31/2002","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/31/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-07-31"},{"SOURCE_ROW_NUMBER":"835741","VIOLATION_NO":"7390672","VIOLATION_ISSUE_DT":"07/31/2002","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/31/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-07-31"},{"SOURCE_ROW_NUMBER":"835740","VIOLATION_NO":"7390671","VIOLATION_ISSUE_DT":"07/31/2002","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/31/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-07-31"},{"SOURCE_ROW_NUMBER":"835747","VIOLATION_NO":"7386789","VIOLATION_ISSUE_DT":"07/15/2002","SIG_SUB":"N","PART_SECTION":"75.220","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/19/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-07-15"},{"SOURCE_ROW_NUMBER":"835746","VIOLATION_NO":"7386788","VIOLATION_ISSUE_DT":"07/15/2002","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"6","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/19/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-07-15"},{"SOURCE_ROW_NUMBER":"835732","VIOLATION_NO":"7390662","VIOLATION_ISSUE_DT":"05/15/2002","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"835731","VIOLATION_NO":"7390661","VIOLATION_ISSUE_DT":"05/15/2002","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"6","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"835730","VIOLATION_NO":"7386720","VIOLATION_ISSUE_DT":"05/15/2002","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"835729","VIOLATION_NO":"7386719","VIOLATION_ISSUE_DT":"05/15/2002","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-05-15"}]}],"safety":{"href":"/api/v1/mines/1516177/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1516177/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":3}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1516177","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}