{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1516036","name":"Mine #26","status":"Abandoned","status_date":"2007-04-20","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Kimper","operator_id":"P19831","operator_name":"McCoy Elkhorn Coal Corp","controller_id":"C13562","controller_name":"James River Coal Company","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.533333,"longitude":-82.394444},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1604},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1516036","name":"Mine #26"},"operator":{"type":"operator","id":"P19831","name":"McCoy Elkhorn Coal Corp"},"controller":{"type":"controller","id":"C13562","name":"James River Coal Company"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C06321","name":"Ingram Industries"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1979-04-09","validTo":"1992-03-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|C06321|1979-04-09|1992-03-08"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P18635","name":"Desparado Fuels Inc"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1987-05-01","validTo":"1989-07-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P18635|1987-05-01|1989-07-13"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C10457","name":"John F  Stapleton"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1987-05-01","validTo":"1990-04-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|C10457|1987-05-01|1990-04-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C10457","name":"John F  Stapleton"},"object":{"type":"operator","id":"P18635","name":"Desparado Fuels Inc"},"validFrom":"1987-05-01","validTo":"1989-07-13","current":false,"derived":true,"evidenceMineId":"1516036","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P18635|1987-05-01|C10457|1987-05-01|82039"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13346","name":"Stanley W Osborne"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1988-02-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|C13346|1988-02-11|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1988-09-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|C13562|1988-09-28|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11000","name":"James L  Bevins"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1989-04-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|C11000|1989-04-10|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19422","name":"Laurel Ridge Coal Company Inc"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1989-07-14","validTo":"1991-06-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P19422|1989-07-14|1991-06-19"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13346","name":"Stanley W Osborne"},"object":{"type":"operator","id":"P19422","name":"Laurel Ridge Coal Company Inc"},"validFrom":"1989-07-14","validTo":"1991-06-19","current":false,"derived":true,"evidenceMineId":"1516036","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P19422|1989-07-14|C13346|1988-02-11|89378"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19741","name":"Johns Creek Coal Company"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1991-06-20","validTo":"1992-03-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P19741|1991-06-20|1992-03-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06321","name":"Ingram Industries"},"object":{"type":"operator","id":"P19741","name":"Johns Creek Coal Company"},"validFrom":"1991-06-20","validTo":"1992-03-08","current":false,"derived":true,"evidenceMineId":"1516036","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P19741|1991-06-20|C06321|1979-04-09|71487"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19831","name":"Mc Coy Elkhorn Coal Corp"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1992-03-09","validTo":"1999-01-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P19831|1992-03-09|1999-01-06"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P19831","name":"Mc Coy Elkhorn Coal Corp"},"validFrom":"1992-03-09","validTo":"1999-01-06","current":false,"derived":true,"evidenceMineId":"1516036","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P19831|1992-03-09|C13562|1988-09-28|90318"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P20276","name":"Fools Gold Energy Corp"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"1999-01-07","validTo":"2004-10-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P20276|1999-01-07|2004-10-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11000","name":"James L  Bevins"},"object":{"type":"operator","id":"P20276","name":"Fools Gold Energy Corp"},"validFrom":"1999-01-07","validTo":"2004-10-11","current":false,"derived":true,"evidenceMineId":"1516036","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P20276|1999-01-07|C11000|1989-04-10|83350"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19831","name":"McCoy Elkhorn Coal Corp"},"object":{"type":"mine","id":"1516036","name":"Mine #26"},"validFrom":"2004-10-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P19831|2004-10-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P19831","name":"McCoy Elkhorn Coal Corp"},"validFrom":"2004-10-12","validTo":null,"current":true,"derived":true,"evidenceMineId":"1516036","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1516036|P19831|2004-10-12|C13562|1988-09-28|90319"}}],"coverage":{"historyRecords":6,"edgeCount":17,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":20,"firstDate":"2000-05-26","lastDate":"2006-10-27","metrics":{"daysLost":459,"injuries":20,"fatalities":0,"recentRows":0,"restrictedDays":54,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"250840","DOCUMENT_NO":"220063030040","ACCIDENT_DT":"10/27/2006","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A rock fall occurred int he #1 entry approx. 80' inby the #1 portal. The rock fall was 17' long, 18' wide, and 6' thick. Fall was approx. 1400' from the working section.","sourceDate":"2006-10-27"},{"SOURCE_ROW_NUMBER":"190484","DOCUMENT_NO":"220062400048","ACCIDENT_DT":"08/25/2006","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall measuring approximately 4' thick, 12' wide, and 18' long occurred in the intersection of the no. 2 entry 1 break inby survey station no. 731. Fall location is approximately 500' outby working section.","sourceDate":"2006-08-25"},{"SOURCE_ROW_NUMBER":"112979","DOCUMENT_NO":"220061940034","ACCIDENT_DT":"07/10/2006","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was setting timbers in the #6 entry of the 002 section and a coal rib rolled off and struck him on the back and hips.","sourceDate":"2006-07-10"},{"SOURCE_ROW_NUMBER":"27182","DOCUMENT_NO":"220061580026","ACCIDENT_DT":"06/03/2006","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"2","DAYS_LOST":"39","NARRATIVE":"EE was talking with the continuous miner operator in the #2 entry of the 002-0 mmu when a piece of draw rock fell, striking a shuttle car then flipping off onto him, injuring his left arm, right foot and head. EE was treated and released at Pikeville Medical Center.","sourceDate":"2006-06-03"},{"SOURCE_ROW_NUMBER":"9923","DOCUMENT_NO":"220061580028","ACCIDENT_DT":"06/03/2006","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"2","DAYS_LOST":"0","NARRATIVE":"EE was operating a continuous miner in the #2 entry of the 002-0mmu when a piece of draw rock fell, striking a shuttle car, then flipping off on him, injuring his back. EE was treated and released at Pikeville Medical Center.","sourceDate":"2006-06-03"},{"SOURCE_ROW_NUMBER":"267944","DOCUMENT_NO":"220061420024","ACCIDENT_DT":"05/19/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"13","NARRATIVE":"EE was operating a shuttle car in the #3 entry of the 002-0 mmu. He was hauling a load of coal to the feeder when a piece of draw rock, approx. 24\" wide, 41\" long & 3\" thick fell from between the bolts and struck him on the head, shoulder and chest. He was transported to the medical center and admitted for observation. Accident occurred in the first crosscut outby the face.","sourceDate":"2006-05-19"},{"SOURCE_ROW_NUMBER":"181966","DOCUMENT_NO":"220061440041","ACCIDENT_DT":"05/19/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Stopping builder, Ventilation man, Mason man, Overcast","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was getting an air reading behind the line curtain in the #4 entry of the 002-0 mmu when the coal rib rolled and struck him on the right hip and leg. He continued working until the end of his regular shift. On Saturday, 5/20, he went to the E.R. where he was treated and released.","sourceDate":"2006-05-19"},{"SOURCE_ROW_NUMBER":"87296","DOCUMENT_NO":"220061250033","ACCIDENT_DT":"04/29/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Stopping builder, Ventilation man, Mason man, Overcast","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Large rock on miner; he tried to remove the rock and pinched his left hand.","sourceDate":"2006-04-29"},{"SOURCE_ROW_NUMBER":"203403","DOCUMENT_NO":"220050530119","ACCIDENT_DT":"02/15/2005","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was operating a roof bolter in the #3 heading of the 002-0 section. He was installing a roof bolt in the mine roof, and when he reached to align the roof bolt plate, his glove got caught on the plate, dislocating the little finger on his left hand.","sourceDate":"2005-02-15"},{"SOURCE_ROW_NUMBER":"117256","DOCUMENT_NO":"220030940045","ACCIDENT_DT":"03/21/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"WAS RAISING 21SC JOY SHUTTLE CAR WITH LIFTING JACK AND SLIPPED AND FELL. LIFTING JACK BAR HIT RIBS LEFT SIDE OF BODY.","sourceDate":"2003-03-21"},{"SOURCE_ROW_NUMBER":"65695","DOCUMENT_NO":"220030840018","ACCIDENT_DT":"03/10/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"79","NARRATIVE":"EE CLAIMS THAT RIB ROLL HIT HIS RIGHT HIP. BRUISED RIGHT HIP. WHILE OPERATING EIMCO CONT. MINER.REMOTE CONTROLLED.","sourceDate":"2003-03-10"},{"SOURCE_ROW_NUMBER":"14245","DOCUMENT_NO":"220031250019","ACCIDENT_DT":"02/22/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"18","NARRATIVE":"EE WAS LIFTING CRIB BLOCKS. HE SAID HE FELT A PULL IN HIS LEFT ABDOMEN AREA. THIS ACCIDENT HAPPENED ON 2/22/03. HAD NO LOST TIME UNTIL HE WAS OPERATED ON 4/16/03 FOR DOUBLE HERNIA.","sourceDate":"2003-02-22"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-04-20","lastDate":"2007-04-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":288,"firstDate":"2000-03-07","lastDate":"2006-11-09","metrics":{"ss":153,"delinquent":285,"recentRows":0,"paidPenalty":66278,"proposedPenalty":76976,"currentAssessment":74076},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"971559","VIOLATION_NO":"7431366","ISSUE_DT":"11/09/2006","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-11-09"},{"SOURCE_ROW_NUMBER":"971558","VIOLATION_NO":"7431365","ISSUE_DT":"11/09/2006","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-11-09"},{"SOURCE_ROW_NUMBER":"971557","VIOLATION_NO":"7431362","ISSUE_DT":"11/07/2006","CFR_STANDARD_CD":"48.28(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"237.00","CURRENT_ASSESSMENT_AMT":"237.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-11-07"},{"SOURCE_ROW_NUMBER":"971556","VIOLATION_NO":"7431361","ISSUE_DT":"11/07/2006","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-11-07"},{"SOURCE_ROW_NUMBER":"971555","VIOLATION_NO":"7431319","ISSUE_DT":"11/02/2006","CFR_STANDARD_CD":"75.1714-3(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-11-02"},{"SOURCE_ROW_NUMBER":"971554","VIOLATION_NO":"7431318","ISSUE_DT":"11/02/2006","CFR_STANDARD_CD":"75.208","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"191.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-11-02"},{"SOURCE_ROW_NUMBER":"971553","VIOLATION_NO":"7431313","ISSUE_DT":"10/25/2006","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"191.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-25"},{"SOURCE_ROW_NUMBER":"971552","VIOLATION_NO":"7431311","ISSUE_DT":"10/17/2006","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"191.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-17"},{"SOURCE_ROW_NUMBER":"971551","VIOLATION_NO":"7431307","ISSUE_DT":"10/13/2006","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"191.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-13"},{"SOURCE_ROW_NUMBER":"971550","VIOLATION_NO":"7431306","ISSUE_DT":"10/12/2006","CFR_STANDARD_CD":"75.523-3(c)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"971549","VIOLATION_NO":"7431305","ISSUE_DT":"10/12/2006","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"971548","VIOLATION_NO":"7431304","ISSUE_DT":"10/12/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-12"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":3,"firstDate":"2008-08-11","lastDate":"2008-08-11","metrics":{"appeals":0,"decisions":3,"recentRows":0,"decisionPenalty":40600,"originalPenalty":43500},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"198397","VIOLATION_NO":"7426912","DOCKET_NO":"KENT 2007-194","DECISION_DT":"08/11/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"14500.00","DECISION_PENALTY_AMT":"11600.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2008-08-11"},{"SOURCE_ROW_NUMBER":"198396","VIOLATION_NO":"7426910","DOCKET_NO":"KENT 2007-194","DECISION_DT":"08/11/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"14500.00","DECISION_PENALTY_AMT":"14500.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2008-08-11"},{"SOURCE_ROW_NUMBER":"197838","VIOLATION_NO":"7426911","DOCKET_NO":"KENT 2007-194","DECISION_DT":"08/11/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"14500.00","DECISION_PENALTY_AMT":"14500.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2008-08-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":522,"firstDate":"2000-01-10","lastDate":"2006-11-13","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":35,"validSamples":487,"maxConcentration":8.045,"concentrationTotal":420.024},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"458289","CASS_NUM":"50860665","SMP_TAKEN_DT":"11/13/2006","CONC":".955","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-11-13"},{"SOURCE_ROW_NUMBER":"1610080","CASS_NUM":"50860662","SMP_TAKEN_DT":"11/10/2006","CONC":".674","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-11-10"},{"SOURCE_ROW_NUMBER":"1286231","CASS_NUM":"50860681","SMP_TAKEN_DT":"11/10/2006","CONC":".487","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-11-10"},{"SOURCE_ROW_NUMBER":"889869","CASS_NUM":"50860647","SMP_TAKEN_DT":"11/10/2006","CONC":".685","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-11-10"},{"SOURCE_ROW_NUMBER":"1335025","CASS_NUM":"50860659","SMP_TAKEN_DT":"11/9/2006","CONC":".667","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-11-09"},{"SOURCE_ROW_NUMBER":"873365","CASS_NUM":"50860671","SMP_TAKEN_DT":"11/9/2006","CONC":".481","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-11-09"},{"SOURCE_ROW_NUMBER":"1531337","CASS_NUM":"57631885","SMP_TAKEN_DT":"10/5/2006","CONC":".15","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SECTION FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-05"},{"SOURCE_ROW_NUMBER":"1444373","CASS_NUM":"57631875","SMP_TAKEN_DT":"10/5/2006","CONC":".123","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-05"},{"SOURCE_ROW_NUMBER":"1256272","CASS_NUM":"57631880","SMP_TAKEN_DT":"10/5/2006","CONC":".353","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-05"},{"SOURCE_ROW_NUMBER":"1188779","CASS_NUM":"57631871","SMP_TAKEN_DT":"10/5/2006","CONC":".792","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-05"},{"SOURCE_ROW_NUMBER":"1086295","CASS_NUM":"57631820","SMP_TAKEN_DT":"10/5/2006","CONC":".081","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-05"},{"SOURCE_ROW_NUMBER":"807835","CASS_NUM":"57631826","SMP_TAKEN_DT":"10/5/2006","CONC":".104","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-05"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":3,"firstDate":"2006-06-05","lastDate":"2006-06-05","metrics":{"decisions":3,"ssChanged":0,"recentRows":0,"decisionPenalty":40600,"proposedPenalty":43500},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"341435","CITATION_NO":"7426912","CITATION_ISSUE_DT":"06/05/2006","DOCKET_NO":"KENT 2007-194","DECISION_DT":"08/11/2008","CFR_STANDARD_CODE":"75.360","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"14500.00","DECISION_PENALTY_AMT":"11600.00","sourceDate":"2006-06-05"},{"SOURCE_ROW_NUMBER":"173218","CITATION_NO":"7426910","CITATION_ISSUE_DT":"06/05/2006","DOCKET_NO":"KENT 2007-194","DECISION_DT":"08/11/2008","CFR_STANDARD_CODE":"75.202(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"14500.00","DECISION_PENALTY_AMT":"14500.00","sourceDate":"2006-06-05"},{"SOURCE_ROW_NUMBER":"115465","CITATION_NO":"7426911","CITATION_ISSUE_DT":"06/05/2006","DOCKET_NO":"KENT 2007-194","DECISION_DT":"08/11/2008","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"14500.00","DECISION_PENALTY_AMT":"14500.00","sourceDate":"2006-06-05"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":170,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":38,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"1987-05-01","lastDate":"2004-10-12","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":5},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":111,"firstDate":"2000-02-29","lastDate":"2007-04-02","metrics":{"inspectors":139,"recentRows":0,"onSiteHours":2054.5,"inspectionHours":3077.25,"inspectionSamples":68},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"708951","EVENT_NO":"4173345","INSPECTION_BEGIN_DT":"04/02/2007","INSPECTION_END_DT":"04/20/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2007-04-02"},{"SOURCE_ROW_NUMBER":"666009","EVENT_NO":"4173460","INSPECTION_BEGIN_DT":"01/05/2007","INSPECTION_END_DT":"01/05/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2007-01-05"},{"SOURCE_ROW_NUMBER":"915584","EVENT_NO":"4192846","INSPECTION_BEGIN_DT":"10/27/2006","INSPECTION_END_DT":"10/27/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2006-10-27"},{"SOURCE_ROW_NUMBER":"456212","EVENT_NO":"4173454","INSPECTION_BEGIN_DT":"10/02/2006","INSPECTION_END_DT":"11/16/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"112.25","SUM_TOTAL_ON_SITE_HOURS":"80.5","sourceDate":"2006-10-02"},{"SOURCE_ROW_NUMBER":"709184","EVENT_NO":"4173308","INSPECTION_BEGIN_DT":"08/28/2006","INSPECTION_END_DT":"08/28/2006","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2006-08-28"},{"SOURCE_ROW_NUMBER":"710138","EVENT_NO":"4173301","INSPECTION_BEGIN_DT":"07/03/2006","INSPECTION_END_DT":"09/22/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"105.75","SUM_TOTAL_ON_SITE_HOURS":"72.25","sourceDate":"2006-07-03"},{"SOURCE_ROW_NUMBER":"620877","EVENT_NO":"4192829","INSPECTION_BEGIN_DT":"06/03/2006","INSPECTION_END_DT":"06/19/2006","ACTIVITY_CODE":"E07","ACTIVITY":"Non-Fatal Accident Investigation","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"70.5","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2006-06-03"},{"SOURCE_ROW_NUMBER":"548325","EVENT_NO":"4192830","INSPECTION_BEGIN_DT":"06/03/2006","INSPECTION_END_DT":"06/19/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"40.5","SUM_TOTAL_ON_SITE_HOURS":"19.5","sourceDate":"2006-06-03"},{"SOURCE_ROW_NUMBER":"504913","EVENT_NO":"4172948","INSPECTION_BEGIN_DT":"05/30/2006","INSPECTION_END_DT":"05/31/2006","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2006-05-30"},{"SOURCE_ROW_NUMBER":"216361","EVENT_NO":"4172944","INSPECTION_BEGIN_DT":"04/03/2006","INSPECTION_END_DT":"06/12/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"99.5","SUM_TOTAL_ON_SITE_HOURS":"67.5","sourceDate":"2006-04-03"},{"SOURCE_ROW_NUMBER":"403801","EVENT_NO":"4172742","INSPECTION_BEGIN_DT":"01/03/2006","INSPECTION_END_DT":"03/21/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"117","SUM_TOTAL_ON_SITE_HOURS":"87","sourceDate":"2006-01-03"},{"SOURCE_ROW_NUMBER":"968775","EVENT_NO":"4172735","INSPECTION_BEGIN_DT":"10/03/2005","INSPECTION_END_DT":"12/29/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"122","SUM_TOTAL_ON_SITE_HOURS":"92","sourceDate":"2005-10-03"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":58,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007-Q2":{"hours":0,"employees":0,"production":0},"2007-Q1":{"hours":0,"employees":0,"production":0},"2006-Q4":{"hours":14708,"employees":28,"production":37440},"2006-Q3":{"hours":15806,"employees":28,"production":28478},"2006-Q2":{"hours":18197,"employees":30,"production":49415},"2006-Q1":{"hours":18831,"employees":29,"production":52065},"2005-Q4":{"hours":18082,"employees":30,"production":50613},"2005-Q3":{"hours":16494,"employees":28,"production":47319},"2005-Q2":{"hours":14457,"employees":23,"production":43773},"2005-Q1":{"hours":8997,"employees":14,"production":22852},"2004-Q4":{"hours":2874,"employees":4,"production":490},"2004-Q3":{"hours":4745,"employees":25,"production":14102}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":71117,"employees":28,"production":211333},"2001":{"hours":65708,"employees":30,"production":205650},"2002":{"hours":62215,"employees":26,"production":196695},"2003":{"hours":62635,"employees":27,"production":179198},"2004":{"hours":23450,"employees":20,"production":63373},"2005":{"hours":58030,"employees":24,"production":164557},"2006":{"hours":67542,"employees":29,"production":167398}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":38,"firstDate":"2001-01-16","lastDate":"2006-11-01","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":2030,"pelDoseTotal":1416},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"52277","EVENT_NO":"4173454","SURVEY_DATE":"11/01/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"92","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2006-11-01"},{"SOURCE_ROW_NUMBER":"52276","EVENT_NO":"4173454","SURVEY_DATE":"11/01/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"62","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2006-11-01"},{"SOURCE_ROW_NUMBER":"52275","EVENT_NO":"4173454","SURVEY_DATE":"11/01/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"113","PEL_DOSE_90":"95","SURVEY_TYPE":"I","sourceDate":"2006-11-01"},{"SOURCE_ROW_NUMBER":"52274","EVENT_NO":"4173454","SURVEY_DATE":"11/01/2006","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"17","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2006-11-01"},{"SOURCE_ROW_NUMBER":"52273","EVENT_NO":"4173454","SURVEY_DATE":"11/01/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"100","PEL_DOSE_90":"85","SURVEY_TYPE":"I","sourceDate":"2006-11-01"},{"SOURCE_ROW_NUMBER":"52272","EVENT_NO":"4173301","SURVEY_DATE":"09/13/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2006-09-13"},{"SOURCE_ROW_NUMBER":"52271","EVENT_NO":"4173301","SURVEY_DATE":"09/13/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"63","SURVEY_TYPE":"I","sourceDate":"2006-09-13"},{"SOURCE_ROW_NUMBER":"52270","EVENT_NO":"4173301","SURVEY_DATE":"09/13/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"81","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2006-09-13"},{"SOURCE_ROW_NUMBER":"52269","EVENT_NO":"4173301","SURVEY_DATE":"09/13/2006","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"22","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2006-09-13"},{"SOURCE_ROW_NUMBER":"52268","EVENT_NO":"4173301","SURVEY_DATE":"09/13/2006","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"27","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2006-09-13"},{"SOURCE_ROW_NUMBER":"52267","EVENT_NO":"4173301","SURVEY_DATE":"09/13/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"24","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2006-09-13"},{"SOURCE_ROW_NUMBER":"52266","EVENT_NO":"4173301","SURVEY_DATE":"09/13/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"60","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2006-09-13"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":40,"firstDate":"2000-04-12","lastDate":"2006-10-05","metrics":{"recentRows":0,"voidSamples":4,"maxQuartzPct":14.5,"validSamples":36,"quartzPctTotal":187.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"162464","CASSETTE_NO":"57631871","SAMPLE_DT":"10/05/2006","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-10-05"},{"SOURCE_ROW_NUMBER":"95690","CASSETTE_NO":"57583676","SAMPLE_DT":"05/17/2006","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-05-17"},{"SOURCE_ROW_NUMBER":"25826","CASSETTE_NO":"57583557","SAMPLE_DT":"03/20/2006","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-03-20"},{"SOURCE_ROW_NUMBER":"66207","CASSETTE_NO":"57580441","SAMPLE_DT":"09/13/2005","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-13"},{"SOURCE_ROW_NUMBER":"14921","CASSETTE_NO":"57580465","SAMPLE_DT":"09/13/2005","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-13"},{"SOURCE_ROW_NUMBER":"35538","CASSETTE_NO":"57466330","SAMPLE_DT":"06/06/2005","QUARTZ_PCT":"02.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"23962","CASSETTE_NO":"57466332","SAMPLE_DT":"06/06/2005","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"30107","CASSETTE_NO":"57466501","SAMPLE_DT":"05/17/2005","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-05-17"},{"SOURCE_ROW_NUMBER":"130219","CASSETTE_NO":"57508327","SAMPLE_DT":"03/02/2005","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-03-02"},{"SOURCE_ROW_NUMBER":"64900","CASSETTE_NO":"57508333","SAMPLE_DT":"03/02/2005","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-03-02"},{"SOURCE_ROW_NUMBER":"6184","CASSETTE_NO":"57508018","SAMPLE_DT":"01/18/2005","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-18"},{"SOURCE_ROW_NUMBER":"157882","CASSETTE_NO":"57555286","SAMPLE_DT":"06/21/2004","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-21"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":293,"firstDate":"2000-03-07","lastDate":"2006-11-09","metrics":{"ss":153,"amountDue":74076,"contested":3,"amountPaid":66278,"recentRows":0,"section104d":4,"unterminated":0,"proposedPenalty":76976},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"833299","VIOLATION_NO":"7431366","VIOLATION_ISSUE_DT":"11/09/2006","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/09/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-11-09"},{"SOURCE_ROW_NUMBER":"833298","VIOLATION_NO":"7431365","VIOLATION_ISSUE_DT":"11/09/2006","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/09/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-11-09"},{"SOURCE_ROW_NUMBER":"833297","VIOLATION_NO":"7431362","VIOLATION_ISSUE_DT":"11/07/2006","SIG_SUB":"Y","PART_SECTION":"48.28(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/09/2006","PROPOSED_PENALTY":"237","AMOUNT_DUE":"237","AMOUNT_PAID":"237","CONTESTED_IND":"N","sourceDate":"2006-11-07"},{"SOURCE_ROW_NUMBER":"833296","VIOLATION_NO":"7431361","VIOLATION_ISSUE_DT":"11/07/2006","SIG_SUB":"Y","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/09/2006","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2006-11-07"},{"SOURCE_ROW_NUMBER":"833295","VIOLATION_NO":"7431319","VIOLATION_ISSUE_DT":"11/02/2006","SIG_SUB":"N","PART_SECTION":"75.1714-3(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/02/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-11-02"},{"SOURCE_ROW_NUMBER":"833294","VIOLATION_NO":"7431318","VIOLATION_ISSUE_DT":"11/02/2006","SIG_SUB":"Y","PART_SECTION":"75.208","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/02/2006","PROPOSED_PENALTY":"191","AMOUNT_DUE":"191","AMOUNT_PAID":"191","CONTESTED_IND":"N","sourceDate":"2006-11-02"},{"SOURCE_ROW_NUMBER":"833293","VIOLATION_NO":"7431313","VIOLATION_ISSUE_DT":"10/25/2006","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/27/2006","PROPOSED_PENALTY":"191","AMOUNT_DUE":"191","AMOUNT_PAID":"191","CONTESTED_IND":"N","sourceDate":"2006-10-25"},{"SOURCE_ROW_NUMBER":"833292","VIOLATION_NO":"7431311","VIOLATION_ISSUE_DT":"10/17/2006","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/17/2006","PROPOSED_PENALTY":"191","AMOUNT_DUE":"191","AMOUNT_PAID":"191","CONTESTED_IND":"N","sourceDate":"2006-10-17"},{"SOURCE_ROW_NUMBER":"833291","VIOLATION_NO":"7431307","VIOLATION_ISSUE_DT":"10/13/2006","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/17/2006","PROPOSED_PENALTY":"191","AMOUNT_DUE":"191","AMOUNT_PAID":"191","CONTESTED_IND":"N","sourceDate":"2006-10-13"},{"SOURCE_ROW_NUMBER":"833290","VIOLATION_NO":"7431306","VIOLATION_ISSUE_DT":"10/12/2006","SIG_SUB":"N","PART_SECTION":"75.523-3(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/12/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"833289","VIOLATION_NO":"7431305","VIOLATION_ISSUE_DT":"10/12/2006","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/13/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"833288","VIOLATION_NO":"7431304","VIOLATION_ISSUE_DT":"10/12/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/12/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-12"}]}],"safety":{"href":"/api/v1/mines/1516036/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1516036/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","heading":"Annual refresher training of miners; minimum courses of instruction; hours of instruction.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.28","part":"48","subchapter":"H","subpart":"B","id":"48.28","citation":"30 CFR 48.28","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Warning devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.208","part":"75","subchapter":"O","subpart":"C","id":"75.208","citation":"30 CFR 75.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1516036","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}