{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1515215","name":"# 5","status":"Abandoned and Sealed","status_date":"2023-08-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Phyllis","operator_id":"0114885","operator_name":"Bee B & B, LLC","controller_id":"0146161","controller_name":"Josh  Young","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.448333,"longitude":-82.337222},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":5282},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1515215","name":"# 5"},"operator":{"type":"operator","id":"0114885","name":"Bee B & B, LLC"},"controller":{"type":"controller","id":"0146161","name":"Josh  Young"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|C00375|1950-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00396","name":"Wellmore Coal Corp"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"1985-05-01","validTo":"2009-11-10","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|P00396|1985-05-01|2009-11-10"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"operator","id":"P00396","name":"Wellmore Coal Corp"},"validFrom":"1985-05-01","validTo":"2009-11-10","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|P00396|1985-05-01|C00375|1950-01-01|46511"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13340","name":"Kenneth L  Stacy"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2001-08-01","validTo":"2006-02-09","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|C13340|2001-08-01|2006-02-09"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2006-02-10","validTo":"2009-04-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|C00375|2006-02-10|2009-04-29"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0085453","name":"Metinvest B V"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2009-04-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0085453|2009-04-30|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24715","name":"Surface Minerals Company"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2009-11-11","validTo":"2010-05-10","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|P24715|2009-11-11|2010-05-10"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0085453","name":"Metinvest B V"},"object":{"type":"operator","id":"P24715","name":"Surface Minerals Company"},"validFrom":"2009-11-11","validTo":"2010-05-10","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|P24715|2009-11-11|0085453|2009-04-30|13475"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"operator","id":"P24715","name":"Surface Minerals Company"},"validFrom":"2009-11-11","validTo":"2009-04-29","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|P24715|2009-11-11|C00375|2006-02-10|46764"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13340","name":"Kenneth L  Stacy"},"object":{"type":"operator","id":"P24715","name":"Surface Minerals Company"},"validFrom":"2009-11-11","validTo":"2006-02-09","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|P24715|2009-11-11|C13340|2001-08-01|89326"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0109885","name":"M-T Coal Company LLC"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2010-05-11","validTo":"2011-01-09","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0109885|2010-05-11|2011-01-09"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C10445","name":"Thurman  Harness"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2010-05-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|C10445|2010-05-11|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C10445","name":"Thurman  Harness"},"object":{"type":"operator","id":"0109885","name":"M-T Coal Company LLC"},"validFrom":"2010-05-11","validTo":"2011-01-09","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0109885|2010-05-11|C10445|2010-05-11|82016"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0095373","name":"Douglas K  Tackett"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2010-08-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0095373|2010-08-25|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0073313","name":"Bee  Handshoe"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2010-11-08","validTo":"2019-03-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0073313|2010-11-08|2019-03-06"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0073731","name":"Jimmy D  Tackett"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2010-11-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0073731|2010-11-10|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0112645","name":"Mercy Mining, LLC"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2011-01-10","validTo":"2011-11-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0112645|2011-01-10|2011-11-07"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0095373","name":"Douglas K  Tackett"},"object":{"type":"operator","id":"0112645","name":"Mercy Mining, LLC"},"validFrom":"2011-01-10","validTo":"2011-11-07","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0112645|2011-01-10|0095373|2010-08-25|15705"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0120013","name":"Daystar Coal, LLC"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2011-11-08","validTo":"2011-12-05","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0120013|2011-11-08|2011-12-05"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0078613","name":"George Chris  Waugh"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2011-11-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0078613|2011-11-08|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0078613","name":"George Chris  Waugh"},"object":{"type":"operator","id":"0120013","name":"Daystar Coal, LLC"},"validFrom":"2011-11-08","validTo":"2011-12-05","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0120013|2011-11-08|0078613|2011-11-08|12363"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0115605","name":"Pike Floyd Mining, Inc."},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2011-12-06","validTo":"2014-10-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0115605|2011-12-06|2014-10-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0073731","name":"Jimmy D  Tackett"},"object":{"type":"operator","id":"0115605","name":"Pike Floyd Mining, Inc."},"validFrom":"2011-12-06","validTo":"2014-10-30","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0115605|2011-12-06|0073731|2010-11-10|11465"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0135573","name":"Clintwood Coal Corporation"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2014-10-31","validTo":"2015-03-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0135573|2014-10-31|2015-03-11"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0115381","name":"Bobby  Tackett"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2014-10-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0115381|2014-10-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0115381","name":"Bobby  Tackett"},"object":{"type":"operator","id":"0135573","name":"Clintwood Coal Corporation"},"validFrom":"2014-10-31","validTo":"2015-03-11","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0135573|2014-10-31|0115381|2014-10-31|21716"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0114885","name":"Bee B & B, LLC"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2015-03-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0114885|2015-03-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0073313","name":"Bee  Handshoe"},"object":{"type":"operator","id":"0114885","name":"Bee B & B, LLC"},"validFrom":"2015-03-12","validTo":"2019-03-06","current":false,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0114885|2015-03-12|0073313|2010-11-08|11400"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0146161","name":"Josh  Young"},"object":{"type":"mine","id":"1515215","name":"# 5"},"validFrom":"2019-03-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0146161|2019-03-07|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0146161","name":"Josh  Young"},"object":{"type":"operator","id":"0114885","name":"Bee B & B, LLC"},"validFrom":"2019-03-07","validTo":null,"current":true,"derived":true,"evidenceMineId":"1515215","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1515215|0114885|2015-03-12|0146161|2019-03-07|29923"}}],"coverage":{"historyRecords":11,"edgeCount":30,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":16,"firstDate":"2011-07-12","lastDate":"2021-06-14","metrics":{"daysLost":1036,"injuries":14,"fatalities":0,"recentRows":2,"restrictedDays":47,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"177654","DOCUMENT_NO":"220211650032","ACCIDENT_DT":"06/14/2021","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The employee was loading structure onto a trailer to be moved and EE dropped a piece of the structure on EE's foot causing EE's foot to swell.","sourceDate":"2021-06-14"},{"SOURCE_ROW_NUMBER":"267941","DOCUMENT_NO":"220210750025","ACCIDENT_DT":"03/12/2021","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was installing a roof bolt in #2 heading when EE was attempting to push the bolt over to the bolter drill pot, the bolt kicked back resulting in a sprained left shoulder. Employee didn't go to the ER until 03/15/2021 and will follow-up on 03/18/2021.","sourceDate":"2021-03-12"},{"SOURCE_ROW_NUMBER":"250838","DOCUMENT_NO":"220203140010","ACCIDENT_DT":"11/09/2020","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The employee was operating a scoop and when turning a corner they inadvertly placed a hand on the bumper pad at the center section and when the scoop made it's swivel it pinched the two middle fingers on left hand.","sourceDate":"2020-11-09"},{"SOURCE_ROW_NUMBER":"246526","DOCUMENT_NO":"220203000022","ACCIDENT_DT":"10/23/2020","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The miner states that EE was dragging a bag of rock dust down 2 belt to dust it when EE's ribs started hurting. EE states didn't hit anything so EE is unsure what hurt EE.","sourceDate":"2020-10-23"},{"SOURCE_ROW_NUMBER":"263737","DOCUMENT_NO":"220201630005","ACCIDENT_DT":"06/03/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"Employee says that when EE was bending a bolt it slipped and shifted EE's weight causing pain in EE's left shoulder and chest area. The employee did not tell the Foreman that EE was injured until 06/08/2020, knowing that if you are injured it is to be reported immediately.","sourceDate":"2020-06-03"},{"SOURCE_ROW_NUMBER":"1291","DOCUMENT_NO":"220201220016","ACCIDENT_DT":"04/27/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Driller operator","NO_INJURIES":"1","DAYS_LOST":"84","NARRATIVE":"The employee stated that EE was getting off of the drill and somehow EE's foot got caught on the drill causing EE to twist right knee. The employee worked the rest of the shift without reporting the accident. The employee didn't show up for work the next day. Then two days later the employee said that EE had went to the ER.","sourceDate":"2020-04-27"},{"SOURCE_ROW_NUMBER":"44253","DOCUMENT_NO":"220192600021","ACCIDENT_DT":"09/12/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"169","NARRATIVE":"Employee was loading tool bar on 4 wheel buggy and claimed to have twisted the wrong way and threw back out.","sourceDate":"2019-09-12"},{"SOURCE_ROW_NUMBER":"160476","DOCUMENT_NO":"220192350001","ACCIDENT_DT":"08/05/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Blaster, Shooter, Shotfirer, Explosive worker, Powder gang/monkey","NO_INJURIES":"1","DAYS_LOST":"209","NARRATIVE":"Accident was not reported until 8/15/19. This employee said EE developed an infection in EE's hand later due to this small scratch.","sourceDate":"2019-08-05"},{"SOURCE_ROW_NUMBER":"61435","DOCUMENT_NO":"220183530001","ACCIDENT_DT":"12/12/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was busting rock, attempted to strike a rock 4in thick, 2ft. wide, when EE did, the rock flew toward EE hitting EE's right hand. EE was taken to ER for treatment where EE received x-rays and 6 stitches. EE was released to return to full duty the same day.","sourceDate":"2018-12-12"},{"SOURCE_ROW_NUMBER":"39991","DOCUMENT_NO":"220181000016","ACCIDENT_DT":"04/04/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"385","NARRATIVE":"While hauling out of #2 on scoop EE ran over a rock bouncing & jarring back.","sourceDate":"2018-04-04"},{"SOURCE_ROW_NUMBER":"100046","DOCUMENT_NO":"220180580029","ACCIDENT_DT":"02/26/2018","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Non injury roof fall was discovered 2/26/18 at 6am on the return side #4 entry spad# 1 break inby 1814. Cribbed area off, did not impede travel &/or hamper ventilation. Approximately 8' high, 20' wide x 20' long.","sourceDate":"2018-02-26"},{"SOURCE_ROW_NUMBER":"61434","DOCUMENT_NO":"220171950003","ACCIDENT_DT":"07/13/2017","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was attempting to bust a block of coal and accidentally contacted the roof with the hammer and dislodged a rock which fell and struck employee's hand causing a laceration.","sourceDate":"2017-07-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2023-08-16","lastDate":"2023-08-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1305,"firstDate":"2011-03-03","lastDate":"2021-05-26","metrics":{"ss":359,"delinquent":1305,"recentRows":18,"paidPenalty":57431.17,"proposedPenalty":622544,"currentAssessment":601295},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1407331","VIOLATION_NO":"8227756","ISSUE_DT":"05/26/2021","CFR_STANDARD_CD":"75.523-3(c)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1278.00","CURRENT_ASSESSMENT_AMT":"843.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-05-26"},{"SOURCE_ROW_NUMBER":"1407332","VIOLATION_NO":"9100931","ISSUE_DT":"05/24/2021","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"172.00","CURRENT_ASSESSMENT_AMT":"172.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-05-24"},{"SOURCE_ROW_NUMBER":"1963465","VIOLATION_NO":"6637511","ISSUE_DT":"03/11/2021","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"159.00","CURRENT_ASSESSMENT_AMT":"159.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"1963464","VIOLATION_NO":"6637510","ISSUE_DT":"03/11/2021","CFR_STANDARD_CD":"75.1103-5(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"257.00","CURRENT_ASSESSMENT_AMT":"257.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"1963463","VIOLATION_NO":"6637509","ISSUE_DT":"03/11/2021","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"416.00","CURRENT_ASSESSMENT_AMT":"229.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"1963462","VIOLATION_NO":"6637508","ISSUE_DT":"03/11/2021","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"1963461","VIOLATION_NO":"6637507","ISSUE_DT":"03/11/2021","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"1963460","VIOLATION_NO":"6637506","ISSUE_DT":"03/09/2021","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"416.00","CURRENT_ASSESSMENT_AMT":"229.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-03-09"},{"SOURCE_ROW_NUMBER":"1963459","VIOLATION_NO":"6637505","ISSUE_DT":"02/23/2021","CFR_STANDARD_CD":"75.1100-2(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-02-23"},{"SOURCE_ROW_NUMBER":"1963458","VIOLATION_NO":"6637504","ISSUE_DT":"02/23/2021","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-02-23"},{"SOURCE_ROW_NUMBER":"1963457","VIOLATION_NO":"6637503","ISSUE_DT":"02/19/2021","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"286.00","CURRENT_ASSESSMENT_AMT":"286.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-02-19"},{"SOURCE_ROW_NUMBER":"1963456","VIOLATION_NO":"6637502","ISSUE_DT":"02/09/2021","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-02-09"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":398,"firstDate":"2016-04-08","lastDate":"2021-12-01","metrics":{"appeals":0,"decisions":398,"recentRows":50,"decisionPenalty":83275,"originalPenalty":104875},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"428752","VIOLATION_NO":"9100931","DOCKET_NO":"KENT 2021-0114","DECISION_DT":"12/01/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"172.00","DECISION_PENALTY_AMT":"172.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2021-12-01"},{"SOURCE_ROW_NUMBER":"427609","VIOLATION_NO":"8227756","DOCKET_NO":"KENT 2021-0114","DECISION_DT":"12/01/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1278.00","DECISION_PENALTY_AMT":"843.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2021-12-01"},{"SOURCE_ROW_NUMBER":"428669","VIOLATION_NO":"6637506","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"416.00","DECISION_PENALTY_AMT":"229.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-08-20"},{"SOURCE_ROW_NUMBER":"427754","VIOLATION_NO":"6637508","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-08-20"},{"SOURCE_ROW_NUMBER":"427492","VIOLATION_NO":"6637507","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-08-20"},{"SOURCE_ROW_NUMBER":"426358","VIOLATION_NO":"6637509","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"416.00","DECISION_PENALTY_AMT":"229.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-08-20"},{"SOURCE_ROW_NUMBER":"148134","VIOLATION_NO":"6637511","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"159.00","DECISION_PENALTY_AMT":"159.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-08-20"},{"SOURCE_ROW_NUMBER":"147806","VIOLATION_NO":"6637510","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"257.00","DECISION_PENALTY_AMT":"257.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-08-20"},{"SOURCE_ROW_NUMBER":"147573","VIOLATION_NO":"6637503","DOCKET_NO":"KENT 2021-0083","DECISION_DT":"08/09/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"286.00","DECISION_PENALTY_AMT":"286.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-08-09"},{"SOURCE_ROW_NUMBER":"428044","VIOLATION_NO":"6637502","DOCKET_NO":"KENT 2021-0084","DECISION_DT":"07/30/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-07-30"},{"SOURCE_ROW_NUMBER":"427129","VIOLATION_NO":"6637504","DOCKET_NO":"KENT 2021-0084","DECISION_DT":"07/30/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-07-30"},{"SOURCE_ROW_NUMBER":"425991","VIOLATION_NO":"6637505","DOCKET_NO":"KENT 2021-0084","DECISION_DT":"07/30/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2021-07-30"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1164,"firstDate":"2010-02-09","lastDate":"2021-04-14","metrics":{"recentRows":39,"cpdmSamples":438,"voidSamples":211,"validSamples":953,"maxConcentration":3.322,"concentrationTotal":579.994},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"514634","CASS_NUM":"58396728","SMP_TAKEN_DT":"4/14/2021","CONC":".073","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-04-14"},{"SOURCE_ROW_NUMBER":"502196","CASS_NUM":"58396741","SMP_TAKEN_DT":"4/14/2021","CONC":".355","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-04-14"},{"SOURCE_ROW_NUMBER":"448326","CASS_NUM":"58396734","SMP_TAKEN_DT":"4/14/2021","CONC":".107","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-04-14"},{"SOURCE_ROW_NUMBER":"386541","CASS_NUM":"58396793","SMP_TAKEN_DT":"4/14/2021","CONC":".259","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-04-14"},{"SOURCE_ROW_NUMBER":"213473","CASS_NUM":"58396730","SMP_TAKEN_DT":"4/14/2021","CONC":".382","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-04-14"},{"SOURCE_ROW_NUMBER":"10488","CASS_NUM":"58396729","SMP_TAKEN_DT":"4/14/2021","CONC":".334","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-04-14"},{"SOURCE_ROW_NUMBER":"704433","CASS_NUM":"51574799","SMP_TAKEN_DT":"3/17/2021","CONC":".578","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-03-17"},{"SOURCE_ROW_NUMBER":"1624092","CASS_NUM":"51575149","SMP_TAKEN_DT":"3/16/2021","CONC":".64","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-03-16"},{"SOURCE_ROW_NUMBER":"429389","CASS_NUM":"58187586","SMP_TAKEN_DT":"3/16/2021","CONC":".286","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-03-16"},{"SOURCE_ROW_NUMBER":"790287","CASS_NUM":"51574802","SMP_TAKEN_DT":"3/15/2021","CONC":"1.776","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-03-15"},{"SOURCE_ROW_NUMBER":"216728","CASS_NUM":"51574808","SMP_TAKEN_DT":"3/12/2021","CONC":".477","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-03-12"},{"SOURCE_ROW_NUMBER":"373127","CASS_NUM":"51575144","SMP_TAKEN_DT":"3/11/2021","CONC":"1.301","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTAMINATED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-03-11"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":6,"firstDate":"2013-08-08","lastDate":"2015-04-21","metrics":{"linkedIssuances":6},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":398,"firstDate":"2015-08-03","lastDate":"2021-05-26","metrics":{"decisions":398,"ssChanged":59,"recentRows":18,"decisionPenalty":83275,"proposedPenalty":104875},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"387013","CITATION_NO":"8227756","CITATION_ISSUE_DT":"05/26/2021","DOCKET_NO":"KENT 2021-0114","DECISION_DT":"12/01/2021","CFR_STANDARD_CODE":"75.523-3(c)(2)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1278.00","DECISION_PENALTY_AMT":"843.00","sourceDate":"2021-05-26"},{"SOURCE_ROW_NUMBER":"48988","CITATION_NO":"9100931","CITATION_ISSUE_DT":"05/24/2021","DOCKET_NO":"KENT 2021-0114","DECISION_DT":"12/01/2021","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"172.00","DECISION_PENALTY_AMT":"172.00","sourceDate":"2021-05-24"},{"SOURCE_ROW_NUMBER":"392788","CITATION_NO":"6637509","CITATION_ISSUE_DT":"03/11/2021","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"416.00","DECISION_PENALTY_AMT":"229.00","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"392787","CITATION_NO":"6637507","CITATION_ISSUE_DT":"03/11/2021","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"161553","CITATION_NO":"6637511","CITATION_ISSUE_DT":"03/11/2021","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"159.00","DECISION_PENALTY_AMT":"159.00","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"103785","CITATION_NO":"6637510","CITATION_ISSUE_DT":"03/11/2021","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","CFR_STANDARD_CODE":"75.1103-5(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"257.00","DECISION_PENALTY_AMT":"257.00","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"47314","CITATION_NO":"6637508","CITATION_ISSUE_DT":"03/11/2021","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"218417","CITATION_NO":"6637506","CITATION_ISSUE_DT":"03/09/2021","DOCKET_NO":"KENT 2021-0095","DECISION_DT":"08/20/2021","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"416.00","DECISION_PENALTY_AMT":"229.00","sourceDate":"2021-03-09"},{"SOURCE_ROW_NUMBER":"386292","CITATION_NO":"6637504","CITATION_ISSUE_DT":"02/23/2021","DOCKET_NO":"KENT 2021-0084","DECISION_DT":"07/30/2021","CFR_STANDARD_CODE":"75.515","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","sourceDate":"2021-02-23"},{"SOURCE_ROW_NUMBER":"331437","CITATION_NO":"6637505","CITATION_ISSUE_DT":"02/23/2021","DOCKET_NO":"KENT 2021-0084","DECISION_DT":"07/30/2021","CFR_STANDARD_CODE":"75.1100-2(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","sourceDate":"2021-02-23"},{"SOURCE_ROW_NUMBER":"160427","CITATION_NO":"6637503","CITATION_ISSUE_DT":"02/19/2021","DOCKET_NO":"KENT 2021-0083","DECISION_DT":"08/09/2021","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"286.00","DECISION_PENALTY_AMT":"286.00","sourceDate":"2021-02-19"},{"SOURCE_ROW_NUMBER":"222933","CITATION_NO":"6637502","CITATION_ISSUE_DT":"02/09/2021","DOCKET_NO":"KENT 2021-0084","DECISION_DT":"07/30/2021","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","sourceDate":"2021-02-09"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":199,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":37,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":11,"firstDate":"1985-05-01","lastDate":"2015-03-12","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":9},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":114,"firstDate":"2010-03-10","lastDate":"2021-10-06","metrics":{"inspectors":306,"recentRows":4,"onSiteHours":6756,"inspectionHours":11287,"inspectionSamples":986},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1044556","EVENT_NO":"4417404","INSPECTION_BEGIN_DT":"10/06/2021","INSPECTION_END_DT":"12/09/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2021-10-06"},{"SOURCE_ROW_NUMBER":"632379","EVENT_NO":"4424941","INSPECTION_BEGIN_DT":"07/09/2021","INSPECTION_END_DT":"09/28/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"57.5","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2021-07-09"},{"SOURCE_ROW_NUMBER":"291511","EVENT_NO":"4424938","INSPECTION_BEGIN_DT":"04/01/2021","INSPECTION_END_DT":"06/17/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"199.5","SUM_TOTAL_ON_SITE_HOURS":"108.5","sourceDate":"2021-04-01"},{"SOURCE_ROW_NUMBER":"965860","EVENT_NO":"6398698","INSPECTION_BEGIN_DT":"01/08/2021","INSPECTION_END_DT":"03/22/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"251","SUM_TOTAL_ON_SITE_HOURS":"163.5","sourceDate":"2021-01-08"},{"SOURCE_ROW_NUMBER":"421896","EVENT_NO":"6398695","INSPECTION_BEGIN_DT":"10/01/2020","INSPECTION_END_DT":"12/18/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"236.25","SUM_TOTAL_ON_SITE_HOURS":"156.5","sourceDate":"2020-10-01"},{"SOURCE_ROW_NUMBER":"533513","EVENT_NO":"6398693","INSPECTION_BEGIN_DT":"07/01/2020","INSPECTION_END_DT":"09/28/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"315.5","SUM_TOTAL_ON_SITE_HOURS":"206","sourceDate":"2020-07-01"},{"SOURCE_ROW_NUMBER":"252906","EVENT_NO":"6398725","INSPECTION_BEGIN_DT":"03/25/2020","INSPECTION_END_DT":"06/25/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"379.25","SUM_TOTAL_ON_SITE_HOURS":"191","sourceDate":"2020-03-25"},{"SOURCE_ROW_NUMBER":"1031704","EVENT_NO":"6398722","INSPECTION_BEGIN_DT":"01/08/2020","INSPECTION_END_DT":"03/18/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"289","SUM_TOTAL_ON_SITE_HOURS":"177.75","sourceDate":"2020-01-08"},{"SOURCE_ROW_NUMBER":"58709","EVENT_NO":"6401617","INSPECTION_BEGIN_DT":"10/01/2019","INSPECTION_END_DT":"12/20/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"215.25","SUM_TOTAL_ON_SITE_HOURS":"140","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"306146","EVENT_NO":"6401541","INSPECTION_BEGIN_DT":"07/08/2019","INSPECTION_END_DT":"09/18/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"217","SUM_TOTAL_ON_SITE_HOURS":"136.25","sourceDate":"2019-07-08"},{"SOURCE_ROW_NUMBER":"327382","EVENT_NO":"6398337","INSPECTION_BEGIN_DT":"04/02/2019","INSPECTION_END_DT":"06/20/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"286.5","SUM_TOTAL_ON_SITE_HOURS":"174","sourceDate":"2019-04-02"},{"SOURCE_ROW_NUMBER":"420536","EVENT_NO":"6401181","INSPECTION_BEGIN_DT":"01/07/2019","INSPECTION_END_DT":"02/26/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"244.5","SUM_TOTAL_ON_SITE_HOURS":"156.25","sourceDate":"2019-01-07"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":96,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2022-Q1":{"hours":0,"employees":0,"production":0},"2021-Q3":{"hours":0,"employees":0,"production":0},"2021-Q2":{"hours":10491,"employees":14,"production":13462},"2021-Q1":{"hours":16448,"employees":28,"production":26814},"2020-Q4":{"hours":18120,"employees":28,"production":22679},"2020-Q3":{"hours":14310,"employees":27,"production":18597},"2020-Q2":{"hours":13283,"employees":28,"production":14067},"2020-Q1":{"hours":18936,"employees":29,"production":22856},"2019-Q4":{"hours":19528,"employees":29,"production":27612},"2019-Q3":{"hours":17018,"employees":28,"production":26731},"2019-Q2":{"hours":19648,"employees":28,"production":27613},"2019-Q1":{"hours":22856,"employees":29,"production":26381}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012":{"hours":41205,"employees":24,"production":47906},"2013":{"hours":32906,"employees":20,"production":45051},"2014":{"hours":45342,"employees":24,"production":57239},"2015":{"hours":76286,"employees":39,"production":124730},"2016":{"hours":50413,"employees":28,"production":97562},"2017":{"hours":57763,"employees":30,"production":103306},"2018":{"hours":60265,"employees":29,"production":93797},"2019":{"hours":79050,"employees":29,"production":108337},"2020":{"hours":64649,"employees":28,"production":78199},"2021":{"hours":26939,"employees":21,"production":40276}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":85,"firstDate":"2011-08-15","lastDate":"2020-11-18","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":3843,"pelDoseTotal":2538},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"51526","EVENT_NO":"6398695","SURVEY_DATE":"11/18/2020","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"30","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2020-11-18"},{"SOURCE_ROW_NUMBER":"51525","EVENT_NO":"6398695","SURVEY_DATE":"11/18/2020","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"32","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2020-11-18"},{"SOURCE_ROW_NUMBER":"51524","EVENT_NO":"6398695","SURVEY_DATE":"11/18/2020","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"82","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2020-11-18"},{"SOURCE_ROW_NUMBER":"51523","EVENT_NO":"6398695","SURVEY_DATE":"11/18/2020","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"59","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2020-11-18"},{"SOURCE_ROW_NUMBER":"51522","EVENT_NO":"6398695","SURVEY_DATE":"11/18/2020","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"34","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2020-11-18"},{"SOURCE_ROW_NUMBER":"51521","EVENT_NO":"6398695","SURVEY_DATE":"11/18/2020","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"56","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2020-11-18"},{"SOURCE_ROW_NUMBER":"51520","EVENT_NO":"6398695","SURVEY_DATE":"10/08/2020","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"10","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2020-10-08"},{"SOURCE_ROW_NUMBER":"51528","EVENT_NO":"6398722","SURVEY_DATE":"02/19/2020","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"16","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2020-02-19"},{"SOURCE_ROW_NUMBER":"51542","EVENT_NO":"6401617","SURVEY_DATE":"10/29/2019","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"5","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"51541","EVENT_NO":"6401617","SURVEY_DATE":"10/16/2019","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"59","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2019-10-16"},{"SOURCE_ROW_NUMBER":"51540","EVENT_NO":"6401617","SURVEY_DATE":"10/16/2019","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"83","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2019-10-16"},{"SOURCE_ROW_NUMBER":"51539","EVENT_NO":"6401617","SURVEY_DATE":"10/16/2019","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"58","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2019-10-16"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":44,"firstDate":"2013-07-29","lastDate":"2021-02-25","metrics":{"recentRows":1,"voidSamples":2,"maxQuartzPct":6.8,"validSamples":42,"quartzPctTotal":90.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"39296","CASSETTE_NO":"58381942","SAMPLE_DT":"02/25/2021","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-02-25"},{"SOURCE_ROW_NUMBER":"164921","CASSETTE_NO":"58381652","SAMPLE_DT":"11/18/2020","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-11-18"},{"SOURCE_ROW_NUMBER":"154651","CASSETTE_NO":"58203778","SAMPLE_DT":"11/18/2020","QUARTZ_PCT":"00.7","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-11-18"},{"SOURCE_ROW_NUMBER":"104942","CASSETTE_NO":"58382069","SAMPLE_DT":"08/19/2020","QUARTZ_PCT":"04.9","QUARTZ_MICROGRAMS":"19","OCC_CODE_DESC":"ROOF BOLTER (SINGLE HEAD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-08-19"},{"SOURCE_ROW_NUMBER":"60043","CASSETTE_NO":"58381979","SAMPLE_DT":"08/19/2020","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-08-19"},{"SOURCE_ROW_NUMBER":"88236","CASSETTE_NO":"58381211","SAMPLE_DT":"05/05/2020","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-05-05"},{"SOURCE_ROW_NUMBER":"27950","CASSETTE_NO":"58381342","SAMPLE_DT":"05/05/2020","QUARTZ_PCT":"03.9","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"ROOF BOLTER (SINGLE HEAD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-05-05"},{"SOURCE_ROW_NUMBER":"139266","CASSETTE_NO":"58275629","SAMPLE_DT":"03/11/2020","QUARTZ_PCT":"00.9","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-03-11"},{"SOURCE_ROW_NUMBER":"340","CASSETTE_NO":"58275615","SAMPLE_DT":"03/11/2020","QUARTZ_PCT":"00.4","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-03-11"},{"SOURCE_ROW_NUMBER":"118206","CASSETTE_NO":"58345615","SAMPLE_DT":"01/13/2020","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"13","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-01-13"},{"SOURCE_ROW_NUMBER":"112155","CASSETTE_NO":"58345619","SAMPLE_DT":"01/13/2020","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"ROOF BOLTER (SINGLE HEAD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-01-13"},{"SOURCE_ROW_NUMBER":"151666","CASSETTE_NO":"58275545","SAMPLE_DT":"12/04/2019","QUARTZ_PCT":"00.3","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-04"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1383,"firstDate":"2010-11-09","lastDate":"2021-05-26","metrics":{"ss":359,"amountDue":601295,"contested":0,"amountPaid":57431.17,"recentRows":18,"section104d":37,"unterminated":64,"proposedPenalty":622544},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"827568","VIOLATION_NO":"8227756","VIOLATION_ISSUE_DT":"05/26/2021","SIG_SUB":"Y","PART_SECTION":"75.523-3(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/26/2021","PROPOSED_PENALTY":"1278","AMOUNT_DUE":"843","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-05-26"},{"SOURCE_ROW_NUMBER":"827569","VIOLATION_NO":"9100931","VIOLATION_ISSUE_DT":"05/24/2021","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/24/2021","PROPOSED_PENALTY":"172","AMOUNT_DUE":"172","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-05-24"},{"SOURCE_ROW_NUMBER":"827439","VIOLATION_NO":"6637511","VIOLATION_ISSUE_DT":"03/11/2021","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/12/2021","PROPOSED_PENALTY":"159","AMOUNT_DUE":"159","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"827438","VIOLATION_NO":"6637510","VIOLATION_ISSUE_DT":"03/11/2021","SIG_SUB":"N","PART_SECTION":"75.1103-5(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/15/2021","PROPOSED_PENALTY":"257","AMOUNT_DUE":"257","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"827437","VIOLATION_NO":"6637509","VIOLATION_ISSUE_DT":"03/11/2021","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/12/2021","PROPOSED_PENALTY":"416","AMOUNT_DUE":"229","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"827436","VIOLATION_NO":"6637508","VIOLATION_ISSUE_DT":"03/11/2021","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/12/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"827435","VIOLATION_NO":"6637507","VIOLATION_ISSUE_DT":"03/11/2021","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/12/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-03-11"},{"SOURCE_ROW_NUMBER":"827434","VIOLATION_NO":"6637506","VIOLATION_ISSUE_DT":"03/09/2021","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/11/2021","PROPOSED_PENALTY":"416","AMOUNT_DUE":"229","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-03-09"},{"SOURCE_ROW_NUMBER":"827433","VIOLATION_NO":"6637505","VIOLATION_ISSUE_DT":"02/23/2021","SIG_SUB":"N","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/25/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-02-23"},{"SOURCE_ROW_NUMBER":"827432","VIOLATION_NO":"6637504","VIOLATION_ISSUE_DT":"02/23/2021","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/03/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-02-23"},{"SOURCE_ROW_NUMBER":"827431","VIOLATION_NO":"6637503","VIOLATION_ISSUE_DT":"02/19/2021","SIG_SUB":"N","SECTION_OF_ACT":"316(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/03/2021","PROPOSED_PENALTY":"286","AMOUNT_DUE":"286","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-02-19"},{"SOURCE_ROW_NUMBER":"827430","VIOLATION_NO":"6637502","VIOLATION_ISSUE_DT":"02/09/2021","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-02-09"}]}],"safety":{"href":"/api/v1/mines/1515215/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1515215/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-5","heading":"Automatic fire warning devices; actions and response.","id":"75.1103-5","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-5","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) When the carbon monoxide level reaches 10 parts per million above the established ambient level at any sensor location, automatic fire sensor and warning device systems shall provide an effective warning signal at the following locations:\n\n(1) At working sections and other work locations where miners may be endangered from a fire in the belt entry.\n\n(2) At a manned surface location where personnel have an assigned post of duty. The manned surface location must have:\n\n(i) A telephone or equivalent communication with all miners who may be endangered and\n\n(ii) A map or schematic that shows the locations of sensors, and the intended air flow direction at these locations. This map or schematic must be updated within 24 hours of any change in this information.\n\n(3) The automatic fire sensor and warning device system shall be monitored for a period of 4 hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in § 75.1103-4(e).\n\n(b) The fire sensor and warning device system shall include a means for rapid evaluation of electrical short and open circuits, ground faults, pneumatic leaks, or other defect detrimental to its proper operational condition.\n\n(c) Automatic fire sensor and warning devices shall include a manual reset feature.\n\n(d) When a malfunction or warning signal is received at the manned surface location, the sensors that are activated must be identified and appropriate personnel immediately notified.\n\n(e) Upon notification of a malfunction or warning signal, appropriate personnel must immediately initiate an investigation to determine the cause of the malfunction or warning signal and take the required actions set forth in paragraph (f) of this section.\n\n(f) If any sensor indicates a warning, the following actions must be taken unless the mine operator determines that the signal does not present a hazard to miners:\n\n(1) Appropriate personnel must notify miners in affected working sections, in affected areas where mechanized mining equipment is being installed or removed, and at other locations specified in the approved mine emergency evacuation and firefighting program of instruction; and\n\n(2) All miners in the affected areas, unless assigned emergency response duties, must be immediately withdrawn to a safe location identified in the mine emergency evacuation and firefighting program of instruction.\n\n(g) If the warning signal will be activated during calibration of sensors, personnel manning the surface location must be notified prior to and upon completion of calibration. Affected working sections, areas where mechanized mining equipment is being installed or removed, or other areas designated in the approved emergency evacuation and firefighting program of instruction must be notified at the beginning and completion of calibration.\n\n(h) If any fire detection component becomes inoperative, immediate action must be taken to repair the component. While repairs are being made, operation of the belt may continue if the following requirements are met:\n\n(1) If one sensor becomes inoperative, a trained person must continuously monitor for carbon monoxide at the inoperative sensor;\n\n(2) If two or more adjacent sensors become inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety. Alternatively, a trained person must be stationed at each inoperative sensor to monitor for carbon monoxide;\n\n(3) If the complete fire detection system becomes inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety;\n\n(4) Trained persons who conduct monitoring under this section must have two-way voice communication capability, at intervals not to exceed 2,000 feet, and must report carbon monoxide concentrations to the surface at intervals not to exceed one hour;\n\n(5) Trained persons who conduct monitoring under this section must immediately report to the surface any concentration of carbon monoxide that reaches 10 parts per million above the established ambient level, unless the mine operator knows that the source of the carbon monoxide does not present a hazard to miners; and\n\n(6) Handheld detectors used to monitor the belt entry under this section must have a detection level equivalent to that of the system's carbon monoxide sensors.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1515215","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}