{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1507201","name":"C-2","status":"Temporarily Idled","status_date":"2024-02-06","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Harlan","nearest_town":"Dione","operator_id":"P00008","operator_name":"Harlan Cumberland Coal Company LLC","controller_id":"C15915","controller_name":"Joseph T  Bennett","district":"C07","office":"Harlan KY Field Office","employees":0,"latitude":36.9375,"longitude":-83.090833},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":4235},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1507201","name":"C-2"},"operator":{"type":"operator","id":"P00008","name":"Harlan Cumberland Coal Company LLC"},"controller":{"type":"controller","id":"C15915","name":"Joseph T  Bennett"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00008","name":"Harlan Cumberland Coal Company LLC"},"object":{"type":"mine","id":"1507201","name":"C-2"},"validFrom":"1974-08-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1507201|P00008|1974-08-14|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15915","name":"Joseph T  Bennett  et al"},"object":{"type":"mine","id":"1507201","name":"C-2"},"validFrom":"1974-08-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1507201|C15915|1974-08-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15915","name":"Joseph T  Bennett  et al"},"object":{"type":"operator","id":"P00008","name":"Harlan Cumberland Coal Company LLC"},"validFrom":"1974-08-14","validTo":null,"current":true,"derived":true,"evidenceMineId":"1507201","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1507201|P00008|1974-08-14|C15915|1974-08-14|97578"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":46,"firstDate":"2000-04-19","lastDate":"2014-12-08","metrics":{"daysLost":1172,"injuries":42,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"212017","DOCUMENT_NO":"220143630008","ACCIDENT_DT":"12/08/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was hit in the mouth with a jack, knocked out tooth.","sourceDate":"2014-12-08"},{"SOURCE_ROW_NUMBER":"31387","DOCUMENT_NO":"220141490010","ACCIDENT_DT":"05/27/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"274","NARRATIVE":"Contract employee pulled shoulder and neck muscle while removing a bar from a belt roller.","sourceDate":"2014-05-27"},{"SOURCE_ROW_NUMBER":"130020","DOCUMENT_NO":"220120130043","ACCIDENT_DT":"12/27/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"126","NARRATIVE":"Ee was on his knees changing a bottom roller.  When he reached for the roller his back \"gave out\".  He is still off work as of 1-12-12 and in physical therapy.","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"160410","DOCUMENT_NO":"220120130041","ACCIDENT_DT":"11/11/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"This ocurrence was a spider bit.  Ee finally had to go to a doctor.  Had to take two days off.  Back to work with no problems or restrictions.","sourceDate":"2011-11-11"},{"SOURCE_ROW_NUMBER":"143183","DOCUMENT_NO":"220110770012","ACCIDENT_DT":"03/08/2011","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"26","NARRATIVE":"EE has been diagnosed with carpal tunnel.","sourceDate":"2011-03-08"},{"SOURCE_ROW_NUMBER":"198998","DOCUMENT_NO":"220110350016","ACCIDENT_DT":"02/02/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was cutting a coupling.  He accidentally stabbed himself in the leg.  It required 4 stitches.  He only missed a few hours work.","sourceDate":"2011-02-02"},{"SOURCE_ROW_NUMBER":"31386","DOCUMENT_NO":"220100470074","ACCIDENT_DT":"02/08/2010","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"The foreman discovered a rock fall on the belt line during the pre-shift.  It was on the #1 belt flight at the #10 cross cut on the #2 entry.  The fall was approx 35' long, 25' wide and 8' thick.  This fall was at an intersection. The foreman reported to the safety director at approx 6:10 am.","sourceDate":"2010-02-08"},{"SOURCE_ROW_NUMBER":"91444","DOCUMENT_NO":"220082800001","ACCIDENT_DT":"09/11/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"The crew was lifting the belt rope to install new bottom structure, when ee's back \"went out\".  He was diagnosed with muscle strain and came back to work in six days.","sourceDate":"2008-09-11"},{"SOURCE_ROW_NUMBER":"48534","DOCUMENT_NO":"220031490021","ACCIDENT_DT":"05/12/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE WAS EXITING BELT, HIT A PIECE OF 2\" PIPE AND BRUISED HIS LEFT FOOT. THIS OCCURRED ON 5-12, BUT EE WORKED UNTIL 5-17-03 BEFORE GOING TO DOCTOR. HE MISSED TWO DAYS WORK.","sourceDate":"2003-05-12"},{"SOURCE_ROW_NUMBER":"212016","DOCUMENT_NO":"220031120005","ACCIDENT_DT":"04/07/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL OCCURRED IN THE #2 PANEL ON FAN ENTRY DIRECTLY IN FRONT OF FAN HOUSE. THE FALL MEASURED APPROX. 16'WIDE, 25'LONG, & 0-3'THICK. THE PRE-SHIFT MINE EXAMINER WAS CONDUCTING HIS CHECK S WHEN THE FALL OCCURRED.","sourceDate":"2003-04-07"},{"SOURCE_ROW_NUMBER":"164706","DOCUMENT_NO":"220022760007","ACCIDENT_DT":"09/27/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","NARRATIVE":"EE STEPPED ON A CAP BOARD THAT HAD A NAIL IN IT. THE NAIL WAS BIG ENOUGH TO PENETRATE BOOT AND FOOT. EE DID NOT MISS ANY WORK, BUT DID GO TO DOCTOR'S OFFICE TO GET A TETANUS SHOT.","sourceDate":"2002-09-27"},{"SOURCE_ROW_NUMBER":"52843","DOCUMENT_NO":"220022320034","ACCIDENT_DT":"08/13/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Contact with electrical current","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"EE WAS HANGING CAR CABLE AND GRABBED A BARE LEAD. HE CONTINUED WORKING FOR MOST OF HIS SHIFT BUT THEN DECIDED TO GO TO HOSPITAL. TESTS WERE RUN, NO PROBLEMS FOUND. HE WENT BACK TO WORK THE NEX T DAY.","sourceDate":"2002-08-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2024-02-06","lastDate":"2024-02-06","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":687,"firstDate":"2000-03-10","lastDate":"2020-09-01","metrics":{"ss":187,"delinquent":673,"recentRows":0,"paidPenalty":59662.85,"proposedPenalty":133928,"currentAssessment":127814.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1482445","VIOLATION_NO":"9138118","ISSUE_DT":"09/01/2020","CFR_STANDARD_CD":"75.1711-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"1483176","VIOLATION_NO":"9138001","ISSUE_DT":"06/30/2020","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-06-30"},{"SOURCE_ROW_NUMBER":"1483698","VIOLATION_NO":"8536664","ISSUE_DT":"11/26/2019","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-11-26"},{"SOURCE_ROW_NUMBER":"1479719","VIOLATION_NO":"9138735","ISSUE_DT":"09/04/2019","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-04"},{"SOURCE_ROW_NUMBER":"1479689","VIOLATION_NO":"9135192","ISSUE_DT":"03/28/2019","CFR_STANDARD_CD":"75.364(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-03-28"},{"SOURCE_ROW_NUMBER":"1475596","VIOLATION_NO":"9135184","ISSUE_DT":"03/12/2019","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"474.00","CURRENT_ASSESSMENT_AMT":"474.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-03-12"},{"SOURCE_ROW_NUMBER":"2000497","VIOLATION_NO":"9133206","ISSUE_DT":"05/31/2018","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-05-31"},{"SOURCE_ROW_NUMBER":"2000495","VIOLATION_NO":"8372988","ISSUE_DT":"05/31/2018","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-05-31"},{"SOURCE_ROW_NUMBER":"2000496","VIOLATION_NO":"9133205","ISSUE_DT":"05/30/2018","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-05-30"},{"SOURCE_ROW_NUMBER":"1475321","VIOLATION_NO":"9131851","ISSUE_DT":"02/27/2018","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-02-27"},{"SOURCE_ROW_NUMBER":"1475320","VIOLATION_NO":"9131850","ISSUE_DT":"02/27/2018","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"163.00","CURRENT_ASSESSMENT_AMT":"163.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-02-27"},{"SOURCE_ROW_NUMBER":"1475319","VIOLATION_NO":"9131849","ISSUE_DT":"02/27/2018","CFR_STANDARD_CD":"77.410(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-02-27"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":200,"firstDate":"2000-05-01","lastDate":"2015-03-11","metrics":{"appeals":0,"decisions":200,"recentRows":0,"decisionPenalty":30344.5,"originalPenalty":38204},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"363701","VIOLATION_NO":"8387001","DOCKET_NO":"KENT 2015-0002","DECISION_DT":"03/11/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"370.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2015-03-11"},{"SOURCE_ROW_NUMBER":"107620","VIOLATION_NO":"8387018","DOCKET_NO":"KENT 2014-0639","DECISION_DT":"12/04/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"333.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2014-12-04"},{"SOURCE_ROW_NUMBER":"356269","VIOLATION_NO":"8386745","DOCKET_NO":"KENT 2014-0380","DECISION_DT":"08/20/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"150.00","DECISION_PENALTY_AMT":"150.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"349103","VIOLATION_NO":"8386659","DOCKET_NO":"KENT 2014-38","DECISION_DT":"04/30/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"399.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2014-04-30"},{"SOURCE_ROW_NUMBER":"349066","VIOLATION_NO":"8386664","DOCKET_NO":"KENT 2013-1040","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"100723","VIOLATION_NO":"8386665","DOCKET_NO":"KENT 2013-1040","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"745.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"319578","VIOLATION_NO":"8348363","DOCKET_NO":"KENT 2012-686","DECISION_DT":"09/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-09-12"},{"SOURCE_ROW_NUMBER":"83556","VIOLATION_NO":"8348707","DOCKET_NO":"KENT 2012-685","DECISION_DT":"08/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"176.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-08-26"},{"SOURCE_ROW_NUMBER":"80287","VIOLATION_NO":"8348307","DOCKET_NO":"KENT 2012-329","DECISION_DT":"11/19/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"314684","VIOLATION_NO":"8348301","DOCKET_NO":"KENT 2012-330","DECISION_DT":"11/06/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-11-06"},{"SOURCE_ROW_NUMBER":"314444","VIOLATION_NO":"8348297","DOCKET_NO":"KENT 2012-330","DECISION_DT":"11/06/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-11-06"},{"SOURCE_ROW_NUMBER":"314271","VIOLATION_NO":"8401264","DOCKET_NO":"KENT 2012-330","DECISION_DT":"11/06/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-11-06"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":604,"firstDate":"2000-01-25","lastDate":"2018-02-08","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":19,"validSamples":585,"maxConcentration":49.688,"concentrationTotal":356.207},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1655883","CASS_NUM":"58283354","SMP_TAKEN_DT":"2/8/2018","CONC":".021","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-02-08"},{"SOURCE_ROW_NUMBER":"954877","CASS_NUM":"58283191","SMP_TAKEN_DT":"2/8/2018","CONC":".183","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MINE FOREMAN/MINE MANAGER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-02-08"},{"SOURCE_ROW_NUMBER":"1569253","CASS_NUM":"58283484","SMP_TAKEN_DT":"2/7/2018","CONC":".145","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-02-07"},{"SOURCE_ROW_NUMBER":"1498211","CASS_NUM":"58283241","SMP_TAKEN_DT":"2/7/2018","CONC":".131","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL SAMPLER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-02-07"},{"SOURCE_ROW_NUMBER":"333578","CASS_NUM":"58283438","SMP_TAKEN_DT":"2/7/2018","CONC":".075","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-02-07"},{"SOURCE_ROW_NUMBER":"317529","CASS_NUM":"58283253","SMP_TAKEN_DT":"2/7/2018","CONC":".025","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WEIGHMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-02-07"},{"SOURCE_ROW_NUMBER":"964067","CASS_NUM":"58283381","SMP_TAKEN_DT":"12/12/2017","CONC":".038","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-12-12"},{"SOURCE_ROW_NUMBER":"371390","CASS_NUM":"58283134","SMP_TAKEN_DT":"12/12/2017","CONC":".038","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-12-12"},{"SOURCE_ROW_NUMBER":"221905","CASS_NUM":"58283526","SMP_TAKEN_DT":"12/12/2017","CONC":".112","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-12-12"},{"SOURCE_ROW_NUMBER":"1507581","CASS_NUM":"58284364","SMP_TAKEN_DT":"6/19/2017","CONC":".414","SMP_TYPE_CD_DESC":"NONDESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BELT MAN/CONVEYOR MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-06-19"},{"SOURCE_ROW_NUMBER":"1318537","CASS_NUM":"58284372","SMP_TAKEN_DT":"6/19/2017","CONC":".084","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-06-19"},{"SOURCE_ROW_NUMBER":"619484","CASS_NUM":"58284608","SMP_TAKEN_DT":"6/19/2017","CONC":".298","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-06-19"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":20,"firstDate":"2000-05-18","lastDate":"2020-11-06","metrics":{"linkedIssuances":20},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":75,"firstDate":"2004-09-08","lastDate":"2014-04-28","metrics":{"decisions":75,"ssChanged":3,"recentRows":0,"decisionPenalty":12199.5,"proposedPenalty":13228},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"374481","CITATION_NO":"8387018","CITATION_ISSUE_DT":"04/28/2014","DOCKET_NO":"KENT 2014-0639","DECISION_DT":"12/04/2014","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"333.00","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"203188","CITATION_NO":"8387001","CITATION_ISSUE_DT":"03/05/2014","DOCKET_NO":"KENT 2015-0002","DECISION_DT":"03/11/2015","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"370.00","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"88433","CITATION_NO":"8386745","CITATION_ISSUE_DT":"12/12/2013","DOCKET_NO":"KENT 2014-0380","DECISION_DT":"08/20/2014","CFR_STANDARD_CODE":"75.1403-5(g)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"150.00","DECISION_PENALTY_AMT":"150.00","sourceDate":"2013-12-12"},{"SOURCE_ROW_NUMBER":"311165","CITATION_NO":"8386665","CITATION_ISSUE_DT":"06/19/2013","DOCKET_NO":"KENT 2013-1040","DECISION_DT":"03/05/2014","CFR_STANDARD_CODE":"75.1501(a)(3)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"745.00","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"32186","CITATION_NO":"8386664","CITATION_ISSUE_DT":"06/19/2013","DOCKET_NO":"KENT 2013-1040","DECISION_DT":"03/05/2014","CFR_STANDARD_CODE":"77.400(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"258328","CITATION_NO":"8386659","CITATION_ISSUE_DT":"06/13/2013","DOCKET_NO":"KENT 2014-38","DECISION_DT":"04/30/2014","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"399.00","sourceDate":"2013-06-13"},{"SOURCE_ROW_NUMBER":"426126","CITATION_NO":"8348363","CITATION_ISSUE_DT":"12/28/2011","DOCKET_NO":"KENT 2012-686","DECISION_DT":"09/12/2013","CFR_STANDARD_CODE":"75.364(h)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2011-12-28"},{"SOURCE_ROW_NUMBER":"425623","CITATION_NO":"8348707","CITATION_ISSUE_DT":"12/19/2011","DOCKET_NO":"KENT 2012-685","DECISION_DT":"08/26/2013","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"176.00","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"365829","CITATION_NO":"8348318","CITATION_ISSUE_DT":"10/18/2011","DOCKET_NO":"KENT 2012-542","DECISION_DT":"10/24/2012","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"425.00","sourceDate":"2011-10-18"},{"SOURCE_ROW_NUMBER":"419724","CITATION_NO":"8348307","CITATION_ISSUE_DT":"09/16/2011","DOCKET_NO":"KENT 2012-329","DECISION_DT":"11/19/2012","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","sourceDate":"2011-09-16"},{"SOURCE_ROW_NUMBER":"24233","CITATION_NO":"8348306","CITATION_ISSUE_DT":"09/15/2011","DOCKET_NO":"KENT 2012-978","DECISION_DT":"07/10/2012","CFR_STANDARD_CODE":"75.360(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"150.00","DECISION_PENALTY_AMT":"150.00","sourceDate":"2011-09-15"},{"SOURCE_ROW_NUMBER":"252987","CITATION_NO":"8348305","CITATION_ISSUE_DT":"09/14/2011","DOCKET_NO":"KENT 2012-330","DECISION_DT":"11/06/2012","CFR_STANDARD_CODE":"77.1104","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2011-09-14"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1020,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":12,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":208,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":11,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1974-08-14","lastDate":"1974-08-14","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":227,"firstDate":"2000-01-31","lastDate":"2026-09-14","metrics":{"inspectors":355,"recentRows":22,"onSiteHours":5666.75,"inspectionHours":8922,"inspectionSamples":593},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"168549","EVENT_NO":"F014A1D","INSPECTION_BEGIN_DT":"09/14/2026","INSPECTION_END_DT":"09/14/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"536018","EVENT_NO":"F02B8A5","INSPECTION_BEGIN_DT":"06/17/2026","INSPECTION_END_DT":"06/17/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2026-06-17"},{"SOURCE_ROW_NUMBER":"336037","EVENT_NO":"F000E1A","INSPECTION_BEGIN_DT":"02/24/2026","INSPECTION_END_DT":"02/24/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2026-02-24"},{"SOURCE_ROW_NUMBER":"77421","EVENT_NO":"F003CE1","INSPECTION_BEGIN_DT":"12/03/2025","INSPECTION_END_DT":"12/03/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2025-12-03"},{"SOURCE_ROW_NUMBER":"754047","EVENT_NO":"F0306E8","INSPECTION_BEGIN_DT":"09/02/2025","INSPECTION_END_DT":"09/02/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2025-09-02"},{"SOURCE_ROW_NUMBER":"9849","EVENT_NO":"F000E00","INSPECTION_BEGIN_DT":"05/20/2025","INSPECTION_END_DT":"05/20/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2025-05-20"},{"SOURCE_ROW_NUMBER":"1143173","EVENT_NO":"6973661","INSPECTION_BEGIN_DT":"02/24/2025","INSPECTION_END_DT":"02/24/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2025-02-24"},{"SOURCE_ROW_NUMBER":"941224","EVENT_NO":"F000DEA","INSPECTION_BEGIN_DT":"11/29/2024","INSPECTION_END_DT":"11/29/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2024-11-29"},{"SOURCE_ROW_NUMBER":"622635","EVENT_NO":"7021406","INSPECTION_BEGIN_DT":"09/20/2024","INSPECTION_END_DT":"09/20/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2024-09-20"},{"SOURCE_ROW_NUMBER":"523417","EVENT_NO":"7021484","INSPECTION_BEGIN_DT":"06/20/2024","INSPECTION_END_DT":"06/20/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2024-06-20"},{"SOURCE_ROW_NUMBER":"508346","EVENT_NO":"7036184","INSPECTION_BEGIN_DT":"03/20/2024","INSPECTION_END_DT":"03/20/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2024-03-20"},{"SOURCE_ROW_NUMBER":"1083358","EVENT_NO":"7036198","INSPECTION_BEGIN_DT":"08/01/2023","INSPECTION_END_DT":"08/01/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2023-08-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":250,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2020-Q2":{"hours":55,"employees":1,"production":0},"2020-Q1":{"hours":1468,"employees":2,"production":0},"2019-Q4":{"hours":2760,"employees":5,"production":0},"2019-Q3":{"hours":2419,"employees":5,"production":0},"2019-Q2":{"hours":3015,"employees":5,"production":0},"2019-Q1":{"hours":3090,"employees":5,"production":0},"2018-Q4":{"hours":2701,"employees":5,"production":0},"2018-Q3":{"hours":3429,"employees":5,"production":0},"2018-Q2":{"hours":4601,"employees":6,"production":0},"2018-Q1":{"hours":5092,"employees":7,"production":0},"2017-Q4":{"hours":4357,"employees":16,"production":0},"2017-Q3":{"hours":4838,"employees":25,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":56,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":43904,"employees":20,"production":0},"2012":{"hours":23823,"employees":8,"production":0},"2013":{"hours":20476,"employees":6,"production":0},"2014":{"hours":12687,"employees":9,"production":0},"2015":{"hours":9948,"employees":16,"production":0},"2016":{"hours":22157,"employees":26,"production":0},"2017":{"hours":20364,"employees":21,"production":0},"2018":{"hours":15823,"employees":6,"production":0},"2019":{"hours":11284,"employees":5,"production":0},"2020":{"hours":1523,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":98,"firstDate":"2000-01-31","lastDate":"2018-02-07","metrics":{"recentRows":0,"doseOver100":6,"actDoseTotal":4141,"pelDoseTotal":2678},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"41966","EVENT_NO":"4454929","SURVEY_DATE":"02/07/2018","OCCUPATION_CD_DESC":"CARPENTER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"14","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2018-02-07"},{"SOURCE_ROW_NUMBER":"41965","EVENT_NO":"4454929","SURVEY_DATE":"02/07/2018","OCCUPATION_CD_DESC":"COAL SAMPLER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"11","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2018-02-07"},{"SOURCE_ROW_NUMBER":"41964","EVENT_NO":"4454929","SURVEY_DATE":"02/07/2018","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"10","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2018-02-07"},{"SOURCE_ROW_NUMBER":"41989","EVENT_NO":"6429875","SURVEY_DATE":"12/12/2017","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"8","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2017-12-12"},{"SOURCE_ROW_NUMBER":"41988","EVENT_NO":"6429875","SURVEY_DATE":"12/12/2017","OCCUPATION_CD_DESC":"MINE FOREMAN/MINE MANAGER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"9","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2017-12-12"},{"SOURCE_ROW_NUMBER":"41987","EVENT_NO":"6429875","SURVEY_DATE":"12/12/2017","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"6","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2017-12-12"},{"SOURCE_ROW_NUMBER":"41986","EVENT_NO":"6429875","SURVEY_DATE":"12/12/2017","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"12","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2017-12-12"},{"SOURCE_ROW_NUMBER":"41985","EVENT_NO":"6429875","SURVEY_DATE":"12/12/2017","OCCUPATION_CD_DESC":"SUPERINTENDENT","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2017-12-12"},{"SOURCE_ROW_NUMBER":"41963","EVENT_NO":"4454067","SURVEY_DATE":"12/08/2016","OCCUPATION_CD_DESC":"COAL SAMPLER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"14","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2016-12-08"},{"SOURCE_ROW_NUMBER":"41962","EVENT_NO":"4454067","SURVEY_DATE":"12/08/2016","OCCUPATION_CD_DESC":"WEIGHMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"37","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2016-12-08"},{"SOURCE_ROW_NUMBER":"42000","EVENT_NO":"6430351","SURVEY_DATE":"07/26/2016","OCCUPATION_CD_DESC":"COAL SAMPLER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2016-07-26"},{"SOURCE_ROW_NUMBER":"41999","EVENT_NO":"6430351","SURVEY_DATE":"07/26/2016","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"47","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2016-07-26"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":42,"firstDate":"2000-01-25","lastDate":"2018-02-07","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":9.2,"validSamples":42,"quartzPctTotal":240.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"42928","CASSETTE_NO":"58283484","SAMPLE_DT":"02/07/2018","QUARTZ_PCT":"03.5","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-02-07"},{"SOURCE_ROW_NUMBER":"20073","CASSETTE_NO":"58256186","SAMPLE_DT":"03/07/2017","QUARTZ_PCT":"02.3","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-03-07"},{"SOURCE_ROW_NUMBER":"39470","CASSETTE_NO":"58240287","SAMPLE_DT":"04/29/2016","QUARTZ_PCT":"05.3","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"UTILITY MAN","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-04-29"},{"SOURCE_ROW_NUMBER":"64277","CASSETTE_NO":"57459546","SAMPLE_DT":"05/13/2003","QUARTZ_PCT":"06.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-05-13"},{"SOURCE_ROW_NUMBER":"131952","CASSETTE_NO":"50680593","SAMPLE_DT":"03/28/2003","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-03-28"},{"SOURCE_ROW_NUMBER":"21778","CASSETTE_NO":"57469037","SAMPLE_DT":"01/29/2003","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-01-29"},{"SOURCE_ROW_NUMBER":"48541","CASSETTE_NO":"57413950","SAMPLE_DT":"02/05/2002","QUARTZ_PCT":"08.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-05"},{"SOURCE_ROW_NUMBER":"133117","CASSETTE_NO":"57403382","SAMPLE_DT":"12/11/2001","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-11"},{"SOURCE_ROW_NUMBER":"11252","CASSETTE_NO":"50611506","SAMPLE_DT":"11/28/2001","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"167508","CASSETTE_NO":"57387362","SAMPLE_DT":"11/27/2001","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-27"},{"SOURCE_ROW_NUMBER":"32150","CASSETTE_NO":"57387301","SAMPLE_DT":"11/27/2001","QUARTZ_PCT":"08.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-27"},{"SOURCE_ROW_NUMBER":"121301","CASSETTE_NO":"57369489","SAMPLE_DT":"08/23/2001","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-08-23"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":699,"firstDate":"2000-03-10","lastDate":"2021-01-27","metrics":{"ss":187,"amountDue":127814.5,"contested":132,"amountPaid":59662.85,"recentRows":1,"section104d":0,"unterminated":5,"proposedPenalty":133928},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"763539","VIOLATION_NO":"4762391","VIOLATION_ISSUE_DT":"01/27/2021","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","CONTESTED_IND":"N","sourceDate":"2021-01-27"},{"SOURCE_ROW_NUMBER":"763984","VIOLATION_NO":"9138118","VIOLATION_ISSUE_DT":"09/01/2020","SIG_SUB":"N","PART_SECTION":"75.1711-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"123","CONTESTED_IND":"N","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"763848","VIOLATION_NO":"9138001","VIOLATION_ISSUE_DT":"06/30/2020","SIG_SUB":"N","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"123","CONTESTED_IND":"N","sourceDate":"2020-06-30"},{"SOURCE_ROW_NUMBER":"764115","VIOLATION_NO":"8536664","VIOLATION_ISSUE_DT":"11/26/2019","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/26/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"69.34","CONTESTED_IND":"N","sourceDate":"2019-11-26"},{"SOURCE_ROW_NUMBER":"763983","VIOLATION_NO":"9138735","VIOLATION_ISSUE_DT":"09/04/2019","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/10/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-09-04"},{"SOURCE_ROW_NUMBER":"763662","VIOLATION_NO":"9135192","VIOLATION_ISSUE_DT":"03/28/2019","SIG_SUB":"N","PART_SECTION":"75.364(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/28/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-03-28"},{"SOURCE_ROW_NUMBER":"763561","VIOLATION_NO":"9135184","VIOLATION_ISSUE_DT":"03/12/2019","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/25/2019","PROPOSED_PENALTY":"474","AMOUNT_DUE":"474","AMOUNT_PAID":"474","CONTESTED_IND":"N","sourceDate":"2019-03-12"},{"SOURCE_ROW_NUMBER":"763792","VIOLATION_NO":"9133206","VIOLATION_ISSUE_DT":"05/31/2018","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/13/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-05-31"},{"SOURCE_ROW_NUMBER":"763790","VIOLATION_NO":"8372988","VIOLATION_ISSUE_DT":"05/31/2018","SIG_SUB":"N","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/13/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-05-31"},{"SOURCE_ROW_NUMBER":"763791","VIOLATION_NO":"9133205","VIOLATION_ISSUE_DT":"05/30/2018","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/11/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-05-30"},{"SOURCE_ROW_NUMBER":"763538","VIOLATION_NO":"9131851","VIOLATION_ISSUE_DT":"02/27/2018","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/28/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-02-27"},{"SOURCE_ROW_NUMBER":"763537","VIOLATION_NO":"9131850","VIOLATION_ISSUE_DT":"02/27/2018","SIG_SUB":"Y","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/27/2018","PROPOSED_PENALTY":"163","AMOUNT_DUE":"163","AMOUNT_PAID":"163","CONTESTED_IND":"N","sourceDate":"2018-02-27"}]}],"safety":{"href":"/api/v1/mines/1507201/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1507201/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","heading":"Openings of active mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711-3","part":"75","subchapter":"O","subpart":"R","id":"75.1711-3","citation":"30 CFR 75.1711-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1507201","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}