{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1502709","name":"Henderson County Mine","status":"Active","status_date":"2023-07-05","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Henderson","nearest_town":"Corydon, KY","operator_id":"0072463","operator_name":"River View Coal LLC","controller_id":"C15455","controller_name":"Alliance Resource Partners LP","district":"C10","office":"Sturgis KY Field Office","employees":461,"latitude":37.697222,"longitude":-87.724167},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":46498},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"operator":{"type":"operator","id":"0072463","name":"River View Coal LLC"},"controller":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P01154","name":"Peabody Coal Company"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"1950-01-01","validTo":"1977-06-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|P01154|1950-01-01|1977-06-30"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00991","name":"Kennecott Copper Corp"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"1950-01-01","validTo":"1977-06-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|C00991|1950-01-01|1977-06-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00991","name":"Kennecott Copper Corp"},"object":{"type":"operator","id":"P01154","name":"Peabody Coal Company"},"validFrom":"1950-01-01","validTo":"1977-06-30","current":false,"derived":true,"evidenceMineId":"1502709","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|P01154|1950-01-01|C00991|1950-01-01|51450"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|C05313|1950-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P06396","name":"Peabody Coal Company"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"1977-07-01","validTo":"1998-05-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|P06396|1977-07-01|1998-05-18"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"operator","id":"P06396","name":"Peabody Coal Company"},"validFrom":"1977-07-01","validTo":"1998-05-18","current":false,"derived":true,"evidenceMineId":"1502709","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|P06396|1977-07-01|C05313|1950-01-01|68220"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24509","name":"Highland Mining Company LLC"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"1998-05-19","validTo":"2015-09-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|P24509|1998-05-19|2015-09-27"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"1998-05-19","validTo":"2007-10-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|C15833|1998-05-19|2007-10-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P24509","name":"Highland Mining Company LLC"},"validFrom":"1998-05-19","validTo":"2007-10-30","current":false,"derived":true,"evidenceMineId":"1502709","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|P24509|1998-05-19|C15833|1998-05-19|96956"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"2006-05-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|C15455|2006-05-31|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"2007-10-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|0071611|2007-10-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"operator","id":"P24509","name":"Highland Mining Company LLC"},"validFrom":"2007-10-31","validTo":"2015-09-27","current":false,"derived":true,"evidenceMineId":"1502709","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|P24509|1998-05-19|0071611|2007-10-31|10268"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0141013","name":"Prairie Mining Company, LLC"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"2015-09-28","validTo":"2016-01-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|0141013|2015-09-28|2016-01-18"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0120441","name":"Richard J  Robinson et al"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"2015-09-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|0120441|2015-09-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0120441","name":"Richard J  Robinson et al"},"object":{"type":"operator","id":"0141013","name":"Prairie Mining Company, LLC"},"validFrom":"2015-09-28","validTo":"2016-01-18","current":false,"derived":true,"evidenceMineId":"1502709","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|0141013|2015-09-28|0120441|2015-09-28|23504"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0120441","name":"Ben  Statler et al"},"object":{"type":"operator","id":"0141013","name":"Prairie Mining Company, LLC"},"validFrom":"2015-09-28","validTo":"2016-01-18","current":false,"derived":true,"evidenceMineId":"1502709","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|0141013|2015-09-28|0120441|2015-09-28|23505"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0143915","name":"UC Mining, LLC"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"2016-01-19","validTo":"2023-03-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|0143915|2016-01-19|2023-03-27"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"2016-01-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|C15455|2016-01-19|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"operator","id":"0143915","name":"UC Mining, LLC"},"validFrom":"2016-01-19","validTo":"2023-03-27","current":false,"derived":true,"evidenceMineId":"1502709","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|0143915|2016-01-19|C15455|2016-01-19|95686"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0072463","name":"River View Coal LLC"},"object":{"type":"mine","id":"1502709","name":"Henderson County Mine"},"validFrom":"2023-03-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|0072463|2023-03-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"operator","id":"0072463","name":"River View Coal LLC"},"validFrom":"2023-03-28","validTo":null,"current":true,"derived":true,"evidenceMineId":"1502709","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1502709|0072463|2023-03-28|C15455|2006-05-31|95673"}}],"coverage":{"historyRecords":8,"edgeCount":21,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":824,"firstDate":"2000-01-10","lastDate":"2026-09-22","metrics":{"daysLost":20657,"injuries":574,"fatalities":2,"recentRows":85,"restrictedDays":89,"contractorRecords":33},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"147502","DOCUMENT_NO":"220262740029","ACCIDENT_DT":"09/22/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"Employee was walking out of a crosscut when they struck their head on high voltage cable, jamming their neck. EE was taken to the ER where x-rays were negative for fractures but was taken off work due to restrictions preventing them from performing their normal job.","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"143160","DOCUMENT_NO":"220262740027","ACCIDENT_DT":"09/22/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee was installing a roof bolt when it bent. As they tried to straighten it, they accidentally hit the rotation causing the bent roof bolt to strike their right hand.  Employee was taken to the ER where x-rays revealed a fracture and they were taken off work due to restrictions.","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"233503","DOCUMENT_NO":"220262650010","ACCIDENT_DT":"09/09/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee was reaching for supplies on top of the bolter when EE's right foot was ran over by the rear tire. EE finished EE's shift but saw a physician the next day where x-rays revealed a fracture and EE was taken off work due to restrictions.","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"78648","DOCUMENT_NO":"220262510006","ACCIDENT_DT":"08/24/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was cutting open a package with a utility knife when it slipped causing a laceration to the little finger on EE's left hand. EE was taken to the ER where EE received seven sutures and a full release with no restrictions to return EE's next shift.","sourceDate":"2026-08-24"},{"SOURCE_ROW_NUMBER":"207670","DOCUMENT_NO":"220262510009","ACCIDENT_DT":"08/20/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"Employee was hanging curtain when EE slipped and fell, twisting EE's right knee. EE finished EE's shift but missed 8/21 to see a physician. EE was given a full release with no restrictions. EE continued working until 8/26 when EE was taken off due to pain and waiting for results of MRI. Returned 9/1 with no restrictions.","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"9841","DOCUMENT_NO":"220262380007","ACCIDENT_DT":"08/13/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating continuous miner when something flew back striking EE in the right side of EE's face. EE was treated at the ER where EE received two sutures and a full release with no restrictions to return EE's next shift.","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"65610","DOCUMENT_NO":"220262380008","ACCIDENT_DT":"08/12/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","NARRATIVE":"Employee was loading a car at the face when a piece of draw rock fell between the rib and the pin striking EE on the head. EE finished EE's shift but was sore the next morning, so EE was seen at the ER where EE was taken off work due to pain and restrictions preventing EE from performing EE's normal job.","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"52821","DOCUMENT_NO":"220262380004","ACCIDENT_DT":"08/12/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","NARRATIVE":"Employee had walked away from EE's shuttle car when EE stepped awkwardly, twisting EE's right knee. EE was seen at the ER where EE was taken off work due to restrictions preventing EE from performing EE's regular job.","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"117176","DOCUMENT_NO":"220262310022","ACCIDENT_DT":"08/06/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee was reaching for pins on the roof bolter, when the bolter trammed forward running over their right foot.  Employee was treated at the ER where they were taken off work for restrictions preventing them from performing their normal duties.","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"198976","DOCUMENT_NO":"220262290008","ACCIDENT_DT":"08/04/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee was lifting roof bolts to put on pinner when EE felt pain in EE's left shoulder. EE finished EE's shift but was hurting the next day. EE was seen by a physician who gave EE restrictions preventing EE from performing EE's normal duties.","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"168927","DOCUMENT_NO":"220262290006","ACCIDENT_DT":"08/04/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"As employee was drilling a hole for a pin, the rock fractured and a piece fell out striking EE's right ankle. EE finished EE's shift but went to the ER afterwards where x-rays revealed a fracture. EE was taken off work due to restrictions preventing EE from performing EE's normal job.","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"216314","DOCUMENT_NO":"220262190002","ACCIDENT_DT":"07/31/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While drilling a hole, EE stopped EE's rotation while still applying upward pressure causing the pinner steel to break and strike EE in the forehead. EE was treated at the ER where EE received six sutures and a full release with no restrictions to return to EE's regular duties.","sourceDate":"2026-07-31"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2023-07-05","lastDate":"2023-07-05","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":8200,"firstDate":"2000-01-04","lastDate":"2026-08-14","metrics":{"ss":2462,"delinquent":7895,"recentRows":653,"paidPenalty":5465564.93,"proposedPenalty":8829437,"currentAssessment":6257935},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2975154","VIOLATION_NO":"9760824","ISSUE_DT":"08/14/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-14"},{"SOURCE_ROW_NUMBER":"2975132","VIOLATION_NO":"5045247","ISSUE_DT":"08/14/2026","CFR_STANDARD_CD":"75.333(c)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-14"},{"SOURCE_ROW_NUMBER":"2975138","VIOLATION_NO":"5047895","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2975137","VIOLATION_NO":"5047894","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2975136","VIOLATION_NO":"5047893","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2975131","VIOLATION_NO":"5045246","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"2975116","VIOLATION_NO":"5044305","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.1909(b)(5)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"2975115","VIOLATION_NO":"5044304","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"336.00","CURRENT_ASSESSMENT_AMT":"336.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"2975130","VIOLATION_NO":"5045245","ISSUE_DT":"08/10/2026","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"2975135","VIOLATION_NO":"5047892","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2312.00","CURRENT_ASSESSMENT_AMT":"2312.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2975134","VIOLATION_NO":"5047891","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.606","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"642.00","CURRENT_ASSESSMENT_AMT":"642.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2975133","VIOLATION_NO":"5047890","ISSUE_DT":"08/04/2026","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"465.00","CURRENT_ASSESSMENT_AMT":"465.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-04"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2280,"firstDate":"2001-08-13","lastDate":"2026-08-18","metrics":{"appeals":0,"decisions":2257,"recentRows":30,"decisionPenalty":4140703,"originalPenalty":6806844},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"461038","VIOLATION_NO":"5044385","DOCKET_NO":"KENT 2026-0028","DECISION_DT":"08/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"245.00","DECISION_PENALTY_AMT":"197.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"461037","VIOLATION_NO":"5044373","DOCKET_NO":"KENT 2026-0028","DECISION_DT":"08/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"465.00","DECISION_PENALTY_AMT":"273.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"460916","VIOLATION_NO":"5044372","DOCKET_NO":"KENT 2026-0028","DECISION_DT":"08/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"465.00","DECISION_PENALTY_AMT":"273.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"460745","VIOLATION_NO":"5044371","DOCKET_NO":"KENT 2026-0028","DECISION_DT":"08/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1818.00","DECISION_PENALTY_AMT":"909.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"460744","VIOLATION_NO":"5044213","DOCKET_NO":"KENT 2026-0028","DECISION_DT":"08/18/2026","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"288.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"458011","VIOLATION_NO":"9760421","DOCKET_NO":"KENT 2025-0111","DECISION_DT":"06/10/2026","DECISION_TYPE_CODE_DESC":"Vacate","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-10"},{"SOURCE_ROW_NUMBER":"457834","VIOLATION_NO":"9760253","DOCKET_NO":"KENT 2025-0111","DECISION_DT":"06/10/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"168.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-10"},{"SOURCE_ROW_NUMBER":"457942","VIOLATION_NO":"9760040","DOCKET_NO":"KENT 2025-0086","DECISION_DT":"02/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4047.00","DECISION_PENALTY_AMT":"3238.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"457217","VIOLATION_NO":"9769761","DOCKET_NO":"KENT 2025-0086","DECISION_DT":"02/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"168.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"456665","VIOLATION_NO":"9760033","DOCKET_NO":"KENT 2025-0086","DECISION_DT":"02/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"959.00","DECISION_PENALTY_AMT":"959.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"456492","VIOLATION_NO":"9769771","DOCKET_NO":"KENT 2025-0086","DECISION_DT":"02/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"755.00","DECISION_PENALTY_AMT":"168.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"163705","VIOLATION_NO":"9769304","DOCKET_NO":"KENT 2025-0048","DECISION_DT":"05/13/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"172.00","DECISION_PENALTY_AMT":"172.00","JUDGE_FIRST_NAME":"Glynn","JUDGE_LAST_NAME":"Voisin","sourceDate":"2025-05-13"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":11675,"firstDate":"2000-01-05","lastDate":"2071-10-16","metrics":{"recentRows":5133,"cpdmSamples":4559,"voidSamples":1339,"validSamples":10336,"maxConcentration":41.314,"concentrationTotal":10502.474},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1195133","CASS_NUM":"51000068","SMP_TAKEN_DT":"10/16/2071","CONC":".7","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2071-10-16"},{"SOURCE_ROW_NUMBER":"2688630","SMP_TAKEN_DT":"10/8/2026","CONC":".995","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2517717","SMP_TAKEN_DT":"10/8/2026","CONC":".941","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2517679","SMP_TAKEN_DT":"10/8/2026","CONC":"1.254","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2347228","SMP_TAKEN_DT":"10/8/2026","CONC":".852","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2347226","SMP_TAKEN_DT":"10/8/2026","CONC":".672","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"1836471","SMP_TAKEN_DT":"10/8/2026","CONC":".736","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2859503","SMP_TAKEN_DT":"10/7/2026","CONC":".707","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2603599","SMP_TAKEN_DT":"10/7/2026","CONC":".821","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2517831","SMP_TAKEN_DT":"10/7/2026","CONC":".945","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2432339","SMP_TAKEN_DT":"10/7/2026","CONC":".817","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2262487","SMP_TAKEN_DT":"10/7/2026","CONC":"1.146","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1185,"firstDate":"2000-05-23","lastDate":"2015-12-28","metrics":{"linkedIssuances":1185},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":2251,"firstDate":"2003-01-22","lastDate":"2026-07-28","metrics":{"decisions":2228,"ssChanged":489,"recentRows":51,"decisionPenalty":4132780,"proposedPenalty":6815791},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"337368","CITATION_NO":"5221140","CITATION_ISSUE_DT":"07/28/2026","DOCKET_NO":"KENT 2026-0113","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3448.00","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"450322","CITATION_NO":"5044297","CITATION_ISSUE_DT":"07/23/2026","DOCKET_NO":"KENT 2026-0113","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"959.00","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"336525","CITATION_NO":"5221139","CITATION_ISSUE_DT":"07/23/2026","DOCKET_NO":"KENT 2026-0113","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"374.00","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"54269","CITATION_NO":"5044298","CITATION_ISSUE_DT":"07/23/2026","DOCKET_NO":"KENT 2026-0113","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"959.00","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"110361","CITATION_NO":"5044294","CITATION_ISSUE_DT":"07/21/2026","DOCKET_NO":"KENT 2026-0113","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"432.00","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"54267","CITATION_NO":"5045242","CITATION_ISSUE_DT":"07/21/2026","DOCKET_NO":"KENT 2026-0113","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1037.00","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"336665","CITATION_NO":"5044764","CITATION_ISSUE_DT":"07/20/2026","DOCKET_NO":"KENT 2026-0113","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"549.00","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"336624","CITATION_NO":"5044765","CITATION_ISSUE_DT":"07/20/2026","DOCKET_NO":"KENT 2026-0113","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"549.00","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"54268","CITATION_NO":"5044766","CITATION_ISSUE_DT":"07/20/2026","DOCKET_NO":"KENT 2026-0113","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"549.00","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"110264","CITATION_NO":"5047885","CITATION_ISSUE_DT":"06/11/2026","DOCKET_NO":"KENT 2026-0102","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"959.00","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"224981","CITATION_NO":"5047881","CITATION_ISSUE_DT":"05/21/2026","DOCKET_NO":"KENT 2026-0102","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"755.00","sourceDate":"2026-05-21"},{"SOURCE_ROW_NUMBER":"280215","CITATION_NO":"5044276","CITATION_ISSUE_DT":"05/18/2026","DOCKET_NO":"KENT 2026-0102","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"504.00","sourceDate":"2026-05-18"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":7629,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":39,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":1463,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":37,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":8,"firstDate":"1950-01-01","lastDate":"2023-03-28","metrics":{"recentRows":1,"currentOperatorTenures":1,"completedOperatorTenures":7},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":635,"firstDate":"2000-01-03","lastDate":"2026-10-01","metrics":{"inspectors":1728,"recentRows":45,"onSiteHours":51964,"inspectionHours":71336.5,"inspectionSamples":3702},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"819387","EVENT_NO":"F014706","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"112","SUM_TOTAL_ON_SITE_HOURS":"81","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"59460","EVENT_NO":"F00AE99","INSPECTION_BEGIN_DT":"09/24/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"40","SUM_TOTAL_ON_SITE_HOURS":"26","sourceDate":"2026-09-24"},{"SOURCE_ROW_NUMBER":"1009319","EVENT_NO":"F00100D","INSPECTION_BEGIN_DT":"09/03/2026","INSPECTION_END_DT":"09/04/2026","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"560719","EVENT_NO":"F016158","INSPECTION_BEGIN_DT":"07/02/2026","INSPECTION_END_DT":"09/23/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"17","SUM_TOTAL_INSP_HOURS":"1547.5","SUM_TOTAL_ON_SITE_HOURS":"1057.75","sourceDate":"2026-07-02"},{"SOURCE_ROW_NUMBER":"1138684","EVENT_NO":"F00F577","INSPECTION_BEGIN_DT":"06/24/2026","INSPECTION_END_DT":"07/06/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"74.5","SUM_TOTAL_ON_SITE_HOURS":"53.5","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"162303","EVENT_NO":"F00F81F","INSPECTION_BEGIN_DT":"04/01/2026","INSPECTION_END_DT":"06/24/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"17","SUM_TOTAL_INSP_HOURS":"1878.5","SUM_TOTAL_ON_SITE_HOURS":"1298","sourceDate":"2026-04-01"},{"SOURCE_ROW_NUMBER":"123370","EVENT_NO":"F00EA25","INSPECTION_BEGIN_DT":"02/06/2026","INSPECTION_END_DT":"02/06/2026","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2026-02-06"},{"SOURCE_ROW_NUMBER":"697739","EVENT_NO":"7102071","INSPECTION_BEGIN_DT":"01/02/2026","INSPECTION_END_DT":"03/25/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"14","SUM_TOTAL_INSP_HOURS":"1412.75","SUM_TOTAL_ON_SITE_HOURS":"946","sourceDate":"2026-01-02"},{"SOURCE_ROW_NUMBER":"1122302","EVENT_NO":"F022461","INSPECTION_BEGIN_DT":"12/30/2025","INSPECTION_END_DT":"12/30/2025","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2025-12-30"},{"SOURCE_ROW_NUMBER":"77994","EVENT_NO":"7102068","INSPECTION_BEGIN_DT":"12/19/2025","INSPECTION_END_DT":"12/22/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2025-12-19"},{"SOURCE_ROW_NUMBER":"959965","EVENT_NO":"7040703","INSPECTION_BEGIN_DT":"10/01/2025","INSPECTION_END_DT":"12/17/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"16","SUM_TOTAL_INSP_HOURS":"1387.25","SUM_TOTAL_ON_SITE_HOURS":"906.75","sourceDate":"2025-10-01"},{"SOURCE_ROW_NUMBER":"1108411","EVENT_NO":"F017A52","INSPECTION_BEGIN_DT":"09/25/2025","INSPECTION_END_DT":"09/25/2025","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2025-09-25"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":281,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":300604,"employees":465,"production":1897509},"2026-Q1":{"hours":258943,"employees":452,"production":1680851},"2025-Q4":{"hours":191623,"employees":379,"production":1128171},"2025-Q3":{"hours":118196,"employees":260,"production":475873},"2025-Q2":{"hours":114351,"employees":182,"production":535949},"2025-Q1":{"hours":95925,"employees":169,"production":391485},"2024-Q4":{"hours":70600,"employees":120,"production":46281},"2024-Q3":{"hours":69040,"employees":119,"production":18465},"2024-Q2":{"hours":69857,"employees":103,"production":145747},"2024-Q1":{"hours":57446,"employees":89,"production":43793},"2023-Q4":{"hours":45618,"employees":75,"production":77890},"2023-Q3":{"hours":24575,"employees":32,"production":48759}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":52,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012":{"hours":1079470,"employees":467,"production":3950732},"2013":{"hours":989532,"employees":425,"production":2931435},"2014":{"hours":1017455,"employees":401,"production":2732081},"2015":{"hours":63504,"employees":53,"production":0},"2019":{"hours":568,"employees":1,"production":0},"2022":{"hours":3757,"employees":3,"production":0},"2023":{"hours":92261,"employees":34,"production":126649},"2024":{"hours":266943,"employees":108,"production":254286},"2025":{"hours":520095,"employees":248,"production":2531478},"2026":{"hours":559547,"employees":459,"production":3578360}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":764,"firstDate":"2000-02-29","lastDate":"2026-09-16","metrics":{"recentRows":162,"doseOver100":204,"actDoseTotal":57739,"pelDoseTotal":44409},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"39825","EVENT_NO":"F016158","SURVEY_DATE":"09/16/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"87","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"39824","EVENT_NO":"F016158","SURVEY_DATE":"09/16/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"92","PEL_DOSE_90":"73","SURVEY_TYPE":"I","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"39823","EVENT_NO":"F016158","SURVEY_DATE":"09/16/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"57","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"39822","EVENT_NO":"F016158","SURVEY_DATE":"09/16/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"77","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"39821","EVENT_NO":"F016158","SURVEY_DATE":"09/16/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"103","PEL_DOSE_90":"70","SURVEY_TYPE":"I","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"39800","EVENT_NO":"F016158","SURVEY_DATE":"09/11/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"17","ACT_DOSE_85":"4","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-09-11"},{"SOURCE_ROW_NUMBER":"39799","EVENT_NO":"F016158","SURVEY_DATE":"09/11/2026","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"39","ACT_DOSE_85":"32","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2026-09-11"},{"SOURCE_ROW_NUMBER":"39798","EVENT_NO":"F016158","SURVEY_DATE":"09/11/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"18","ACT_DOSE_85":"6","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2026-09-11"},{"SOURCE_ROW_NUMBER":"39820","EVENT_NO":"F016158","SURVEY_DATE":"09/02/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"75","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"39819","EVENT_NO":"F016158","SURVEY_DATE":"09/02/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"96","PEL_DOSE_90":"81","SURVEY_TYPE":"I","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"39818","EVENT_NO":"F016158","SURVEY_DATE":"09/02/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"116","PEL_DOSE_90":"99","SURVEY_TYPE":"I","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"39817","EVENT_NO":"F016158","SURVEY_DATE":"09/02/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"79","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2026-09-02"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":880,"firstDate":"2000-01-05","lastDate":"2026-10-02","metrics":{"recentRows":292,"voidSamples":9,"maxQuartzPct":10.6,"validSamples":871,"quartzPctTotal":1131.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"133729","CASSETTE_NO":"58547986","SAMPLE_DT":"10/02/2026","QUARTZ_PCT":"02.4","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"131831","CASSETTE_NO":"58547795","SAMPLE_DT":"10/02/2026","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"123480","CASSETTE_NO":"58547862","SAMPLE_DT":"10/02/2026","QUARTZ_PCT":"00.7","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"119312","CASSETTE_NO":"58547874","SAMPLE_DT":"10/02/2026","QUARTZ_PCT":"00.2","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"68738","CASSETTE_NO":"58547870","SAMPLE_DT":"10/02/2026","QUARTZ_PCT":"01.2","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"58584","CASSETTE_NO":"58547942","SAMPLE_DT":"10/02/2026","QUARTZ_PCT":"00.5","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"11476","CASSETTE_NO":"58547869","SAMPLE_DT":"10/02/2026","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"23","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"163266","CASSETTE_NO":"58547920","SAMPLE_DT":"10/01/2026","QUARTZ_PCT":"01.0","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"123032","CASSETTE_NO":"58547977","SAMPLE_DT":"10/01/2026","QUARTZ_PCT":"00.4","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"120254","CASSETTE_NO":"58547976","SAMPLE_DT":"10/01/2026","QUARTZ_PCT":"00.4","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"81647","CASSETTE_NO":"58547883","SAMPLE_DT":"10/01/2026","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"76569","CASSETTE_NO":"58547982","SAMPLE_DT":"10/01/2026","QUARTZ_PCT":"00.4","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-01"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":8369,"firstDate":"2000-01-04","lastDate":"2026-10-08","metrics":{"ss":2474,"amountDue":6257935,"contested":1458,"amountPaid":5465564.93,"recentRows":710,"section104d":47,"unterminated":7,"proposedPenalty":8829437},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"743332","VIOLATION_NO":"5045800","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"743329","VIOLATION_NO":"5044638","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.1722(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"743335","VIOLATION_NO":"5048103","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.380(d)(4)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"743334","VIOLATION_NO":"5048102","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"743333","VIOLATION_NO":"5048101","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.333(c)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"743331","VIOLATION_NO":"5045799","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"743328","VIOLATION_NO":"5044637","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.1600-3(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"743327","VIOLATION_NO":"5044636","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"743330","VIOLATION_NO":"5045798","VIOLATION_ISSUE_DT":"10/01/2026","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/01/2026","CONTESTED_IND":"N","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"741776","VIOLATION_NO":"5045264","VIOLATION_ISSUE_DT":"09/16/2026","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/16/2026","CONTESTED_IND":"N","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"741747","VIOLATION_NO":"5044635","VIOLATION_ISSUE_DT":"09/16/2026","SIG_SUB":"N","PART_SECTION":"75.360(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2026","CONTESTED_IND":"N","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"741743","VIOLATION_NO":"5044318","VIOLATION_ISSUE_DT":"09/16/2026","SIG_SUB":"N","PART_SECTION":"75.606","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2026","CONTESTED_IND":"N","sourceDate":"2026-09-16"}]}],"safety":{"href":"/api/v1/mines/1502709/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1502709/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":108,"companyType":"Operating Subsidiary","components":[{"averageEmployees":108,"laborHours":266943,"mineType":"Underground","productionTons":254286}],"county":"Union","laborHours":266943,"mineName":"Henderson County Mine","mineType":"Underground","mshaId":"1502709","operatingAddress":"530 French Rd, Waverly, KY 42462","operatingCompany":"River View Coal Llc","operationType":"Mine only","productionTons":254286,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Kentucky (West)","status":"Active","supplyRegion":"Illinois Basin","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1600-3","heading":"Communications facilities; refuge alternatives.","id":"75.1600-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-Q/section-75.1600-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Communications","text":"(a) Refuge alternatives shall be provided with a communications system that consists of—\n\n(1) A two-way communication facility that is a part of the mine communication system, which can be used from inside the refuge alternative; and\n\n(2) An additional communication system and other requirements as defined in the communications portion of the operator's approved Emergency Response Plan.\n\n[73 FR 80700, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.606","heading":"Protection of trailing cables.","id":"75.606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.606","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nTrailing cables shall be adequately protected to prevent damage by mobile equipment.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1502709","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}