{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"1202294","name":"Miller Creek Mine-Jenlin Pit","status":"Abandoned","status_date":"2007-05-10","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IN","county":"Clay","nearest_town":"Centerpoint","operator_id":"P23854","operator_name":"Peabody Midwest Mining, LLC","controller_id":"C15833","controller_name":"Peabody Energy Corporation","district":"C08","office":"Vincennes IN Field Office","employees":0,"latitude":39.357777,"longitude":-87.120833},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":1105},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1202294","name":"Miller Creek Mine-Jenlin Pit"},"operator":{"type":"operator","id":"P23854","name":"Peabody Midwest Mining, LLC"},"controller":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"1202294","name":"Miller Creek Mine-Jenlin Pit"},"validFrom":"1997-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1202294|C15833|1997-11-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23854","name":"Peabody Midwest Mining, LLC"},"object":{"type":"mine","id":"1202294","name":"Miller Creek Mine-Jenlin Pit"},"validFrom":"2000-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1202294|P23854|2000-09-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P23854","name":"Peabody Midwest Mining, LLC"},"validFrom":"2000-09-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1202294","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1202294|P23854|2000-09-01|C15833|1997-11-01|96928"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":8,"firstDate":"2001-10-01","lastDate":"2005-10-02","metrics":{"daysLost":349,"injuries":8,"fatalities":0,"recentRows":0,"restrictedDays":8,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"121353","DOCUMENT_NO":"220052840019","ACCIDENT_DT":"10/02/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EMPLOYEE WAS WALKING FROM TRUCK TO BUS WHEN SHE TRIPPED OVER OWN FOOT AND FELL, HURTING LEFT WRIST","sourceDate":"2005-10-02"},{"SOURCE_ROW_NUMBER":"48322","DOCUMENT_NO":"220022540011","ACCIDENT_DT":"08/30/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Truck driver","NO_INJURIES":"1","DAYS_LOST":"206","NARRATIVE":"EE WAS BEING LOADED BY A CAT 992D FRONT END LOADER AND CLAIMED THAT A LARGE ROCK WAS DROPPED IN THE BED OF THE END DUMP HE WAS DRIVING. THE LARGE ROCK CAUSED THE TRUCK TO SHIFT. EE CLAIMS THAT WHEN TRUCK SHIFTED HE TWISTED HIS BACK.","sourceDate":"2002-08-30"},{"SOURCE_ROW_NUMBER":"207533","DOCUMENT_NO":"220022540010","ACCIDENT_DT":"08/23/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Truck driver","NO_INJURIES":"1","DAYS_LOST":"98","NARRATIVE":"EE WAS DIAGNOSED WITH DEGERATIVE DISK DISEASE WITH EXACERBATION. THIS EE IS AN END DUMP DRIVER AND THE PHYSICIAN CONCLUDED THAT DRIVING THE END DUMP AGGRAVATED HER LOWER BACK AND RECOMMENDED T HAT SHE NOT DRIVE THE END DUM UNTIL SHE IMPROVES","sourceDate":"2002-08-23"},{"SOURCE_ROW_NUMBER":"87073","DOCUMENT_NO":"220022100144","ACCIDENT_DT":"07/22/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"EE WAS REPAIRING A CAT 785 END DUMP FRAME WHEN AN ERRANT PIECE OF METAL FROM A CO-WORKER'S GRINDER LODGED IN HIS LEFT EYE. HE WAS STANDING WITH HIS BACK TO THE CO-WORKER'S GRINDING AND HE WAS ALSO WEARING CUTTING GLASSES. DISCOMFORT WAS MILD AT FIRST AND THEN BECAME WORSE. HE WAS SEEN AT THE E.R. WHERE PHYSICIAN REMOVED OBJECT AND PRESCRIBED EYE DROPS.","sourceDate":"2002-07-22"},{"SOURCE_ROW_NUMBER":"78510","DOCUMENT_NO":"220021820062","ACCIDENT_DT":"06/17/2002","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Truck driver","NO_INJURIES":"1","DAYS_LOST":"45","NARRATIVE":"ON 6-17-02 EE NOTIFIED HER PIT SUPERVISOR THAT SHE HIT A BUMP IN THE HAUL ROAD AND STRUCK HER LEFT KNEE ON THE STEERING COLUMN OF THE CAT 785 END DRUM SHE WAS DRIVING EE WAS TRANSPORTED TO THE CENTER FOR OCCUPATIONAL HEALTH IN THE ENGINEERING TEC PICK TRUCK SO PROF. CAR COULD BE ADMINSTERED. DR EXAMINED EE'S KNEE AND HE RELEASED HER TO RETURN TO WORK ON 6-18-02 WITH RESTRICTED DUTY","sourceDate":"2002-06-17"},{"SOURCE_ROW_NUMBER":"207532","DOCUMENT_NO":"220021480154","ACCIDENT_DT":"05/13/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE WAS RESIZING HYDRAULIC HOSE ENDS. PIN RELEASED FROM HOSE IT PINCHED LEFT THUMB BETWEEN HOSE END AND RESIZING PIN CREATING A LACERATION ON THE LEFT THUMB.","sourceDate":"2002-05-13"},{"SOURCE_ROW_NUMBER":"56887","DOCUMENT_NO":"220013230017","ACCIDENT_DT":"11/13/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"INJURED WAS JUMP STARTING A LIGHT PLANT WITH JUMPER CABLES HOOKED FROM THE WELDER ON A SER- VICE TRUCK TO THE BATTERY OF A LIGHT PLANT. AS HE DISCONNECTED THE JUMPER CABLES FROM THE LIGHT PLANT BATTERY IT ARKED, CAUSING THE BATTERY TO EXPLODE. HE HAD CHEMICAL EXPOSURE TO HIS (R) EYEAND FACE. HE WAS TAKEN TO THE HOSPITAL(ER) WHEREHE WAS EXAMINED. RELEASED BACK TO WORK W/O RESTR","sourceDate":"2001-11-13"},{"SOURCE_ROW_NUMBER":"87072","DOCUMENT_NO":"220012880086","ACCIDENT_DT":"10/01/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Truck driver","NO_INJURIES":"1","NARRATIVE":"ON 10-01-01 SHE WAS DISMOUNTING FROM THE WATER TRUCK AND TWISTED HER RIGHT ANKLE. AT THAT TIME THE REPORTED INJURY WAS TREATED AS A FIRST AID CASE. ON 10-2-01, SHE WAS TAKEN TO THE CENTER FOR OCCUPATIONAL HEALTH AND EXAMINED BY DR. HER ANKLE WAS X RAYED, THE RESULTS WERE POSITVE CHIP FRACTURE. SHE WAS REFERRED TO THE APS SPORTS CLINIC, FOR APPT SHE WAS SEEN DR AND WAS RELEASE TO RE","sourceDate":"2001-10-01"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-05-10","lastDate":"2007-05-10","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":118,"firstDate":"2001-01-22","lastDate":"2006-09-28","metrics":{"ss":32,"delinquent":95,"recentRows":0,"paidPenalty":17786,"proposedPenalty":17786,"currentAssessment":17786},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1170783","VIOLATION_NO":"7493947","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170782","VIOLATION_NO":"7493946","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170781","VIOLATION_NO":"7493945","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170780","VIOLATION_NO":"7493944","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170779","VIOLATION_NO":"7493943","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170778","VIOLATION_NO":"7493942","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"723.00","CURRENT_ASSESSMENT_AMT":"723.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170777","VIOLATION_NO":"7493941","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.1713(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170776","VIOLATION_NO":"7493940","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170775","VIOLATION_NO":"7493939","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"723.00","CURRENT_ASSESSMENT_AMT":"723.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170774","VIOLATION_NO":"7493938","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170773","VIOLATION_NO":"7493937","ISSUE_DT":"09/28/2006","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1170627","VIOLATION_NO":"7486971","ISSUE_DT":"02/07/2006","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-02-07"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":20,"firstDate":"2001-10-17","lastDate":"2006-03-29","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":20,"maxConcentration":0.381,"concentrationTotal":2.997},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1358237","CASS_NUM":"57620590","SMP_TAKEN_DT":"3/29/2006","CONC":".102","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"848703","CASS_NUM":"57620613","SMP_TAKEN_DT":"3/29/2006","CONC":".166","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"594126","CASS_NUM":"57620681","SMP_TAKEN_DT":"3/29/2006","CONC":".15","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"325930","CASS_NUM":"57620625","SMP_TAKEN_DT":"3/29/2006","CONC":".148","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"39412","CASS_NUM":"57620673","SMP_TAKEN_DT":"3/29/2006","CONC":".044","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"1459412","CASS_NUM":"57564263","SMP_TAKEN_DT":"9/21/2005","CONC":".05","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-21"},{"SOURCE_ROW_NUMBER":"996141","CASS_NUM":"57564197","SMP_TAKEN_DT":"9/21/2005","CONC":".037","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROAD GRADER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-21"},{"SOURCE_ROW_NUMBER":"765751","CASS_NUM":"57564240","SMP_TAKEN_DT":"9/21/2005","CONC":".099","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-21"},{"SOURCE_ROW_NUMBER":"711588","CASS_NUM":"57564212","SMP_TAKEN_DT":"9/21/2005","CONC":".15","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-21"},{"SOURCE_ROW_NUMBER":"427700","CASS_NUM":"57564196","SMP_TAKEN_DT":"9/21/2005","CONC":".162","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-21"},{"SOURCE_ROW_NUMBER":"1181176","CASS_NUM":"57424595","SMP_TAKEN_DT":"10/7/2002","CONC":".381","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"1020399","CASS_NUM":"57424617","SMP_TAKEN_DT":"10/7/2002","CONC":".082","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-10-07"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":7,"firstDate":"2004-08-04","lastDate":"2005-10-18","metrics":{"linkedIssuances":7},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":601,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":147,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2000-09-01","lastDate":"2000-09-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":31,"firstDate":"2000-11-29","lastDate":"2006-09-28","metrics":{"inspectors":37,"recentRows":0,"onSiteHours":411.25,"inspectionHours":676,"inspectionSamples":5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"627923","EVENT_NO":"4245929","INSPECTION_BEGIN_DT":"09/28/2006","INSPECTION_END_DT":"09/28/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"60940","EVENT_NO":"4245901","INSPECTION_BEGIN_DT":"02/01/2006","INSPECTION_END_DT":"03/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"52","SUM_TOTAL_ON_SITE_HOURS":"31","sourceDate":"2006-02-01"},{"SOURCE_ROW_NUMBER":"858841","EVENT_NO":"6139412","INSPECTION_BEGIN_DT":"09/15/2005","INSPECTION_END_DT":"09/21/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"39","SUM_TOTAL_ON_SITE_HOURS":"28","sourceDate":"2005-09-15"},{"SOURCE_ROW_NUMBER":"733223","EVENT_NO":"6136730","INSPECTION_BEGIN_DT":"03/24/2005","INSPECTION_END_DT":"03/24/2005","ACTIVITY_CODE":"CBC","ACTIVITY":"ELECTRICAL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2005-03-24"},{"SOURCE_ROW_NUMBER":"79340","EVENT_NO":"6138048","INSPECTION_BEGIN_DT":"02/16/2005","INSPECTION_END_DT":"03/02/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"47","SUM_TOTAL_ON_SITE_HOURS":"32","sourceDate":"2005-02-16"},{"SOURCE_ROW_NUMBER":"63206","EVENT_NO":"6156811","INSPECTION_BEGIN_DT":"01/31/2005","INSPECTION_END_DT":"02/01/2005","ACTIVITY_CODE":"BBF","ACTIVITY":"PART 50 AUDITS","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2005-01-31"},{"SOURCE_ROW_NUMBER":"560175","EVENT_NO":"6138490","INSPECTION_BEGIN_DT":"07/08/2004","INSPECTION_END_DT":"07/23/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"53.5","SUM_TOTAL_ON_SITE_HOURS":"30.5","sourceDate":"2004-07-08"},{"SOURCE_ROW_NUMBER":"328578","EVENT_NO":"6051123","INSPECTION_BEGIN_DT":"03/11/2004","INSPECTION_END_DT":"03/17/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"47.5","SUM_TOTAL_ON_SITE_HOURS":"29.5","sourceDate":"2004-03-11"},{"SOURCE_ROW_NUMBER":"967218","EVENT_NO":"6050903","INSPECTION_BEGIN_DT":"10/01/2003","INSPECTION_END_DT":"10/01/2003","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2003-10-01"},{"SOURCE_ROW_NUMBER":"1065296","EVENT_NO":"6182157","INSPECTION_BEGIN_DT":"09/11/2003","INSPECTION_END_DT":"09/11/2003","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"742576","EVENT_NO":"6182126","INSPECTION_BEGIN_DT":"06/12/2003","INSPECTION_END_DT":"06/12/2003","ACTIVITY_CODE":"CBC","ACTIVITY":"ELECTRICAL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2003-06-12"},{"SOURCE_ROW_NUMBER":"607710","EVENT_NO":"6050739","INSPECTION_BEGIN_DT":"04/01/2003","INSPECTION_END_DT":"04/17/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"47","SUM_TOTAL_ON_SITE_HOURS":"29.5","sourceDate":"2003-04-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":23,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":35162,"employees":58,"production":164294},"2002-Q3":{"hours":35342,"employees":48,"production":158214},"2002-Q2":{"hours":29462,"employees":48,"production":143112},"2002-Q1":{"hours":32617,"employees":48,"production":174847},"2001-Q4":{"hours":30924,"employees":50,"production":165200},"2001-Q3":{"hours":27838,"employees":43,"production":145365},"2001-Q2":{"hours":21269,"employees":29,"production":91210},"2001-Q1":{"hours":20252,"employees":20,"production":72099},"2000-Q4":{"hours":4225,"employees":10,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":19,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":4225,"employees":10,"production":0},"2001":{"hours":100283,"employees":38,"production":473874},"2002":{"hours":132583,"employees":51,"production":640467},"2003":{"hours":144361,"employees":60,"production":738450},"2004":{"hours":178208,"employees":65,"production":866186},"2005":{"hours":202379,"employees":70,"production":928558},"2006":{"hours":52096,"employees":24,"production":280278}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2002-01-15","lastDate":"2002-10-07","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":544,"pelDoseTotal":227},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"31435","EVENT_NO":"6050584","SURVEY_DATE":"10/07/2002","OCCUPATION_CD_DESC":"ROAD GRADER OPERATOR","MACHINE_CD":"28","MANUFACTURER_CD":"018","ACT_DOSE_85":"54","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"31434","EVENT_NO":"6050584","SURVEY_DATE":"10/07/2002","OCCUPATION_CD_DESC":"COAL TRUCK DRIVER","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"95","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"31433","EVENT_NO":"6050584","SURVEY_DATE":"10/07/2002","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"34","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"31432","EVENT_NO":"6050584","SURVEY_DATE":"10/07/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"113","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"31431","EVENT_NO":"6050584","SURVEY_DATE":"10/07/2002","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"47","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"31440","EVENT_NO":"6052122","SURVEY_DATE":"01/15/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"81","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"31439","EVENT_NO":"6052122","SURVEY_DATE":"01/15/2002","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"120","ACT_DOSE_85":"55","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"31438","EVENT_NO":"6052122","SURVEY_DATE":"01/15/2002","OCCUPATION_CD_DESC":"COAL TRUCK DRIVER","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"18","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"31437","EVENT_NO":"6052122","SURVEY_DATE":"01/15/2002","OCCUPATION_CD_DESC":"STRIPPING SHOVEL OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"8","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"31436","EVENT_NO":"6052122","SURVEY_DATE":"01/15/2002","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"39","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2002-01-15"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":118,"firstDate":"2001-01-22","lastDate":"2006-09-28","metrics":{"ss":32,"amountDue":17786,"contested":0,"amountPaid":17786,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":17786},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"620539","VIOLATION_NO":"7493947","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"N","PART_SECTION":"77.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620538","VIOLATION_NO":"7493946","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620537","VIOLATION_NO":"7493945","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620536","VIOLATION_NO":"7493944","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620535","VIOLATION_NO":"7493943","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620534","VIOLATION_NO":"7493942","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"723","AMOUNT_DUE":"723","AMOUNT_PAID":"723","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620533","VIOLATION_NO":"7493941","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"N","PART_SECTION":"77.1713(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620532","VIOLATION_NO":"7493940","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"N","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620531","VIOLATION_NO":"7493939","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"723","AMOUNT_DUE":"723","AMOUNT_PAID":"723","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620530","VIOLATION_NO":"7493938","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620529","VIOLATION_NO":"7493937","VIOLATION_ISSUE_DT":"09/28/2006","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"620454","VIOLATION_NO":"7486971","VIOLATION_ISSUE_DT":"02/07/2006","SIG_SUB":"N","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/07/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-02-07"}]}],"safety":{"href":"/api/v1/mines/1202294/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1202294/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Identification of circuit breakers.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.904","part":"77","subchapter":"O","subpart":"J","id":"77.904","citation":"30 CFR 77.904","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1713","heading":"Daily inspection of surface coal mine; certified person; reports of inspection.","id":"77.1713","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1713","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) At least once during each working shift, or more often if necessary for safety, each active working area and each active surface installation shall be examined by a certified person designated by the operator to conduct such examinations for hazardous conditions and any hazardous conditions noted during such examinations shall be reported to the operator and shall be corrected by the operator.\n\n(b) If any hazardous condition noted during an examination conducted in accordance with paragraph (a) of this section creates an imminent danger, the person conducting such examination shall notify the operator and the operator shall withdraw all persons from the area affected, except those persons referred to in section 104(d) of the Act, until the danger is abated.\n\n(c) After each examination conducted in accordance with the provisions of paragraph (a) of this section, each certified person who conducted all or any part of the examination required shall enter with ink or indelible pencil in a book approved by the Secretary the date and a report of the condition of the mine or any area of the mine which he has inspected together with a report of the nature and location of any hazardous condition found to be present at the mine. The book in which such entries are made shall be kept in an area at the mine designated by the operator to minimize the danger of destruction by fire or other hazard.\n\n(d) All examination reports recorded in accordance with the provisions of paragraph (c) of this section shall include a report of the action taken to abate hazardous conditions and shall be signed or countersigned each day by at least one of the following persons:\n\n(1) The surface mine foreman;\n\n(2) The assistant superintendent of the mine;\n\n(3) The superintendent of the mine;\n\n(4) The person designated by the operator as responsible for health and safety at the mine; or,\n\n(5) An equivalent mine official.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995; 63 FR 58613, Oct. 30, 1998]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1202294","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}