{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1202249","name":"Prosperity Mine","status":"Abandoned","status_date":"2026-10-06","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IN","county":"Pike","nearest_town":"Petersburg, IN 47567","operator_id":"0051576","operator_name":"Sunrise Coal, LLC","controller_id":"0141083","controller_name":"Hallador Energy Company","district":"C08","office":"Vincennes IN Field Office","employees":0,"latitude":38.489167,"longitude":-87.396111},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":25903},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1202249","name":"Prosperity Mine"},"operator":{"type":"operator","id":"0051576","name":"Sunrise Coal, LLC"},"controller":{"type":"controller","id":"0141083","name":"Hallador Energy Company"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24100","name":"Five Star Mining Inc"},"object":{"type":"mine","id":"1202249","name":"Prosperity Mine"},"validFrom":"1999-03-01","validTo":"2014-08-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|P24100|1999-03-01|2014-08-29"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14311","name":"Donald  Blankenberger"},"object":{"type":"mine","id":"1202249","name":"Prosperity Mine"},"validFrom":"1999-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|C14311|1999-03-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14311","name":"Donald  Blankenberger"},"object":{"type":"operator","id":"P24100","name":"Five Star Mining Inc"},"validFrom":"1999-03-01","validTo":"2014-08-29","current":false,"derived":true,"evidenceMineId":"1202249","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|P24100|1999-03-01|C14311|1999-03-01|92469"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12185","name":"Ronald E  Laswell et al"},"object":{"type":"mine","id":"1202249","name":"Prosperity Mine"},"validFrom":"2003-06-04","validTo":"2012-04-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|C12185|2003-06-04|2012-04-25"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0104017","name":"Brent K  Bilsland et al"},"object":{"type":"mine","id":"1202249","name":"Prosperity Mine"},"validFrom":"2012-04-26","validTo":"2018-05-10","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|0104017|2012-04-26|2018-05-10"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051576","name":"Sunrise Coal, LLC"},"object":{"type":"mine","id":"1202249","name":"Prosperity Mine"},"validFrom":"2014-08-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|0051576|2014-08-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0104017","name":"Brent K  Bilsland et al"},"object":{"type":"operator","id":"0051576","name":"Sunrise Coal, LLC"},"validFrom":"2014-08-30","validTo":"2018-05-10","current":false,"derived":true,"evidenceMineId":"1202249","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|0051576|2014-08-30|0104017|2012-04-26|17958"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12185","name":"Ronald E  Laswell et al"},"object":{"type":"operator","id":"0051576","name":"Sunrise Coal, LLC"},"validFrom":"2014-08-30","validTo":"2012-04-25","current":false,"derived":true,"evidenceMineId":"1202249","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|0051576|2014-08-30|C12185|2003-06-04|86319"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0141083","name":"Hallador Energy Company"},"object":{"type":"mine","id":"1202249","name":"Prosperity Mine"},"validFrom":"2018-05-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|0141083|2018-05-11|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0141083","name":"Hallador Energy Company"},"object":{"type":"operator","id":"0051576","name":"Sunrise Coal, LLC"},"validFrom":"2018-05-11","validTo":null,"current":true,"derived":true,"evidenceMineId":"1202249","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1202249|0051576|2014-08-30|0141083|2018-05-11|28535"}}],"coverage":{"historyRecords":4,"edgeCount":10,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":604,"firstDate":"2000-08-21","lastDate":"2023-08-03","metrics":{"daysLost":8766,"injuries":253,"fatalities":2,"recentRows":1,"restrictedDays":1363,"contractorRecords":25},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"177452","DOCUMENT_NO":"220232200006","ACCIDENT_DT":"08/03/2023","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured was operating a 777 end dump. EE was being loaded with a 992 loader. As the 992 loader operator dumped a load into the bed of the end dump the operator of the end dump was jarred. EE went to the Dr. on 8/4/2023 and was placed on restricted duty for a back strain.","sourceDate":"2023-08-03"},{"SOURCE_ROW_NUMBER":"99813","DOCUMENT_NO":"220143110013","ACCIDENT_DT":"11/05/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"17","NARRATIVE":"Injured was using a cutting torch to cut loose a jack pipe.  The jack pipe buckled and struck injured causing him to fall backwards and the torch he was holding fell on his thigh area causing  2nd degree burns.","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"216158","DOCUMENT_NO":"220142370030","ACCIDENT_DT":"08/20/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"Employee was traveling in a mantrip when he hit a block causing him to bounce around in mantrip.  Employee sustained a fracture to his back and will remain off work for an uncertain period of time.","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"65437","DOCUMENT_NO":"220142390034","ACCIDENT_DT":"08/18/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unintentional roof fall occurred on 2 South 2, Crosscut 16 between Entries 5 and 6. The roof fall measured approximately 40' in length, 18' in width, and 8' in thickness. A 103(k) Order (8444691) was issued August 20, 2014, by MSHA Inspector.","sourceDate":"2014-08-18"},{"SOURCE_ROW_NUMBER":"250601","DOCUMENT_NO":"220141960042","ACCIDENT_DT":"07/07/2014","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was installing split steel and didn't know his glove was caught. Employee went to Good Samaritan Hospital sustaining a fracture to his finger which requires surgery and will be off work for an uncertain period of time.","sourceDate":"2014-07-07"},{"SOURCE_ROW_NUMBER":"173106","DOCUMENT_NO":"220141770024","ACCIDENT_DT":"06/24/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unintentional roof fall occurred on 2 North 1 Left Return, Crosscut 52 Entry 2. The roof fall measured approximately 30' in length, 17' in width, and 6' in thickness. A 103(k) Order (9033537) was issued June 24, 2014, by MSHA Inspector.","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"242026","DOCUMENT_NO":"220141710055","ACCIDENT_DT":"06/15/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unintentional roof fall occurred on Unit 4 (MMU 008), Crosscut 13 Entry 6-7. The roof fall measured approximately 50' in length, 18' in width, and 8-10' in thickness. A 103(k) Order (9033214) was issued June 15, 2014, by MSHA Inspector.","sourceDate":"2014-06-15"},{"SOURCE_ROW_NUMBER":"61217","DOCUMENT_NO":"220141550021","ACCIDENT_DT":"06/02/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was using a utility knife and slipped cutting into his leg.  Employee immediately went to Good Samaritan Hospital receiving sutures.","sourceDate":"2014-06-02"},{"SOURCE_ROW_NUMBER":"229068","DOCUMENT_NO":"220141480013","ACCIDENT_DT":"05/20/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unintentional roof fall occurred on the 3 North 3, Crosscut 26 Entry 5 Beltline. The roof fall measured approximately 48' in length, 18' in width, and 6' in thickness. A 103(k) Order (8444663) was issued May 20, 2014, by MSHA Inspector.","sourceDate":"2014-05-20"},{"SOURCE_ROW_NUMBER":"271996","DOCUMENT_NO":"220141470018","ACCIDENT_DT":"05/17/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was hammering to remove a bit from the No. 1 CM when a sliver came from the bit entering employees thumb.  Employee went to hospital receiving sutures to his thumb.","sourceDate":"2014-05-17"},{"SOURCE_ROW_NUMBER":"267693","DOCUMENT_NO":"220141320048","ACCIDENT_DT":"05/06/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"25","NARRATIVE":"Employee was working in water and grout from the drill hole.  Employee sustained 3rd degree burns and remains off work for an uncertain period of time.","sourceDate":"2014-05-06"},{"SOURCE_ROW_NUMBER":"78506","DOCUMENT_NO":"220141040068","ACCIDENT_DT":"04/15/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was carrying a roller when he hit his finger against a timber requiring him to get sutures.","sourceDate":"2014-04-15"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-10-06","lastDate":"2026-10-06","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":6234,"firstDate":"2000-03-09","lastDate":"2023-07-26","metrics":{"ss":1438,"delinquent":6103,"recentRows":5,"paidPenalty":6384364.5,"proposedPenalty":9096788,"currentAssessment":6385472.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2836277","VIOLATION_NO":"9193986","ISSUE_DT":"07/26/2023","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-07-26"},{"SOURCE_ROW_NUMBER":"2003768","VIOLATION_NO":"9540116","ISSUE_DT":"08/10/2022","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-08-10"},{"SOURCE_ROW_NUMBER":"2003767","VIOLATION_NO":"9540115","ISSUE_DT":"08/10/2022","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-08-10"},{"SOURCE_ROW_NUMBER":"2003766","VIOLATION_NO":"9193766","ISSUE_DT":"08/10/2022","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-08-10"},{"SOURCE_ROW_NUMBER":"2003765","VIOLATION_NO":"9193765","ISSUE_DT":"08/10/2022","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-08-10"},{"SOURCE_ROW_NUMBER":"2006439","VIOLATION_NO":"9034182","ISSUE_DT":"12/17/2014","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-12-17"},{"SOURCE_ROW_NUMBER":"2006438","VIOLATION_NO":"9034181","ISSUE_DT":"12/17/2014","CFR_STANDARD_CD":"77.410(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-12-17"},{"SOURCE_ROW_NUMBER":"2006479","VIOLATION_NO":"9034165","ISSUE_DT":"11/06/2014","CFR_STANDARD_CD":"75.364(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-06"},{"SOURCE_ROW_NUMBER":"2006478","VIOLATION_NO":"9034157","ISSUE_DT":"10/17/2014","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-17"},{"SOURCE_ROW_NUMBER":"2006477","VIOLATION_NO":"9034156","ISSUE_DT":"10/17/2014","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-17"},{"SOURCE_ROW_NUMBER":"2006476","VIOLATION_NO":"9034149","ISSUE_DT":"10/06/2014","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"13268.00","CURRENT_ASSESSMENT_AMT":"13268.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-06"},{"SOURCE_ROW_NUMBER":"1211779","VIOLATION_NO":"8444662","ISSUE_DT":"09/08/2014","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1203.00","CURRENT_ASSESSMENT_AMT":"1203.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-08"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1316,"firstDate":"2008-10-27","lastDate":"2015-11-30","metrics":{"appeals":0,"decisions":1316,"recentRows":0,"decisionPenalty":3636230.5,"originalPenalty":6421484},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"367252","VIOLATION_NO":"9033137","DOCKET_NO":"LAKE 2015-0165","DECISION_DT":"11/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"25800.00","DECISION_PENALTY_AMT":"12900.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2015-11-30"},{"SOURCE_ROW_NUMBER":"358643","VIOLATION_NO":"8450040","DOCKET_NO":"LAKE 2014-0412","DECISION_DT":"11/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8600.00","DECISION_PENALTY_AMT":"4300.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2015-11-30"},{"SOURCE_ROW_NUMBER":"334245","VIOLATION_NO":"8446911","DOCKET_NO":"LAKE 2012-905","DECISION_DT":"11/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"35500.00","DECISION_PENALTY_AMT":"17750.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2015-11-30"},{"SOURCE_ROW_NUMBER":"333412","VIOLATION_NO":"8446910","DOCKET_NO":"LAKE 2012-905","DECISION_DT":"11/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"38000.00","DECISION_PENALTY_AMT":"19000.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2015-11-30"},{"SOURCE_ROW_NUMBER":"112463","VIOLATION_NO":"8450752","DOCKET_NO":"LAKE 2015-0166","DECISION_DT":"11/30/2015","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"181.00","DECISION_PENALTY_AMT":"181.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2015-11-30"},{"SOURCE_ROW_NUMBER":"106758","VIOLATION_NO":"8450038","DOCKET_NO":"LAKE 2014-0412","DECISION_DT":"11/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"12900.00","DECISION_PENALTY_AMT":"6450.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2015-11-30"},{"SOURCE_ROW_NUMBER":"106471","VIOLATION_NO":"8450039","DOCKET_NO":"LAKE 2014-0412","DECISION_DT":"11/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"12900.00","DECISION_PENALTY_AMT":"6450.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2015-11-30"},{"SOURCE_ROW_NUMBER":"91862","VIOLATION_NO":"8446901","DOCKET_NO":"LAKE 2012-905","DECISION_DT":"11/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"42600.00","DECISION_PENALTY_AMT":"21300.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2015-11-30"},{"SOURCE_ROW_NUMBER":"91589","VIOLATION_NO":"8433800","DOCKET_NO":"LAKE 2012-905","DECISION_DT":"11/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"26250.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2015-11-30"},{"SOURCE_ROW_NUMBER":"286658","VIOLATION_NO":"8426071","DOCKET_NO":"LAKE 2011-17","DECISION_DT":"11/01/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"9634.00","DECISION_PENALTY_AMT":"9634.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2015-11-01"},{"SOURCE_ROW_NUMBER":"285198","VIOLATION_NO":"8426069","DOCKET_NO":"LAKE 2011-17","DECISION_DT":"11/01/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"11306.00","DECISION_PENALTY_AMT":"11306.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2015-11-01"},{"SOURCE_ROW_NUMBER":"63292","VIOLATION_NO":"8426628","DOCKET_NO":"LAKE 2011-17","DECISION_DT":"11/01/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"263.00","DECISION_PENALTY_AMT":"263.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2015-11-01"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":4585,"firstDate":"2001-01-25","lastDate":"2026-08-13","metrics":{"recentRows":65,"cpdmSamples":0,"voidSamples":404,"validSamples":4181,"maxConcentration":44.601,"concentrationTotal":3705.071},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"870203","CASS_NUM":"51673737","SMP_TAKEN_DT":"8/13/2026","CONC":".019","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"1360174","CASS_NUM":"58558853","SMP_TAKEN_DT":"5/27/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"909239","CASS_NUM":"58559147","SMP_TAKEN_DT":"5/27/2026","CONC":".021","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"1576209","CASS_NUM":"51667675","SMP_TAKEN_DT":"4/23/2026","CONC":".036","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-04-23"},{"SOURCE_ROW_NUMBER":"830048","CASS_NUM":"51666151","SMP_TAKEN_DT":"11/25/2025","CONC":".01","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-11-25"},{"SOURCE_ROW_NUMBER":"1217534","CASS_NUM":"58566948","SMP_TAKEN_DT":"8/28/2025","CONC":".03","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-08-28"},{"SOURCE_ROW_NUMBER":"1044736","CASS_NUM":"58566789","SMP_TAKEN_DT":"8/28/2025","CONC":".084","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER/BLACKSMITH","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-08-28"},{"SOURCE_ROW_NUMBER":"783724","CASS_NUM":"51649073","SMP_TAKEN_DT":"7/29/2025","CONC":".019","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-07-29"},{"SOURCE_ROW_NUMBER":"180678","CASS_NUM":"51639536","SMP_TAKEN_DT":"4/9/2025","CONC":".016","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-04-09"},{"SOURCE_ROW_NUMBER":"596507","CASS_NUM":"51631163","SMP_TAKEN_DT":"1/29/2025","CONC":".019","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-01-29"},{"SOURCE_ROW_NUMBER":"1286872","CASS_NUM":"58489281","SMP_TAKEN_DT":"12/5/2024","CONC":".029","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2024-12-05"},{"SOURCE_ROW_NUMBER":"950304","CASS_NUM":"58489378","SMP_TAKEN_DT":"12/5/2024","CONC":".079","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2024-12-05"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":577,"firstDate":"2002-06-03","lastDate":"2019-09-27","metrics":{"linkedIssuances":577},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1316,"firstDate":"2007-02-07","lastDate":"2014-08-20","metrics":{"decisions":1316,"ssChanged":234,"recentRows":0,"decisionPenalty":3636230.5,"proposedPenalty":6421484},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"317433","CITATION_NO":"8444687","CITATION_ISSUE_DT":"08/20/2014","DOCKET_NO":"LAKE 2015-0164","DECISION_DT":"06/24/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"9634.00","DECISION_PENALTY_AMT":"6650.00","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"317081","CITATION_NO":"8444688","CITATION_ISSUE_DT":"08/20/2014","DOCKET_NO":"LAKE 2015-0164","DECISION_DT":"06/24/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"9634.00","DECISION_PENALTY_AMT":"6650.00","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"259190","CITATION_NO":"8444685","CITATION_ISSUE_DT":"08/20/2014","DOCKET_NO":"LAKE 2015-0164","DECISION_DT":"06/24/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"9634.00","DECISION_PENALTY_AMT":"6650.00","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"202619","CITATION_NO":"8444686","CITATION_ISSUE_DT":"08/20/2014","DOCKET_NO":"LAKE 2015-0164","DECISION_DT":"06/24/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"9634.00","DECISION_PENALTY_AMT":"6650.00","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"204170","CITATION_NO":"8444675","CITATION_ISSUE_DT":"07/11/2014","DOCKET_NO":"LAKE 2014-0687","DECISION_DT":"03/26/2015","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"1304.00","sourceDate":"2014-07-11"},{"SOURCE_ROW_NUMBER":"373947","CITATION_NO":"9034126","CITATION_ISSUE_DT":"07/10/2014","DOCKET_NO":"LAKE 2014-0687","DECISION_DT":"03/26/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"3996.00","DECISION_PENALTY_AMT":"3996.00","sourceDate":"2014-07-10"},{"SOURCE_ROW_NUMBER":"34552","CITATION_NO":"9034125","CITATION_ISSUE_DT":"07/10/2014","DOCKET_NO":"LAKE 2014-0687","DECISION_DT":"03/26/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"3996.00","DECISION_PENALTY_AMT":"3996.00","sourceDate":"2014-07-10"},{"SOURCE_ROW_NUMBER":"93788","CITATION_NO":"9034123","CITATION_ISSUE_DT":"07/09/2014","DOCKET_NO":"LAKE 2014-0687","DECISION_DT":"03/26/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"13268.00","DECISION_PENALTY_AMT":"5000.00","sourceDate":"2014-07-09"},{"SOURCE_ROW_NUMBER":"34822","CITATION_NO":"9034120","CITATION_ISSUE_DT":"07/08/2014","DOCKET_NO":"LAKE 2014-0687","DECISION_DT":"03/26/2015","CFR_STANDARD_CODE":"75.363(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1530.00","DECISION_PENALTY_AMT":"1530.00","sourceDate":"2014-07-08"},{"SOURCE_ROW_NUMBER":"91307","CITATION_NO":"9034116","CITATION_ISSUE_DT":"07/02/2014","DOCKET_NO":"LAKE 2014-0687","DECISION_DT":"03/26/2015","CFR_STANDARD_CODE":"75.1714-2(f)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"2282.00","sourceDate":"2014-07-02"},{"SOURCE_ROW_NUMBER":"264135","CITATION_NO":"8450770","CITATION_ISSUE_DT":"06/17/2014","DOCKET_NO":"LAKE 2014-0687","DECISION_DT":"03/26/2015","CFR_STANDARD_CODE":"77.1607(i)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"11306.00","DECISION_PENALTY_AMT":"11306.00","sourceDate":"2014-06-17"},{"SOURCE_ROW_NUMBER":"202577","CITATION_NO":"8450769","CITATION_ISSUE_DT":"06/17/2014","DOCKET_NO":"LAKE 2014-0687","DECISION_DT":"03/26/2015","CFR_STANDARD_CODE":"77.1607(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"11306.00","DECISION_PENALTY_AMT":"11306.00","sourceDate":"2014-06-17"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":2255,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":22,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":499,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":22,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"1999-03-01","lastDate":"2014-08-30","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":895,"firstDate":"2000-01-07","lastDate":"2026-09-22","metrics":{"inspectors":1549,"recentRows":24,"onSiteHours":35750.25,"inspectionHours":49813.25,"inspectionSamples":1946},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"948112","EVENT_NO":"F01E464","INSPECTION_BEGIN_DT":"09/22/2026","INSPECTION_END_DT":"09/22/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.25","SUM_TOTAL_ON_SITE_HOURS":"2.75","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"943633","EVENT_NO":"F030893","INSPECTION_BEGIN_DT":"05/27/2026","INSPECTION_END_DT":"05/27/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"329471","EVENT_NO":"F016B85","INSPECTION_BEGIN_DT":"01/22/2026","INSPECTION_END_DT":"01/22/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.25","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2026-01-22"},{"SOURCE_ROW_NUMBER":"935345","EVENT_NO":"7037994","INSPECTION_BEGIN_DT":"09/04/2025","INSPECTION_END_DT":"09/04/2025","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2025-09-04"},{"SOURCE_ROW_NUMBER":"935551","EVENT_NO":"F0086F6","INSPECTION_BEGIN_DT":"08/28/2025","INSPECTION_END_DT":"08/28/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"10.75","sourceDate":"2025-08-28"},{"SOURCE_ROW_NUMBER":"740072","EVENT_NO":"F0161C9","INSPECTION_BEGIN_DT":"07/10/2025","INSPECTION_END_DT":"07/10/2025","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2025-07-10"},{"SOURCE_ROW_NUMBER":"24352","EVENT_NO":"6456793","INSPECTION_BEGIN_DT":"12/04/2024","INSPECTION_END_DT":"03/12/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"37","SUM_TOTAL_ON_SITE_HOURS":"26","sourceDate":"2024-12-04"},{"SOURCE_ROW_NUMBER":"136674","EVENT_NO":"7037766","INSPECTION_BEGIN_DT":"05/07/2024","INSPECTION_END_DT":"09/23/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"35","SUM_TOTAL_ON_SITE_HOURS":"22.75","sourceDate":"2024-05-07"},{"SOURCE_ROW_NUMBER":"583740","EVENT_NO":"7011067","INSPECTION_BEGIN_DT":"12/13/2023","INSPECTION_END_DT":"02/28/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"60.75","SUM_TOTAL_ON_SITE_HOURS":"43.75","sourceDate":"2023-12-13"},{"SOURCE_ROW_NUMBER":"870720","EVENT_NO":"7010945","INSPECTION_BEGIN_DT":"08/28/2023","INSPECTION_END_DT":"08/28/2023","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2023-08-28"},{"SOURCE_ROW_NUMBER":"22987","EVENT_NO":"7018633","INSPECTION_BEGIN_DT":"08/02/2023","INSPECTION_END_DT":"08/02/2023","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2023-08-02"},{"SOURCE_ROW_NUMBER":"514672","EVENT_NO":"7018996","INSPECTION_BEGIN_DT":"07/26/2023","INSPECTION_END_DT":"08/02/2023","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"7.75","sourceDate":"2023-07-26"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":367,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":3417,"employees":7,"production":0},"2026-Q1":{"hours":3262,"employees":7,"production":0},"2025-Q4":{"hours":3428,"employees":7,"production":0},"2025-Q3":{"hours":3414,"employees":7,"production":0},"2025-Q2":{"hours":3394,"employees":7,"production":0},"2025-Q1":{"hours":3240,"employees":7,"production":0},"2024-Q4":{"hours":3127,"employees":7,"production":0},"2024-Q3":{"hours":3331,"employees":7,"production":0},"2024-Q2":{"hours":4233,"employees":7,"production":0},"2024-Q1":{"hours":11188,"employees":14,"production":22519},"2023-Q4":{"hours":16582,"employees":32,"production":15691},"2023-Q3":{"hours":19730,"employees":34,"production":51514}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":70,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014":{"hours":747592,"employees":310,"production":1321377},"2018":{"hours":2932,"employees":3,"production":0},"2019":{"hours":6279,"employees":2,"production":0},"2020":{"hours":4302,"employees":2,"production":0},"2021":{"hours":9868,"employees":6,"production":0},"2022":{"hours":37958,"employees":38,"production":36995},"2023":{"hours":72695,"employees":33,"production":138069},"2024":{"hours":21879,"employees":21,"production":22519},"2025":{"hours":13476,"employees":7,"production":0},"2026":{"hours":6679,"employees":7,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":420,"firstDate":"2001-01-23","lastDate":"2026-05-27","metrics":{"recentRows":16,"doseOver100":96,"actDoseTotal":42070,"pelDoseTotal":23102},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"31265","EVENT_NO":"F030893","SURVEY_DATE":"05/27/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"54","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"31264","EVENT_NO":"F030893","SURVEY_DATE":"05/27/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"125","PEL_DOSE_90":"104","SURVEY_TYPE":"I","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"31263","EVENT_NO":"7011067","SURVEY_DATE":"12/13/2023","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"91","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2023-12-13"},{"SOURCE_ROW_NUMBER":"31262","EVENT_NO":"7011067","SURVEY_DATE":"12/13/2023","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"58","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2023-12-13"},{"SOURCE_ROW_NUMBER":"31261","EVENT_NO":"7011067","SURVEY_DATE":"12/13/2023","OCCUPATION_CD_DESC":"COAL TRUCK DRIVER","MACHINE_CD":"39","ACT_DOSE_85":"25","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2023-12-13"},{"SOURCE_ROW_NUMBER":"31260","EVENT_NO":"7011067","SURVEY_DATE":"12/13/2023","OCCUPATION_CD_DESC":"COAL TRUCK DRIVER","MACHINE_CD":"39","ACT_DOSE_85":"55","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2023-12-13"},{"SOURCE_ROW_NUMBER":"31259","EVENT_NO":"7011067","SURVEY_DATE":"12/13/2023","OCCUPATION_CD_DESC":"COAL TRUCK DRIVER","MACHINE_CD":"39","ACT_DOSE_85":"56","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2023-12-13"},{"SOURCE_ROW_NUMBER":"31258","EVENT_NO":"7010808","SURVEY_DATE":"02/28/2023","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"40","ACT_DOSE_85":"22","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2023-02-28"},{"SOURCE_ROW_NUMBER":"31257","EVENT_NO":"7010808","SURVEY_DATE":"02/28/2023","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"59","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2023-02-28"},{"SOURCE_ROW_NUMBER":"31256","EVENT_NO":"7010808","SURVEY_DATE":"02/28/2023","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"64","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2023-02-28"},{"SOURCE_ROW_NUMBER":"31255","EVENT_NO":"7010808","SURVEY_DATE":"02/28/2023","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"45","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2023-02-28"},{"SOURCE_ROW_NUMBER":"31254","EVENT_NO":"7010808","SURVEY_DATE":"02/28/2023","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","ACT_DOSE_85":"11","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2023-02-28"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":375,"firstDate":"2001-01-22","lastDate":"2022-09-14","metrics":{"recentRows":3,"voidSamples":24,"maxQuartzPct":21.1,"validSamples":351,"quartzPctTotal":1381.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"163534","CASSETTE_NO":"58414526","SAMPLE_DT":"09/14/2022","QUARTZ_PCT":"05.5","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-09-14"},{"SOURCE_ROW_NUMBER":"24494","CASSETTE_NO":"58414700","SAMPLE_DT":"09/14/2022","QUARTZ_PCT":"21.1","QUARTZ_MICROGRAMS":"47","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-09-14"},{"SOURCE_ROW_NUMBER":"67861","CASSETTE_NO":"58414468","SAMPLE_DT":"08/17/2022","QUARTZ_PCT":"04.9","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-08-17"},{"SOURCE_ROW_NUMBER":"67738","CASSETTE_NO":"58158800","SAMPLE_DT":"08/26/2014","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-08-26"},{"SOURCE_ROW_NUMBER":"143381","CASSETTE_NO":"58140290","SAMPLE_DT":"04/28/2014","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"141566","CASSETTE_NO":"58140608","SAMPLE_DT":"04/28/2014","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"138596","CASSETTE_NO":"58140681","SAMPLE_DT":"04/25/2014","QUARTZ_PCT":"02.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-04-25"},{"SOURCE_ROW_NUMBER":"160970","CASSETTE_NO":"58140457","SAMPLE_DT":"03/31/2014","QUARTZ_PCT":"02.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-03-31"},{"SOURCE_ROW_NUMBER":"38789","CASSETTE_NO":"58144058","SAMPLE_DT":"02/07/2014","QUARTZ_PCT":"02.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-02-07"},{"SOURCE_ROW_NUMBER":"126149","CASSETTE_NO":"58143557","SAMPLE_DT":"01/22/2014","QUARTZ_PCT":"02.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-01-22"},{"SOURCE_ROW_NUMBER":"68283","CASSETTE_NO":"58143720","SAMPLE_DT":"01/22/2014","QUARTZ_PCT":"01.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-01-22"},{"SOURCE_ROW_NUMBER":"70457","CASSETTE_NO":"58143943","SAMPLE_DT":"01/13/2014","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-01-13"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":6384,"firstDate":"2000-03-09","lastDate":"2023-07-26","metrics":{"ss":1444,"amountDue":6386975.5,"contested":542,"amountPaid":6385867.5,"recentRows":5,"section104d":80,"unterminated":13,"proposedPenalty":9098291},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"616080","VIOLATION_NO":"9193986","VIOLATION_ISSUE_DT":"07/26/2023","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/26/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-07-26"},{"SOURCE_ROW_NUMBER":"616151","VIOLATION_NO":"9540116","VIOLATION_ISSUE_DT":"08/10/2022","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/17/2022","PROPOSED_PENALTY":"133","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2022-08-10"},{"SOURCE_ROW_NUMBER":"616150","VIOLATION_NO":"9540115","VIOLATION_ISSUE_DT":"08/10/2022","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/10/2022","PROPOSED_PENALTY":"133","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2022-08-10"},{"SOURCE_ROW_NUMBER":"616149","VIOLATION_NO":"9193766","VIOLATION_ISSUE_DT":"08/10/2022","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/11/2022","PROPOSED_PENALTY":"133","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2022-08-10"},{"SOURCE_ROW_NUMBER":"616148","VIOLATION_NO":"9193765","VIOLATION_ISSUE_DT":"08/10/2022","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/10/2022","PROPOSED_PENALTY":"133","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2022-08-10"},{"SOURCE_ROW_NUMBER":"616490","VIOLATION_NO":"9034182","VIOLATION_ISSUE_DT":"12/17/2014","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/17/2014","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2014-12-17"},{"SOURCE_ROW_NUMBER":"616489","VIOLATION_NO":"9034181","VIOLATION_ISSUE_DT":"12/17/2014","SIG_SUB":"N","PART_SECTION":"77.410(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/17/2014","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2014-12-17"},{"SOURCE_ROW_NUMBER":"617804","VIOLATION_NO":"9034165","VIOLATION_ISSUE_DT":"11/06/2014","SIG_SUB":"N","PART_SECTION":"75.364(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/12/2014","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2014-11-06"},{"SOURCE_ROW_NUMBER":"617802","VIOLATION_NO":"9034271","VIOLATION_ISSUE_DT":"11/05/2014","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"11/12/2014","CONTESTED_IND":"N","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"617642","VIOLATION_NO":"9034157","VIOLATION_ISSUE_DT":"10/17/2014","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"25","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/17/2014","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1412","AMOUNT_PAID":"1412","CONTESTED_IND":"N","sourceDate":"2014-10-17"},{"SOURCE_ROW_NUMBER":"617641","VIOLATION_NO":"9034156","VIOLATION_ISSUE_DT":"10/17/2014","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"25","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/17/2014","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1412","AMOUNT_PAID":"1412","CONTESTED_IND":"N","sourceDate":"2014-10-17"},{"SOURCE_ROW_NUMBER":"617441","VIOLATION_NO":"9034149","VIOLATION_ISSUE_DT":"10/06/2014","SIG_SUB":"Y","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/06/2014","PROPOSED_PENALTY":"13268","AMOUNT_DUE":"13268","AMOUNT_PAID":"13268","CONTESTED_IND":"N","sourceDate":"2014-10-06"}]}],"safety":{"href":"/api/v1/mines/1202249/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1202249/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":9,"companyType":"Operating Subsidiary","components":[{"averageEmployees":9,"laborHours":21879,"mineType":"Surface","productionTons":22519}],"county":"Pike","laborHours":21879,"mineName":"Prosperity Mine","mineType":"Surface","mshaId":"1202249","operatingAddress":"12661 N. Agricare Rd., Oaktown, IN 47561","operatingCompany":"Sunrise Coal, Llc","operationType":"Mine and Preparation Plant","productionTons":22519,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Indiana","status":"Active, men working, not producing","supplyRegion":"Illinois Basin","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1202249","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}