{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1103225","name":"Watco Transloading/ Cahokia Terminals","status":"Active","status_date":"2010-04-14","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IL","county":"St Clair","nearest_town":"Cahokia","operator_id":"0149654","operator_name":"Watco Trans Loading LLC","controller_id":"0131583","controller_name":"Watco Holdings Inc","district":"C08","office":"Litchfield IL Field Office","employees":25,"latitude":38.603889,"longitude":-90.184722},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1473},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1103225","name":"Watco Transloading/ Cahokia Terminals"},"operator":{"type":"operator","id":"0149654","name":"Watco Trans Loading LLC"},"controller":{"type":"controller","id":"0131583","name":"Watco Holdings Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15894","name":"Kinder Morgan Inc et al"},"object":{"type":"mine","id":"1103225","name":"Watco Transloading/ Cahokia Terminals"},"validFrom":"2000-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103225|C15894|2000-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24333","name":"Kinder Morgan Operating LP, C"},"object":{"type":"mine","id":"1103225","name":"Watco Transloading/ Cahokia Terminals"},"validFrom":"2010-04-06","validTo":"2017-02-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103225|P24333|2010-04-06|2017-02-21"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15894","name":"Kinder Morgan Inc et al"},"object":{"type":"operator","id":"P24333","name":"Kinder Morgan Operating LP, C"},"validFrom":"2010-04-06","validTo":"2017-02-21","current":false,"derived":true,"evidenceMineId":"1103225","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103225|P24333|2010-04-06|C15894|2000-01-01|97513"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15894","name":"Kinder Morgan Energy Partners et al"},"object":{"type":"operator","id":"P24333","name":"Kinder Morgan Operating LP, C"},"validFrom":"2010-04-06","validTo":"2017-02-21","current":false,"derived":true,"evidenceMineId":"1103225","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103225|P24333|2010-04-06|C15894|2000-01-01|97514"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0149654","name":"Watco Trans Loading LLC"},"object":{"type":"mine","id":"1103225","name":"Watco Transloading/ Cahokia Terminals"},"validFrom":"2017-02-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103225|0149654|2017-02-22|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0131583","name":"Watco Holdings Inc"},"object":{"type":"mine","id":"1103225","name":"Watco Transloading/ Cahokia Terminals"},"validFrom":"2017-02-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103225|0131583|2017-02-22|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0131583","name":"Watco Holdings Inc"},"object":{"type":"operator","id":"0149654","name":"Watco Trans Loading LLC"},"validFrom":"2017-02-22","validTo":null,"current":true,"derived":true,"evidenceMineId":"1103225","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103225|0149654|2017-02-22|0131583|2017-02-22|26397"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":14,"firstDate":"2010-10-31","lastDate":"2026-07-05","metrics":{"daysLost":343,"injuries":14,"fatalities":0,"recentRows":1,"restrictedDays":255,"contractorRecords":3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"18137","DOCUMENT_NO":"220261960010","ACCIDENT_DT":"07/05/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Team Member was stung on the right hand while retrieving a ladder from storage.","sourceDate":"2026-07-05"},{"SOURCE_ROW_NUMBER":"160123","DOCUMENT_NO":"220190720002","ACCIDENT_DT":"03/08/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"327","NARRATIVE":"Team member was using a sledge hammer to knock coal free from a hopper when EE tore EE's bicep muscle in EE's right arm.","sourceDate":"2019-03-08"},{"SOURCE_ROW_NUMBER":"95411","DOCUMENT_NO":"220150050023","ACCIDENT_DT":"12/29/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Struck by plate steel","sourceDate":"2014-12-29"},{"SOURCE_ROW_NUMBER":"198695","DOCUMENT_NO":"220150050025","ACCIDENT_DT":"12/22/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Smashed finger between 2 pieces of channel steel","sourceDate":"2014-12-22"},{"SOURCE_ROW_NUMBER":"112592","DOCUMENT_NO":"220140270010","ACCIDENT_DT":"01/24/2014","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Deckhand was loosening barge lines.  2\" rope line fed quickly through his hands and the end of the rope whipped and struck his right wrist causing a fracture to his wrist.","sourceDate":"2014-01-24"},{"SOURCE_ROW_NUMBER":"26846","DOCUMENT_NO":"220132830339","ACCIDENT_DT":"10/08/2013","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"An employee stepped down off the stair onto a rubber mat which was covering a drain resulting in the employee rolling his right ankle.  The employee did not fall or trip.   He left work and called in the next day reporting swelling to his ankle.  Diagnosed with mild sprain to his right ankle and given restricted duty.","sourceDate":"2013-10-08"},{"SOURCE_ROW_NUMBER":"129721","DOCUMENT_NO":"220111780069","ACCIDENT_DT":"06/10/2011","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee diagnosed on 6/10/11 with carpal tunnel syndrome be independent medical examiner(IME). The IME determined it was likely caused by work.","sourceDate":"2011-06-10"},{"SOURCE_ROW_NUMBER":"61120","DOCUMENT_NO":"220111650029","ACCIDENT_DT":"06/03/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating a car hoe to unload coal train cars. At lunch break employee walked to the locker room, laid down on a bench and felt a pop in his lower back in the middle. Employee given prescription pain medicine.","sourceDate":"2011-06-03"},{"SOURCE_ROW_NUMBER":"271899","DOCUMENT_NO":"220111040029","ACCIDENT_DT":"04/06/2011","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"14","NARRATIVE":"Employee was swinging a sledge hammer to free bridged coal on conveyor transfer chute. Felt pain in his abdomen. Diagnosed with hernia by doctor.","sourceDate":"2011-04-06"},{"SOURCE_ROW_NUMBER":"39670","DOCUMENT_NO":"220110940028","ACCIDENT_DT":"03/23/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"EE had a small piece of metal in his left eye. Metal piece was lodged there without great force as it was at the surface. Piece removed at the clinic and prescriptions given. EE lost 1 day of work. EE was wearing safety glasses at the time of the incident. Winds on the day of the incident were at or near 40mph most of the day. EE was assisting during a grinding operation.","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"99717","DOCUMENT_NO":"220110630033","ACCIDENT_DT":"02/26/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Temp EE put hand in the line of fire while closing rail car doors. Pinky finger on right hand was smashed and required stitches. EE was coached by other EE's in the area on the proper way to perform the task prior to the incident.","sourceDate":"2011-02-26"},{"SOURCE_ROW_NUMBER":"138551","DOCUMENT_NO":"220110800043","ACCIDENT_DT":"02/10/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee lowered himself to the deck of a coal barge on the Spider Basket. Backlash occurred in the cable. When the employee attempted to go back down the basket dropped suddenly and injured the employee. The employee was stopped by the fall protection equipment he was wearing at the time of the incident.","sourceDate":"2011-02-10"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2010-04-14","lastDate":"2010-04-14","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":52,"firstDate":"2010-05-13","lastDate":"2026-03-24","metrics":{"ss":11,"delinquent":50,"recentRows":5,"paidPenalty":9904,"proposedPenalty":9904,"currentAssessment":9904},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2929309","VIOLATION_NO":"5011112","ISSUE_DT":"03/24/2026","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-24"},{"SOURCE_ROW_NUMBER":"2956110","VIOLATION_NO":"9781520","ISSUE_DT":"08/12/2024","CFR_STANDARD_CD":"50.30(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"2956109","VIOLATION_NO":"9578151","ISSUE_DT":"08/12/2024","CFR_STANDARD_CD":"48.27(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"2842075","VIOLATION_NO":"8451414","ISSUE_DT":"02/06/2022","CFR_STANDARD_CD":"77.1713(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-02-06"},{"SOURCE_ROW_NUMBER":"2842055","VIOLATION_NO":"9198709","ISSUE_DT":"09/12/2021","CFR_STANDARD_CD":"77.202","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-09-12"},{"SOURCE_ROW_NUMBER":"2789386","VIOLATION_NO":"9108803","ISSUE_DT":"09/10/2018","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-09-10"},{"SOURCE_ROW_NUMBER":"2789027","VIOLATION_NO":"9107027","ISSUE_DT":"09/05/2017","CFR_STANDARD_CD":"77.400(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"160.00","CURRENT_ASSESSMENT_AMT":"160.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-09-05"},{"SOURCE_ROW_NUMBER":"2004275","VIOLATION_NO":"9031875","ISSUE_DT":"02/01/2016","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-02-01"},{"SOURCE_ROW_NUMBER":"2004252","VIOLATION_NO":"9031850","ISSUE_DT":"09/08/2015","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-09-08"},{"SOURCE_ROW_NUMBER":"2004189","VIOLATION_NO":"8451486","ISSUE_DT":"02/09/2015","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-02-09"},{"SOURCE_ROW_NUMBER":"1199627","VIOLATION_NO":"8439232","ISSUE_DT":"11/25/2013","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-11-25"},{"SOURCE_ROW_NUMBER":"1199629","VIOLATION_NO":"8451411","ISSUE_DT":"11/13/2013","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-11-13"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":5,"firstDate":"2012-03-20","lastDate":"2013-07-31","metrics":{"appeals":0,"decisions":5,"recentRows":0,"decisionPenalty":200,"originalPenalty":11934},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"342353","VIOLATION_NO":"8420566","DOCKET_NO":"LAKE 2013-402","DECISION_DT":"07/31/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2013-07-31"},{"SOURCE_ROW_NUMBER":"76633","VIOLATION_NO":"8421116","DOCKET_NO":"LAKE 2011-995","DECISION_DT":"10/10/2012","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-10-10"},{"SOURCE_ROW_NUMBER":"78842","VIOLATION_NO":"8421110","DOCKET_NO":"LAKE 2012-114","DECISION_DT":"09/28/2012","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"9100.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2012-09-28"},{"SOURCE_ROW_NUMBER":"72620","VIOLATION_NO":"8424263","DOCKET_NO":"LAKE 2011-689","DECISION_DT":"04/20/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2012-04-20"},{"SOURCE_ROW_NUMBER":"303508","VIOLATION_NO":"8421109","DOCKET_NO":"LAKE 2011-753","DECISION_DT":"03/20/2012","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2012-03-20"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":223,"firstDate":"2010-09-21","lastDate":"2026-08-21","metrics":{"recentRows":80,"cpdmSamples":0,"voidSamples":1,"validSamples":222,"maxConcentration":2.212,"concentrationTotal":34.42},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1193270","CASS_NUM":"58555849","SMP_TAKEN_DT":"8/21/2026","CONC":".046","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MINE FOREMAN/MINE MANAGER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-21"},{"SOURCE_ROW_NUMBER":"745967","CASS_NUM":"58556296","SMP_TAKEN_DT":"8/21/2026","CONC":".068","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-21"},{"SOURCE_ROW_NUMBER":"265741","CASS_NUM":"58556308","SMP_TAKEN_DT":"8/21/2026","CONC":".041","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-21"},{"SOURCE_ROW_NUMBER":"225350","CASS_NUM":"58556294","SMP_TAKEN_DT":"8/21/2026","CONC":".059","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-21"},{"SOURCE_ROW_NUMBER":"116525","CASS_NUM":"58556292","SMP_TAKEN_DT":"8/21/2026","CONC":".076","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-21"},{"SOURCE_ROW_NUMBER":"499044","CASS_NUM":"51673630","SMP_TAKEN_DT":"7/8/2026","CONC":".049","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"1011764","CASS_NUM":"51678593","SMP_TAKEN_DT":"5/13/2026","CONC":".08","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-05-13"},{"SOURCE_ROW_NUMBER":"1643572","CASS_NUM":"58501678","SMP_TAKEN_DT":"2/12/2026","CONC":".089","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"1220285","CASS_NUM":"58501541","SMP_TAKEN_DT":"2/12/2026","CONC":".016","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MINE FOREMAN/MINE MANAGER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"772755","CASS_NUM":"58501739","SMP_TAKEN_DT":"2/12/2026","CONC":".17","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"445078","CASS_NUM":"58501726","SMP_TAKEN_DT":"2/12/2026","CONC":".089","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"1086067","CASS_NUM":"51639739","SMP_TAKEN_DT":"1/7/2026","CONC":".024","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-01-07"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":5,"firstDate":"2011-03-14","lastDate":"2013-01-28","metrics":{"decisions":5,"ssChanged":4,"recentRows":0,"decisionPenalty":200,"proposedPenalty":11934},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"311328","CITATION_NO":"8420566","CITATION_ISSUE_DT":"01/28/2013","DOCKET_NO":"LAKE 2013-402","DECISION_DT":"07/31/2013","CFR_STANDARD_CODE":"77.1605(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2013-01-28"},{"SOURCE_ROW_NUMBER":"77898","CITATION_NO":"8421116","CITATION_ISSUE_DT":"06/29/2011","DOCKET_NO":"LAKE 2011-995","DECISION_DT":"10/10/2012","CFR_STANDARD_CODE":"77.1403(b)(3)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":".00","sourceDate":"2011-06-29"},{"SOURCE_ROW_NUMBER":"363235","CITATION_NO":"8421110","CITATION_ISSUE_DT":"03/28/2011","DOCKET_NO":"LAKE 2012-114","DECISION_DT":"09/28/2012","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"9100.00","DECISION_PENALTY_AMT":".00","sourceDate":"2011-03-28"},{"SOURCE_ROW_NUMBER":"364880","CITATION_NO":"8421109","CITATION_ISSUE_DT":"03/17/2011","DOCKET_NO":"LAKE 2011-753","DECISION_DT":"03/20/2012","CFR_STANDARD_CODE":"77.1401","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":".00","sourceDate":"2011-03-17"},{"SOURCE_ROW_NUMBER":"250975","CITATION_NO":"8424263","CITATION_ISSUE_DT":"03/14/2011","DOCKET_NO":"LAKE 2011-689","DECISION_DT":"04/20/2012","CFR_STANDARD_CODE":"77.202","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2011-03-14"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":671,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":136,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2010-04-06","lastDate":"2017-02-22","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":46,"firstDate":"2010-05-13","lastDate":"2026-08-20","metrics":{"inspectors":104,"recentRows":17,"onSiteHours":1134.5,"inspectionHours":1996.25,"inspectionSamples":141},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"976054","EVENT_NO":"F0125B5","INSPECTION_BEGIN_DT":"08/20/2026","INSPECTION_END_DT":"08/21/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23.25","SUM_TOTAL_ON_SITE_HOURS":"15","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"338180","EVENT_NO":"F0095A7","INSPECTION_BEGIN_DT":"03/24/2026","INSPECTION_END_DT":"03/24/2026","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2026-03-24"},{"SOURCE_ROW_NUMBER":"143444","EVENT_NO":"F01259D","INSPECTION_BEGIN_DT":"02/10/2026","INSPECTION_END_DT":"02/12/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"39.75","SUM_TOTAL_ON_SITE_HOURS":"27","sourceDate":"2026-02-10"},{"SOURCE_ROW_NUMBER":"468906","EVENT_NO":"F012588","INSPECTION_BEGIN_DT":"07/28/2025","INSPECTION_END_DT":"08/06/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"36.25","SUM_TOTAL_ON_SITE_HOURS":"24","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"424434","EVENT_NO":"F01234B","INSPECTION_BEGIN_DT":"12/26/2024","INSPECTION_END_DT":"03/19/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"58.75","SUM_TOTAL_ON_SITE_HOURS":"37.75","sourceDate":"2024-12-26"},{"SOURCE_ROW_NUMBER":"825613","EVENT_NO":"F01233E","INSPECTION_BEGIN_DT":"08/12/2024","INSPECTION_END_DT":"09/04/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"60.5","SUM_TOTAL_ON_SITE_HOURS":"40","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"128071","EVENT_NO":"4257367","INSPECTION_BEGIN_DT":"05/22/2024","INSPECTION_END_DT":"05/22/2024","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2024-05-22"},{"SOURCE_ROW_NUMBER":"273753","EVENT_NO":"7023575","INSPECTION_BEGIN_DT":"03/02/2024","INSPECTION_END_DT":"03/20/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"61.5","SUM_TOTAL_ON_SITE_HOURS":"36","sourceDate":"2024-03-02"},{"SOURCE_ROW_NUMBER":"358160","EVENT_NO":"7031306","INSPECTION_BEGIN_DT":"12/06/2023","INSPECTION_END_DT":"12/06/2023","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2023-12-06"},{"SOURCE_ROW_NUMBER":"440535","EVENT_NO":"7023459","INSPECTION_BEGIN_DT":"09/08/2023","INSPECTION_END_DT":"09/25/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"50.75","SUM_TOTAL_ON_SITE_HOURS":"29","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"147366","EVENT_NO":"7006573","INSPECTION_BEGIN_DT":"05/17/2023","INSPECTION_END_DT":"05/17/2023","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2023-05-17"},{"SOURCE_ROW_NUMBER":"932615","EVENT_NO":"7022893","INSPECTION_BEGIN_DT":"03/21/2023","INSPECTION_END_DT":"03/21/2023","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2023-03-21"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":130,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":12237,"employees":23,"production":0},"2026-Q1":{"hours":13490,"employees":26,"production":0},"2025-Q4":{"hours":13391,"employees":26,"production":0},"2025-Q3":{"hours":12484,"employees":25,"production":0},"2025-Q2":{"hours":12412,"employees":25,"production":0},"2025-Q1":{"hours":13274,"employees":25,"production":0},"2024-Q4":{"hours":12972,"employees":25,"production":0},"2024-Q3":{"hours":13181,"employees":25,"production":0},"2024-Q2":{"hours":12846,"employees":25,"production":0},"2024-Q1":{"hours":13026,"employees":26,"production":0},"2023-Q4":{"hours":12029,"employees":26,"production":0},"2023-Q3":{"hours":12365,"employees":29,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":34,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":77524,"employees":39,"production":0},"2018":{"hours":62336,"employees":34,"production":0},"2019":{"hours":54292,"employees":27,"production":0},"2020":{"hours":50419,"employees":26,"production":0},"2021":{"hours":50784,"employees":27,"production":0},"2022":{"hours":54737,"employees":27,"production":0},"2023":{"hours":53012,"employees":28,"production":0},"2024":{"hours":52025,"employees":25,"production":0},"2025":{"hours":51561,"employees":25,"production":0},"2026":{"hours":25727,"employees":25,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":86,"firstDate":"2010-09-21","lastDate":"2026-02-12","metrics":{"recentRows":29,"doseOver100":1,"actDoseTotal":3049,"pelDoseTotal":1524},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"27494","EVENT_NO":"F01259D","SURVEY_DATE":"02/12/2026","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"20","ACT_DOSE_85":"19","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"27493","EVENT_NO":"F01259D","SURVEY_DATE":"02/12/2026","OCCUPATION_CD_DESC":"MINE FOREMAN/MINE MANAGER","MACHINE_CD":"40","ACT_DOSE_85":"7","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"27492","EVENT_NO":"F01259D","SURVEY_DATE":"02/12/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"27","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"27491","EVENT_NO":"F01259D","SURVEY_DATE":"02/12/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"37","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"27490","EVENT_NO":"F012588","SURVEY_DATE":"08/06/2025","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"20","ACT_DOSE_85":"8","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2025-08-06"},{"SOURCE_ROW_NUMBER":"27489","EVENT_NO":"F012588","SURVEY_DATE":"08/06/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"24","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2025-08-06"},{"SOURCE_ROW_NUMBER":"27488","EVENT_NO":"F012588","SURVEY_DATE":"08/06/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"27","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2025-08-06"},{"SOURCE_ROW_NUMBER":"27487","EVENT_NO":"F01234B","SURVEY_DATE":"02/19/2025","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"6","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2025-02-19"},{"SOURCE_ROW_NUMBER":"27486","EVENT_NO":"F01234B","SURVEY_DATE":"02/19/2025","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"6","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2025-02-19"},{"SOURCE_ROW_NUMBER":"27485","EVENT_NO":"F01234B","SURVEY_DATE":"02/19/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"80","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2025-02-19"},{"SOURCE_ROW_NUMBER":"27484","EVENT_NO":"7023575","SURVEY_DATE":"03/13/2024","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"8","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2024-03-13"},{"SOURCE_ROW_NUMBER":"27483","EVENT_NO":"7023575","SURVEY_DATE":"03/13/2024","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"31","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2024-03-13"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":13,"firstDate":"2016-02-01","lastDate":"2026-02-12","metrics":{"recentRows":5,"voidSamples":0,"maxQuartzPct":3.8,"validSamples":13,"quartzPctTotal":20.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"78497","CASSETTE_NO":"58501739","SAMPLE_DT":"02/12/2026","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"103304","CASSETTE_NO":"58501599","SAMPLE_DT":"02/19/2025","QUARTZ_PCT":"00.7","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-02-19"},{"SOURCE_ROW_NUMBER":"167872","CASSETTE_NO":"58501766","SAMPLE_DT":"08/15/2024","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2024-08-15"},{"SOURCE_ROW_NUMBER":"42177","CASSETTE_NO":"58501533","SAMPLE_DT":"08/15/2024","QUARTZ_PCT":"00.3","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2024-08-15"},{"SOURCE_ROW_NUMBER":"126869","CASSETTE_NO":"58521992","SAMPLE_DT":"03/13/2024","QUARTZ_PCT":"01.2","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2024-03-13"},{"SOURCE_ROW_NUMBER":"151159","CASSETTE_NO":"58325518","SAMPLE_DT":"09/17/2019","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-17"},{"SOURCE_ROW_NUMBER":"131476","CASSETTE_NO":"58325659","SAMPLE_DT":"09/17/2019","QUARTZ_PCT":"03.8","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-17"},{"SOURCE_ROW_NUMBER":"160448","CASSETTE_NO":"58353696","SAMPLE_DT":"03/20/2019","QUARTZ_PCT":"03.8","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-03-20"},{"SOURCE_ROW_NUMBER":"50442","CASSETTE_NO":"58353693","SAMPLE_DT":"03/20/2019","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-03-20"},{"SOURCE_ROW_NUMBER":"100650","CASSETTE_NO":"58296354","SAMPLE_DT":"02/26/2018","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-02-26"},{"SOURCE_ROW_NUMBER":"123308","CASSETTE_NO":"58284048","SAMPLE_DT":"09/05/2017","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-09-05"},{"SOURCE_ROW_NUMBER":"71167","CASSETTE_NO":"58284032","SAMPLE_DT":"09/05/2017","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-09-05"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":53,"firstDate":"2010-05-13","lastDate":"2026-03-24","metrics":{"ss":11,"amountDue":9904,"contested":0,"amountPaid":9904,"recentRows":5,"section104d":1,"unterminated":0,"proposedPenalty":9904},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"561036","VIOLATION_NO":"5011112","VIOLATION_ISSUE_DT":"03/24/2026","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/24/2026","PROPOSED_PENALTY":"366","AMOUNT_DUE":"366","AMOUNT_PAID":"366","CONTESTED_IND":"N","sourceDate":"2026-03-24"},{"SOURCE_ROW_NUMBER":"561054","VIOLATION_NO":"9781520","VIOLATION_ISSUE_DT":"08/12/2024","SIG_SUB":"N","PART_SECTION":"50.30(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/12/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"561053","VIOLATION_NO":"9578151","VIOLATION_ISSUE_DT":"08/12/2024","SIG_SUB":"N","PART_SECTION":"48.27(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/15/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"561087","VIOLATION_NO":"8451414","VIOLATION_ISSUE_DT":"02/06/2022","SIG_SUB":"N","PART_SECTION":"77.1713(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/06/2022","PROPOSED_PENALTY":"133","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2022-02-06"},{"SOURCE_ROW_NUMBER":"561058","VIOLATION_NO":"9198709","VIOLATION_ISSUE_DT":"09/12/2021","SIG_SUB":"N","PART_SECTION":"77.202","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/12/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"125","CONTESTED_IND":"N","sourceDate":"2021-09-12"},{"SOURCE_ROW_NUMBER":"561056","VIOLATION_NO":"9108803","VIOLATION_ISSUE_DT":"09/10/2018","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/10/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-09-10"},{"SOURCE_ROW_NUMBER":"561055","VIOLATION_NO":"9107027","VIOLATION_ISSUE_DT":"09/05/2017","SIG_SUB":"N","PART_SECTION":"77.400(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/05/2017","PROPOSED_PENALTY":"160","AMOUNT_DUE":"160","AMOUNT_PAID":"160","CONTESTED_IND":"N","sourceDate":"2017-09-05"},{"SOURCE_ROW_NUMBER":"561052","VIOLATION_NO":"9040003","VIOLATION_ISSUE_DT":"05/18/2016","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"07/11/2016","CONTESTED_IND":"N","sourceDate":"2016-05-18"},{"SOURCE_ROW_NUMBER":"561035","VIOLATION_NO":"9031875","VIOLATION_ISSUE_DT":"02/01/2016","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/01/2016","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2016-02-01"},{"SOURCE_ROW_NUMBER":"561057","VIOLATION_NO":"9031850","VIOLATION_ISSUE_DT":"09/08/2015","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-09-08"},{"SOURCE_ROW_NUMBER":"561066","VIOLATION_NO":"8451486","VIOLATION_ISSUE_DT":"02/09/2015","SIG_SUB":"N","PART_SECTION":"77.208(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-02-09"},{"SOURCE_ROW_NUMBER":"561067","VIOLATION_NO":"8439232","VIOLATION_ISSUE_DT":"11/25/2013","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/25/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-11-25"}]}],"safety":{"href":"/api/v1/mines/1103225/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1103225/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":26,"companyType":"Operating Subsidiary","components":[{"averageEmployees":13,"laborHours":26013,"mineType":"Surface","productionTons":0},{"averageEmployees":13,"laborHours":26012,"mineType":"Underground","productionTons":0}],"county":"St Clair","laborHours":52025,"mineName":"Watco Transloading/ Cahokia Te","mineType":"Surface + Underground","mshaId":"1103225","operatingAddress":"#2 Monsanto Avenute, Sauget, IL 62201","operatingCompany":"Watco Trans Loading Llc","operationType":"Preparation Plant","productionTons":0,"reportedRows":2,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Illinois","status":"Active","supplyRegion":"Illinois Basin","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":2},{"chapter":"I","heading":"Preparation and submission of MSHA Form 7000-2—Quarterly Employment and Coal Production Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-D/section-50.30","part":"50","subchapter":"I","subpart":"D","id":"50.30","citation":"30 CFR 50.30","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Training of miners assigned to a task in which they have had no previous experience; minimum courses of instruction.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.27","part":"48","subchapter":"H","subpart":"B","id":"48.27","citation":"30 CFR 48.27","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1713","heading":"Daily inspection of surface coal mine; certified person; reports of inspection.","id":"77.1713","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1713","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) At least once during each working shift, or more often if necessary for safety, each active working area and each active surface installation shall be examined by a certified person designated by the operator to conduct such examinations for hazardous conditions and any hazardous conditions noted during such examinations shall be reported to the operator and shall be corrected by the operator.\n\n(b) If any hazardous condition noted during an examination conducted in accordance with paragraph (a) of this section creates an imminent danger, the person conducting such examination shall notify the operator and the operator shall withdraw all persons from the area affected, except those persons referred to in section 104(d) of the Act, until the danger is abated.\n\n(c) After each examination conducted in accordance with the provisions of paragraph (a) of this section, each certified person who conducted all or any part of the examination required shall enter with ink or indelible pencil in a book approved by the Secretary the date and a report of the condition of the mine or any area of the mine which he has inspected together with a report of the nature and location of any hazardous condition found to be present at the mine. The book in which such entries are made shall be kept in an area at the mine designated by the operator to minimize the danger of destruction by fire or other hazard.\n\n(d) All examination reports recorded in accordance with the provisions of paragraph (c) of this section shall include a report of the action taken to abate hazardous conditions and shall be signed or countersigned each day by at least one of the following persons:\n\n(1) The surface mine foreman;\n\n(2) The assistant superintendent of the mine;\n\n(3) The superintendent of the mine;\n\n(4) The person designated by the operator as responsible for health and safety at the mine; or,\n\n(5) An equivalent mine official.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995; 63 FR 58613, Oct. 30, 1998]","occurrenceCount":1},{"chapter":"I","heading":"Dust accumulations in surface installations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.202","part":"77","subchapter":"O","subpart":"C","id":"77.202","citation":"30 CFR 77.202","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1103225","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}