{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1103203","name":"MINE NO. 1","status":"Active","status_date":"2020-05-04","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IL","county":"Hamilton","nearest_town":"Dahlgren","operator_id":"0119792","operator_name":"HAMILTON COUNTY COAL, LLC","controller_id":"C15455","controller_name":"Alliance Resource Partners LP","district":"C08","office":"Marion IL Field Office","employees":334,"latitude":38.171111,"longitude":-88.601667},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":25183},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1103203","name":"MINE NO. 1"},"operator":{"type":"operator","id":"0119792","name":"HAMILTON COUNTY COAL, LLC"},"controller":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0115525","name":"White Oak Resources LLC"},"object":{"type":"mine","id":"1103203","name":"MINE NO. 1"},"validFrom":"2010-12-01","validTo":"2015-07-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103203|0115525|2010-12-01|2015-07-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0097933","name":"Medlock C J Family Ltd Ptnrship et al"},"object":{"type":"mine","id":"1103203","name":"MINE NO. 1"},"validFrom":"2010-12-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103203|0097933|2010-12-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0097933","name":"Medlock C J Family Ltd Ptnrship et al"},"object":{"type":"operator","id":"0115525","name":"White Oak Resources LLC"},"validFrom":"2010-12-01","validTo":"2015-07-31","current":false,"derived":true,"evidenceMineId":"1103203","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103203|0115525|2010-12-01|0097933|2010-12-01|16033"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0097933","name":"Christopher M  James et al"},"object":{"type":"operator","id":"0115525","name":"White Oak Resources LLC"},"validFrom":"2010-12-01","validTo":"2015-07-31","current":false,"derived":true,"evidenceMineId":"1103203","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103203|0115525|2010-12-01|0097933|2010-12-01|16034"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"mine","id":"1103203","name":"MINE NO. 1"},"validFrom":"2011-10-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103203|C15455|2011-10-10|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0119792","name":"Hamilton County Coal, LLC"},"object":{"type":"mine","id":"1103203","name":"MINE NO. 1"},"validFrom":"2015-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103203|0119792|2015-08-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"operator","id":"0119792","name":"Hamilton County Coal, LLC"},"validFrom":"2015-08-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1103203","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103203|0119792|2015-08-01|C15455|2011-10-10|95678"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":321,"firstDate":"2011-06-08","lastDate":"2026-09-26","metrics":{"daysLost":9497,"injuries":280,"fatalities":3,"recentRows":123,"restrictedDays":1007,"contractorRecords":43},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"254779","DOCUMENT_NO":"220262720019","ACCIDENT_DT":"09/26/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Loading a mandoor into a mantrip, EE had a hand on the edge of the mandoor causing them to hit their left thumb against the canopy post of the mantrip resulting in a laceration on their left thumb across the nail. Causing them to received stitches.","sourceDate":"2026-09-26"},{"SOURCE_ROW_NUMBER":"108194","DOCUMENT_NO":"220262570004","ACCIDENT_DT":"09/09/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While carrying a 12' timber, EE tripped over a plaster bag, as EE fell the timber smashed EE's left ring finger between the timber and a pallet of blocks. Causing a small fracture at the tip of EE's finger and EE received stitches.","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"237557","DOCUMENT_NO":"220262530006","ACCIDENT_DT":"09/02/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","NARRATIVE":"The operator was getting ready to tram the bolter back to install another bolt in the mine roof. EE was in the process of stepping off the back of the elevated walk way on the back of the bolter. As EE stepped off the elevated platform/walkway with EE's left foot, to pull the bolter cable back, EE stepped on a loose slick rock which caused ankle to slide sideways.","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"151519","DOCUMENT_NO":"220262190010","ACCIDENT_DT":"08/03/2026","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","NARRATIVE":"Another crew member picked up a tub full of high voltage cable to move power for the longwall. That EE placed the tub in a crosscut so EE unhooked the chain to free up the 495 but the tub shifted and the chain snapped against itself amputating EE's left index finger at the knuckle.","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"125352","DOCUMENT_NO":"220262190011","ACCIDENT_DT":"08/01/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"While removing an 8\" block off a pallet of blocks to build a stopping, a block rolled off striking EE in the left foot between the steel toe and metatarsal of EE's mining boots.","sourceDate":"2026-08-01"},{"SOURCE_ROW_NUMBER":"147240","DOCUMENT_NO":"220261950039","ACCIDENT_DT":"07/14/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Janitor","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Employee was collecting trash from receptacles in employee parking lot and putting the trash in a pickup truck. They exited the truck to pick up trash and while employee was outside the vehicle, the truck began to roll backwards. They tried to jump into the truck to stop it and while doing so, tripped. The truck rolled over their right leg and fractured their right foot.","sourceDate":"2026-07-14"},{"SOURCE_ROW_NUMBER":"267596","DOCUMENT_NO":"220261590038","ACCIDENT_DT":"06/06/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Adverse roof conditions due to abutment pressures at District #4, #3 entry at crosscut #94. This condition was evaluated by management and a decision was made to declare and implement Hamilton's blocked tailgate plan for safety.","sourceDate":"2026-06-06"},{"SOURCE_ROW_NUMBER":"134121","DOCUMENT_NO":"220261520022","ACCIDENT_DT":"05/30/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall occurred on the District #4 Tailgate in #3 entry, 30 feet inby crosscut #95 due to adverse roof conditions and abutment pressures blocking off access of the longwall tailgate.","sourceDate":"2026-05-30"},{"SOURCE_ROW_NUMBER":"164439","DOCUMENT_NO":"220261390014","ACCIDENT_DT":"05/15/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"Was removing a shield leg jack when the jack swung around and hit EE's right ankle, catching both legs between the cell plate the shield foot.","sourceDate":"2026-05-15"},{"SOURCE_ROW_NUMBER":"177340","DOCUMENT_NO":"220261390009","ACCIDENT_DT":"05/13/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"24","NARRATIVE":"Walking across the 650 duckbill to grab cribs for relay bar. EE stepped off the duckbill into a hole and twisted EE's left ankle.","sourceDate":"2026-05-13"},{"SOURCE_ROW_NUMBER":"220349","DOCUMENT_NO":"220260890066","ACCIDENT_DT":"03/21/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall occurred at District #4 Headgate #1, #2 Entry, Crosscut #62 in the Intersection outby the Section Loading Point.","sourceDate":"2026-03-21"},{"SOURCE_ROW_NUMBER":"52565","DOCUMENT_NO":"220260890034","ACCIDENT_DT":"03/20/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"HOISTING","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A small distortion was found on the rope during the slope hoist rope examination at the 355 foot mark behind the brakeman car.","sourceDate":"2026-03-20"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-05-04","lastDate":"2020-05-04","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":2609,"firstDate":"2011-08-11","lastDate":"2026-08-28","metrics":{"ss":505,"delinquent":2504,"recentRows":966,"paidPenalty":1330466.54,"proposedPenalty":1832175,"currentAssessment":1365679},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2934807","VIOLATION_NO":"5222113","ISSUE_DT":"08/28/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"2934808","VIOLATION_NO":"5222112","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"2934806","VIOLATION_NO":"5222110","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"209.00","CURRENT_ASSESSMENT_AMT":"209.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"2934805","VIOLATION_NO":"5222109","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"2934797","VIOLATION_NO":"5046576","ISSUE_DT":"08/20/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1550.00","CURRENT_ASSESSMENT_AMT":"1550.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2934804","VIOLATION_NO":"5222108","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.1911(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2934803","VIOLATION_NO":"5222107","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"209.00","CURRENT_ASSESSMENT_AMT":"209.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2934802","VIOLATION_NO":"5222106","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.1910(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2934801","VIOLATION_NO":"5222105","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.1911(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2934800","VIOLATION_NO":"5222104","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"209.00","CURRENT_ASSESSMENT_AMT":"209.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2934779","VIOLATION_NO":"5017211","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"77.1303(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"642.00","CURRENT_ASSESSMENT_AMT":"642.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2934796","VIOLATION_NO":"5046575","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-11"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":410,"firstDate":"2013-09-13","lastDate":"2026-06-12","metrics":{"appeals":0,"decisions":397,"recentRows":87,"decisionPenalty":627782,"originalPenalty":1131474},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"446675","VIOLATION_NO":"9545120","DOCKET_NO":"LAKE 2024-0090","DECISION_DT":"06/12/2026","DECISION_TYPE_CODE_DESC":"Vacate","ORIGINAL_PENALTY_AMT":"12684.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-12"},{"SOURCE_ROW_NUMBER":"446364","VIOLATION_NO":"9542559","DOCKET_NO":"LAKE 2024-0089","DECISION_DT":"06/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"407.00","DECISION_PENALTY_AMT":"189.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-12"},{"SOURCE_ROW_NUMBER":"445478","VIOLATION_NO":"9546681","DOCKET_NO":"LAKE 2024-0089","DECISION_DT":"06/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"772.00","DECISION_PENALTY_AMT":"357.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-12"},{"SOURCE_ROW_NUMBER":"445477","VIOLATION_NO":"9546595","DOCKET_NO":"LAKE 2024-0089","DECISION_DT":"06/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"834.00","DECISION_PENALTY_AMT":"417.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-12"},{"SOURCE_ROW_NUMBER":"159808","VIOLATION_NO":"9545118","DOCKET_NO":"LAKE 2024-0147","DECISION_DT":"06/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"88354.00","DECISION_PENALTY_AMT":"66000.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-12"},{"SOURCE_ROW_NUMBER":"158861","VIOLATION_NO":"9545119","DOCKET_NO":"LAKE 2024-0090","DECISION_DT":"06/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"14886.00","DECISION_PENALTY_AMT":"14886.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-12"},{"SOURCE_ROW_NUMBER":"158648","VIOLATION_NO":"9545121","DOCKET_NO":"LAKE 2024-0089","DECISION_DT":"06/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3080.00","DECISION_PENALTY_AMT":"3080.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-12"},{"SOURCE_ROW_NUMBER":"167596","VIOLATION_NO":"9786098","DOCKET_NO":"LAKE 2026-0036","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5574.00","DECISION_PENALTY_AMT":"1819.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"164259","VIOLATION_NO":"9786233","DOCKET_NO":"LAKE 2025-0149","DECISION_DT":"06/03/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"281.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-06-03"},{"SOURCE_ROW_NUMBER":"164258","VIOLATION_NO":"9786229","DOCKET_NO":"LAKE 2025-0149","DECISION_DT":"06/03/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1219.00","DECISION_PENALTY_AMT":"536.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-06-03"},{"SOURCE_ROW_NUMBER":"164257","VIOLATION_NO":"9786109","DOCKET_NO":"LAKE 2025-0149","DECISION_DT":"06/03/2026","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-06-03"},{"SOURCE_ROW_NUMBER":"459691","VIOLATION_NO":"9786947","DOCKET_NO":"LAKE 2025-0337","DECISION_DT":"05/29/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3184.00","DECISION_PENALTY_AMT":"2388.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-05-29"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":10694,"firstDate":"2011-08-12","lastDate":"2026-10-07","metrics":{"recentRows":5428,"cpdmSamples":8424,"voidSamples":2513,"validSamples":8181,"maxConcentration":34.512,"concentrationTotal":6194.214},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3028698","SMP_TAKEN_DT":"10/7/2026","CONC":".735","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2858702","SMP_TAKEN_DT":"10/7/2026","CONC":".486","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2517143","SMP_TAKEN_DT":"10/7/2026","CONC":".296","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2431946","SMP_TAKEN_DT":"10/7/2026","CONC":".749","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2431895","SMP_TAKEN_DT":"10/7/2026","CONC":".861","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1920904","SMP_TAKEN_DT":"10/7/2026","CONC":".994","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1920900","SMP_TAKEN_DT":"10/7/2026","CONC":".625","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1835929","SMP_TAKEN_DT":"10/7/2026","CONC":".422","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1835928","SMP_TAKEN_DT":"10/7/2026","CONC":".385","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"3029180","SMP_TAKEN_DT":"10/6/2026","CONC":".734","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"3029178","SMP_TAKEN_DT":"10/6/2026","CONC":".462","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"3029177","SMP_TAKEN_DT":"10/6/2026","CONC":".93","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":51,"firstDate":"2013-12-13","lastDate":"2025-11-18","metrics":{"linkedIssuances":51},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":411,"firstDate":"2013-03-27","lastDate":"2026-07-22","metrics":{"decisions":398,"ssChanged":56,"recentRows":96,"decisionPenalty":628582,"proposedPenalty":1156062},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"393145","CITATION_NO":"5046566","CITATION_ISSUE_DT":"07/22/2026","DOCKET_NO":"LAKE 2026-0212","CFR_STANDARD_CODE":"48.11(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"959.00","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"280600","CITATION_NO":"5044444","CITATION_ISSUE_DT":"07/15/2026","DOCKET_NO":"LAKE 2026-0211","CFR_STANDARD_CODE":"75.1909(a)(10)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"465.00","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"393283","CITATION_NO":"5016180","CITATION_ISSUE_DT":"06/16/2026","DOCKET_NO":"LAKE 2026-0202","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"12403.00","sourceDate":"2026-06-16"},{"SOURCE_ROW_NUMBER":"394547","CITATION_NO":"5046554","CITATION_ISSUE_DT":"04/28/2026","DOCKET_NO":"LAKE 2026-0152","CFR_STANDARD_CODE":"75.1909(a)(10)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"465.00","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"394158","CITATION_NO":"5046553","CITATION_ISSUE_DT":"04/28/2026","DOCKET_NO":"LAKE 2026-0152","CFR_STANDARD_CODE":"75.1910(i)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"465.00","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"223391","CITATION_NO":"5044425","CITATION_ISSUE_DT":"04/28/2026","DOCKET_NO":"LAKE 2026-0152","CFR_STANDARD_CODE":"75.1910(i)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"465.00","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"166725","CITATION_NO":"5046555","CITATION_ISSUE_DT":"04/28/2026","DOCKET_NO":"LAKE 2026-0152","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"697.00","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"111658","CITATION_NO":"5044426","CITATION_ISSUE_DT":"04/28/2026","DOCKET_NO":"LAKE 2026-0152","CFR_STANDARD_CODE":"75.1909(a)(10)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"465.00","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"393249","CITATION_NO":"5044423","CITATION_ISSUE_DT":"04/23/2026","DOCKET_NO":"LAKE 2026-0152","CFR_STANDARD_CODE":"75.1909(a)(10)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"465.00","sourceDate":"2026-04-23"},{"SOURCE_ROW_NUMBER":"393250","CITATION_NO":"5044418","CITATION_ISSUE_DT":"04/16/2026","DOCKET_NO":"LAKE 2026-0152","CFR_STANDARD_CODE":"75.1910(i)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"465.00","sourceDate":"2026-04-16"},{"SOURCE_ROW_NUMBER":"223746","CITATION_NO":"5044419","CITATION_ISSUE_DT":"04/16/2026","DOCKET_NO":"LAKE 2026-0152","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"697.00","sourceDate":"2026-04-16"},{"SOURCE_ROW_NUMBER":"109073","CITATION_NO":"5011165","CITATION_ISSUE_DT":"10/30/2025","DOCKET_NO":"LAKE 2026-0037","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3184.00","sourceDate":"2025-10-30"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":4472,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":23,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":997,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":23,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2010-12-01","lastDate":"2015-08-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":1149,"firstDate":"2011-06-07","lastDate":"2026-10-08","metrics":{"inspectors":1884,"recentRows":528,"onSiteHours":32929,"inspectionHours":57053,"inspectionSamples":2738},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"560314","EVENT_NO":"F020883","INSPECTION_BEGIN_DT":"10/08/2026","INSPECTION_END_DT":"10/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"970352","EVENT_NO":"F020882","INSPECTION_BEGIN_DT":"10/06/2026","INSPECTION_END_DT":"10/06/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"898923","EVENT_NO":"F00B70F","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"45.5","SUM_TOTAL_ON_SITE_HOURS":"26.75","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"853519","EVENT_NO":"7007173","INSPECTION_BEGIN_DT":"09/30/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"740450","EVENT_NO":"F020881","INSPECTION_BEGIN_DT":"09/29/2026","INSPECTION_END_DT":"09/29/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"299616","EVENT_NO":"F00B70E","INSPECTION_BEGIN_DT":"09/23/2026","INSPECTION_END_DT":"09/23/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.25","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2026-09-23"},{"SOURCE_ROW_NUMBER":"478224","EVENT_NO":"F00B70D","INSPECTION_BEGIN_DT":"09/21/2026","INSPECTION_END_DT":"09/21/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2026-09-21"},{"SOURCE_ROW_NUMBER":"870585","EVENT_NO":"F00B70C","INSPECTION_BEGIN_DT":"09/16/2026","INSPECTION_END_DT":"09/16/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.75","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"1030961","EVENT_NO":"F017C2C","INSPECTION_BEGIN_DT":"09/08/2026","INSPECTION_END_DT":"09/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"643076","EVENT_NO":"F017C2B","INSPECTION_BEGIN_DT":"09/03/2026","INSPECTION_END_DT":"09/03/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"1078218","EVENT_NO":"F017C2A","INSPECTION_BEGIN_DT":"09/01/2026","INSPECTION_END_DT":"09/01/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"608288","EVENT_NO":"F0095BA","INSPECTION_BEGIN_DT":"09/01/2026","INSPECTION_END_DT":"09/01/2026","ACTIVITY_CODE":"E18","ACTIVITY":"Shaft, Slope or Major Construction Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2026-09-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":180,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":202743,"employees":343,"production":928474},"2026-Q1":{"hours":207413,"employees":351,"production":696429},"2025-Q4":{"hours":189166,"employees":345,"production":1787789},"2025-Q3":{"hours":201132,"employees":341,"production":1578423},"2025-Q2":{"hours":205559,"employees":356,"production":1404637},"2025-Q1":{"hours":205239,"employees":355,"production":1699823},"2024-Q4":{"hours":196664,"employees":359,"production":815393},"2024-Q3":{"hours":214159,"employees":367,"production":1087841},"2024-Q2":{"hours":217899,"employees":374,"production":1359411},"2024-Q1":{"hours":234407,"employees":391,"production":1510540},"2023-Q4":{"hours":208904,"employees":376,"production":1312320},"2023-Q3":{"hours":207552,"employees":359,"production":1247157}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":45,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":773087,"employees":298,"production":6129347},"2018":{"hours":780545,"employees":319,"production":6298997},"2019":{"hours":764759,"employees":278,"production":5889105},"2020":{"hours":404994,"employees":183,"production":2623205},"2021":{"hours":550539,"employees":205,"production":4938788},"2022":{"hours":702992,"employees":282,"production":4693251},"2023":{"hours":815242,"employees":333,"production":5624399},"2024":{"hours":863129,"employees":373,"production":4773185},"2025":{"hours":801096,"employees":349,"production":6470672},"2026":{"hours":410156,"employees":348,"production":1624903}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":545,"firstDate":"2011-09-09","lastDate":"2026-09-08","metrics":{"recentRows":184,"doseOver100":93,"actDoseTotal":40244,"pelDoseTotal":30603},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"27265","EVENT_NO":"F00B704","SURVEY_DATE":"09/08/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"65","PEL_DOSE_90":"90","SURVEY_TYPE":"I","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"27264","EVENT_NO":"F00B704","SURVEY_DATE":"09/08/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"62","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"27263","EVENT_NO":"F00B704","SURVEY_DATE":"09/08/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"23","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"27262","EVENT_NO":"F00B704","SURVEY_DATE":"09/08/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"28","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"27270","EVENT_NO":"F017200","SURVEY_DATE":"05/20/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"46","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"27269","EVENT_NO":"F017200","SURVEY_DATE":"05/20/2026","OCCUPATION_CD_DESC":"WATER TRUCK OPERATOR","MACHINE_CD":"38","ACT_DOSE_85":"80","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"27268","EVENT_NO":"F017200","SURVEY_DATE":"05/20/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","ACT_DOSE_85":"90","PEL_DOSE_90":"88","SURVEY_TYPE":"I","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"27267","EVENT_NO":"F017200","SURVEY_DATE":"05/20/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"39","ACT_DOSE_85":"57","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"27266","EVENT_NO":"F017200","SURVEY_DATE":"05/20/2026","OCCUPATION_CD_DESC":"ASSIST MINE FOREMAN/ASSIST MINE MANAGER","MACHINE_CD":"40","ACT_DOSE_85":"36","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"27261","EVENT_NO":"F00B6ED","SURVEY_DATE":"01/06/2026","OCCUPATION_CD_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","MACHINE_CD":"27","ACT_DOSE_85":"107","PEL_DOSE_90":"95","SURVEY_TYPE":"I","sourceDate":"2026-01-06"},{"SOURCE_ROW_NUMBER":"27260","EVENT_NO":"F00B6ED","SURVEY_DATE":"01/06/2026","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","ACT_DOSE_85":"91","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2026-01-06"},{"SOURCE_ROW_NUMBER":"27259","EVENT_NO":"F00B6ED","SURVEY_DATE":"01/06/2026","OCCUPATION_CD_DESC":"HEADGATE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"59","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2026-01-06"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":609,"firstDate":"2014-03-12","lastDate":"2026-09-14","metrics":{"recentRows":336,"voidSamples":25,"maxQuartzPct":9.8,"validSamples":584,"quartzPctTotal":1751.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"115902","CASSETTE_NO":"58590855","SAMPLE_DT":"09/14/2026","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"30784","CASSETTE_NO":"58591147","SAMPLE_DT":"09/14/2026","QUARTZ_PCT":"00.7","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"9692","CASSETTE_NO":"58591400","SAMPLE_DT":"09/14/2026","QUARTZ_PCT":"00.6","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"162365","CASSETTE_NO":"58591064","SAMPLE_DT":"09/08/2026","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"120501","CASSETTE_NO":"58591055","SAMPLE_DT":"09/08/2026","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"114887","CASSETTE_NO":"58591145","SAMPLE_DT":"09/08/2026","QUARTZ_PCT":"02.4","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"46394","CASSETTE_NO":"58590863","SAMPLE_DT":"09/08/2026","QUARTZ_PCT":"01.1","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"115852","CASSETTE_NO":"58591195","SAMPLE_DT":"07/15/2026","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"107839","CASSETTE_NO":"58591199","SAMPLE_DT":"07/15/2026","QUARTZ_PCT":"01.4","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"96776","CASSETTE_NO":"58591281","SAMPLE_DT":"07/15/2026","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"13","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"86537","CASSETTE_NO":"58591315","SAMPLE_DT":"07/15/2026","QUARTZ_PCT":"01.0","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"HEADGATE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"24603","CASSETTE_NO":"58591200","SAMPLE_DT":"07/15/2026","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-15"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":2685,"firstDate":"2011-08-11","lastDate":"2026-10-08","metrics":{"ss":509,"amountDue":1365679,"contested":0,"amountPaid":1330466.54,"recentRows":1004,"section104d":8,"unterminated":0,"proposedPenalty":1832175},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"559900","VIOLATION_NO":"5046924","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.1714-7(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"559690","VIOLATION_NO":"5222122","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"559471","VIOLATION_NO":"5046923","VIOLATION_ISSUE_DT":"09/29/2026","SIG_SUB":"Y","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/29/2026","CONTESTED_IND":"N","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"559334","VIOLATION_NO":"5222121","VIOLATION_ISSUE_DT":"09/17/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/21/2026","CONTESTED_IND":"N","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"559333","VIOLATION_NO":"5222120","VIOLATION_ISSUE_DT":"09/17/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/21/2026","CONTESTED_IND":"N","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"559332","VIOLATION_NO":"5222119","VIOLATION_ISSUE_DT":"09/17/2026","SIG_SUB":"N","PART_SECTION":"75.1911(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/21/2026","CONTESTED_IND":"N","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"559315","VIOLATION_NO":"5046581","VIOLATION_ISSUE_DT":"09/16/2026","SIG_SUB":"Y","PART_SECTION":"75.1914(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2026","CONTESTED_IND":"N","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"559331","VIOLATION_NO":"5222118","VIOLATION_ISSUE_DT":"09/15/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2026","CONTESTED_IND":"N","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"559314","VIOLATION_NO":"5046580","VIOLATION_ISSUE_DT":"09/15/2026","SIG_SUB":"Y","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2026","CONTESTED_IND":"N","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"559330","VIOLATION_NO":"5222117","VIOLATION_ISSUE_DT":"09/02/2026","SIG_SUB":"N","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/02/2026","CONTESTED_IND":"N","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"559329","VIOLATION_NO":"5222116","VIOLATION_ISSUE_DT":"09/02/2026","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/02/2026","CONTESTED_IND":"N","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"559313","VIOLATION_NO":"5046579","VIOLATION_ISSUE_DT":"09/02/2026","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/02/2026","CONTESTED_IND":"N","sourceDate":"2026-09-02"}]}],"safety":{"href":"/api/v1/mines/1103203/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1103203/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":373,"companyType":"Operating Subsidiary","components":[{"averageEmployees":373,"laborHours":863129,"mineType":"Underground","productionTons":4773185}],"county":"Hamilton","laborHours":863129,"mineName":"Mine No. 1","mineType":"Underground","mshaId":"1103203","operatingAddress":"18033 County Road 500 East, Dahlgren, IL 62828","operatingCompany":"Hamilton County Coal, Llc","operationType":"Mine only","productionTons":4773185,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Illinois","status":"Active","supplyRegion":"Illinois Basin","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Multi-gas detectors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-7","part":"75","subchapter":"O","subpart":"R","id":"75.1714-7","citation":"30 CFR 75.1714-7","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1911","heading":"Fire suppression systems for diesel-powered equipment and fuel transportation units.","id":"75.1911","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1911","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) The fire suppression system required by §§ 75.1907 and 75.1909 shall be a multipurpose dry chemical type (ABC) fire suppression system listed or approved by a nationally recognized independent testing laboratory and appropriate for installation on diesel-powered equipment and fuel transportation units.\n\n(1) The system shall be installed in accordance with the manufacturer's specifications and the limitations of the listing or approval.\n\n(2) The system shall be installed in a protected location or guarded to minimize physical damage from routine vehicle operations.\n\n(3) Suppressant agent distribution tubing or piping shall be secured and protected against damage, including pinching, crimping, stretching, abrasion, and corrosion.\n\n(4) Discharge nozzles shall be positioned and aimed for maximum fire suppression effectiveness. Nozzles shall also be protected against the entrance of foreign materials such as mud, coal dust, or rock dust.\n\n(b) The fire suppression system shall provide fire suppression and, if automatic, fire detection for the engine including the starter, transmission, hydraulic pumps and tanks, fuel tanks, exposed brake units, air compressors and battery areas on diesel-powered equipment and electric panels or controls used on fuel transportation units and other areas as necessary.\n\n(c) If automatic, the fire suppression system shall include audible and visual alarms to warn of fires or system faults.\n\n(d) The fire suppression system shall provide for automatic engine shutdown. If the fire suppression system is automatic, engine shutdown and discharge of suppressant agent may be delayed for a maximum of 15 seconds after the fire is detected by the system.\n\n(e) The fire suppression system shall be operable by at least two manual actuators. One actuator shall be located on each side of the equipment. If the equipment is provided with an operator's compartment, one of the manual actuators shall be located in the compartment within reach of the operator.\n\n(f) The fire suppression system shall remain operative in the event of engine shutdown, equipment electrical system failure, or failure of any other equipment system.\n\n(g) The electrical components of each fire suppression system installed on equipment used where permissible electric equipment is required shall be permissible or intrinsically safe and such components shall be maintained in permissible or intrinsically safe condition.\n\n(h) Electrically operated detection and actuation circuits shall be monitored and provided with status indicators showing power and circuit continuity. If the system is not electrically operated, a means shall be provided to indicate the functional readiness status of the detection system.\n\n(i) Each fire suppression system shall be tested and maintained in accordance with the manufacturer's recommended inspection and maintenance program and as required by the nationally recognized independent testing laboratory listing or approval, and be visually inspected at least once each week by a person trained to make such inspections.\n\n(j) Recordkeeping. Persons performing inspections and tests of fire suppression systems under paragraph (i) shall record when a fire suppression system does not meet the installation or maintenance requirements of this section.\n\n(1) The record shall include the equipment on which the fire suppression system did not meet the installation or maintenance requirements of this section, the defect found, and the corrective action taken.\n\n(2) Records are to be kept manually in a secure manner not susceptible to alteration or recorded electronically in a secured computer system that is not susceptible to alteration.\n\n(3) Records shall be maintained at a surface location at the mine for one year and made available for inspection by an authorized representative of the Secretary and miners' representatives.\n\n(k) All miners normally assigned to the active workings of the mine shall be instructed about the hazards inherent to the operation of the fire suppression systems and, where appropriate, the safeguards available for each system.\n\n(l) For purposes of § 75.380(f), a fire suppression system installed on diesel-powered equipment and meeting the requirements of this section is equivalent to a fire suppression system meeting the requirements of §§ 75.1107-3 through 75.1107-16.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1914","heading":"Maintenance of diesel-powered equipment.","id":"75.1914","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1914","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Diesel-powered equipment shall be maintained in approved and safe condition or removed from service.\n\n(b) Maintenance and repairs of approved features and those features required by §§ 75.1909 and 75.1910 on diesel-powered equipment shall be made only by a person qualified under § 75.1915.\n\n(c) The water scrubber system on diesel-powered equipment shall be drained and flushed, by a person who is trained to perform this task, at least once on each shift in which the equipment is operated.\n\n(d) The intake air filter on diesel-powered equipment shall be replaced or serviced, by a person who is trained to perform this task, when the intake air pressure drop device so indicates or when the engine manufacturer's maximum allowable air pressure drop level is exceeded.\n\n(e) Mobile diesel-powered equipment that is to be used during a shift shall be visually examined by the equipment operator before being placed in operation. Equipment defects affecting safety shall be reported promptly to the mine operator.\n\n(f) All diesel-powered equipment shall be examined and tested weekly by a person qualified under § 75.1915.\n\n(1) Examinations and tests shall be conducted in accordance with approved checklists and manufacturers' maintenance manuals.\n\n(2) Persons performing weekly examinations and tests of diesel-powered equipment under this paragraph shall make a record when the equipment is not in approved or safe condition. The record shall include the equipment that is not in approved or safe condition, the defect found, and the corrective action taken.\n\n(g) Undiluted exhaust emissions of diesel engines in diesel-powered equipment approved under part 36 and heavy-duty nonpermissible diesel-powered equipment as defined in § 75.1908(a) in use in underground coal mines shall be tested and evaluated weekly by a person who is trained to perform this task. The mine operator shall develop and implement written standard operating procedures for such testing and evaluation that specify the following:\n\n(1) The method of achieving a repeatable loaded engine operating condition for each type of equipment;\n\n(2) Sampling and analytical methods (including calibration of instrumentation) that are capable of accurately detecting carbon monoxide in the expected concentrations;\n\n(3) The method of evaluation and interpretation of the results;\n\n(4) The concentration or changes in concentration of carbon monoxide that will indicate a change in engine performance. Carbon monoxide concentration shall not exceed 2500 parts per million; and\n\n(5) The maintenance of records necessary to track engine performance.\n\n(h) Recordkeeping. Records required by paragraphs (f)(2) and (g)(5) shall be—\n\n(1) Recorded in a secure book that is not susceptible to alteration, or recorded electronically in a computer system that is secure and not susceptible to alteration; and\n\n(2) Retained at a surface location at the mine for at least 1 year and made available for inspection by an authorized representative of the Secretary and by miners' representatives.\n\n(i) Diesel-powered equipment must be maintained in accordance with this part as of November 25, 1997.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1103203","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}