{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"1103189","name":"MC#1 Mine","status":"Active","status_date":"2022-01-11","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IL","county":"Franklin","nearest_town":"Thompsonville","operator_id":"0088324","operator_name":"M-Class Mining LLC","controller_id":"0129681","controller_name":"Foresight Energy Labor LLC","district":"C08","office":"Marion IL Field Office","employees":197,"latitude":38.026944,"longitude":-88.762222},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":42967},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1103189","name":"MC#1 Mine"},"operator":{"type":"operator","id":"0088324","name":"M-Class Mining LLC"},"controller":{"type":"controller","id":"0129681","name":"Foresight Energy Labor LLC"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0088324","name":"M-Class Mining LLC"},"object":{"type":"mine","id":"1103189","name":"MC#1 Mine"},"validFrom":"2008-03-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1103189|0088324|2008-03-26|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0059869","name":"Coalfield Transport Inc et al"},"object":{"type":"mine","id":"1103189","name":"MC#1 Mine"},"validFrom":"2008-03-26","validTo":"2016-07-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1103189|0059869|2008-03-26|2016-07-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0059869","name":"Coalfield Transport Inc et al"},"object":{"type":"operator","id":"0088324","name":"M-Class Mining LLC"},"validFrom":"2008-03-26","validTo":"2016-07-31","current":false,"derived":true,"evidenceMineId":"1103189","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1103189|0088324|2008-03-26|0059869|2008-03-26|7972"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0059869","name":"Foresight Energy/ Murray Energy et al"},"object":{"type":"operator","id":"0088324","name":"M-Class Mining LLC"},"validFrom":"2008-03-26","validTo":"2016-07-31","current":false,"derived":true,"evidenceMineId":"1103189","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1103189|0088324|2008-03-26|0059869|2008-03-26|7973"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0129681","name":"Foresight Energy Labor LLC"},"object":{"type":"mine","id":"1103189","name":"MC#1 Mine"},"validFrom":"2016-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1103189|0129681|2016-08-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0129681","name":"Foresight Energy Labor LLC"},"object":{"type":"operator","id":"0088324","name":"M-Class Mining LLC"},"validFrom":"2016-08-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1103189","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1103189|0088324|2008-03-26|0129681|2016-08-01|26020"}}],"coverage":{"historyRecords":3,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":575,"firstDate":"2008-12-15","lastDate":"2026-09-25","metrics":{"daysLost":15951,"injuries":500,"fatalities":5,"recentRows":145,"restrictedDays":1438,"contractorRecords":80},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"43902","DOCUMENT_NO":"220262710014","ACCIDENT_DT":"09/25/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Safety director","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was moving the Brookville tractor driving too close to the rib in slope run around when a rib strap hooked on the canopy post causing stored energy hitting employee in the right ear. Employee received 10 stitches and a full work release.","sourceDate":"2026-09-25"},{"SOURCE_ROW_NUMBER":"203036","DOCUMENT_NO":"220262650019","ACCIDENT_DT":"09/15/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","NARRATIVE":"I.E. stated they were helping move longwall power, 1 of the power cables wrapped around their right foot. When the cable was pulled it twisted their right knee, I.E. went to the V.A. hospital x-ray and CT scan did not show anything. Employee has been taken off work to follow up with Ortho.","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"39648","DOCUMENT_NO":"220262730011","ACCIDENT_DT":"09/10/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"IE was trying to get back into a mantrip when the driver drove off causing IE to give chase. As the IE grabbed onto the mantrip, EE's left foot got caught under the tire, causing the mantrip to drive over EE's left leg.","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"65328","DOCUMENT_NO":"220262450024","ACCIDENT_DT":"08/31/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Miner, Prospector, NEC","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The IE was removing a 10-inch valve in the RO Plant and had removed several bolts. When the IE removed the 2nd to last bolt, the valve swiveled and pinched the IE's ring finger between the collar of the valve and the pipe","sourceDate":"2026-08-31"},{"SOURCE_ROW_NUMBER":"220346","DOCUMENT_NO":"220261890011","ACCIDENT_DT":"07/01/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Contact with electrical current","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"I.E. stated EE was hanging shuttle car cable; the cable had a pin hole in the jacket allowing the employee to receive an electrical shock. Employee went to E.R. and received first aid treatment with full release.","sourceDate":"2026-07-01"},{"SOURCE_ROW_NUMBER":"181592","DOCUMENT_NO":"220261810017","ACCIDENT_DT":"06/24/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HOISTING","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"I.E. stated they were riding cage down and a foreign object flew in their eye behind their glasses.","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"99698","DOCUMENT_NO":"220262470031","ACCIDENT_DT":"06/23/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between running or meshing objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"I.E. stated they were helping work on a roof bolter, when power was set up and the pump motor started the cable reel was on and the cable swept their feet out from under them causing them to land on their right shoulder. Employee has worked since and went off for surgery on their right shoulder on 9/1/2026.","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"9553","DOCUMENT_NO":"220261660024","ACCIDENT_DT":"06/10/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"INUNDATION","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Longwall panel 12.2 had a gas inundation from behind the shields in the gob @ midface. When MSHA and mine reps. arrived on face the gas had already bled off.","sourceDate":"2026-06-10"},{"SOURCE_ROW_NUMBER":"48210","DOCUMENT_NO":"220261400015","ACCIDENT_DT":"05/18/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"50","NARRATIVE":"I.E. Stated EE was helping put up a waffle beam across the road when the helper lost grip of the beam dropping it smashing two fingers on left hand between beam and tractor. X-Ray showed 2 broken fingers and EE received 18 stitches.","sourceDate":"2026-05-18"},{"SOURCE_ROW_NUMBER":"129713","DOCUMENT_NO":"220261240024","ACCIDENT_DT":"05/02/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"I.E. was standing on the longwall pan line when 1 of the recovery bolters turn on EE's cable reel causing the bolter cable to hit Employee in EE's lower legs causing EE to fall hitting EE's left arm on the pan line. Employee had 8 stitches in EE's left arm.","sourceDate":"2026-05-02"},{"SOURCE_ROW_NUMBER":"177329","DOCUMENT_NO":"220261260003","ACCIDENT_DT":"04/29/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"EXPLODING VESSELS UNDER PRESSURE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","NARRATIVE":"IE stated that when disconnecting a hose from an air compressor, the fitting and whip check blew out the end of the hose striking the IE on the lower leg","sourceDate":"2026-04-29"},{"SOURCE_ROW_NUMBER":"48205","DOCUMENT_NO":"220261180015","ACCIDENT_DT":"04/26/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"The IE was carrying a bottle of compressed gas down the longwall face when EE slipped and fell. The IE has pain in the middle part of EE's back.","sourceDate":"2026-04-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2022-01-11","lastDate":"2022-01-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":5695,"firstDate":"2008-11-04","lastDate":"2026-09-03","metrics":{"ss":1256,"delinquent":5359,"recentRows":1577,"paidPenalty":4384774.09,"proposedPenalty":8100184,"currentAssessment":6201564.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2978303","VIOLATION_NO":"5017120","ISSUE_DT":"09/03/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"4383.00","CURRENT_ASSESSMENT_AMT":"4383.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"2978302","VIOLATION_NO":"5017119","ISSUE_DT":"09/01/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2312.00","CURRENT_ASSESSMENT_AMT":"2312.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"2978301","VIOLATION_NO":"5017118","ISSUE_DT":"09/01/2026","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"6037.00","CURRENT_ASSESSMENT_AMT":"6037.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"2978285","VIOLATION_NO":"5016444","ISSUE_DT":"09/01/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"398.00","CURRENT_ASSESSMENT_AMT":"398.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"2978284","VIOLATION_NO":"5016443","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.1107-16-b","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"2978264","VIOLATION_NO":"5011271","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.364(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"2978267","VIOLATION_NO":"5012478","ISSUE_DT":"08/26/2026","CFR_STANDARD_CD":"77.205(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"2978266","VIOLATION_NO":"5012477","ISSUE_DT":"08/26/2026","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"2978265","VIOLATION_NO":"5012476","ISSUE_DT":"08/26/2026","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"2937225","VIOLATION_NO":"5016442","ISSUE_DT":"08/26/2026","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"165.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"2978300","VIOLATION_NO":"5017117","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"2978283","VIOLATION_NO":"5016441","ISSUE_DT":"08/24/2026","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-24"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1395,"firstDate":"2010-11-17","lastDate":"2026-09-02","metrics":{"appeals":2,"decisions":1320,"recentRows":186,"decisionPenalty":2811207.8,"originalPenalty":5045691},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"466063","VIOLATION_NO":"5012035","DOCKET_NO":"LAKE 2026-0059","DECISION_DT":"09/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"959.00","DECISION_PENALTY_AMT":"767.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"465661","VIOLATION_NO":"9789499","DOCKET_NO":"LAKE 2026-0059","DECISION_DT":"09/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"959.00","DECISION_PENALTY_AMT":"767.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"465660","VIOLATION_NO":"9786584","DOCKET_NO":"LAKE 2026-0059","DECISION_DT":"09/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"1706.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"225053","VIOLATION_NO":"9789500","DOCKET_NO":"LAKE 2026-0059","DECISION_DT":"09/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"959.00","DECISION_PENALTY_AMT":"767.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"224955","VIOLATION_NO":"9789328","DOCKET_NO":"LAKE 2026-0059","DECISION_DT":"09/02/2026","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"3184.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"224028","VIOLATION_NO":"5016101","DOCKET_NO":"LAKE 2026-0059","DECISION_DT":"09/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"959.00","DECISION_PENALTY_AMT":"767.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"213888","VIOLATION_NO":"9549058","DOCKET_NO":"LAKE 2024-0146","DECISION_DT":"07/09/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"88354.00","DECISION_PENALTY_AMT":"20000.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"213887","VIOLATION_NO":"9549057","DOCKET_NO":"LAKE 2024-0146","DECISION_DT":"07/09/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"88354.00","DECISION_PENALTY_AMT":"25000.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"464715","VIOLATION_NO":"9789467","DOCKET_NO":"LAKE 2026-0002","DECISION_DT":"06/10/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1968.00","DECISION_PENALTY_AMT":"399.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-10"},{"SOURCE_ROW_NUMBER":"223882","VIOLATION_NO":"9789468","DOCKET_NO":"LAKE 2026-0002","DECISION_DT":"06/10/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"959.00","DECISION_PENALTY_AMT":"959.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-10"},{"SOURCE_ROW_NUMBER":"222615","VIOLATION_NO":"9786772","DOCKET_NO":"LAKE 2026-0002","DECISION_DT":"06/10/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3184.00","DECISION_PENALTY_AMT":"1431.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-10"},{"SOURCE_ROW_NUMBER":"465292","VIOLATION_NO":"9789495","DOCKET_NO":"LAKE 2026-0013","DECISION_DT":"05/05/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1037.00","DECISION_PENALTY_AMT":"830.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-05-05"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":16406,"firstDate":"2010-06-03","lastDate":"2026-10-14","metrics":{"recentRows":5660,"cpdmSamples":12352,"voidSamples":4205,"validSamples":12201,"maxConcentration":865.581,"concentrationTotal":11341.879},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2775873","SMP_TAKEN_DT":"10/14/2026","CONC":"1.175","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2434517","SMP_TAKEN_DT":"10/14/2026","CONC":".694","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2349066","SMP_TAKEN_DT":"10/14/2026","CONC":".91","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2177470","SMP_TAKEN_DT":"10/14/2026","CONC":"1.003","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2092892","SMP_TAKEN_DT":"10/14/2026","CONC":".552","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"1837182","SMP_TAKEN_DT":"10/14/2026","CONC":".577","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2605903","SMP_TAKEN_DT":"10/13/2026","CONC":"1.096","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2519355","SMP_TAKEN_DT":"10/13/2026","CONC":".314","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2263282","SMP_TAKEN_DT":"10/13/2026","CONC":".4","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2263279","SMP_TAKEN_DT":"10/13/2026","CONC":".646","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2006597","SMP_TAKEN_DT":"10/13/2026","CONC":".71","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"1922417","SMP_TAKEN_DT":"10/13/2026","CONC":"1.101","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":196,"firstDate":"2011-07-11","lastDate":"2026-09-22","metrics":{"linkedIssuances":196},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1404,"firstDate":"2008-11-04","lastDate":"2026-07-02","metrics":{"decisions":1329,"ssChanged":278,"recentRows":236,"decisionPenalty":2811207.8,"proposedPenalty":6517936},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"55205","CITATION_NO":"5012104","CITATION_ISSUE_DT":"07/02/2026","DOCKET_NO":"LAKE 2026-0204","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1431.00","sourceDate":"2026-07-02"},{"SOURCE_ROW_NUMBER":"55845","CITATION_NO":"5011127","CITATION_ISSUE_DT":"06/10/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.1714-7(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"193.00","sourceDate":"2026-06-10"},{"SOURCE_ROW_NUMBER":"451936","CITATION_NO":"5016176","CITATION_ISSUE_DT":"05/28/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"313.00","sourceDate":"2026-05-28"},{"SOURCE_ROW_NUMBER":"338215","CITATION_NO":"9789711","CITATION_ISSUE_DT":"05/28/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"193.00","sourceDate":"2026-05-28"},{"SOURCE_ROW_NUMBER":"111539","CITATION_NO":"9789991","CITATION_ISSUE_DT":"05/26/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3184.00","sourceDate":"2026-05-26"},{"SOURCE_ROW_NUMBER":"55209","CITATION_NO":"9789992","CITATION_ISSUE_DT":"05/26/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3184.00","sourceDate":"2026-05-26"},{"SOURCE_ROW_NUMBER":"225009","CITATION_NO":"9788610","CITATION_ISSUE_DT":"05/20/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.1714-3(b)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"12403.00","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"224218","CITATION_NO":"9788609","CITATION_ISSUE_DT":"05/20/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.1714(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"12403.00","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"112233","CITATION_NO":"9789707","CITATION_ISSUE_DT":"05/19/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"267.00","sourceDate":"2026-05-19"},{"SOURCE_ROW_NUMBER":"112197","CITATION_NO":"9789988","CITATION_ISSUE_DT":"05/19/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"336.00","sourceDate":"2026-05-19"},{"SOURCE_ROW_NUMBER":"281379","CITATION_NO":"5016164","CITATION_ISSUE_DT":"05/18/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.380(d)(7)(i)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"288.00","sourceDate":"2026-05-18"},{"SOURCE_ROW_NUMBER":"168378","CITATION_NO":"5016165","CITATION_ISSUE_DT":"05/18/2026","DOCKET_NO":"LAKE 2026-0190","CFR_STANDARD_CODE":"75.333(h)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"313.00","sourceDate":"2026-05-18"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":6520,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":35,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":1466,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":35,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2008-03-26","lastDate":"2008-03-26","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":1669,"firstDate":"2008-11-04","lastDate":"2026-10-15","metrics":{"inspectors":2808,"recentRows":515,"onSiteHours":56029.75,"inspectionHours":91771.25,"inspectionSamples":4738},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"126848","EVENT_NO":"F00C544","INSPECTION_BEGIN_DT":"10/15/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-10-15"},{"SOURCE_ROW_NUMBER":"11769","EVENT_NO":"F00C543","INSPECTION_BEGIN_DT":"10/13/2026","INSPECTION_END_DT":"10/13/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"1100228","EVENT_NO":"F00C542","INSPECTION_BEGIN_DT":"10/06/2026","INSPECTION_END_DT":"10/06/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"215126","EVENT_NO":"F01F3D3","INSPECTION_BEGIN_DT":"10/05/2026","ACTIVITY_CODE":"E07","ACTIVITY":"Non-Fatal Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"895795","EVENT_NO":"F00C541","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"103","SUM_TOTAL_ON_SITE_HOURS":"68.25","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"693351","EVENT_NO":"F016B0E","INSPECTION_BEGIN_DT":"09/30/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"308550","EVENT_NO":"F02C079","INSPECTION_BEGIN_DT":"09/28/2026","INSPECTION_END_DT":"09/28/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"840056","EVENT_NO":"F00C1C4","INSPECTION_BEGIN_DT":"09/22/2026","INSPECTION_END_DT":"09/22/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"165363","EVENT_NO":"F013327","INSPECTION_BEGIN_DT":"09/17/2026","INSPECTION_END_DT":"09/17/2026","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"494363","EVENT_NO":"F00C1C3","INSPECTION_BEGIN_DT":"09/14/2026","INSPECTION_END_DT":"09/14/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.25","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"194421","EVENT_NO":"F00C1C2","INSPECTION_BEGIN_DT":"09/10/2026","INSPECTION_END_DT":"09/10/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.25","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"757966","EVENT_NO":"F016B0D","INSPECTION_BEGIN_DT":"09/08/2026","INSPECTION_END_DT":"09/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-09-08"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":69,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":1105423,"employees":428,"production":12812197},"2018":{"hours":1162078,"employees":444,"production":14460951},"2019":{"hours":1079931,"employees":457,"production":12793896},"2020":{"hours":766004,"employees":356,"production":7196444},"2021":{"hours":738790,"employees":327,"production":7860150},"2022":{"hours":624133,"employees":271,"production":6378465},"2023":{"hours":749986,"employees":317,"production":5791526},"2024":{"hours":636906,"employees":276,"production":6216015},"2025":{"hours":585549,"employees":289,"production":5382718},"2026":{"hours":261584,"employees":283,"production":3334082}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":749,"firstDate":"2010-08-10","lastDate":"2026-10-01","metrics":{"recentRows":220,"doseOver100":148,"actDoseTotal":54122,"pelDoseTotal":38412},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"25848","EVENT_NO":"F00C541","SURVEY_DATE":"10/01/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"44","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"25847","EVENT_NO":"F00C541","SURVEY_DATE":"10/01/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"69","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"25846","EVENT_NO":"F00C541","SURVEY_DATE":"10/01/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"15","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"25845","EVENT_NO":"F00C541","SURVEY_DATE":"10/01/2026","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"8","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"25844","EVENT_NO":"F00C541","SURVEY_DATE":"10/01/2026","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"25843","EVENT_NO":"F00C541","SURVEY_DATE":"10/01/2026","OCCUPATION_CD_DESC":"CAR TRIMMER/CAR LOADER","MACHINE_CD":"40","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"25842","EVENT_NO":"F00C541","SURVEY_DATE":"10/01/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"56","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"25744","EVENT_NO":"7023446","SURVEY_DATE":"06/16/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"37","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2026-06-16"},{"SOURCE_ROW_NUMBER":"25743","EVENT_NO":"7023446","SURVEY_DATE":"06/16/2026","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"38","ACT_DOSE_85":"13","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2026-06-16"},{"SOURCE_ROW_NUMBER":"25742","EVENT_NO":"7023446","SURVEY_DATE":"06/16/2026","OCCUPATION_CD_DESC":"WATER TRUCK OPERATOR","MACHINE_CD":"39","ACT_DOSE_85":"6","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-06-16"},{"SOURCE_ROW_NUMBER":"25741","EVENT_NO":"7023446","SURVEY_DATE":"06/16/2026","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"38","ACT_DOSE_85":"4","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-06-16"},{"SOURCE_ROW_NUMBER":"25740","EVENT_NO":"7023446","SURVEY_DATE":"06/16/2026","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"38","ACT_DOSE_85":"10","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-06-16"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":945,"firstDate":"2010-06-24","lastDate":"2026-10-06","metrics":{"recentRows":353,"voidSamples":100,"maxQuartzPct":22.5,"validSamples":845,"quartzPctTotal":3546.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"93005","CASSETTE_NO":"58591369","SAMPLE_DT":"10/06/2026","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"HEADGATE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"64138","CASSETTE_NO":"58591288","SAMPLE_DT":"10/06/2026","QUARTZ_PCT":"04.9","QUARTZ_MICROGRAMS":"60","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"29594","CASSETTE_NO":"58591034","SAMPLE_DT":"10/06/2026","QUARTZ_PCT":"05.1","QUARTZ_MICROGRAMS":"56","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"1084","CASSETTE_NO":"58591294","SAMPLE_DT":"10/06/2026","QUARTZ_PCT":"04.5","QUARTZ_MICROGRAMS":"32","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"137544","CASSETTE_NO":"58591063","SAMPLE_DT":"10/01/2026","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"160888","CASSETTE_NO":"58591059","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"111068","CASSETTE_NO":"58591054","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"03.3","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"108951","CASSETTE_NO":"58591185","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"99008","CASSETTE_NO":"58591152","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"00.5","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"HEADGATE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"62229","CASSETTE_NO":"58591146","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"02.4","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"102399","CASSETTE_NO":"58591265","SAMPLE_DT":"07/09/2026","QUARTZ_PCT":"05.7","QUARTZ_MICROGRAMS":"31","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"101448","CASSETTE_NO":"58591324","SAMPLE_DT":"07/09/2026","QUARTZ_PCT":"05.6","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-09"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":5873,"firstDate":"2008-11-04","lastDate":"2026-10-15","metrics":{"ss":1265,"amountDue":6201564.8,"contested":14,"amountPaid":4384774.09,"recentRows":1638,"section104d":74,"unterminated":10,"proposedPenalty":8100184},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"554042","VIOLATION_NO":"9789764","VIOLATION_ISSUE_DT":"10/15/2026","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-15"},{"SOURCE_ROW_NUMBER":"553682","VIOLATION_NO":"5016653","VIOLATION_ISSUE_DT":"10/15/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-15"},{"SOURCE_ROW_NUMBER":"553681","VIOLATION_NO":"5016652","VIOLATION_ISSUE_DT":"10/15/2026","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-15"},{"SOURCE_ROW_NUMBER":"553692","VIOLATION_NO":"5017226","VIOLATION_ISSUE_DT":"10/14/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"553691","VIOLATION_NO":"5017225","VIOLATION_ISSUE_DT":"10/14/2026","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/14/2026","CONTESTED_IND":"N","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"553675","VIOLATION_NO":"5011278","VIOLATION_ISSUE_DT":"10/14/2026","SIG_SUB":"Y","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/14/2026","CONTESTED_IND":"N","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"554026","VIOLATION_NO":"9789763","VIOLATION_ISSUE_DT":"10/13/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"554025","VIOLATION_NO":"9789762","VIOLATION_ISSUE_DT":"10/13/2026","SIG_SUB":"N","PART_SECTION":"75.1914(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/15/2026","CONTESTED_IND":"N","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"553680","VIOLATION_NO":"5016651","VIOLATION_ISSUE_DT":"10/13/2026","SIG_SUB":"N","PART_SECTION":"75.1714-6","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"553679","VIOLATION_NO":"5016650","VIOLATION_ISSUE_DT":"10/13/2026","SIG_SUB":"N","PART_SECTION":"75.1909(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"553678","VIOLATION_NO":"5016649","VIOLATION_ISSUE_DT":"10/13/2026","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/14/2026","CONTESTED_IND":"N","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"553687","VIOLATION_NO":"5017134","VIOLATION_ISSUE_DT":"10/09/2026","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/09/2026","CONTESTED_IND":"N","sourceDate":"2026-10-09"}]}],"safety":{"href":"/api/v1/mines/1103189/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1103189/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":276,"companyType":"Independent Producer Operator","components":[{"averageEmployees":276,"laborHours":636906,"mineType":"Underground","productionTons":6216015}],"county":"Franklin","laborHours":636906,"mineName":"Mc#1 Mine","mineType":"Underground","mshaId":"1103189","operatingAddress":"11351 N. Thompsonville Rd., Macedonia, IL 62860","operatingCompany":"M-Class Mining Llc","operationType":"Mine and Preparation Plant","productionTons":6216015,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Illinois","status":"Active","supplyRegion":"Illinois Basin","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1914","heading":"Maintenance of diesel-powered equipment.","id":"75.1914","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1914","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Diesel-powered equipment shall be maintained in approved and safe condition or removed from service.\n\n(b) Maintenance and repairs of approved features and those features required by §§ 75.1909 and 75.1910 on diesel-powered equipment shall be made only by a person qualified under § 75.1915.\n\n(c) The water scrubber system on diesel-powered equipment shall be drained and flushed, by a person who is trained to perform this task, at least once on each shift in which the equipment is operated.\n\n(d) The intake air filter on diesel-powered equipment shall be replaced or serviced, by a person who is trained to perform this task, when the intake air pressure drop device so indicates or when the engine manufacturer's maximum allowable air pressure drop level is exceeded.\n\n(e) Mobile diesel-powered equipment that is to be used during a shift shall be visually examined by the equipment operator before being placed in operation. Equipment defects affecting safety shall be reported promptly to the mine operator.\n\n(f) All diesel-powered equipment shall be examined and tested weekly by a person qualified under § 75.1915.\n\n(1) Examinations and tests shall be conducted in accordance with approved checklists and manufacturers' maintenance manuals.\n\n(2) Persons performing weekly examinations and tests of diesel-powered equipment under this paragraph shall make a record when the equipment is not in approved or safe condition. The record shall include the equipment that is not in approved or safe condition, the defect found, and the corrective action taken.\n\n(g) Undiluted exhaust emissions of diesel engines in diesel-powered equipment approved under part 36 and heavy-duty nonpermissible diesel-powered equipment as defined in § 75.1908(a) in use in underground coal mines shall be tested and evaluated weekly by a person who is trained to perform this task. The mine operator shall develop and implement written standard operating procedures for such testing and evaluation that specify the following:\n\n(1) The method of achieving a repeatable loaded engine operating condition for each type of equipment;\n\n(2) Sampling and analytical methods (including calibration of instrumentation) that are capable of accurately detecting carbon monoxide in the expected concentrations;\n\n(3) The method of evaluation and interpretation of the results;\n\n(4) The concentration or changes in concentration of carbon monoxide that will indicate a change in engine performance. Carbon monoxide concentration shall not exceed 2500 parts per million; and\n\n(5) The maintenance of records necessary to track engine performance.\n\n(h) Recordkeeping. Records required by paragraphs (f)(2) and (g)(5) shall be—\n\n(1) Recorded in a secure book that is not susceptible to alteration, or recorded electronically in a computer system that is secure and not susceptible to alteration; and\n\n(2) Retained at a surface location at the mine for at least 1 year and made available for inspection by an authorized representative of the Secretary and by miners' representatives.\n\n(i) Diesel-powered equipment must be maintained in accordance with this part as of November 25, 1997.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1714-6","heading":"Emergency tethers.","id":"75.1714-6","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-6","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"At least one tether, which is a durable rope or equivalent material designed to permit members of a mine crew to link together while evacuating the mine during an emergency, shall be provided and stored with the additional SCSRs on the fixed work location and on the mobile equipment required in §§ 75.1714-4(a)(1) and (b) of this part.\n\n[71 FR 71454, Dec. 8, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1909","heading":"Nonpermissible diesel-powered equipment; design and performance requirements.","id":"75.1909","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1909","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Nonpermissible diesel-powered equipment, except for the special category of equipment under § 75.1908(d), must be equipped with the following features:\n\n(1) An engine approved under subpart E of part 7 of this title equipped with an air filter sized in accordance with the engine manufacturer's recommendations, and an air filter service indicator set in accordance with the engine manufacturer's recommendations;\n\n(2) At least one portable multipurpose dry chemical type (ABC) fire extinguisher listed or approved by a nationally recognized independent testing laboratory with a 10A:60B:C or higher rating. The fire extinguisher must be located within easy reach of the equipment operator and protected from damage;\n\n(3) A fuel system specifically designed for diesel fuel meeting the following requirements:\n\n(i) A fuel tank and fuel lines that do not leak;\n\n(ii) A fuel tank that is substantially constructed and protected against damage by collision;\n\n(iii) A vent opening that maintains atmospheric pressure in the fuel tank, and that is designed to prevent fuel from splashing out of the vent opening;\n\n(iv) A self-closing filler cap on the fuel tank;\n\n(v) The fuel tank, filler and vent must be located so that leaks or spillage during refueling will not contact hot surfaces;\n\n(vi) Fuel line piping must be either steel-wire reinforced; synthetic elastomer-covered hose suitable for use with diesel fuel that has been tested and has been determined to be fire-resistant by the manufacturer; or metal;\n\n(vii) Fuel line piping must be clamped;\n\n(viii) Primary fuel lines must be located so that fuel line leaks do not contact hot surfaces;\n\n(ix) The fuel lines must be separated from electrical wiring and protected from damage in ordinary use;\n\n(x) A manual shutoff valve must be installed in the fuel system as close as practicable to the tank; and\n\n(xi) A water separator and fuel filter(s) must be provided.\n\n(4) A sensor to monitor the temperature and provide a visual warning of an overheated cylinder head on air-cooled engines;\n\n(5) Guarding to protect fuel, hydraulic, and electric lines when such lines pass near rotating parts or in the event of shaft failure;\n\n(6) Hydraulic tanks, fillers, vents, and lines located to prevent spillage or leaks from contacting hot surfaces;\n\n(7) Reflectors or warning lights mounted on the equipment which can be readily seen in all directions;\n\n(8) A means to direct exhaust gas away from the equipment operator, persons on board the machine, and combustible machine components;\n\n(9) A means to prevent unintentional free and uncontrolled descent of personnel-elevating work platforms; and\n\n(10) A means to prevent the spray from ruptured hydraulic or lubricating oil lines from being ignited by contact with engine exhaust system component surfaces.\n\n(b) Self-propelled nonpermissible diesel-powered equipment must have the following features in addition to those in paragraph (a):\n\n(1) A means to ensure that no stored hydraulic energy that will cause machine articulation is available after the engine is shut down;\n\n(2) A neutral start feature which ensures that engine cranking torque will not be transmitted through the powertrain and cause machine movement on vehicles utilizing fluid power transmissions;\n\n(3) For machines with steering wheels, brake pedals, and accelerator pedals, controls which are of automobile orientation;\n\n(4) An audible warning device conveniently located near the equipment operator;\n\n(5) Lights provided and maintained on both ends of the equipment. Equipment normally operated in both directions must be equipped with headlights for both directions;\n\n(6) Service brakes that act on each wheel of the vehicle and that are designed such that failure of any single component, except the brake actuation pedal or other similar actuation device, must not result in a complete loss of service braking capability;\n\n(7) Service brakes that safely bring the fully loaded vehicle to a complete stop on the maximum grade on which it is operated; and\n\n(8) No device that traps a column of fluid to hold the brake in the applied position shall be installed in any brake system, unless the trapped column of fluid is released when the equipment operator is no longer in contact with the brake activation device.\n\n(c) Self-propelled nonpermissible heavy-duty diesel-powered equipment under § 75.1908(a), except rail-mounted equipment, shall be provided with a supplemental braking system that:\n\n(1) Engages automatically within 5 seconds of the shutdown of the engine;\n\n(2) Safely brings the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(3) Holds the equipment stationary, despite any contraction of brake parts, exhaustion of any nonmechanical source of energy, or leakage;\n\n(4) Releases only by a manual control that does not operate any other equipment function;\n\n(5) Has a means in the equipment operator's compartment to apply the brakes manually without shutting down the engine, and a means to release and reengage the brakes without the engine operating; and\n\n(6) Has a means to ensure that the supplemental braking system is released before the equipment can be trammed, and is designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(d) Self-propelled nonpermissible light-duty diesel-powered equipment under § 75.1908(b), except rail-mounted equipment, must be provided with a parking brake that holds the fully loaded equipment stationary on the maximum grade on which it is operated despite any contraction of the brake parts, exhaustion of any nonmechanical source of energy, or leakage.\n\n(e) The supplemental and park brake systems required by paragraphs (c) and (d) must be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n(f) Self-propelled personnel-elevating work platforms must be provided with a means to ensure that the parking braking system is released before the equipment can be trammed, and must be designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(g) Any nonpermissible equipment that discharges its exhaust directly into a return air course must be provided with a power package approved under subpart F of part 7 of this title.\n\n(h) Self-propelled nonpermissible heavy-duty diesel-powered equipment meeting the requirements of § 75.1908(a) must be provided with an automatic fire suppression system meeting the requirements of § 75.1911.\n\n(i) Self-propelled nonpermissible light-duty diesel-powered equipment meeting the requirements of § 75.1908(b) must be provided with an automatic or manual fire suppression system meeting the requirements of § 75.1911.\n\n(j) Nonpermissible equipment that is not self-propelled must have the following features in addition to those listed in paragraph (a):\n\n(1) A means to prevent inadvertent movement of the equipment when parked;\n\n(2) Safety chains or other suitable secondary connections on equipment that is being towed; and\n\n(3) An automatic fire suppression system meeting the requirements of § 75.1911.\n\n[61 FR 55527, Oct. 25, 1996; 62 FR 34641, June 27, 1997]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1103189","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}