{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"1103156","name":"Wildcat Hills Mine-Underground","status":"Abandoned and Sealed","status_date":"2020-11-18","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IL","county":"Saline","nearest_town":"Eldorado","operator_id":"P23854","operator_name":"Peabody Midwest Mining, LLC","controller_id":"C15833","controller_name":"Peabody Energy Corporation","district":"C10","office":"Madisonville KY Field Office","employees":0,"latitude":37.773889,"longitude":-88.389167},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":22805},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1103156","name":"Wildcat Hills Mine-Underground"},"operator":{"type":"operator","id":"P23854","name":"Peabody Midwest Mining, LLC"},"controller":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"1103156","name":"Wildcat Hills Mine-Underground"},"validFrom":"1997-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1103156|C15833|1997-11-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23854","name":"Peabody Midwest Mining, LLC"},"object":{"type":"mine","id":"1103156","name":"Wildcat Hills Mine-Underground"},"validFrom":"2005-11-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1103156|P23854|2005-11-22|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P23854","name":"Peabody Midwest Mining, LLC"},"validFrom":"2005-11-22","validTo":null,"current":true,"derived":true,"evidenceMineId":"1103156","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1103156|P23854|2005-11-22|C15833|1997-11-01|96913"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":237,"firstDate":"2006-07-10","lastDate":"2020-01-10","metrics":{"daysLost":9330,"injuries":168,"fatalities":1,"recentRows":0,"restrictedDays":734,"contractorRecords":9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"237543","DOCUMENT_NO":"220200140006","ACCIDENT_DT":"01/10/2020","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"IE was packing 60\" top belt rollers to supply trailer when IE tripped over a stick of 6\" waterline. IE fell into the supply trailer striking IE's left knee and thigh. IE received a 1\" laceration on IE's inner left thigh, which required 6 sutures to close the laceration.","sourceDate":"2020-01-10"},{"SOURCE_ROW_NUMBER":"203018","DOCUMENT_NO":"220193380021","ACCIDENT_DT":"11/25/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"9","NARRATIVE":"Employee was hanging curtain when a rock fell out between rows of bolts and struck employee in the head and shin.","sourceDate":"2019-11-25"},{"SOURCE_ROW_NUMBER":"168664","DOCUMENT_NO":"220193310018","ACCIDENT_DT":"11/19/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"Employee was throwing cable over and when the employee raised back to the standing position hit head on a brow.","sourceDate":"2019-11-19"},{"SOURCE_ROW_NUMBER":"220336","DOCUMENT_NO":"220193290001","ACCIDENT_DT":"11/06/2019","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"19","NARRATIVE":"EE complained of pain on 11/6/19. Evaluated and diagnosed with partial AC separation on 11/14/19 due to repetitive trauma. EE returned to work on 11/11/2019 with no restrictions and was to work as tolerated. 11/14/19 EE given temporary restrictions and taken off work. Follow up on 11/27/19. ***Narrative summarized from 7 supporting pages***","sourceDate":"2019-11-06"},{"SOURCE_ROW_NUMBER":"91115","DOCUMENT_NO":"220193160011","ACCIDENT_DT":"11/01/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Employee was placing hog panel on the ATRS when EE over extended EE's back muscles","sourceDate":"2019-11-01"},{"SOURCE_ROW_NUMBER":"116907","DOCUMENT_NO":"220192940028","ACCIDENT_DT":"10/16/2019","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"24","NARRATIVE":"Injured employee was operating a continuous miner when a 15\"x10\"x4\" piece of cap rock fell out striking the right foot just behind the steel toe causing a fracture to the pinky toe.","sourceDate":"2019-10-16"},{"SOURCE_ROW_NUMBER":"95388","DOCUMENT_NO":"220193440008","ACCIDENT_DT":"10/10/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"On 11/8/2019 an accident report was filled out stating the IE shoulder has been hurting for the past month. After work comp/doctor visits. The IE believes the incident resulted from hanging a cable on 10/10/2019. It wasn't until 12/09/2019 the worker was taken off work pending an mri.","sourceDate":"2019-10-10"},{"SOURCE_ROW_NUMBER":"198675","DOCUMENT_NO":"220193080007","ACCIDENT_DT":"09/24/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was hanging cable in entry 5 @ 27+50 EE felt burning and a small pop in right shoulder.","sourceDate":"2019-09-24"},{"SOURCE_ROW_NUMBER":"194372","DOCUMENT_NO":"220192900003","ACCIDENT_DT":"09/20/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was in the process of moving the continuous miner cable off of a getman and lost balance causing them to fall into the canopy of the getman.","sourceDate":"2019-09-20"},{"SOURCE_ROW_NUMBER":"121221","DOCUMENT_NO":"220192620017","ACCIDENT_DT":"09/11/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"Employee was reclaiming belt structure and was stacking belt rails on the back of a mini track. While attempting to place a rail the previously stacked rails moved and pinched the left pinky finger","sourceDate":"2019-09-11"},{"SOURCE_ROW_NUMBER":"86959","DOCUMENT_NO":"220192530017","ACCIDENT_DT":"08/29/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"IE was sealing a return stopping. IE had a bucket of sealant slip out of IE's hand and land on the mine floor. When the bucket hit the floor, a watery sealant mixture went into IE's eye.","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"254760","DOCUMENT_NO":"220192380034","ACCIDENT_DT":"08/21/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"48","NARRATIVE":"While driving a ram car on unit 1 the employee bumped their head against the canopy of a ram car. The IE stated that they drove through a hole which caused them to suddenly come up and in contact with the canopy.","sourceDate":"2019-08-21"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-11-18","lastDate":"2020-11-18","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":3274,"firstDate":"2006-03-27","lastDate":"2020-05-04","metrics":{"ss":536,"delinquent":2992,"recentRows":0,"paidPenalty":2415949.4,"proposedPenalty":2784596,"currentAssessment":2415949.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2046670","VIOLATION_NO":"9149127","ISSUE_DT":"05/04/2020","CFR_STANDARD_CD":"77.1607(n)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-05-04"},{"SOURCE_ROW_NUMBER":"2040978","VIOLATION_NO":"9149126","ISSUE_DT":"03/12/2020","CFR_STANDARD_CD":"75.507","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"185.00","CURRENT_ASSESSMENT_AMT":"185.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-12"},{"SOURCE_ROW_NUMBER":"2046669","VIOLATION_NO":"9149125","ISSUE_DT":"02/20/2020","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"5332.00","CURRENT_ASSESSMENT_AMT":"2268.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"2040509","VIOLATION_NO":"9261075","ISSUE_DT":"12/17/2019","CFR_STANDARD_CD":"75.1910(j)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-17"},{"SOURCE_ROW_NUMBER":"2040480","VIOLATION_NO":"9149124","ISSUE_DT":"12/17/2019","CFR_STANDARD_CD":"49.16(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-17"},{"SOURCE_ROW_NUMBER":"2040479","VIOLATION_NO":"9149123","ISSUE_DT":"12/17/2019","CFR_STANDARD_CD":"49.16","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-17"},{"SOURCE_ROW_NUMBER":"2040508","VIOLATION_NO":"9261074","ISSUE_DT":"12/16/2019","CFR_STANDARD_CD":"75.1914(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-16"},{"SOURCE_ROW_NUMBER":"2040478","VIOLATION_NO":"9149122","ISSUE_DT":"12/16/2019","CFR_STANDARD_CD":"75.380(d)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-16"},{"SOURCE_ROW_NUMBER":"2040481","VIOLATION_NO":"9149353","ISSUE_DT":"12/12/2019","CFR_STANDARD_CD":"75.1911(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-12"},{"SOURCE_ROW_NUMBER":"2040485","VIOLATION_NO":"9149438","ISSUE_DT":"12/11/2019","CFR_STANDARD_CD":"75.1501(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"482.00","CURRENT_ASSESSMENT_AMT":"482.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-11"},{"SOURCE_ROW_NUMBER":"2040507","VIOLATION_NO":"9261073","ISSUE_DT":"12/10/2019","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2040506","VIOLATION_NO":"9261072","ISSUE_DT":"12/10/2019","CFR_STANDARD_CD":"75.1107-13(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"157.00","CURRENT_ASSESSMENT_AMT":"157.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-10"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":181,"firstDate":"2009-01-22","lastDate":"2020-07-09","metrics":{"appeals":0,"decisions":181,"recentRows":0,"decisionPenalty":378730.4,"originalPenalty":773749},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"191767","VIOLATION_NO":"9149125","DOCKET_NO":"LAKE 2020-0161","DECISION_DT":"07/09/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5332.00","DECISION_PENALTY_AMT":"2268.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2020-07-09"},{"SOURCE_ROW_NUMBER":"431116","VIOLATION_NO":"9110121","DOCKET_NO":"LAKE 2020-0012","DECISION_DT":"01/27/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7214.00","DECISION_PENALTY_AMT":"3650.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2020-01-27"},{"SOURCE_ROW_NUMBER":"429183","VIOLATION_NO":"9110341","DOCKET_NO":"LAKE 2019-0318","DECISION_DT":"08/16/2019","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"902.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2019-08-16"},{"SOURCE_ROW_NUMBER":"186999","VIOLATION_NO":"9110718","DOCKET_NO":"LAKE 2019-0262","DECISION_DT":"07/10/2019","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4121.00","DECISION_PENALTY_AMT":"1242.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2019-07-10"},{"SOURCE_ROW_NUMBER":"407957","VIOLATION_NO":"9038387","DOCKET_NO":"LAKE 2017-0073","DECISION_DT":"07/05/2019","DECISION_TYPE_CODE_DESC":"Prevail","ORIGINAL_PENALTY_AMT":"918.00","DECISION_PENALTY_AMT":"213.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2019-07-05"},{"SOURCE_ROW_NUMBER":"407597","VIOLATION_NO":"9039355","DOCKET_NO":"LAKE 2017-0074","DECISION_DT":"07/05/2019","DECISION_TYPE_CODE_DESC":"Vacate","ORIGINAL_PENALTY_AMT":"3388.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2019-07-05"},{"SOURCE_ROW_NUMBER":"166723","VIOLATION_NO":"9039357","DOCKET_NO":"LAKE 2017-0073","DECISION_DT":"07/05/2019","DECISION_TYPE_CODE_DESC":"Vacate","ORIGINAL_PENALTY_AMT":"10124.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2019-07-05"},{"SOURCE_ROW_NUMBER":"166282","VIOLATION_NO":"9039356","DOCKET_NO":"LAKE 2017-0073","DECISION_DT":"07/05/2019","DECISION_TYPE_CODE_DESC":"Vacate","ORIGINAL_PENALTY_AMT":"10124.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2019-07-05"},{"SOURCE_ROW_NUMBER":"178039","VIOLATION_NO":"9105906","DOCKET_NO":"LAKE 2018-0253","DECISION_DT":"03/18/2019","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"12638.00","DECISION_PENALTY_AMT":"3244.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2019-03-18"},{"SOURCE_ROW_NUMBER":"421815","VIOLATION_NO":"9109187","DOCKET_NO":"LAKE 2018-0358","DECISION_DT":"11/16/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5111.00","DECISION_PENALTY_AMT":"1539.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2018-11-16"},{"SOURCE_ROW_NUMBER":"179336","VIOLATION_NO":"9109188","DOCKET_NO":"LAKE 2018-0358","DECISION_DT":"11/16/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4717.00","DECISION_PENALTY_AMT":"3774.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2018-11-16"},{"SOURCE_ROW_NUMBER":"416219","VIOLATION_NO":"9101055","DOCKET_NO":"LAKE 2018-0052","DECISION_DT":"10/01/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"160.00","DECISION_PENALTY_AMT":"116.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2018-10-01"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":11314,"firstDate":"2006-05-24","lastDate":"2019-12-06","metrics":{"recentRows":0,"cpdmSamples":7875,"voidSamples":2628,"validSamples":8686,"maxConcentration":670.63,"concentrationTotal":9841.372},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2382367","SMP_TAKEN_DT":"12/6/2019","CONC":".975","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-06"},{"SOURCE_ROW_NUMBER":"2125347","SMP_TAKEN_DT":"12/6/2019","CONC":"1.274","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-06"},{"SOURCE_ROW_NUMBER":"2895138","SMP_TAKEN_DT":"12/5/2019","CONC":"1.257","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-05"},{"SOURCE_ROW_NUMBER":"1784657","SMP_TAKEN_DT":"12/4/2019","CONC":"1.198","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-04"},{"SOURCE_ROW_NUMBER":"2809086","SMP_TAKEN_DT":"12/3/2019","CONC":"1.211","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-03"},{"SOURCE_ROW_NUMBER":"2723963","SMP_TAKEN_DT":"12/3/2019","CONC":".924","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-03"},{"SOURCE_ROW_NUMBER":"2723488","SMP_TAKEN_DT":"12/3/2019","CONC":".654","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-03"},{"SOURCE_ROW_NUMBER":"1869863","SMP_TAKEN_DT":"12/3/2019","CONC":".899","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-03"},{"SOURCE_ROW_NUMBER":"2979889","SMP_TAKEN_DT":"12/2/2019","CONC":".575","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"2894808","SMP_TAKEN_DT":"12/2/2019","CONC":"1.011","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"1954669","SMP_TAKEN_DT":"12/2/2019","CONC":".973","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"1300045","CASS_NUM":"58318930","SMP_TAKEN_DT":"12/2/2019","CONC":".931","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-12-02"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":61,"firstDate":"2006-05-17","lastDate":"2019-08-29","metrics":{"linkedIssuances":61},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":181,"firstDate":"2007-08-29","lastDate":"2020-02-20","metrics":{"decisions":181,"ssChanged":58,"recentRows":0,"decisionPenalty":378730.4,"proposedPenalty":773749},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"160513","CITATION_NO":"9149125","CITATION_ISSUE_DT":"02/20/2020","DOCKET_NO":"LAKE 2020-0161","DECISION_DT":"07/09/2020","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5332.00","DECISION_PENALTY_AMT":"2268.00","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"103142","CITATION_NO":"9110121","CITATION_ISSUE_DT":"08/06/2019","DOCKET_NO":"LAKE 2020-0012","DECISION_DT":"01/27/2020","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"7214.00","DECISION_PENALTY_AMT":"3650.00","sourceDate":"2019-08-06"},{"SOURCE_ROW_NUMBER":"329544","CITATION_NO":"9110341","CITATION_ISSUE_DT":"05/20/2019","DOCKET_NO":"LAKE 2019-0318","DECISION_DT":"08/16/2019","CFR_STANDARD_CODE":"75.1103-1","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"902.00","DECISION_PENALTY_AMT":".00","sourceDate":"2019-05-20"},{"SOURCE_ROW_NUMBER":"102685","CITATION_NO":"9110718","CITATION_ISSUE_DT":"03/07/2019","DOCKET_NO":"LAKE 2019-0262","DECISION_DT":"07/10/2019","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4121.00","DECISION_PENALTY_AMT":"1242.00","sourceDate":"2019-03-07"},{"SOURCE_ROW_NUMBER":"438202","CITATION_NO":"9109187","CITATION_ISSUE_DT":"06/20/2018","DOCKET_NO":"LAKE 2018-0358","DECISION_DT":"11/16/2018","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5111.00","DECISION_PENALTY_AMT":"1539.00","sourceDate":"2018-06-20"},{"SOURCE_ROW_NUMBER":"382742","CITATION_NO":"9109188","CITATION_ISSUE_DT":"06/20/2018","DOCKET_NO":"LAKE 2018-0358","DECISION_DT":"11/16/2018","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4717.00","DECISION_PENALTY_AMT":"3774.00","sourceDate":"2018-06-20"},{"SOURCE_ROW_NUMBER":"44555","CITATION_NO":"9109157","CITATION_ISSUE_DT":"05/16/2018","DOCKET_NO":"LAKE 2018-0314","DECISION_DT":"09/27/2018","CFR_STANDARD_CODE":"75.604(d)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"12321.00","DECISION_PENALTY_AMT":"10000.00","sourceDate":"2018-05-16"},{"SOURCE_ROW_NUMBER":"214840","CITATION_NO":"9109141","CITATION_ISSUE_DT":"05/03/2018","DOCKET_NO":"LAKE 2018-0315","DECISION_DT":"09/27/2018","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5536.00","DECISION_PENALTY_AMT":"4429.00","sourceDate":"2018-05-03"},{"SOURCE_ROW_NUMBER":"101544","CITATION_NO":"9109143","CITATION_ISSUE_DT":"05/03/2018","DOCKET_NO":"LAKE 2018-0315","DECISION_DT":"09/27/2018","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4019.00","DECISION_PENALTY_AMT":"1211.00","sourceDate":"2018-05-03"},{"SOURCE_ROW_NUMBER":"101543","CITATION_NO":"9109122","CITATION_ISSUE_DT":"04/11/2018","DOCKET_NO":"LAKE 2018-0290","DECISION_DT":"08/02/2018","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"12321.00","DECISION_PENALTY_AMT":"750.00","sourceDate":"2018-04-11"},{"SOURCE_ROW_NUMBER":"156295","CITATION_NO":"9105906","CITATION_ISSUE_DT":"01/09/2018","DOCKET_NO":"LAKE 2018-0253","DECISION_DT":"03/18/2019","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"12638.00","DECISION_PENALTY_AMT":"3244.00","sourceDate":"2018-01-09"},{"SOURCE_ROW_NUMBER":"439941","CITATION_NO":"9106281","CITATION_ISSUE_DT":"11/15/2017","DOCKET_NO":"LAKE 2018-0119","DECISION_DT":"08/09/2018","CFR_STANDARD_CODE":"75.362(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"9498.00","DECISION_PENALTY_AMT":"6649.00","sourceDate":"2017-11-15"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":2171,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":12,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":514,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":11,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2005-11-22","lastDate":"2005-11-22","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":591,"firstDate":"2006-02-22","lastDate":"2020-09-09","metrics":{"inspectors":1121,"recentRows":0,"onSiteHours":24959.25,"inspectionHours":41053.75,"inspectionSamples":4792},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"800620","EVENT_NO":"6485337","INSPECTION_BEGIN_DT":"09/09/2020","INSPECTION_END_DT":"12/08/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"29.5","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2020-09-09"},{"SOURCE_ROW_NUMBER":"538382","EVENT_NO":"6486957","INSPECTION_BEGIN_DT":"08/11/2020","INSPECTION_END_DT":"08/11/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2020-08-11"},{"SOURCE_ROW_NUMBER":"548961","EVENT_NO":"4489863","INSPECTION_BEGIN_DT":"06/08/2020","INSPECTION_END_DT":"06/08/2020","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2020-06-08"},{"SOURCE_ROW_NUMBER":"1131776","EVENT_NO":"4490969","INSPECTION_BEGIN_DT":"06/04/2020","INSPECTION_END_DT":"06/04/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2020-06-04"},{"SOURCE_ROW_NUMBER":"10141","EVENT_NO":"6485660","INSPECTION_BEGIN_DT":"06/02/2020","INSPECTION_END_DT":"06/02/2020","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2020-06-02"},{"SOURCE_ROW_NUMBER":"498612","EVENT_NO":"4489925","INSPECTION_BEGIN_DT":"05/19/2020","INSPECTION_END_DT":"05/19/2020","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2020-05-19"},{"SOURCE_ROW_NUMBER":"1058559","EVENT_NO":"6486211","INSPECTION_BEGIN_DT":"05/18/2020","INSPECTION_END_DT":"05/18/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"24.5","SUM_TOTAL_ON_SITE_HOURS":"14.5","sourceDate":"2020-05-18"},{"SOURCE_ROW_NUMBER":"783137","EVENT_NO":"4489993","INSPECTION_BEGIN_DT":"05/13/2020","INSPECTION_END_DT":"05/13/2020","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2020-05-13"},{"SOURCE_ROW_NUMBER":"873605","EVENT_NO":"6486953","INSPECTION_BEGIN_DT":"05/04/2020","INSPECTION_END_DT":"05/04/2020","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2020-05-04"},{"SOURCE_ROW_NUMBER":"790118","EVENT_NO":"6486951","INSPECTION_BEGIN_DT":"04/20/2020","INSPECTION_END_DT":"04/20/2020","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2020-04-20"},{"SOURCE_ROW_NUMBER":"80279","EVENT_NO":"6486950","INSPECTION_BEGIN_DT":"04/07/2020","INSPECTION_END_DT":"04/07/2020","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2020-04-07"},{"SOURCE_ROW_NUMBER":"570863","EVENT_NO":"6486949","INSPECTION_BEGIN_DT":"04/01/2020","INSPECTION_END_DT":"04/01/2020","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2020-04-01"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":42,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":365051,"employees":156,"production":1018246},"2012":{"hours":475845,"employees":210,"production":1457906},"2013":{"hours":552732,"employees":235,"production":1579031},"2014":{"hours":656806,"employees":281,"production":2018114},"2015":{"hours":511966,"employees":245,"production":2026081},"2016":{"hours":470838,"employees":221,"production":1544188},"2017":{"hours":557959,"employees":269,"production":1462854},"2018":{"hours":544564,"employees":242,"production":1330804},"2019":{"hours":504423,"employees":228,"production":1416697},"2020":{"hours":29997,"employees":55,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":450,"firstDate":"2006-08-29","lastDate":"2019-08-14","metrics":{"recentRows":0,"doseOver100":107,"actDoseTotal":33966,"pelDoseTotal":26509},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"24780","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"45","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24779","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"50","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24778","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"71","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24777","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"69","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24776","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"65","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24760","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"56","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24759","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"54","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24758","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"61","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24757","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"115","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24756","EVENT_NO":"7005402","SURVEY_DATE":"08/14/2019","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"62","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2019-08-14"},{"SOURCE_ROW_NUMBER":"24775","EVENT_NO":"7005402","SURVEY_DATE":"07/30/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"102","ACT_DOSE_85":"57","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2019-07-30"},{"SOURCE_ROW_NUMBER":"24774","EVENT_NO":"7005402","SURVEY_DATE":"07/30/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"102","ACT_DOSE_85":"78","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2019-07-30"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":455,"firstDate":"2006-05-24","lastDate":"2019-12-02","metrics":{"recentRows":0,"voidSamples":48,"maxQuartzPct":9.7,"validSamples":407,"quartzPctTotal":1347.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"107789","CASSETTE_NO":"58319004","SAMPLE_DT":"12/02/2019","QUARTZ_PCT":"03.6","QUARTZ_MICROGRAMS":"29","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"94256","CASSETTE_NO":"58319026","SAMPLE_DT":"12/02/2019","QUARTZ_PCT":"03.9","QUARTZ_MICROGRAMS":"31","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"73036","CASSETTE_NO":"58319025","SAMPLE_DT":"12/02/2019","QUARTZ_PCT":"03.7","QUARTZ_MICROGRAMS":"28","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"25210","CASSETTE_NO":"58318929","SAMPLE_DT":"12/02/2019","QUARTZ_PCT":"03.9","QUARTZ_MICROGRAMS":"37","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"98224","CASSETTE_NO":"58318884","SAMPLE_DT":"11/26/2019","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-26"},{"SOURCE_ROW_NUMBER":"60272","CASSETTE_NO":"58319015","SAMPLE_DT":"11/26/2019","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-26"},{"SOURCE_ROW_NUMBER":"43674","CASSETTE_NO":"58319019","SAMPLE_DT":"11/26/2019","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-26"},{"SOURCE_ROW_NUMBER":"35804","CASSETTE_NO":"58319024","SAMPLE_DT":"11/26/2019","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-26"},{"SOURCE_ROW_NUMBER":"128467","CASSETTE_NO":"58318899","SAMPLE_DT":"11/25/2019","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-25"},{"SOURCE_ROW_NUMBER":"127733","CASSETTE_NO":"58319007","SAMPLE_DT":"11/25/2019","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-25"},{"SOURCE_ROW_NUMBER":"57921","CASSETTE_NO":"58318911","SAMPLE_DT":"11/25/2019","QUARTZ_PCT":"00.4","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-25"},{"SOURCE_ROW_NUMBER":"108","CASSETTE_NO":"58319002","SAMPLE_DT":"11/25/2019","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"26","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-25"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":3331,"firstDate":"2006-03-27","lastDate":"2020-05-04","metrics":{"ss":537,"amountDue":2415949.4,"contested":71,"amountPaid":2415949.4,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":2784596},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"544435","VIOLATION_NO":"9149127","VIOLATION_ISSUE_DT":"05/04/2020","SIG_SUB":"Y","PART_SECTION":"77.1607(n)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/04/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"123","CONTESTED_IND":"N","sourceDate":"2020-05-04"},{"SOURCE_ROW_NUMBER":"543478","VIOLATION_NO":"9149126","VIOLATION_ISSUE_DT":"03/12/2020","SIG_SUB":"N","PART_SECTION":"75.507","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/19/2020","PROPOSED_PENALTY":"185","AMOUNT_DUE":"185","AMOUNT_PAID":"185","CONTESTED_IND":"N","sourceDate":"2020-03-12"},{"SOURCE_ROW_NUMBER":"543539","VIOLATION_NO":"9149125","VIOLATION_ISSUE_DT":"02/20/2020","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/20/2020","PROPOSED_PENALTY":"5332","AMOUNT_DUE":"2268","AMOUNT_PAID":"2268","CONTESTED_IND":"N","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"545472","VIOLATION_NO":"9261075","VIOLATION_ISSUE_DT":"12/17/2019","SIG_SUB":"N","PART_SECTION":"75.1910(j)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/17/2019","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2019-12-17"},{"SOURCE_ROW_NUMBER":"545443","VIOLATION_NO":"9149124","VIOLATION_ISSUE_DT":"12/17/2019","SIG_SUB":"N","PART_SECTION":"49.16(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/18/2019","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2019-12-17"},{"SOURCE_ROW_NUMBER":"545442","VIOLATION_NO":"9149123","VIOLATION_ISSUE_DT":"12/17/2019","SIG_SUB":"N","PART_SECTION":"49.16","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/18/2019","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2019-12-17"},{"SOURCE_ROW_NUMBER":"545471","VIOLATION_NO":"9261074","VIOLATION_ISSUE_DT":"12/16/2019","SIG_SUB":"N","PART_SECTION":"75.1914(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/17/2019","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2019-12-16"},{"SOURCE_ROW_NUMBER":"545441","VIOLATION_NO":"9149122","VIOLATION_ISSUE_DT":"12/16/2019","SIG_SUB":"N","PART_SECTION":"75.380(d)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/17/2019","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2019-12-16"},{"SOURCE_ROW_NUMBER":"545444","VIOLATION_NO":"9149353","VIOLATION_ISSUE_DT":"12/12/2019","SIG_SUB":"N","PART_SECTION":"75.1911(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/17/2019","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"123","CONTESTED_IND":"N","sourceDate":"2019-12-12"},{"SOURCE_ROW_NUMBER":"545448","VIOLATION_NO":"9149438","VIOLATION_ISSUE_DT":"12/11/2019","SIG_SUB":"N","PART_SECTION":"75.1501(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"12/11/2019","PROPOSED_PENALTY":"482","AMOUNT_DUE":"482","AMOUNT_PAID":"482","CONTESTED_IND":"N","sourceDate":"2019-12-11"},{"SOURCE_ROW_NUMBER":"545470","VIOLATION_NO":"9261073","VIOLATION_ISSUE_DT":"12/10/2019","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/10/2019","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"123","CONTESTED_IND":"N","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"545469","VIOLATION_NO":"9261072","VIOLATION_ISSUE_DT":"12/10/2019","SIG_SUB":"N","PART_SECTION":"75.1107-13(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/11/2019","PROPOSED_PENALTY":"157","AMOUNT_DUE":"157","AMOUNT_PAID":"157","CONTESTED_IND":"N","sourceDate":"2019-12-10"}]}],"safety":{"href":"/api/v1/mines/1103156/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1103156/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1607","heading":"Loading and haulage equipment; operation.","id":"77.1607","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1607","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Vehicles shall follow at a safe distance; passing shall be limited to areas of adequate clearance and visibility.\n\n(b) Mobile equipment operators shall have full control of the equipment while it is in motion.\n\n(c) Equipment operating speeds shall be prudent and consistent with conditions of roadway, grades, clearance, visibility, traffic, and the type of equipment used.\n\n(d) Cabs of mobile equipment shall be kept free of extraneous materials.\n\n(e) Operators shall sit facing the direction of travel while operating equipment with dual controls.\n\n(f) When an equipment operator is present, men shall notify him before getting on or off equipment.\n\n(g) Equipment operators shall be certain, by signal or other means, that all persons are clear before starting or moving equipment.\n\n(h) Where possible, aerial tramways shall not be started until the tramway operator has ascertained that everyone is in the clear.\n\n(i) Dust control measures shall be taken where dust significantly reduces visibility of equipment operators.\n\n(j) Dippers, buckets, loading booms, or heavy suspended loads shall not be swung over the cabs of haulage vehicles until the drivers are out of the cabs and in safe locations, unless the trucks are designed specifically to protect the drivers from falling material.\n\n(k) Men shall not work or pass under the buckets or booms of loaders in operation.\n\n(l) Tires shall be deflated before repairs on them are started and adequate means shall be provided to prevent wheel locking rims from creating a hazard during tire inflation.\n\n(m) Electrically powered mobile equipment shall not be left unattended unless the master switch is in the off position, all operating controls are in the neutral position, and the brakes are set or other equivalent precautions are taken against rolling.\n\n(n) Mobile equipment shall not be left unattended unless the brakes are set. The wheels shall be turned into a bank or berm, or shall be blocked, when such equipment is parked on a grade.\n\n(o) Lights, flares, or other warning devices shall be posted when parked equipment creates a hazard to vehicular traffic.\n\n(p) Dippers, buckets, scraper blades, and similar movable parts shall be secured or lowered to the ground when not in use.\n\n(q) Shovel trailing cables shall not be moved with the shovel dipper unless cable slings or sleds are used.\n\n(r) Equipment which is to be hauled shall be loaded and protected so as to prevent sliding or spillage.\n\n(s) When moving between work areas, the equipment shall be secured in the travel position.\n\n(t) Any load extending more than 4 feet beyond the rear of the vehicle body should be marked clearly with a red flag by day and a red light at night.\n\n(u) Tow bars shall be used to tow heavy equipment and a safety chain shall be used in conjunction with each tow bar.\n\n(v) Railroad cars shall be kept under control at all times by the car dropper. Cars shall be dropped at a safe rate and in a manner that will insure that the car dropper maintains a safe position while working and traveling around the cars.\n\n(w) Railroad cars shall not be coupled or uncoupled manually from the inside of curves unless the railroad and cars are so designed to eliminate any hazard from coupling or uncoupling cars from inside of curves.\n\n(x) Persons shall wear safety belts when dropping railroad cars.\n\n(y) Railcars shall not be left on sidetracks unless ample clearance is provided for traffic on adjacent tracks.\n\n(z) Parked railcars, unless held effectively by brakes, shall be blocked securely.\n\n(aa) Railroad cars and all trucks shall be trimmed properly when they have been loaded higher than the confines of their cargo space.\n\n(bb) When the entire length of a conveyor is visible from the starting switch, the operator shall visually check to make certain that all persons are in the clear before starting the conveyor. When the entire length of the conveyor is not visible from the starting switch, a positive audible or visible warning system shall be installed and operated to warn persons that the conveyor will be started.\n\n(cc) Unguarded conveyors with walkways shall be equipped with emergency stop devices or cords along their full length.\n\n(dd) Adequate backstops or brakes shall be installed on inclined-conveyor drive units to prevent conveyors from running in reverse if a hazard to personnel would be caused.\n\n(ee) Aerial tram conveyor buckets shall not be overloaded, and feed shall be regulated to prevent spillage.","occurrenceCount":1},{"chapter":"I","heading":"Power connection points.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.507","part":"75","subchapter":"O","subpart":"F","id":"75.507","citation":"30 CFR 75.507","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1910","heading":"Nonpermissible diesel-powered equipment; electrical system design and performance requirements.","id":"75.1910","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1910","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"Electrical circuits and components associated with or connected to electrical systems on nonpermissible diesel-powered equipment utilizing storage batteries and integral charging systems, except for the special category of equipment under § 75.1908(d), must conform to the following requirements:\n\n(a) Overload and short circuit protection must be provided for electric circuits and components in accordance with §§ 75.518 and 75.518-1 of this part;\n\n(b) Each electric conductor from the battery to the starting motor must be protected against short circuit by fuses or other circuit-interrupting devices placed as near as practicable to the battery terminals;\n\n(c) Each branch circuit conductor connected to the main circuit between the battery and charging generator must be protected against short circuit by fuses or other automatic circuit-interrupting devices;\n\n(d) The electrical system shall be equipped with a circuit-interrupting device by means of which all power conductors can be deenergized. The device must be located as close as practicable to the battery terminals and be designed to operate within its electrical rating without damage. The device shall not automatically reset after being actuated. All magnetic circuit-interrupting devices must be mounted in a manner to preclude their closing by force of gravity;\n\n(e) Each motor and charging generator must be protected by an automatic overcurrent device. One protective device will be acceptable when two motors of the same rating operate simultaneously and perform virtually the same duty;\n\n(f) Each ungrounded conductor must have insulation compatible with the impressed voltage. Insulation materials must be resistant to deterioration from engine heat and oil. Electric conductors must meet the applicable requirements of §§ 75.513 and 75.513-1, except electric conductors for starting motors, which must only meet the requirements of § 75.513;\n\n(g) All wiring must have adequate mechanical protection to prevent damage to the cable that might result in short circuits;\n\n(h) Sharp edges and corners must be removed at all points where there is a possibility of damaging wires, cables, or conduits by cutting or abrasion. The insulation of the cables within a battery box must be protected against abrasion;\n\n(i) When insulated wires other than cables pass through metal frames, the holes must be substantially bushed with insulated bushings. Cables must enter metal frames of motors, splice boxes, and electric components only through proper fittings. All electrical connections and splices must be mechanically and electrically efficient, and suitable connectors shall be used. All electrical connectors or splices in insulated wire must be reinsulated at least to the same degree of protection as the remainder of the wire;\n\n(j) The battery must be secured to prevent movement, and must be protected from external damage by position. Batteries that are not protected from external damage by position must be enclosed in a battery box. Flame-resistant insulation treated to resist chemical reaction to electrolyte must be provided on battery connections to prevent battery terminals from contacting conducting surfaces;\n\n(k) A battery box, including the cover, must be constructed of steel with a minimum thickness of 1/8 inch, or of a material other than steel that provides equivalent strength;\n\n(l) Battery-box covers must be lined with a flame-resistant insulating material permanently attached to the underside of the cover, unless equivalent protection is provided. Battery-box covers must be provided with a means for securing them in closed position. At least 1/2 inch of air space must be provided between the underside of the cover and the top of the battery, including terminals;\n\n(m) Battery boxes must be provided with ventilation openings to prevent the accumulation of flammable or toxic gases or vapors within the battery box. The size and locations of openings for ventilation must prevent direct access to battery terminals;\n\n(n) The battery must be insulated from the battery-box walls and supported on insulating materials. Insulating materials that may be subject to chemical reaction with electrolyte must be treated to resist such action; and\n\n(o) Drainage holes must be provided in the bottom of each battery box.","occurrenceCount":1},{"chapter":"I","heading":"Equipment and maintenance requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-49/subpart-B/section-49.16","part":"49","subchapter":"H","subpart":"B","id":"49.16","citation":"30 CFR 49.16","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 49—MINE RESCUE TEAMS","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1914","heading":"Maintenance of diesel-powered equipment.","id":"75.1914","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1914","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Diesel-powered equipment shall be maintained in approved and safe condition or removed from service.\n\n(b) Maintenance and repairs of approved features and those features required by §§ 75.1909 and 75.1910 on diesel-powered equipment shall be made only by a person qualified under § 75.1915.\n\n(c) The water scrubber system on diesel-powered equipment shall be drained and flushed, by a person who is trained to perform this task, at least once on each shift in which the equipment is operated.\n\n(d) The intake air filter on diesel-powered equipment shall be replaced or serviced, by a person who is trained to perform this task, when the intake air pressure drop device so indicates or when the engine manufacturer's maximum allowable air pressure drop level is exceeded.\n\n(e) Mobile diesel-powered equipment that is to be used during a shift shall be visually examined by the equipment operator before being placed in operation. Equipment defects affecting safety shall be reported promptly to the mine operator.\n\n(f) All diesel-powered equipment shall be examined and tested weekly by a person qualified under § 75.1915.\n\n(1) Examinations and tests shall be conducted in accordance with approved checklists and manufacturers' maintenance manuals.\n\n(2) Persons performing weekly examinations and tests of diesel-powered equipment under this paragraph shall make a record when the equipment is not in approved or safe condition. The record shall include the equipment that is not in approved or safe condition, the defect found, and the corrective action taken.\n\n(g) Undiluted exhaust emissions of diesel engines in diesel-powered equipment approved under part 36 and heavy-duty nonpermissible diesel-powered equipment as defined in § 75.1908(a) in use in underground coal mines shall be tested and evaluated weekly by a person who is trained to perform this task. The mine operator shall develop and implement written standard operating procedures for such testing and evaluation that specify the following:\n\n(1) The method of achieving a repeatable loaded engine operating condition for each type of equipment;\n\n(2) Sampling and analytical methods (including calibration of instrumentation) that are capable of accurately detecting carbon monoxide in the expected concentrations;\n\n(3) The method of evaluation and interpretation of the results;\n\n(4) The concentration or changes in concentration of carbon monoxide that will indicate a change in engine performance. Carbon monoxide concentration shall not exceed 2500 parts per million; and\n\n(5) The maintenance of records necessary to track engine performance.\n\n(h) Recordkeeping. Records required by paragraphs (f)(2) and (g)(5) shall be—\n\n(1) Recorded in a secure book that is not susceptible to alteration, or recorded electronically in a computer system that is secure and not susceptible to alteration; and\n\n(2) Retained at a surface location at the mine for at least 1 year and made available for inspection by an authorized representative of the Secretary and by miners' representatives.\n\n(i) Diesel-powered equipment must be maintained in accordance with this part as of November 25, 1997.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1911","heading":"Fire suppression systems for diesel-powered equipment and fuel transportation units.","id":"75.1911","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1911","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) The fire suppression system required by §§ 75.1907 and 75.1909 shall be a multipurpose dry chemical type (ABC) fire suppression system listed or approved by a nationally recognized independent testing laboratory and appropriate for installation on diesel-powered equipment and fuel transportation units.\n\n(1) The system shall be installed in accordance with the manufacturer's specifications and the limitations of the listing or approval.\n\n(2) The system shall be installed in a protected location or guarded to minimize physical damage from routine vehicle operations.\n\n(3) Suppressant agent distribution tubing or piping shall be secured and protected against damage, including pinching, crimping, stretching, abrasion, and corrosion.\n\n(4) Discharge nozzles shall be positioned and aimed for maximum fire suppression effectiveness. Nozzles shall also be protected against the entrance of foreign materials such as mud, coal dust, or rock dust.\n\n(b) The fire suppression system shall provide fire suppression and, if automatic, fire detection for the engine including the starter, transmission, hydraulic pumps and tanks, fuel tanks, exposed brake units, air compressors and battery areas on diesel-powered equipment and electric panels or controls used on fuel transportation units and other areas as necessary.\n\n(c) If automatic, the fire suppression system shall include audible and visual alarms to warn of fires or system faults.\n\n(d) The fire suppression system shall provide for automatic engine shutdown. If the fire suppression system is automatic, engine shutdown and discharge of suppressant agent may be delayed for a maximum of 15 seconds after the fire is detected by the system.\n\n(e) The fire suppression system shall be operable by at least two manual actuators. One actuator shall be located on each side of the equipment. If the equipment is provided with an operator's compartment, one of the manual actuators shall be located in the compartment within reach of the operator.\n\n(f) The fire suppression system shall remain operative in the event of engine shutdown, equipment electrical system failure, or failure of any other equipment system.\n\n(g) The electrical components of each fire suppression system installed on equipment used where permissible electric equipment is required shall be permissible or intrinsically safe and such components shall be maintained in permissible or intrinsically safe condition.\n\n(h) Electrically operated detection and actuation circuits shall be monitored and provided with status indicators showing power and circuit continuity. If the system is not electrically operated, a means shall be provided to indicate the functional readiness status of the detection system.\n\n(i) Each fire suppression system shall be tested and maintained in accordance with the manufacturer's recommended inspection and maintenance program and as required by the nationally recognized independent testing laboratory listing or approval, and be visually inspected at least once each week by a person trained to make such inspections.\n\n(j) Recordkeeping. Persons performing inspections and tests of fire suppression systems under paragraph (i) shall record when a fire suppression system does not meet the installation or maintenance requirements of this section.\n\n(1) The record shall include the equipment on which the fire suppression system did not meet the installation or maintenance requirements of this section, the defect found, and the corrective action taken.\n\n(2) Records are to be kept manually in a secure manner not susceptible to alteration or recorded electronically in a secured computer system that is not susceptible to alteration.\n\n(3) Records shall be maintained at a surface location at the mine for one year and made available for inspection by an authorized representative of the Secretary and miners' representatives.\n\n(k) All miners normally assigned to the active workings of the mine shall be instructed about the hazards inherent to the operation of the fire suppression systems and, where appropriate, the safeguards available for each system.\n\n(l) For purposes of § 75.380(f), a fire suppression system installed on diesel-powered equipment and meeting the requirements of this section is equivalent to a fire suppression system meeting the requirements of §§ 75.1107-3 through 75.1107-16.","occurrenceCount":1},{"chapter":"I","heading":"Emergency evacuations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1501","part":"75","subchapter":"O","subpart":"P","id":"75.1501","citation":"30 CFR 75.1501","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-13","heading":"Approval of other fire suppression devices.","id":"75.1107-13","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-13","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Notwithstanding the provisions of §§ 75.1107-1 through 75.1107-12 the District Manager for the District in which the mine is located may approve any other fire suppression system or device which provides substantially equivalent protection as would be achieved through compliance with those sections: Provided, That no such system or device shall be approved which does not meet the following minimum criteria:\n\n(a) Components shall be approved by the Secretary, or where appropriate be listed as approved by a nationally recognized agency approved by the Secretary.\n\n(b) The fire suppression equipment shall be designed to withstand the rigors of the mine environment. Where used, pressure vessels shall conform with the requirements of section 3603, 3606, 3607, 3707, and 3708 of National Fire Code No. 22 “Water Tanks for Private Fire Protection” (NFPA No. 22-1971).\n\n(c) The cover of hose of fire suppression devices, if used on the protected equipment, shall meet the flame-resistant requirements of Part 18 of this chapter (Bureau of Mines Schedule 2G).\n\n(d) Extinguishing agents shall not create a serious toxic or other hazard to the miners.\n\n(e) The electrical components of the fire suppression device shall meet the requirements for electrical components of the mining machine.\n\n(f) Where used, manual actuators for initiating the operation of the fire suppression device shall be readily accessible to the machine operator. On unattended equipment, an automatic as well as a manual actuator shall be provided.\n\n(g) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(h) On unattended equipment, the sensor system shall have a means for checking its operative condition.\n\n(i) The fire suppression agent shall be directed at locations where the greatest potential fire hazard exists. Cable reel compartments shall receive approximately twice the quantity of extinguishing agent as each other hazardous location.\n\n(j) The rate of application of the fire suppression agent shall minimize the time for quenching and the total quantity applied shall be sufficient to quench a fire in its incipient stage.\n\n(k) The effectiveness of the quenching agent, together with the total quantity of agent and its rate of application shall provide equivalent protection to the water, dry powder, or foam systems described in §§ 75.1107-7, 75.1107-9, and 75.1107-10.\n\n(l) The fire suppression device shall be operable at all times electrical power is connected to the mining machine, except during tramming when the machine is in a ventilated passageway, the water hose if used, may be switched from one hydrant to another in a reasonable time and except in systems meeting the minimum special criteria set forth in paragraph (m) of this section.\n\n(m) Systems for attended equipment which are not continuously connected to a water supply shall not be approved unless they meet the following minimum criteria:\n\n(1) The machine shall be equipped with a firehose at least 50 feet in length which is continuously connected to the machine-mounted portion of the system.\n\n(2) Hydrants in proximity to the area where the machine is to be used shall be equipped with sufficient hose to reach the machine at any time it is connected to a power source.\n\n(3) The machine shall be used only where the operator (or other person) will always be in ventilated air uncontaminated by smoke and hot gases from the machine fire while extending the machine-mounted hose to connect with the hydrant-mounted hose.\n\n(4) The machine and hydrant hoses shall be readily accessible so that the connection between the machine-mounted hose and the hydrant hose can be made and water flow achieved in not more than 3 minutes under actual mining conditions for any location of the machine while electric power is connected.\n\n(5) The rate of water flow at the machine shall provide a minimum of 0.12 gallon of water per minute per square foot of top surface area (excluding conveyors, cutters, and gathering heads). The water shall discharge to all hazardous locations on the machine.\n\n(6) Hose, if used on the machine, in addition to meeting the flame resistant requirements for the cover of a hose provided in §§ 75.1107-3(b) and 75.1107-13(c) shall have a minimum burst pressure 4 times that of the static water pressure at the mining machine. Fabric braid hose shall have at least two braids, and wire braid hose shall have at least a single braid.\n\n(7) In addition to the hose located at the hydrant (which is intended to be connected to the hose on the machine) the firefighting equipment required by § 75.1100-2(a) shall be maintained.\n\n(8) A sufficient number of trained miners shall be kept on the section when the machine is in use to connect the machine hose to the hydrant hose and achieve water flow in not more than 3 minutes.\n\n[37 FR 15303, July 29, 1972]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1103156","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}