{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1103147","name":"Prairie Eagle-Underground","status":"Active","status_date":"2006-08-02","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IL","county":"Perry","nearest_town":"Cutler","operator_id":"P23970","operator_name":"Knight Hawk Coal, LLC","controller_id":"0165661","controller_name":"CBR Investments, LLC; CBR Investments II, LLC","district":"C08","office":"Marion IL Field Office","employees":290,"latitude":38.086111,"longitude":-89.518889},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":32482},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1103147","name":"Prairie Eagle-Underground"},"operator":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"controller":{"type":"controller","id":"0165661","name":"CBR Investments, LLC; CBR Investments II, LLC"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14544","name":"Franklin D  Robertson  et al"},"object":{"type":"mine","id":"1103147","name":"Prairie Eagle-Underground"},"validFrom":"1998-03-01","validTo":"2012-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|C14544|1998-03-01|2012-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"object":{"type":"mine","id":"1103147","name":"Prairie Eagle-Underground"},"validFrom":"2005-04-27","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14544","name":"Franklin D  Robertson  et al"},"object":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"validFrom":"2005-04-27","validTo":"2012-05-31","current":false,"derived":true,"evidenceMineId":"1103147","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|C14544|1998-03-01|93187"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14544","name":"James O  Bunn  et al"},"object":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"validFrom":"2005-04-27","validTo":"2012-05-31","current":false,"derived":true,"evidenceMineId":"1103147","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|C14544|1998-03-01|93188"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0105613","name":"Franklin D.  Robertson et al"},"object":{"type":"mine","id":"1103147","name":"Prairie Eagle-Underground"},"validFrom":"2012-06-01","validTo":"2021-01-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|0105613|2012-06-01|2021-01-03"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0105613","name":"Franklin D.  Robertson et al"},"object":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"validFrom":"2012-06-01","validTo":"2021-01-03","current":false,"derived":true,"evidenceMineId":"1103147","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|0105613|2012-06-01|18542"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0105613","name":"Arch Coal Inc. et al"},"object":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"validFrom":"2012-06-01","validTo":"2021-01-03","current":false,"derived":true,"evidenceMineId":"1103147","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|0105613|2012-06-01|18543"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0105613","name":"James O.  Bunn et al"},"object":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"validFrom":"2012-06-01","validTo":"2021-01-03","current":false,"derived":true,"evidenceMineId":"1103147","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|0105613|2012-06-01|18544"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0159683","name":"CBR Investments LLC et al"},"object":{"type":"mine","id":"1103147","name":"Prairie Eagle-Underground"},"validFrom":"2021-01-04","validTo":"2021-11-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|0159683|2021-01-04|2021-11-16"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0159683","name":"CBR Investments LLC et al"},"object":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"validFrom":"2021-01-04","validTo":"2021-11-16","current":false,"derived":true,"evidenceMineId":"1103147","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|0159683|2021-01-04|33163"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0159683","name":"Arch Coal Inc et al"},"object":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"validFrom":"2021-01-04","validTo":"2021-11-16","current":false,"derived":true,"evidenceMineId":"1103147","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|0159683|2021-01-04|33164"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0165661","name":"CBR Investments II, LLC et al"},"object":{"type":"mine","id":"1103147","name":"Prairie Eagle-Underground"},"validFrom":"2021-11-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|0165661|2021-11-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0165661","name":"CBR Investments II, LLC et al"},"object":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"validFrom":"2021-11-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"1103147","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|0165661|2021-11-17|34717"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0165661","name":"CBR Investments, LLC et al"},"object":{"type":"operator","id":"P23970","name":"Knight Hawk Coal, LLC"},"validFrom":"2021-11-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"1103147","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103147|P23970|2005-04-27|0165661|2021-11-17|34718"}}],"coverage":{"historyRecords":9,"edgeCount":14,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":344,"firstDate":"2007-04-23","lastDate":"2026-07-30","metrics":{"daysLost":16015,"injuries":295,"fatalities":1,"recentRows":152,"restrictedDays":1424,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"254746","DOCUMENT_NO":"220262150019","ACCIDENT_DT":"07/30/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"On 07/30/2026 a roof fall occurred in Unit 1 specifically, room #2 at our 3+60 line at the station of 6+60 in the 2E/4N/3ME panel. The roof fall measured 18ft wide, 28ft long, and 2-3ft in height. No one was injured.","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"246178","DOCUMENT_NO":"220262100027","ACCIDENT_DT":"07/28/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"33","NARRATIVE":"Employee was cleaning a rock off the top of continuous miner. As they pulled the rock off the CM they were struck in the left ankle. This resulted in a fracture of the left ankle. The employee was taken off work due to doctor's restrictions as of 7/29/2026.","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"155802","DOCUMENT_NO":"220262080032","ACCIDENT_DT":"07/22/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee was trying to get a stuck drill steel out of the roof. When they reached up with right hand and yanked down the steel, they felt a sharp pain and a pop in their right shoulder. Employee was taken off work on 07/23/2026 due to doctor's restrictions.","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"151497","DOCUMENT_NO":"220262590019","ACCIDENT_DT":"07/14/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"Employee was attempting to remove a cover on the pan jack pin of a CM. While swinging a hammer, on the back swing, left elbow struck the underside of the CM head. Employee continued to work until 9/14/2026 when they were taken off work due to doctor's restrictions.","sourceDate":"2026-07-14"},{"SOURCE_ROW_NUMBER":"168647","DOCUMENT_NO":"220261890026","ACCIDENT_DT":"07/06/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"Employee was unloading supplies out of the back of a mantrip. Underneath the supplies was a steel band that had been cut. As the employee was unloading the supplies, the employee was struck in the left eye by the steel band.","sourceDate":"2026-07-06"},{"SOURCE_ROW_NUMBER":"267561","DOCUMENT_NO":"220262710035","ACCIDENT_DT":"06/19/2026","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","NARRATIVE":"Approximately 5 months ago the employee began having problems with their hands going numb at night. They state their elbows hurt as well. Employee continued to work until 09/25/2026 when they went off for surgery.","sourceDate":"2026-06-19"},{"SOURCE_ROW_NUMBER":"271875","DOCUMENT_NO":"220261480019","ACCIDENT_DT":"05/26/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"84","NARRATIVE":"Employee was attempting to remove an insert out of EE's drill steel. EE was beating out EE's steel when EE felt a pop in EE's right elbow. Doctor's restrictions took EE off work on 5/27/2026.","sourceDate":"2026-05-26"},{"SOURCE_ROW_NUMBER":"203010","DOCUMENT_NO":"220261800026","ACCIDENT_DT":"05/19/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee was attempting to install a roof bolt. As they were attempting to install the roof bolt in the hole, they heard and felt their right shoulder pop. Employee continued to work until they were taken off due to doctor's restrictions on 6/26/2026.","sourceDate":"2026-05-19"},{"SOURCE_ROW_NUMBER":"177311","DOCUMENT_NO":"220261400008","ACCIDENT_DT":"05/18/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was loading supplies into EE's scoop. The employee's foot got caught and EE fell. As EE was falling, EE reached EE's arm out and fell onto a pallet. A nail from the pallet poked EE in the right forearm requiring one stich to close the wound.","sourceDate":"2026-05-18"},{"SOURCE_ROW_NUMBER":"177310","DOCUMENT_NO":"220261350007","ACCIDENT_DT":"05/13/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was roof bolting and dropped wrench on EE's left pinky toe.  This resulted in a fracture of left pinky toe.","sourceDate":"2026-05-13"},{"SOURCE_ROW_NUMBER":"254745","DOCUMENT_NO":"220261170002","ACCIDENT_DT":"04/22/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"73","NARRATIVE":"Employee was installing the center pin while roof bolting and a rock fell striking the back of the employee's left leg below the knee. The injury resulted in a fracture of the employee's left leg. The employee was taken off work the following day (4-23-2026) due to doctor's restrictions.","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"43883","DOCUMENT_NO":"220261170001","ACCIDENT_DT":"04/22/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Contact with electrical current","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was hooking up a charging nip to a coal hauler battery. While tightening the nip the employee received burns on EE's left hand and left ring finger. Some of the burns are possible 2nd degree burns. The employee works for Jennmar services and is under Knight Hawk Coal, Prairie Eagle Underground Mine's supervision.","sourceDate":"2026-04-22"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-08-02","lastDate":"2006-08-02","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":3645,"firstDate":"2006-09-11","lastDate":"2026-08-17","metrics":{"ss":666,"delinquent":3319,"recentRows":1798,"paidPenalty":1918235,"proposedPenalty":2492442.5,"currentAssessment":2098752},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2992007","VIOLATION_NO":"5016526","ISSUE_DT":"08/17/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"336.00","CURRENT_ASSESSMENT_AMT":"336.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"2991999","VIOLATION_NO":"5016926","ISSUE_DT":"08/17/2026","CFR_STANDARD_CD":"75.1714-6","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"2991998","VIOLATION_NO":"5016925","ISSUE_DT":"08/17/2026","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"2991997","VIOLATION_NO":"5016924","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2991996","VIOLATION_NO":"5016923","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"432.00","CURRENT_ASSESSMENT_AMT":"432.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2991962","VIOLATION_NO":"5016525","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2991995","VIOLATION_NO":"5016922","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2991985","VIOLATION_NO":"5016844","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"336.00","CURRENT_ASSESSMENT_AMT":"336.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2991984","VIOLATION_NO":"5016843","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"336.00","CURRENT_ASSESSMENT_AMT":"336.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2991994","VIOLATION_NO":"5016921","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"336.00","CURRENT_ASSESSMENT_AMT":"336.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"2991993","VIOLATION_NO":"5016920","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2312.00","CURRENT_ASSESSMENT_AMT":"2312.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"2991983","VIOLATION_NO":"5016841","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"883.00","CURRENT_ASSESSMENT_AMT":"883.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":393,"firstDate":"2010-05-13","lastDate":"2026-06-11","metrics":{"appeals":0,"decisions":377,"recentRows":241,"decisionPenalty":690195,"originalPenalty":1158806.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"459501","VIOLATION_NO":"9789611","DOCKET_NO":"LAKE 2026-0003","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"18504.00","DECISION_PENALTY_AMT":"5575.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"459395","VIOLATION_NO":"9786733","DOCKET_NO":"LAKE 2025-0293","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8529.00","DECISION_PENALTY_AMT":"6823.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"458638","VIOLATION_NO":"9786732","DOCKET_NO":"LAKE 2025-0293","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5574.00","DECISION_PENALTY_AMT":"4459.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"458637","VIOLATION_NO":"9786100","DOCKET_NO":"LAKE 2025-0293","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5144.00","DECISION_PENALTY_AMT":"3822.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"458100","VIOLATION_NO":"9789014","DOCKET_NO":"LAKE 2025-0293","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7084.00","DECISION_PENALTY_AMT":"6000.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"458099","VIOLATION_NO":"9549755","DOCKET_NO":"LAKE 2025-0293","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3184.00","DECISION_PENALTY_AMT":"2200.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"458037","VIOLATION_NO":"9789401","DOCKET_NO":"LAKE 2025-0293","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2936.00","DECISION_PENALTY_AMT":"1968.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"458036","VIOLATION_NO":"9786922","DOCKET_NO":"LAKE 2025-0293","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2936.00","DECISION_PENALTY_AMT":"2068.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"167290","VIOLATION_NO":"9789617","DOCKET_NO":"LAKE 2026-0003","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6037.00","DECISION_PENALTY_AMT":"2713.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"166941","VIOLATION_NO":"9789613","DOCKET_NO":"LAKE 2026-0003","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"20047.00","DECISION_PENALTY_AMT":"6037.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"166379","VIOLATION_NO":"9783190","DOCKET_NO":"LAKE 2025-0293","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1431.00","DECISION_PENALTY_AMT":"1431.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"166083","VIOLATION_NO":"9786178","DOCKET_NO":"LAKE 2025-0293","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1968.00","DECISION_PENALTY_AMT":"1000.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":20273,"firstDate":"2006-09-11","lastDate":"2026-10-08","metrics":{"recentRows":10493,"cpdmSamples":14954,"voidSamples":3063,"validSamples":17210,"maxConcentration":133.303,"concentrationTotal":14342.155},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2176337","SMP_TAKEN_DT":"10/8/2026","CONC":".453","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"1921096","SMP_TAKEN_DT":"10/8/2026","CONC":".689","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"1836158","SMP_TAKEN_DT":"10/8/2026","CONC":"1.02","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2944387","SMP_TAKEN_DT":"10/7/2026","CONC":"1.278","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2859437","SMP_TAKEN_DT":"10/7/2026","CONC":".801","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2432751","SMP_TAKEN_DT":"10/7/2026","CONC":".657","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2432689","SMP_TAKEN_DT":"10/7/2026","CONC":".771","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2347429","SMP_TAKEN_DT":"10/7/2026","CONC":"1.118","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2176502","SMP_TAKEN_DT":"10/7/2026","CONC":".386","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1921187","SMP_TAKEN_DT":"10/7/2026","CONC":".622","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1751286","SMP_TAKEN_DT":"10/7/2026","CONC":"1.404","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1750861","SMP_TAKEN_DT":"10/7/2026","CONC":"1.137","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":106,"firstDate":"2007-12-05","lastDate":"2026-08-12","metrics":{"linkedIssuances":106},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":394,"firstDate":"2009-06-08","lastDate":"2026-08-11","metrics":{"decisions":378,"ssChanged":64,"recentRows":239,"decisionPenalty":691195,"proposedPenalty":1346199},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"450120","CITATION_NO":"5016920","CITATION_ISSUE_DT":"08/11/2026","DOCKET_NO":"LAKE 2027-0003","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2312.00","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"393310","CITATION_NO":"5016838","CITATION_ISSUE_DT":"08/10/2026","DOCKET_NO":"LAKE 2027-0003","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4047.00","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"393123","CITATION_NO":"5016520","CITATION_ISSUE_DT":"08/03/2026","DOCKET_NO":"LAKE 2027-0004","CFR_STANDARD_CODE":"50.10(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"7555.00","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"281158","CITATION_NO":"5016834","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"LAKE 2027-0003","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5574.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"279997","CITATION_NO":"5016508","CITATION_ISSUE_DT":"06/22/2026","DOCKET_NO":"LAKE 2027-0003","CFR_STANDARD_CODE":"75.1909(a)(8)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2133.00","sourceDate":"2026-06-22"},{"SOURCE_ROW_NUMBER":"55076","CITATION_NO":"9789076","CITATION_ISSUE_DT":"10/28/2025","DOCKET_NO":"LAKE 2026-0060","DECISION_DT":"03/31/2026","CFR_STANDARD_CODE":"75.1732(b)(6)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3736.00","DECISION_PENALTY_AMT":"2802.00","sourceDate":"2025-10-28"},{"SOURCE_ROW_NUMBER":"337818","CITATION_NO":"5011631","CITATION_ISSUE_DT":"09/04/2025","DOCKET_NO":"LAKE 2026-0018","DECISION_DT":"02/20/2026","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3736.00","DECISION_PENALTY_AMT":"1679.00","sourceDate":"2025-09-04"},{"SOURCE_ROW_NUMBER":"393392","CITATION_NO":"9789626","CITATION_ISSUE_DT":"09/03/2025","DOCKET_NO":"LAKE 2026-0106","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"49571.00","sourceDate":"2025-09-03"},{"SOURCE_ROW_NUMBER":"167090","CITATION_NO":"9789627","CITATION_ISSUE_DT":"09/03/2025","DOCKET_NO":"LAKE 2026-0106","CFR_STANDARD_CODE":"75.360(b)(3)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"33227.00","sourceDate":"2025-09-03"},{"SOURCE_ROW_NUMBER":"223808","CITATION_NO":"5011627","CITATION_ISSUE_DT":"08/26/2025","DOCKET_NO":"LAKE 2026-0018","DECISION_DT":"02/20/2026","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3736.00","DECISION_PENALTY_AMT":"1679.00","sourceDate":"2025-08-26"},{"SOURCE_ROW_NUMBER":"54161","CITATION_NO":"9789617","CITATION_ISSUE_DT":"08/13/2025","DOCKET_NO":"LAKE 2026-0003","DECISION_DT":"06/11/2026","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"6037.00","DECISION_PENALTY_AMT":"2713.00","sourceDate":"2025-08-13"},{"SOURCE_ROW_NUMBER":"391919","CITATION_NO":"9789613","CITATION_ISSUE_DT":"08/11/2025","DOCKET_NO":"LAKE 2026-0003","DECISION_DT":"06/11/2026","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"20047.00","DECISION_PENALTY_AMT":"6037.00","sourceDate":"2025-08-11"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":762,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":151,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":9,"firstDate":"2005-04-27","lastDate":"2005-04-27","metrics":{"recentRows":0,"currentOperatorTenures":9,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":642,"firstDate":"2006-08-15","lastDate":"2026-10-07","metrics":{"inspectors":1358,"recentRows":261,"onSiteHours":35930.5,"inspectionHours":62972.75,"inspectionSamples":4459},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"111599","EVENT_NO":"F016B0F","INSPECTION_BEGIN_DT":"10/07/2026","INSPECTION_END_DT":"10/07/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"333657","EVENT_NO":"F00C1C5","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"46.75","SUM_TOTAL_ON_SITE_HOURS":"22","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"849473","EVENT_NO":"F01B414","INSPECTION_BEGIN_DT":"09/28/2026","INSPECTION_END_DT":"09/28/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"804520","EVENT_NO":"F03ABAA","INSPECTION_BEGIN_DT":"09/14/2026","INSPECTION_END_DT":"09/16/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"939654","EVENT_NO":"F01B413","INSPECTION_BEGIN_DT":"09/08/2026","INSPECTION_END_DT":"09/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"937092","EVENT_NO":"F00BE30","INSPECTION_BEGIN_DT":"09/02/2026","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"57","SUM_TOTAL_ON_SITE_HOURS":"31.5","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"408338","EVENT_NO":"7019284","INSPECTION_BEGIN_DT":"09/01/2026","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"142.5","SUM_TOTAL_ON_SITE_HOURS":"94","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"1002701","EVENT_NO":"F01B412","INSPECTION_BEGIN_DT":"08/27/2026","INSPECTION_END_DT":"08/27/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"664977","EVENT_NO":"7007171","INSPECTION_BEGIN_DT":"08/19/2026","INSPECTION_END_DT":"08/19/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"1085655","EVENT_NO":"F01B411","INSPECTION_BEGIN_DT":"08/17/2026","INSPECTION_END_DT":"08/17/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"361856","EVENT_NO":"F000587","INSPECTION_BEGIN_DT":"08/12/2026","INSPECTION_END_DT":"09/16/2026","ACTIVITY_CODE":"E07","ACTIVITY":"Non-Fatal Accident Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"7.75","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"374777","EVENT_NO":"F01B410","INSPECTION_BEGIN_DT":"08/05/2026","INSPECTION_END_DT":"08/05/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-08-05"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":254,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":157729,"employees":294,"production":1080105},"2026-Q1":{"hours":158784,"employees":304,"production":1169000},"2025-Q4":{"hours":148135,"employees":296,"production":1053280},"2025-Q3":{"hours":146718,"employees":284,"production":990992},"2025-Q2":{"hours":153297,"employees":297,"production":1167390},"2025-Q1":{"hours":145160,"employees":296,"production":970036},"2024-Q4":{"hours":141455,"employees":295,"production":937791},"2024-Q3":{"hours":152434,"employees":295,"production":1012411},"2024-Q2":{"hours":149546,"employees":300,"production":1060034},"2024-Q1":{"hours":162052,"employees":302,"production":1103316},"2023-Q4":{"hours":147715,"employees":281,"production":987248},"2023-Q3":{"hours":155027,"employees":277,"production":1062166}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":58,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":533839,"employees":243,"production":3610441},"2018":{"hours":604227,"employees":270,"production":3944857},"2019":{"hours":610148,"employees":290,"production":4095032},"2020":{"hours":517436,"employees":271,"production":3778206},"2021":{"hours":535070,"employees":267,"production":4114075},"2022":{"hours":581984,"employees":270,"production":4271659},"2023":{"hours":615376,"employees":277,"production":4337390},"2024":{"hours":605487,"employees":298,"production":4113552},"2025":{"hours":593310,"employees":296,"production":4181698},"2026":{"hours":316513,"employees":300,"production":2249105}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":685,"firstDate":"2006-09-20","lastDate":"2026-08-25","metrics":{"recentRows":225,"doseOver100":209,"actDoseTotal":54752,"pelDoseTotal":43027},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"24325","EVENT_NO":"F01B40D","SURVEY_DATE":"08/25/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","ACT_DOSE_85":"106","PEL_DOSE_90":"94","SURVEY_TYPE":"I","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"24324","EVENT_NO":"F01B40D","SURVEY_DATE":"08/25/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","ACT_DOSE_85":"116","PEL_DOSE_90":"105","SURVEY_TYPE":"I","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"24323","EVENT_NO":"F01B40D","SURVEY_DATE":"08/25/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","ACT_DOSE_85":"125","PEL_DOSE_90":"113","SURVEY_TYPE":"I","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"24322","EVENT_NO":"F01B40D","SURVEY_DATE":"07/08/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","ACT_DOSE_85":"131","PEL_DOSE_90":"116","SURVEY_TYPE":"I","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"24321","EVENT_NO":"F01B40D","SURVEY_DATE":"07/08/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","ACT_DOSE_85":"109","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"24320","EVENT_NO":"F01B40D","SURVEY_DATE":"07/08/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","ACT_DOSE_85":"107","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"24330","EVENT_NO":"F03ABA5","SURVEY_DATE":"06/25/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","ACT_DOSE_85":"145","PEL_DOSE_90":"135","SURVEY_TYPE":"I","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"24329","EVENT_NO":"F03ABA5","SURVEY_DATE":"06/25/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","ACT_DOSE_85":"142","PEL_DOSE_90":"126","SURVEY_TYPE":"I","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"24328","EVENT_NO":"F03ABA5","SURVEY_DATE":"06/25/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","ACT_DOSE_85":"126","PEL_DOSE_90":"104","SURVEY_TYPE":"I","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"24327","EVENT_NO":"F03ABA5","SURVEY_DATE":"06/25/2026","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","ACT_DOSE_85":"48","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"24326","EVENT_NO":"F03ABA5","SURVEY_DATE":"06/25/2026","OCCUPATION_CD_DESC":"SURVEYOR","MACHINE_CD":"40","ACT_DOSE_85":"53","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"24304","EVENT_NO":"F00C1A7","SURVEY_DATE":"12/17/2025","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"66","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2025-12-17"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":963,"firstDate":"2006-12-11","lastDate":"2026-09-01","metrics":{"recentRows":497,"voidSamples":32,"maxQuartzPct":14.5,"validSamples":931,"quartzPctTotal":3023.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"93356","CASSETTE_NO":"58591069","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"01.2","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"FIRE BOSS PRE-SHIFT EXAMINER","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"102362","CASSETTE_NO":"58591050","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"92600","CASSETTE_NO":"58590846","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"03.1","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"89515","CASSETTE_NO":"58591397","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"04.5","QUARTZ_MICROGRAMS":"43","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"76404","CASSETTE_NO":"58591138","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"14028","CASSETTE_NO":"58590832","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"106109","CASSETTE_NO":"58590837","SAMPLE_DT":"07/28/2026","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"24","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"96137","CASSETTE_NO":"58591165","SAMPLE_DT":"07/28/2026","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"28","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"73830","CASSETTE_NO":"58590988","SAMPLE_DT":"07/28/2026","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"45910","CASSETTE_NO":"58590809","SAMPLE_DT":"07/28/2026","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"63906","CASSETTE_NO":"58590914","SAMPLE_DT":"07/22/2026","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"27","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"58808","CASSETTE_NO":"58590830","SAMPLE_DT":"07/22/2026","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":3801,"firstDate":"2006-09-11","lastDate":"2026-10-07","metrics":{"ss":695,"amountDue":2098752,"contested":1,"amountPaid":1918235,"recentRows":1901,"section104d":17,"unterminated":5,"proposedPenalty":2492442.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"541842","VIOLATION_NO":"5011276","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"541841","VIOLATION_NO":"5011275","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"541590","VIOLATION_NO":"5017224","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"Y","PART_SECTION":"75.1103-5(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"14","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"541589","VIOLATION_NO":"5017223","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"Y","PART_SECTION":"75.1103-8(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"14","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"541588","VIOLATION_NO":"5016448","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"541586","VIOLATION_NO":"5011274","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"Y","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"541585","VIOLATION_NO":"5011273","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"541584","VIOLATION_NO":"5011272","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"541587","VIOLATION_NO":"5011762","VIOLATION_ISSUE_DT":"10/02/2026","SIG_SUB":"Y","PART_SECTION":"75.1914(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/02/2026","CONTESTED_IND":"N","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"541013","VIOLATION_NO":"5017008","VIOLATION_ISSUE_DT":"09/29/2026","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/29/2026","CONTESTED_IND":"N","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"541006","VIOLATION_NO":"9548797","VIOLATION_ISSUE_DT":"09/29/2026","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/29/2026","CONTESTED_IND":"N","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"540672","VIOLATION_NO":"5016952","VIOLATION_ISSUE_DT":"09/23/2026","SIG_SUB":"N","PART_SECTION":"75.1909(b)(5)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2026","CONTESTED_IND":"N","sourceDate":"2026-09-23"}]}],"safety":{"href":"/api/v1/mines/1103147/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1103147/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":298,"companyType":"Operating Subsidiary","components":[{"averageEmployees":298,"laborHours":605487,"mineType":"Underground","productionTons":4113552}],"county":"Perry","laborHours":605487,"mineName":"Prairie Eagle-Underground","mineType":"Underground","mshaId":"1103147","operatingAddress":"500 Cutler-Trico Rd, Percy, IL 62272","operatingCompany":"Knight Hawk Coal, Llc","operationType":"Mine only","productionTons":4113552,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Illinois","status":"Active","supplyRegion":"Illinois Basin","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-5","heading":"Automatic fire warning devices; actions and response.","id":"75.1103-5","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-5","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) When the carbon monoxide level reaches 10 parts per million above the established ambient level at any sensor location, automatic fire sensor and warning device systems shall provide an effective warning signal at the following locations:\n\n(1) At working sections and other work locations where miners may be endangered from a fire in the belt entry.\n\n(2) At a manned surface location where personnel have an assigned post of duty. The manned surface location must have:\n\n(i) A telephone or equivalent communication with all miners who may be endangered and\n\n(ii) A map or schematic that shows the locations of sensors, and the intended air flow direction at these locations. This map or schematic must be updated within 24 hours of any change in this information.\n\n(3) The automatic fire sensor and warning device system shall be monitored for a period of 4 hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in § 75.1103-4(e).\n\n(b) The fire sensor and warning device system shall include a means for rapid evaluation of electrical short and open circuits, ground faults, pneumatic leaks, or other defect detrimental to its proper operational condition.\n\n(c) Automatic fire sensor and warning devices shall include a manual reset feature.\n\n(d) When a malfunction or warning signal is received at the manned surface location, the sensors that are activated must be identified and appropriate personnel immediately notified.\n\n(e) Upon notification of a malfunction or warning signal, appropriate personnel must immediately initiate an investigation to determine the cause of the malfunction or warning signal and take the required actions set forth in paragraph (f) of this section.\n\n(f) If any sensor indicates a warning, the following actions must be taken unless the mine operator determines that the signal does not present a hazard to miners:\n\n(1) Appropriate personnel must notify miners in affected working sections, in affected areas where mechanized mining equipment is being installed or removed, and at other locations specified in the approved mine emergency evacuation and firefighting program of instruction; and\n\n(2) All miners in the affected areas, unless assigned emergency response duties, must be immediately withdrawn to a safe location identified in the mine emergency evacuation and firefighting program of instruction.\n\n(g) If the warning signal will be activated during calibration of sensors, personnel manning the surface location must be notified prior to and upon completion of calibration. Affected working sections, areas where mechanized mining equipment is being installed or removed, or other areas designated in the approved emergency evacuation and firefighting program of instruction must be notified at the beginning and completion of calibration.\n\n(h) If any fire detection component becomes inoperative, immediate action must be taken to repair the component. While repairs are being made, operation of the belt may continue if the following requirements are met:\n\n(1) If one sensor becomes inoperative, a trained person must continuously monitor for carbon monoxide at the inoperative sensor;\n\n(2) If two or more adjacent sensors become inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety. Alternatively, a trained person must be stationed at each inoperative sensor to monitor for carbon monoxide;\n\n(3) If the complete fire detection system becomes inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety;\n\n(4) Trained persons who conduct monitoring under this section must have two-way voice communication capability, at intervals not to exceed 2,000 feet, and must report carbon monoxide concentrations to the surface at intervals not to exceed one hour;\n\n(5) Trained persons who conduct monitoring under this section must immediately report to the surface any concentration of carbon monoxide that reaches 10 parts per million above the established ambient level, unless the mine operator knows that the source of the carbon monoxide does not present a hazard to miners; and\n\n(6) Handheld detectors used to monitor the belt entry under this section must have a detection level equivalent to that of the system's carbon monoxide sensors.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-8","heading":"Automatic fire sensor and warning device systems; examination and test requirements.","id":"75.1103-8","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-8","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Automatic fire sensor and warning device systems shall be examined at least once each shift when belts are operated as part of a production shift. A functional test of the warning signals shall be made at least once every seven days. Examination and maintenance of such systems shall be by a qualified person.\n\n(b) A record of the functional test conducted in accordance with paragraph (a) of this section shall be maintained by the operator and kept for a period of one year.\n\n(c) Sensors shall be calibrated in accordance with the manufacturer's calibration instructions at intervals not to exceed 31 days. A record of the sensor calibrations shall be maintained by the operator and kept for a period of one year.\n\n[73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1914","heading":"Maintenance of diesel-powered equipment.","id":"75.1914","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1914","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Diesel-powered equipment shall be maintained in approved and safe condition or removed from service.\n\n(b) Maintenance and repairs of approved features and those features required by §§ 75.1909 and 75.1910 on diesel-powered equipment shall be made only by a person qualified under § 75.1915.\n\n(c) The water scrubber system on diesel-powered equipment shall be drained and flushed, by a person who is trained to perform this task, at least once on each shift in which the equipment is operated.\n\n(d) The intake air filter on diesel-powered equipment shall be replaced or serviced, by a person who is trained to perform this task, when the intake air pressure drop device so indicates or when the engine manufacturer's maximum allowable air pressure drop level is exceeded.\n\n(e) Mobile diesel-powered equipment that is to be used during a shift shall be visually examined by the equipment operator before being placed in operation. Equipment defects affecting safety shall be reported promptly to the mine operator.\n\n(f) All diesel-powered equipment shall be examined and tested weekly by a person qualified under § 75.1915.\n\n(1) Examinations and tests shall be conducted in accordance with approved checklists and manufacturers' maintenance manuals.\n\n(2) Persons performing weekly examinations and tests of diesel-powered equipment under this paragraph shall make a record when the equipment is not in approved or safe condition. The record shall include the equipment that is not in approved or safe condition, the defect found, and the corrective action taken.\n\n(g) Undiluted exhaust emissions of diesel engines in diesel-powered equipment approved under part 36 and heavy-duty nonpermissible diesel-powered equipment as defined in § 75.1908(a) in use in underground coal mines shall be tested and evaluated weekly by a person who is trained to perform this task. The mine operator shall develop and implement written standard operating procedures for such testing and evaluation that specify the following:\n\n(1) The method of achieving a repeatable loaded engine operating condition for each type of equipment;\n\n(2) Sampling and analytical methods (including calibration of instrumentation) that are capable of accurately detecting carbon monoxide in the expected concentrations;\n\n(3) The method of evaluation and interpretation of the results;\n\n(4) The concentration or changes in concentration of carbon monoxide that will indicate a change in engine performance. Carbon monoxide concentration shall not exceed 2500 parts per million; and\n\n(5) The maintenance of records necessary to track engine performance.\n\n(h) Recordkeeping. Records required by paragraphs (f)(2) and (g)(5) shall be—\n\n(1) Recorded in a secure book that is not susceptible to alteration, or recorded electronically in a computer system that is secure and not susceptible to alteration; and\n\n(2) Retained at a surface location at the mine for at least 1 year and made available for inspection by an authorized representative of the Secretary and by miners' representatives.\n\n(i) Diesel-powered equipment must be maintained in accordance with this part as of November 25, 1997.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1909","heading":"Nonpermissible diesel-powered equipment; design and performance requirements.","id":"75.1909","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1909","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Nonpermissible diesel-powered equipment, except for the special category of equipment under § 75.1908(d), must be equipped with the following features:\n\n(1) An engine approved under subpart E of part 7 of this title equipped with an air filter sized in accordance with the engine manufacturer's recommendations, and an air filter service indicator set in accordance with the engine manufacturer's recommendations;\n\n(2) At least one portable multipurpose dry chemical type (ABC) fire extinguisher listed or approved by a nationally recognized independent testing laboratory with a 10A:60B:C or higher rating. The fire extinguisher must be located within easy reach of the equipment operator and protected from damage;\n\n(3) A fuel system specifically designed for diesel fuel meeting the following requirements:\n\n(i) A fuel tank and fuel lines that do not leak;\n\n(ii) A fuel tank that is substantially constructed and protected against damage by collision;\n\n(iii) A vent opening that maintains atmospheric pressure in the fuel tank, and that is designed to prevent fuel from splashing out of the vent opening;\n\n(iv) A self-closing filler cap on the fuel tank;\n\n(v) The fuel tank, filler and vent must be located so that leaks or spillage during refueling will not contact hot surfaces;\n\n(vi) Fuel line piping must be either steel-wire reinforced; synthetic elastomer-covered hose suitable for use with diesel fuel that has been tested and has been determined to be fire-resistant by the manufacturer; or metal;\n\n(vii) Fuel line piping must be clamped;\n\n(viii) Primary fuel lines must be located so that fuel line leaks do not contact hot surfaces;\n\n(ix) The fuel lines must be separated from electrical wiring and protected from damage in ordinary use;\n\n(x) A manual shutoff valve must be installed in the fuel system as close as practicable to the tank; and\n\n(xi) A water separator and fuel filter(s) must be provided.\n\n(4) A sensor to monitor the temperature and provide a visual warning of an overheated cylinder head on air-cooled engines;\n\n(5) Guarding to protect fuel, hydraulic, and electric lines when such lines pass near rotating parts or in the event of shaft failure;\n\n(6) Hydraulic tanks, fillers, vents, and lines located to prevent spillage or leaks from contacting hot surfaces;\n\n(7) Reflectors or warning lights mounted on the equipment which can be readily seen in all directions;\n\n(8) A means to direct exhaust gas away from the equipment operator, persons on board the machine, and combustible machine components;\n\n(9) A means to prevent unintentional free and uncontrolled descent of personnel-elevating work platforms; and\n\n(10) A means to prevent the spray from ruptured hydraulic or lubricating oil lines from being ignited by contact with engine exhaust system component surfaces.\n\n(b) Self-propelled nonpermissible diesel-powered equipment must have the following features in addition to those in paragraph (a):\n\n(1) A means to ensure that no stored hydraulic energy that will cause machine articulation is available after the engine is shut down;\n\n(2) A neutral start feature which ensures that engine cranking torque will not be transmitted through the powertrain and cause machine movement on vehicles utilizing fluid power transmissions;\n\n(3) For machines with steering wheels, brake pedals, and accelerator pedals, controls which are of automobile orientation;\n\n(4) An audible warning device conveniently located near the equipment operator;\n\n(5) Lights provided and maintained on both ends of the equipment. Equipment normally operated in both directions must be equipped with headlights for both directions;\n\n(6) Service brakes that act on each wheel of the vehicle and that are designed such that failure of any single component, except the brake actuation pedal or other similar actuation device, must not result in a complete loss of service braking capability;\n\n(7) Service brakes that safely bring the fully loaded vehicle to a complete stop on the maximum grade on which it is operated; and\n\n(8) No device that traps a column of fluid to hold the brake in the applied position shall be installed in any brake system, unless the trapped column of fluid is released when the equipment operator is no longer in contact with the brake activation device.\n\n(c) Self-propelled nonpermissible heavy-duty diesel-powered equipment under § 75.1908(a), except rail-mounted equipment, shall be provided with a supplemental braking system that:\n\n(1) Engages automatically within 5 seconds of the shutdown of the engine;\n\n(2) Safely brings the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(3) Holds the equipment stationary, despite any contraction of brake parts, exhaustion of any nonmechanical source of energy, or leakage;\n\n(4) Releases only by a manual control that does not operate any other equipment function;\n\n(5) Has a means in the equipment operator's compartment to apply the brakes manually without shutting down the engine, and a means to release and reengage the brakes without the engine operating; and\n\n(6) Has a means to ensure that the supplemental braking system is released before the equipment can be trammed, and is designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(d) Self-propelled nonpermissible light-duty diesel-powered equipment under § 75.1908(b), except rail-mounted equipment, must be provided with a parking brake that holds the fully loaded equipment stationary on the maximum grade on which it is operated despite any contraction of the brake parts, exhaustion of any nonmechanical source of energy, or leakage.\n\n(e) The supplemental and park brake systems required by paragraphs (c) and (d) must be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n(f) Self-propelled personnel-elevating work platforms must be provided with a means to ensure that the parking braking system is released before the equipment can be trammed, and must be designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(g) Any nonpermissible equipment that discharges its exhaust directly into a return air course must be provided with a power package approved under subpart F of part 7 of this title.\n\n(h) Self-propelled nonpermissible heavy-duty diesel-powered equipment meeting the requirements of § 75.1908(a) must be provided with an automatic fire suppression system meeting the requirements of § 75.1911.\n\n(i) Self-propelled nonpermissible light-duty diesel-powered equipment meeting the requirements of § 75.1908(b) must be provided with an automatic or manual fire suppression system meeting the requirements of § 75.1911.\n\n(j) Nonpermissible equipment that is not self-propelled must have the following features in addition to those listed in paragraph (a):\n\n(1) A means to prevent inadvertent movement of the equipment when parked;\n\n(2) Safety chains or other suitable secondary connections on equipment that is being towed; and\n\n(3) An automatic fire suppression system meeting the requirements of § 75.1911.\n\n[61 FR 55527, Oct. 25, 1996; 62 FR 34641, June 27, 1997]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1103147","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}