{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1103141","name":"Mach #1 Mine","status":"Active","status_date":"2006-09-01","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IL","county":"Williamson","nearest_town":"Johnston City","operator_id":"0061803","operator_name":"Mach Mining LLC","controller_id":"0129681","controller_name":"Foresight Energy Labor LLC","district":"C08","office":"Marion IL Field Office","employees":231,"latitude":37.838889,"longitude":-88.831111},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":36251},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1103141","name":"Mach #1 Mine"},"operator":{"type":"operator","id":"0061803","name":"Mach Mining LLC"},"controller":{"type":"controller","id":"0129681","name":"Foresight Energy Labor LLC"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0055417","name":"Steelhead Development Company, LLC"},"object":{"type":"mine","id":"1103141","name":"Mach #1 Mine"},"validFrom":"2004-11-08","validTo":"2005-07-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|0055417|2004-11-08|2005-07-06"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C10294","name":"Chris  Cline"},"object":{"type":"mine","id":"1103141","name":"Mach #1 Mine"},"validFrom":"2004-11-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|C10294|2004-11-08|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C10294","name":"Chris  Cline"},"object":{"type":"operator","id":"0055417","name":"Steelhead Development Company, LLC"},"validFrom":"2004-11-08","validTo":"2005-07-06","current":false,"derived":true,"evidenceMineId":"1103141","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|0055417|2004-11-08|C10294|2004-11-08|81694"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0061803","name":"Mach Mining LLC"},"object":{"type":"mine","id":"1103141","name":"Mach #1 Mine"},"validFrom":"2005-07-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|0061803|2005-07-07|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C10294","name":"Chris  Cline"},"object":{"type":"mine","id":"1103141","name":"Mach #1 Mine"},"validFrom":"2005-07-07","validTo":"2006-04-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|C10294|2005-07-07|2006-04-19"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C10294","name":"Chris  Cline"},"object":{"type":"operator","id":"0061803","name":"Mach Mining LLC"},"validFrom":"2005-07-07","validTo":"2006-04-19","current":false,"derived":true,"evidenceMineId":"1103141","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|0061803|2005-07-07|C10294|2005-07-07|81695"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0059869","name":"Foresight Energy/ Murray Energy et al"},"object":{"type":"mine","id":"1103141","name":"Mach #1 Mine"},"validFrom":"2006-04-20","validTo":"2016-07-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|0059869|2006-04-20|2016-07-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0059869","name":"Foresight Energy/ Murray Energy et al"},"object":{"type":"operator","id":"0061803","name":"Mach Mining LLC"},"validFrom":"2006-04-20","validTo":"2016-07-31","current":false,"derived":true,"evidenceMineId":"1103141","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|0061803|2005-07-07|0059869|2006-04-20|7970"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0059869","name":"Coalfield Transport Inc et al"},"object":{"type":"operator","id":"0061803","name":"Mach Mining LLC"},"validFrom":"2006-04-20","validTo":"2016-07-31","current":false,"derived":true,"evidenceMineId":"1103141","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|0061803|2005-07-07|0059869|2006-04-20|7971"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0129681","name":"Foresight Energy Labor LLC"},"object":{"type":"mine","id":"1103141","name":"Mach #1 Mine"},"validFrom":"2016-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|0129681|2016-08-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0129681","name":"Foresight Energy Labor LLC"},"object":{"type":"operator","id":"0061803","name":"Mach Mining LLC"},"validFrom":"2016-08-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1103141","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1103141|0061803|2005-07-07|0129681|2016-08-01|26012"}}],"coverage":{"historyRecords":5,"edgeCount":11,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":546,"firstDate":"2005-11-28","lastDate":"2026-09-17","metrics":{"daysLost":18333,"injuries":458,"fatalities":0,"recentRows":253,"restrictedDays":140,"contractorRecords":50},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"254734","DOCUMENT_NO":"220262660012","ACCIDENT_DT":"09/17/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Supply man, Supply worker, Nipper","NO_INJURIES":"1","NARRATIVE":"I.E. strained EE's back while hanging a bolter cable","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"78370","DOCUMENT_NO":"220262640023","ACCIDENT_DT":"09/17/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"1","NARRATIVE":"I.E. was setting bits on the shear when a rock fell out and struck them on the back.","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"134080","DOCUMENT_NO":"220262600025","ACCIDENT_DT":"09/10/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"I.E. bent over to drag a tube and felt something pop in their back.","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"259076","DOCUMENT_NO":"220262510013","ACCIDENT_DT":"09/04/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"At approximately 10:35 an unplanned roof fall occurred at xc 64 between entries 5 and 6 along the N.E. Mains travel road.","sourceDate":"2026-09-04"},{"SOURCE_ROW_NUMBER":"112559","DOCUMENT_NO":"220262430064","ACCIDENT_DT":"08/28/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"At approximately 1:55 am a roof fall occurred in xc 3 number 4 entry on District 6","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"61075","DOCUMENT_NO":"220262440008","ACCIDENT_DT":"08/28/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","NARRATIVE":"employee was working on a 3 inch dewatering pump. when attempting to remove the plastic priming bowl plug it broke loose and allowed the water, sludge and steam to spray on the employee. Covering EE's right arm and face. employee was taken to emergency room for treatment. 2nd degree burns","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"160081","DOCUMENT_NO":"220262430063","ACCIDENT_DT":"08/24/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"I.E. cribbed up the stageloader crusher and began cutting out a dog bone. Before the cut was complete, the crusher shifted, causing the I.E. to move out of the way. During the movement the I.E. struck their knee against the crusher motor resulting in a contusion.","sourceDate":"2026-08-24"},{"SOURCE_ROW_NUMBER":"177303","DOCUMENT_NO":"220262320013","ACCIDENT_DT":"08/18/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"I.E. was helping take down water pipe and was hit by the pipe when they dropped it to the ground.","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"22448","DOCUMENT_NO":"220262320012","ACCIDENT_DT":"08/18/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While handling a replacement cutting edge for a D11 dozer, the I.E. pinched their right little finger between the replacement cutting edge and another cutting edge already on the ground.","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"164399","DOCUMENT_NO":"220262640025","ACCIDENT_DT":"08/17/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Tractor operator","NO_INJURIES":"1","NARRATIVE":"I.E. was attempting to remove a 2x4 that was holding the mesh back after bolting on the longwall face when it suddenly broke causing them to twist and fall onto their right knee. I.E. was not taken off work until 9-11-2026.","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"43871","DOCUMENT_NO":"220262220020","ACCIDENT_DT":"08/03/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"I.E. was raking out coal from under the belt when they turned their head and was hit above left eye with a shovel being used by a co-worker.","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"78369","DOCUMENT_NO":"220262110018","ACCIDENT_DT":"07/28/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"I.E. was trying to pry rocks off of the tail drive when a rock fell between the shields and smashed EE's right ring finger.","sourceDate":"2026-07-28"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-09-01","lastDate":"2006-09-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":5340,"firstDate":"2005-11-16","lastDate":"2026-08-17","metrics":{"ss":1175,"delinquent":5192,"recentRows":1377,"paidPenalty":3861579.79,"proposedPenalty":5660591.6,"currentAssessment":4136574.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3032800","VIOLATION_NO":"5014256","ISSUE_DT":"08/17/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"2937107","VIOLATION_NO":"9789746","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"75.1103-4(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2937106","VIOLATION_NO":"9789745","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1818.00","CURRENT_ASSESSMENT_AMT":"1818.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2937074","VIOLATION_NO":"5012117","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2937105","VIOLATION_NO":"9789744","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"2937104","VIOLATION_NO":"9789743","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"2937103","VIOLATION_NO":"9789739","ISSUE_DT":"08/07/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-07"},{"SOURCE_ROW_NUMBER":"2937102","VIOLATION_NO":"9789738","ISSUE_DT":"08/07/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-07"},{"SOURCE_ROW_NUMBER":"2937112","VIOLATION_NO":"9789737","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.342(c)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"465.00","CURRENT_ASSESSMENT_AMT":"465.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2937085","VIOLATION_NO":"5016434","ISSUE_DT":"08/05/2026","CFR_STANDARD_CD":"75.206(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2937068","VIOLATION_NO":"5011162","ISSUE_DT":"08/05/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2937067","VIOLATION_NO":"5011161","ISSUE_DT":"08/05/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-05"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1387,"firstDate":"2007-06-21","lastDate":"2026-10-06","metrics":{"appeals":13,"decisions":1336,"recentRows":229,"decisionPenalty":2177894.8,"originalPenalty":3861335.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"463676","VIOLATION_NO":"5012455","DOCKET_NO":"LAKE 2026-0115","DECISION_DT":"10/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"245.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"462886","VIOLATION_NO":"5012454","DOCKET_NO":"LAKE 2026-0115","DECISION_DT":"10/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"504.00","DECISION_PENALTY_AMT":"209.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"462550","VIOLATION_NO":"5012063","DOCKET_NO":"LAKE 2026-0115","DECISION_DT":"10/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"366.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"462549","VIOLATION_NO":"5011992","DOCKET_NO":"LAKE 2026-0115","DECISION_DT":"10/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1219.00","DECISION_PENALTY_AMT":"549.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"169338","VIOLATION_NO":"5011990","DOCKET_NO":"LAKE 2026-0115","DECISION_DT":"10/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1818.00","DECISION_PENALTY_AMT":"818.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"169151","VIOLATION_NO":"5011661","DOCKET_NO":"LAKE 2026-0115","DECISION_DT":"10/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1219.00","DECISION_PENALTY_AMT":"549.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"168714","VIOLATION_NO":"5011994","DOCKET_NO":"LAKE 2026-0115","DECISION_DT":"10/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1431.00","DECISION_PENALTY_AMT":"642.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"168713","VIOLATION_NO":"5011102","DOCKET_NO":"LAKE 2026-0115","DECISION_DT":"10/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"366.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"462761","VIOLATION_NO":"9789889","DOCKET_NO":"LAKE 2026-0084","DECISION_DT":"08/14/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4383.00","DECISION_PENALTY_AMT":"1968.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-14"},{"SOURCE_ROW_NUMBER":"462760","VIOLATION_NO":"9789649","DOCKET_NO":"LAKE 2026-0084","DECISION_DT":"08/14/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1679.00","DECISION_PENALTY_AMT":"755.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-14"},{"SOURCE_ROW_NUMBER":"462278","VIOLATION_NO":"9789650","DOCKET_NO":"LAKE 2026-0084","DECISION_DT":"08/14/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1679.00","DECISION_PENALTY_AMT":"755.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-14"},{"SOURCE_ROW_NUMBER":"461625","VIOLATION_NO":"9789893","DOCKET_NO":"LAKE 2026-0084","DECISION_DT":"08/14/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1320.00","DECISION_PENALTY_AMT":"592.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-14"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":12240,"firstDate":"2001-04-29","lastDate":"2026-10-07","metrics":{"recentRows":5643,"cpdmSamples":8680,"voidSamples":2506,"validSamples":9734,"maxConcentration":462346,"concentrationTotal":470521.77},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2944441","SMP_TAKEN_DT":"10/7/2026","CONC":".843","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2944403","SMP_TAKEN_DT":"10/7/2026","CONC":".621","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2517890","SMP_TAKEN_DT":"10/7/2026","CONC":"1.155","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2432799","SMP_TAKEN_DT":"10/7/2026","CONC":".846","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2431944","SMP_TAKEN_DT":"10/7/2026","CONC":".67","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2347541","SMP_TAKEN_DT":"10/7/2026","CONC":".374","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2347482","SMP_TAKEN_DT":"10/7/2026","CONC":".701","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2944150","SMP_TAKEN_DT":"10/6/2026","CONC":".546","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2858781","SMP_TAKEN_DT":"10/6/2026","CONC":".993","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2773307","SMP_TAKEN_DT":"10/6/2026","CONC":".976","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2773188","SMP_TAKEN_DT":"10/6/2026","CONC":".448","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2773144","SMP_TAKEN_DT":"10/6/2026","CONC":".406","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":143,"firstDate":"2006-03-15","lastDate":"2026-03-18","metrics":{"linkedIssuances":143},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1376,"firstDate":"2006-03-02","lastDate":"2026-07-28","metrics":{"decisions":1324,"ssChanged":284,"recentRows":268,"decisionPenalty":2125828.8,"proposedPenalty":4029912},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"224756","CITATION_NO":"9789731","CITATION_ISSUE_DT":"07/28/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2133.00","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"224109","CITATION_NO":"9789729","CITATION_ISSUE_DT":"07/24/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3736.00","sourceDate":"2026-07-24"},{"SOURCE_ROW_NUMBER":"450484","CITATION_NO":"5017106","CITATION_ISSUE_DT":"07/21/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"75.321(a)(2)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"642.00","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"53901","CITATION_NO":"9789722","CITATION_ISSUE_DT":"07/17/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"75.1600-3(a)(2)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"398.00","sourceDate":"2026-07-17"},{"SOURCE_ROW_NUMBER":"393122","CITATION_NO":"5011155","CITATION_ISSUE_DT":"07/15/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"77.1103(d)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"193.00","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"111578","CITATION_NO":"5011154","CITATION_ISSUE_DT":"07/15/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"77.1301(c)(11)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"193.00","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"111326","CITATION_NO":"5011153","CITATION_ISSUE_DT":"07/15/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"77.1303(d)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"642.00","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"450485","CITATION_NO":"5017102","CITATION_ISSUE_DT":"07/13/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"75.364(b)(8)(ii)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"697.00","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"280058","CITATION_NO":"5017101","CITATION_ISSUE_DT":"07/13/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1037.00","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"393928","CITATION_NO":"5016194","CITATION_ISSUE_DT":"07/10/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"75.1909(a)(2)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1431.00","sourceDate":"2026-07-10"},{"SOURCE_ROW_NUMBER":"280869","CITATION_NO":"5016199","CITATION_ISSUE_DT":"07/10/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"75.1914(f)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1431.00","sourceDate":"2026-07-10"},{"SOURCE_ROW_NUMBER":"280057","CITATION_NO":"5016195","CITATION_ISSUE_DT":"07/10/2026","DOCKET_NO":"LAKE 2026-0217","CFR_STANDARD_CODE":"75.1910(f)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1431.00","sourceDate":"2026-07-10"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":5276,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":28,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":1140,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":28,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"2004-11-08","lastDate":"2005-07-07","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":1528,"firstDate":"2005-10-11","lastDate":"2026-10-07","metrics":{"inspectors":2473,"recentRows":543,"onSiteHours":43498,"inspectionHours":65700.75,"inspectionSamples":4373},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"251092","EVENT_NO":"F03ABAC","INSPECTION_BEGIN_DT":"10/07/2026","INSPECTION_END_DT":"10/07/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"714200","EVENT_NO":"F03ABAB","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"29.75","SUM_TOTAL_ON_SITE_HOURS":"19.5","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"932494","EVENT_NO":"F00C540","INSPECTION_BEGIN_DT":"09/30/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"380975","EVENT_NO":"F00C53F","INSPECTION_BEGIN_DT":"09/29/2026","INSPECTION_END_DT":"09/29/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"1026137","EVENT_NO":"F03F88D","INSPECTION_BEGIN_DT":"09/23/2026","INSPECTION_END_DT":"09/23/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.25","SUM_TOTAL_ON_SITE_HOURS":"6.75","sourceDate":"2026-09-23"},{"SOURCE_ROW_NUMBER":"3345","EVENT_NO":"F013326","INSPECTION_BEGIN_DT":"09/16/2026","INSPECTION_END_DT":"09/16/2026","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"1013253","EVENT_NO":"F03F88C","INSPECTION_BEGIN_DT":"09/15/2026","INSPECTION_END_DT":"09/15/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"7.25","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"354158","EVENT_NO":"F0095BD","INSPECTION_BEGIN_DT":"09/14/2026","INSPECTION_END_DT":"09/14/2026","ACTIVITY_CODE":"E18","ACTIVITY":"Shaft, Slope or Major Construction Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"598890","EVENT_NO":"F00C53E","INSPECTION_BEGIN_DT":"09/10/2026","INSPECTION_END_DT":"09/10/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"739559","EVENT_NO":"F00C53D","INSPECTION_BEGIN_DT":"09/08/2026","INSPECTION_END_DT":"09/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"243086","EVENT_NO":"F00C53C","INSPECTION_BEGIN_DT":"09/04/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"36.5","SUM_TOTAL_ON_SITE_HOURS":"25.5","sourceDate":"2026-09-04"},{"SOURCE_ROW_NUMBER":"565508","EVENT_NO":"F00C53B","INSPECTION_BEGIN_DT":"09/01/2026","INSPECTION_END_DT":"09/01/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":332,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":172163,"employees":294,"production":1573316},"2026-Q1":{"hours":168387,"employees":255,"production":1881900},"2025-Q4":{"hours":130477,"employees":257,"production":1640955},"2025-Q3":{"hours":135849,"employees":268,"production":1751982},"2025-Q2":{"hours":156892,"employees":231,"production":1141830},"2025-Q1":{"hours":178858,"employees":324,"production":1966332},"2024-Q4":{"hours":132336,"employees":268,"production":1663009},"2024-Q3":{"hours":161860,"employees":266,"production":1721926},"2024-Q2":{"hours":166760,"employees":281,"production":1062958},"2024-Q1":{"hours":170361,"employees":274,"production":1965781},"2023-Q4":{"hours":126077,"employees":244,"production":1401508},"2023-Q3":{"hours":152627,"employees":260,"production":1924748}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":86,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":533107,"employees":215,"production":6335835},"2018":{"hours":549386,"employees":228,"production":6887728},"2019":{"hours":518986,"employees":231,"production":5174361},"2020":{"hours":360952,"employees":179,"production":3841668},"2021":{"hours":500139,"employees":228,"production":6713341},"2022":{"hours":500625,"employees":215,"production":7715724},"2023":{"hours":554837,"employees":242,"production":7037074},"2024":{"hours":631317,"employees":273,"production":6413674},"2025":{"hours":602076,"employees":271,"production":6501099},"2026":{"hours":340550,"employees":276,"production":3455216}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":596,"firstDate":"2007-10-16","lastDate":"2026-06-18","metrics":{"recentRows":202,"doseOver100":148,"actDoseTotal":44570,"pelDoseTotal":32594},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"23530","EVENT_NO":"F016AF8","SURVEY_DATE":"06/18/2026","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"38","ACT_DOSE_85":"38","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2026-06-18"},{"SOURCE_ROW_NUMBER":"23529","EVENT_NO":"F016AF8","SURVEY_DATE":"06/18/2026","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"38","ACT_DOSE_85":"105","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2026-06-18"},{"SOURCE_ROW_NUMBER":"23528","EVENT_NO":"F016AF8","SURVEY_DATE":"06/18/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"31","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2026-06-18"},{"SOURCE_ROW_NUMBER":"23527","EVENT_NO":"F016AF8","SURVEY_DATE":"06/18/2026","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"42","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2026-06-18"},{"SOURCE_ROW_NUMBER":"23526","EVENT_NO":"F016AF8","SURVEY_DATE":"06/18/2026","OCCUPATION_CD_DESC":"ROTARY BUCKET EXCAVATOR OPERATOR","MACHINE_CD":"35","ACT_DOSE_85":"15","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2026-06-18"},{"SOURCE_ROW_NUMBER":"23525","EVENT_NO":"F016AF8","SURVEY_DATE":"06/11/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"74","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"23524","EVENT_NO":"F016AF8","SURVEY_DATE":"06/11/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","ACT_DOSE_85":"96","PEL_DOSE_90":"88","SURVEY_TYPE":"I","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"23523","EVENT_NO":"F016AF8","SURVEY_DATE":"06/11/2026","OCCUPATION_CD_DESC":"OUTSIDE FOREMAN","MACHINE_CD":"40","ACT_DOSE_85":"19","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"23522","EVENT_NO":"F016AF8","SURVEY_DATE":"06/11/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","ACT_DOSE_85":"117","PEL_DOSE_90":"102","SURVEY_TYPE":"I","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"23521","EVENT_NO":"F016AF8","SURVEY_DATE":"06/11/2026","OCCUPATION_CD_DESC":"WATER TRUCK OPERATOR","MACHINE_CD":"39","ACT_DOSE_85":"41","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"23450","EVENT_NO":"7023426","SURVEY_DATE":"12/09/2025","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"59","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"23449","EVENT_NO":"7023426","SURVEY_DATE":"12/09/2025","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"114","PEL_DOSE_90":"97","SURVEY_TYPE":"I","sourceDate":"2025-12-09"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":785,"firstDate":"2007-02-06","lastDate":"2026-09-17","metrics":{"recentRows":395,"voidSamples":41,"maxQuartzPct":10.9,"validSamples":744,"quartzPctTotal":3064.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"144739","CASSETTE_NO":"58591136","SAMPLE_DT":"09/17/2026","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"64234","CASSETTE_NO":"58591386","SAMPLE_DT":"09/17/2026","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"23","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"49239","CASSETTE_NO":"58591024","SAMPLE_DT":"09/17/2026","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"28","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"2060","CASSETTE_NO":"58590845","SAMPLE_DT":"09/17/2026","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"162423","CASSETTE_NO":"58591052","SAMPLE_DT":"09/15/2026","QUARTZ_PCT":"02.4","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"123048","CASSETTE_NO":"58591163","SAMPLE_DT":"09/15/2026","QUARTZ_PCT":"04.3","QUARTZ_MICROGRAMS":"46","OCC_CODE_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"74005","CASSETTE_NO":"58591036","SAMPLE_DT":"09/15/2026","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"13","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"37664","CASSETTE_NO":"58591143","SAMPLE_DT":"09/15/2026","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"20917","CASSETTE_NO":"58591043","SAMPLE_DT":"09/15/2026","QUARTZ_PCT":"02.4","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"HEADGATE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"123915","CASSETTE_NO":"58590850","SAMPLE_DT":"08/06/2026","QUARTZ_PCT":"03.4","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"84255","CASSETTE_NO":"58590841","SAMPLE_DT":"08/06/2026","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"79226","CASSETTE_NO":"58590853","SAMPLE_DT":"08/06/2026","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-06"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":5469,"firstDate":"2005-11-16","lastDate":"2026-10-08","metrics":{"ss":1187,"amountDue":4136574.3,"contested":237,"amountPaid":3861579.79,"recentRows":1431,"section104d":20,"unterminated":7,"proposedPenalty":5660591.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"536406","VIOLATION_NO":"5016965","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"536677","VIOLATION_NO":"5016964","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"536676","VIOLATION_NO":"5016963","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"536399","VIOLATION_NO":"5012121","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"77.205(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"536405","VIOLATION_NO":"5016962","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"536404","VIOLATION_NO":"5016961","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"536403","VIOLATION_NO":"5016960","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"536402","VIOLATION_NO":"5016959","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"536401","VIOLATION_NO":"5016958","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"N","PART_SECTION":"75.1107-9(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"536400","VIOLATION_NO":"5016957","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"535830","VIOLATION_NO":"9789756","VIOLATION_ISSUE_DT":"09/29/2026","SIG_SUB":"N","PART_SECTION":"75.1732(d)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/29/2026","CONTESTED_IND":"N","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"535829","VIOLATION_NO":"9789755","VIOLATION_ISSUE_DT":"09/29/2026","SIG_SUB":"N","PART_SECTION":"75.362(d)(3)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/29/2026","CONTESTED_IND":"N","sourceDate":"2026-09-29"}]}],"safety":{"href":"/api/v1/mines/1103141/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1103141/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":273,"companyType":"Operating Subsidiary","components":[{"averageEmployees":273,"laborHours":631317,"mineType":"Underground","productionTons":6413674}],"county":"Williamson","laborHours":631317,"mineName":"Mach #1 Mine","mineType":"Underground","mshaId":"1103141","operatingAddress":"P.O. Box 300, Johnston City, IL 62951","operatingCompany":"Mach Mining Llc","operationType":"Mine and Preparation Plant","productionTons":6413674,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Illinois","status":"Active","supplyRegion":"Illinois Basin","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-9","heading":"Dry chemical devices; capacity; minimum requirements.","id":"75.1107-9","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-9","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Dry chemical fire extinguishing systems used on underground equipment shall be of the multipurpose powder-type and shall include the following:\n\n(1) The system including all hose and nozzles shall be protected against the entrance of moisture, dust, or dirt;\n\n(2) The system shall be guarded against damage during operation of the equipment protected;\n\n(3) Hose and pipe shall be as short as possible; the distance between the chemical container and furthest nozzle shall not exceed 50 feet;\n\n(4) Hose, piping, and fittings between the actuator and the chemical container shall have a bursting pressure of 500 pounds per square inch (gage) or higher; the hose, piping, and fittings between the chemical container and the nozzles shall have a bursting pressure of 300 pounds per square inch (gage) or higher and\n\n(5) The system shall discharge in 1 minute or less, for quantities less than 50 pounds (nominal) 1 and in less than 2 minutes for quantities more than 50 pounds;\n\n1 Many dry chemical systems were originally designed for sodium bicarbonate before all-purpose chemical (ammonium phosphate) was shown to be more effective. Sodium bicarbonate is denser than ammonium phosphate; hence, for example, a 50-pound system designed for the sodium bicarbonate will hold slightly more by weight than all-purpose dry chemical (ammonium phosphate) by weight. The word “nominal” is used in § 75.1107-9 to express the approximate weight in pounds of all-purpose dry chemical.\n\n(b) On unattended underground equipment, the number of pounds of dry chemical employed by the system shall be not less than 1 pound per square foot of top surface area of the equipment; however, the minimum amount in any system shall be 20 pounds (nominal). The discharge shall be directed into and on potentially hazardous locations of the equipment.\n\n(c) On attended underground equipment, the number of pounds (nominal) employed by the system shall equal 5 times the total number of hazardous locations; however, the minimum amount in any system shall not be less than the following, except that systems on haulage vehicles installed prior to the effective date of this section may contain 20 pounds (nominal).\n\nType of equipment Dry chemical pounds (nominal) (1) Cutting machines 40 (2) Continuous miners 40 (3) Haulage vehicles 30 (4) All other attended equipment 20\n\n(d) The amount of dry chemical discharged into the cable reel compartments of attended underground equipment shall be approximately 25 percent of the total amount required to be discharged by the system; however, the quantity discharged into cable reel compartments need not exceed 10 pounds.\n\n[37 FR 15302, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1732","heading":"Proximity detection systems.","id":"75.1732","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1732","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"Operators must install proximity detection systems on certain mobile machines.\n\n(a) Machines covered. Operators must equip continuous mining machines, except full-face continuous mining machines, with proximity detection systems by the following dates. For proximity detection systems with miner-wearable components, the mine operator must provide a miner-wearable component to be worn by each miner on the working section by the following dates.\n\n(1) Continuous mining machines manufactured after March 16, 2015 must meet the requirements in this section no later than November 16, 2015. These machines must meet the requirements in this section when placed in service with a proximity detection system.\n\n(2) Continuous mining machines manufactured and equipped with a proximity detection system on or before March 16, 2015 must meet the requirements in this section no later than September 16, 2016.\n\n(3) Continuous mining machines manufactured and not equipped with a proximity detection system on or before March 16, 2015 must meet the requirements in this section no later than March 16, 2018. These machines must meet the requirements in this section when placed in service with a proximity detection system.\n\n(b) Requirements for a proximity detection system. A proximity detection system includes machine-mounted components and miner-wearable components. The system must:\n\n(1) Cause a machine, which is tramming from place-to-place or repositioning, to stop before contacting a miner except for a miner who is in the on-board operator's compartment;\n\n(2) Provide an audible and visual warning signal on the miner-wearable component and a visual warning signal on the machine that alert miners before the system causes a machine to stop. These warning signals must be distinguishable from other signals;\n\n(3) Provide a visual signal on the machine that indicates the machine-mounted components are functioning properly;\n\n(4) Prevent movement of the machine if any machine-mounted component of the system is not functioning properly. However, a system with any machine-mounted component that is not functioning properly may allow machine movement if it provides an audible or visual warning signal, distinguishable from other signals, during movement. Such movement is permitted only for purposes of relocating the machine from an unsafe location for repair;\n\n(5) Be installed to prevent interference that adversely affects performance of any electrical system; and\n\n(6) Be installed and maintained in proper operating condition by a person trained in the installation and maintenance of the system.\n\n(c) Proximity detection system checks. Operators must:\n\n(1) Designate a person who must perform a check of machine-mounted components of the proximity detection system to verify that components are intact, that the system is functioning properly, and take action to correct defects—\n\n(i) At the beginning of each shift when the machine is to be used; or\n\n(ii) Immediately prior to the time the machine is to be operated if not in use at the beginning of a shift; or\n\n(iii) Within 1 hour of a shift change if the shift change occurs without an interruption in production.\n\n(2) Check for proper operation of miner-wearable components at the beginning of each shift that the components are to be used and correct defects before the components are used.\n\n(d) Certifications and records. The operator must make and retain certifications and records as follows:\n\n(1) At the completion of the check of machine-mounted components required under paragraph (c)(1) of this section, a certified person under § 75.100 must certify by initials, date, and time that the check was conducted. Defects found as a result of the check, including corrective actions and dates of corrective actions, must be recorded before the end of the shift;\n\n(2) Make a record of the defects found as a result of the check of miner-wearable components required under paragraph (c)(2) of this section, including corrective actions and dates of corrective actions;\n\n(3) Make a record of the persons trained in the installation and maintenance of proximity detection systems required under paragraph (b)(6) of this section;\n\n(4) Maintain records in a secure book or electronically in a secure computer system not susceptible to alteration; and\n\n(5) Retain records for at least one year and make them available for inspection by authorized representatives of the Secretary and representatives of miners.\n\n[80 FR 2202, Jan. 15, 2015]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1103141","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}