{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1102236","name":"Crown II Mine","status":"Abandoned and Sealed","status_date":"2017-09-07","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IL","county":"Macoupin","nearest_town":"31Virden","operator_id":"0083144","operator_name":"Springfield Coal Company LLC","controller_id":"0119761","controller_name":"Jeffrey A  Haycraft","district":"C08","office":"Litchfield IL Field Office","employees":0,"latitude":39.478333,"longitude":-89.731389},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":7934},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1102236","name":"Crown II Mine"},"operator":{"type":"operator","id":"0083144","name":"Springfield Coal Company LLC"},"controller":{"type":"controller","id":"0119761","name":"Jeffrey A  Haycraft"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01339","name":"General Dynamics Corp"},"object":{"type":"mine","id":"1102236","name":"Crown II Mine"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1102236|C01339|1950-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P01631","name":"Freeman United Coal Mining Company"},"object":{"type":"mine","id":"1102236","name":"Crown II Mine"},"validFrom":"1974-07-03","validTo":"2007-08-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1102236|P01631|1974-07-03|2007-08-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01339","name":"General Dynamics Corp"},"object":{"type":"operator","id":"P01631","name":"Freeman United Coal Mining Company"},"validFrom":"1974-07-03","validTo":"2007-08-31","current":false,"derived":true,"evidenceMineId":"1102236","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1102236|P01631|1974-07-03|C01339|1950-01-01|53687"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0083144","name":"Springfield Coal Company LLC"},"object":{"type":"mine","id":"1102236","name":"Crown II Mine"},"validFrom":"2007-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1102236|0083144|2007-09-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0069839","name":"Brian J  Veldhuizen et al"},"object":{"type":"mine","id":"1102236","name":"Crown II Mine"},"validFrom":"2007-09-01","validTo":"2015-08-10","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1102236|0069839|2007-09-01|2015-08-10"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0069839","name":"Brian J  Veldhuizen et al"},"object":{"type":"operator","id":"0083144","name":"Springfield Coal Company LLC"},"validFrom":"2007-09-01","validTo":"2015-08-10","current":false,"derived":true,"evidenceMineId":"1102236","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1102236|0083144|2007-09-01|0069839|2007-09-01|9981"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0119761","name":"Jeffrey A  Haycraft"},"object":{"type":"mine","id":"1102236","name":"Crown II Mine"},"validFrom":"2015-08-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1102236|0119761|2015-08-11|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0119761","name":"Jeffrey A  Haycraft"},"object":{"type":"operator","id":"0083144","name":"Springfield Coal Company LLC"},"validFrom":"2015-08-11","validTo":null,"current":true,"derived":true,"evidenceMineId":"1102236","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1102236|0083144|2007-09-01|0119761|2015-08-11|23313"}}],"coverage":{"historyRecords":3,"edgeCount":8,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":302,"firstDate":"2000-01-17","lastDate":"2011-12-07","metrics":{"daysLost":4154,"injuries":132,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"155683","DOCUMENT_NO":"220113490017","ACCIDENT_DT":"12/07/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"while torching/cutting feeder chain during demolition at Crown II mine prep plant, chain struck worker on the hardhat causing slight laceration.","sourceDate":"2011-12-07"},{"SOURCE_ROW_NUMBER":"211576","DOCUMENT_NO":"220073510052","ACCIDENT_DT":"12/11/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the 6th east, #42 crosscut, #11 entry. The fall was 18' long, 18' wide & 8' high. The area was bolted with 8' tension rebar bolts. The fall didn't affect ventilation, travel, damage equipment or cause any injury. No one was required to work or travel in this entry.","sourceDate":"2007-12-11"},{"SOURCE_ROW_NUMBER":"147089","DOCUMENT_NO":"220073440044","ACCIDENT_DT":"11/27/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the 6 ep, #74 crosscut, #10 entry. The fall was 18' wide, 18' long & 9 high. The area was bolted with 8' point anchor bolts. The fall didn't affect ventilation, block travel, damage equipment, or cause any injury.","sourceDate":"2007-11-27"},{"SOURCE_ROW_NUMBER":"18001","DOCUMENT_NO":"220073300028","ACCIDENT_DT":"11/20/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in 3ssm, #4 & #5 entries at 21 crosscut, the fall was 80' wide & 12' high. The area was bolted with 6' to 8' point anchor bolts. The fall didn't affected ventilation, traveling damage equipment or cause ant injury.","sourceDate":"2007-11-20"},{"SOURCE_ROW_NUMBER":"121089","DOCUMENT_NO":"220073120039","ACCIDENT_DT":"10/30/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the 3NSM, #5 entry, #12 crosscut. The fall was 20' long, 30' wide, and 10' high. The fall didn't affect ventilation, travel, damage equipment, or cause injury. The area was bolted with 8' & 10' point anchor bolts.","sourceDate":"2007-10-30"},{"SOURCE_ROW_NUMBER":"228847","DOCUMENT_NO":"220072880066","ACCIDENT_DT":"10/09/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the 6th East Panel, #6 entry, #89 crosscut. The fall was 20' long, 40' wide, 9' high. The fall didn't affect travel, ventilation or cause injury. It did damage belt structure. No one is required to work or travel in this entry.","sourceDate":"2007-10-09"},{"SOURCE_ROW_NUMBER":"258982","DOCUMENT_NO":"220072830045","ACCIDENT_DT":"10/04/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the 3rd west at 1710' station, #3 entry. The fall was 30' long, 18' wide and 8.5' high. The area was bolted with 8' point anchor bolts. The fall didn't affect ventilation, cause injury, damage equipment or block travel. No one is required to work or travel in this entry.","sourceDate":"2007-10-04"},{"SOURCE_ROW_NUMBER":"155691","DOCUMENT_NO":"220072830044","ACCIDENT_DT":"10/01/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the 6th East, #6 Entry, at 83 Crosscut. The fall was 20' long, 20' wide, and 9' high. The area was bolted with 8' point anchor bolts. The fall didn't affect ventilation, cause injury, or block travel. It did damage some beltline. No one is required to work or travel in this entry.","sourceDate":"2007-10-01"},{"SOURCE_ROW_NUMBER":"164285","DOCUMENT_NO":"220072740067","ACCIDENT_DT":"09/25/2007","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Notification by MSHA of possibility of pneumoconiosis.","sourceDate":"2007-09-25"},{"SOURCE_ROW_NUMBER":"250358","DOCUMENT_NO":"220072680037","ACCIDENT_DT":"09/19/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Unintentional roof fall 6EP Panel #8 Entry footage 5,200 Feet. 20 ft long x 20 ft wide x 8 ft high. 4 Way Intersection. Bolted with 8 ft TR Bolts. Approx date of developement 7/17/07. This is a non-working section, affected no equipment or caused injury. Escapeway was not affected.","sourceDate":"2007-09-19"},{"SOURCE_ROW_NUMBER":"250357","DOCUMENT_NO":"220072610046","ACCIDENT_DT":"09/12/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the Main North belt entry between #13 & #14 crosscuts. The fall was 30' long, 18' wide, & 8' high. The area was bolted with 8' point anchor bolts. The fall didn't affect ventilation, cause injury or block travel. It did damage some belt line. No one is required to work or travel in this entry.","sourceDate":"2007-09-12"},{"SOURCE_ROW_NUMBER":"43786","DOCUMENT_NO":"220072420046","ACCIDENT_DT":"08/20/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unintentional roof fall 6th east panel #3 entry X cut #91. 25' long X 30' wide X 10' high. 4 way intersection bolted with 6' to 8' TR bolts. Approx date of development 7/25/07.","sourceDate":"2007-08-20"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2017-09-07","lastDate":"2017-09-07","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1620,"firstDate":"2000-01-04","lastDate":"2013-06-18","metrics":{"ss":635,"delinquent":1552,"recentRows":0,"paidPenalty":354851,"proposedPenalty":354851,"currentAssessment":354851},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1183504","VIOLATION_NO":"8443768","ISSUE_DT":"06/18/2013","CFR_STANDARD_CD":"77.106","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-18"},{"SOURCE_ROW_NUMBER":"1183503","VIOLATION_NO":"8443766","ISSUE_DT":"06/18/2013","CFR_STANDARD_CD":"40.4","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-18"},{"SOURCE_ROW_NUMBER":"1183502","VIOLATION_NO":"8443765","ISSUE_DT":"06/11/2013","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"1183501","VIOLATION_NO":"8443764","ISSUE_DT":"06/11/2013","CFR_STANDARD_CD":"77.1103(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"1205799","VIOLATION_NO":"8443263","ISSUE_DT":"12/12/2012","CFR_STANDARD_CD":"77.1109(e)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-12-12"},{"SOURCE_ROW_NUMBER":"1173221","VIOLATION_NO":"6676709","ISSUE_DT":"06/01/2010","CFR_STANDARD_CD":"77.900-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-06-01"},{"SOURCE_ROW_NUMBER":"1173220","VIOLATION_NO":"6676708","ISSUE_DT":"06/01/2010","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-06-01"},{"SOURCE_ROW_NUMBER":"1173219","VIOLATION_NO":"6676707","ISSUE_DT":"06/01/2010","CFR_STANDARD_CD":"77.800-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-06-01"},{"SOURCE_ROW_NUMBER":"1179071","VIOLATION_NO":"6676300","ISSUE_DT":"11/04/2009","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2000.00","CURRENT_ASSESSMENT_AMT":"2000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-11-04"},{"SOURCE_ROW_NUMBER":"1179070","VIOLATION_NO":"6676299","ISSUE_DT":"11/04/2009","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2000.00","CURRENT_ASSESSMENT_AMT":"2000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-11-04"},{"SOURCE_ROW_NUMBER":"1204510","VIOLATION_NO":"6675349","ISSUE_DT":"06/17/2009","CFR_STANDARD_CD":"77.200","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2341.00","CURRENT_ASSESSMENT_AMT":"2341.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-06-17"},{"SOURCE_ROW_NUMBER":"1204506","VIOLATION_NO":"6675344","ISSUE_DT":"05/15/2009","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-05-15"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":2026,"firstDate":"2000-01-05","lastDate":"2017-03-07","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":299,"validSamples":1727,"maxConcentration":21.979,"concentrationTotal":2414.533},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"699773","CASS_NUM":"58262801","SMP_TAKEN_DT":"3/7/2017","CONC":".033","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-03-07"},{"SOURCE_ROW_NUMBER":"373875","CASS_NUM":"58262892","SMP_TAKEN_DT":"3/7/2017","CONC":".011","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OUTSIDE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-03-07"},{"SOURCE_ROW_NUMBER":"1640532","CASS_NUM":"58268145","SMP_TAKEN_DT":"9/12/2016","CONC":".012","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-09-12"},{"SOURCE_ROW_NUMBER":"1067187","CASS_NUM":"58268068","SMP_TAKEN_DT":"9/12/2016","CONC":"0","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OUTSIDE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-09-12"},{"SOURCE_ROW_NUMBER":"551597","CASS_NUM":"58226882","SMP_TAKEN_DT":"3/17/2016","CONC":".015","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER/BLACKSMITH","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-03-17"},{"SOURCE_ROW_NUMBER":"155377","CASS_NUM":"58226892","SMP_TAKEN_DT":"3/17/2016","CONC":".021","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER/BLACKSMITH","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-03-17"},{"SOURCE_ROW_NUMBER":"152268","CASS_NUM":"51382149","SMP_TAKEN_DT":"9/24/2015","CONC":".078","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-09-24"},{"SOURCE_ROW_NUMBER":"1049497","CASS_NUM":"51381730","SMP_TAKEN_DT":"6/12/2015","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-06-12"},{"SOURCE_ROW_NUMBER":"484877","CASS_NUM":"58167777","SMP_TAKEN_DT":"6/2/2015","CONC":".016","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-06-02"},{"SOURCE_ROW_NUMBER":"1259905","CASS_NUM":"58167624","SMP_TAKEN_DT":"3/16/2015","CONC":".065","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-16"},{"SOURCE_ROW_NUMBER":"1217361","CASS_NUM":"51295245","SMP_TAKEN_DT":"3/10/2015","CONC":".018","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-10"},{"SOURCE_ROW_NUMBER":"283728","CASS_NUM":"51295235","SMP_TAKEN_DT":"12/16/2014","CONC":".041","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-16"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":9,"firstDate":"2001-04-24","lastDate":"2006-08-28","metrics":{"linkedIssuances":9},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1254,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":9,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":210,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":9,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1974-07-03","lastDate":"2007-09-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":388,"firstDate":"2000-01-03","lastDate":"2017-03-06","metrics":{"inspectors":517,"recentRows":0,"onSiteHours":13105.75,"inspectionHours":19754.5,"inspectionSamples":216},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"58201","EVENT_NO":"6455788","INSPECTION_BEGIN_DT":"03/06/2017","INSPECTION_END_DT":"03/09/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2017-03-06"},{"SOURCE_ROW_NUMBER":"713951","EVENT_NO":"4257259","INSPECTION_BEGIN_DT":"09/11/2016","INSPECTION_END_DT":"09/13/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15.25","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2016-09-11"},{"SOURCE_ROW_NUMBER":"140003","EVENT_NO":"4257247","INSPECTION_BEGIN_DT":"03/16/2016","INSPECTION_END_DT":"03/17/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2016-03-16"},{"SOURCE_ROW_NUMBER":"374681","EVENT_NO":"4257718","INSPECTION_BEGIN_DT":"01/20/2016","INSPECTION_END_DT":"01/20/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2016-01-20"},{"SOURCE_ROW_NUMBER":"538207","EVENT_NO":"4257707","INSPECTION_BEGIN_DT":"08/24/2015","INSPECTION_END_DT":"08/24/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2015-08-24"},{"SOURCE_ROW_NUMBER":"286637","EVENT_NO":"4256766","INSPECTION_BEGIN_DT":"06/02/2015","INSPECTION_END_DT":"06/04/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.5","SUM_TOTAL_ON_SITE_HOURS":"8.75","sourceDate":"2015-06-02"},{"SOURCE_ROW_NUMBER":"157163","EVENT_NO":"4248721","INSPECTION_BEGIN_DT":"03/16/2015","INSPECTION_END_DT":"03/16/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2015-03-16"},{"SOURCE_ROW_NUMBER":"884501","EVENT_NO":"4256891","INSPECTION_BEGIN_DT":"11/12/2014","INSPECTION_END_DT":"11/12/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2014-11-12"},{"SOURCE_ROW_NUMBER":"1114953","EVENT_NO":"4256881","INSPECTION_BEGIN_DT":"06/10/2014","INSPECTION_END_DT":"06/19/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2014-06-10"},{"SOURCE_ROW_NUMBER":"749667","EVENT_NO":"4256874","INSPECTION_BEGIN_DT":"12/18/2013","INSPECTION_END_DT":"12/23/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"18","sourceDate":"2013-12-18"},{"SOURCE_ROW_NUMBER":"1048941","EVENT_NO":"4248715","INSPECTION_BEGIN_DT":"07/11/2013","INSPECTION_END_DT":"07/11/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"207581","EVENT_NO":"4248714","INSPECTION_BEGIN_DT":"06/11/2013","INSPECTION_END_DT":"06/18/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"15.25","sourceDate":"2013-06-11"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":241,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017-Q3":{"hours":456,"employees":1,"production":0},"2017-Q2":{"hours":784,"employees":2,"production":0},"2017-Q1":{"hours":744,"employees":2,"production":0},"2016-Q4":{"hours":920,"employees":2,"production":0},"2016-Q3":{"hours":928,"employees":2,"production":0},"2016-Q2":{"hours":968,"employees":2,"production":0},"2016-Q1":{"hours":912,"employees":2,"production":0},"2015-Q4":{"hours":912,"employees":2,"production":0},"2015-Q2":{"hours":992,"employees":2,"production":0},"2015-Q1":{"hours":992,"employees":2,"production":0},"2014-Q4":{"hours":1616,"employees":3,"production":0},"2014-Q3":{"hours":1320,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":38,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003":{"hours":394017,"employees":187,"production":1368273},"2004":{"hours":426972,"employees":197,"production":1369460},"2005":{"hours":509014,"employees":223,"production":1565265},"2006":{"hours":455952,"employees":201,"production":1325500},"2007":{"hours":319887,"employees":146,"production":843499},"2008":{"hours":2494,"employees":2,"production":0},"2014":{"hours":7443,"employees":3,"production":0},"2015":{"hours":2896,"employees":2,"production":0},"2016":{"hours":3728,"employees":4,"production":0},"2017":{"hours":1984,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":58,"firstDate":"2000-05-31","lastDate":"2017-03-07","metrics":{"recentRows":0,"doseOver100":15,"actDoseTotal":4053,"pelDoseTotal":3224},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"18729","EVENT_NO":"6455788","SURVEY_DATE":"03/07/2017","OCCUPATION_CD_DESC":"OUTSIDE FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2017-03-07"},{"SOURCE_ROW_NUMBER":"18728","EVENT_NO":"6455788","SURVEY_DATE":"03/07/2017","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"14","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2017-03-07"},{"SOURCE_ROW_NUMBER":"18682","EVENT_NO":"4257707","SURVEY_DATE":"08/24/2015","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","ACT_DOSE_85":"65","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2015-08-24"},{"SOURCE_ROW_NUMBER":"18681","EVENT_NO":"4256881","SURVEY_DATE":"06/11/2014","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"17","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2014-06-11"},{"SOURCE_ROW_NUMBER":"18680","EVENT_NO":"4256874","SURVEY_DATE":"12/23/2013","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"26","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2013-12-23"},{"SOURCE_ROW_NUMBER":"18679","EVENT_NO":"4256874","SURVEY_DATE":"12/23/2013","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"24","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2013-12-23"},{"SOURCE_ROW_NUMBER":"18678","EVENT_NO":"4256874","SURVEY_DATE":"12/23/2013","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"063","ACT_DOSE_85":"29","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2013-12-23"},{"SOURCE_ROW_NUMBER":"18674","EVENT_NO":"4256343","SURVEY_DATE":"12/12/2012","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2012-12-12"},{"SOURCE_ROW_NUMBER":"18673","EVENT_NO":"4256343","SURVEY_DATE":"12/12/2012","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2012-12-12"},{"SOURCE_ROW_NUMBER":"18672","EVENT_NO":"4256343","SURVEY_DATE":"12/12/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"03","MANUFACTURER_CD":"063","ACT_DOSE_85":"42","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2012-12-12"},{"SOURCE_ROW_NUMBER":"18677","EVENT_NO":"4256850","SURVEY_DATE":"06/13/2012","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"063","ACT_DOSE_85":"24","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2012-06-13"},{"SOURCE_ROW_NUMBER":"18676","EVENT_NO":"4256850","SURVEY_DATE":"06/13/2012","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"20","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2012-06-13"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":144,"firstDate":"2000-02-23","lastDate":"2007-08-09","metrics":{"recentRows":0,"voidSamples":4,"maxQuartzPct":15,"validSamples":140,"quartzPctTotal":509.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"70928","CASSETTE_NO":"57664623","SAMPLE_DT":"08/09/2007","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-08-09"},{"SOURCE_ROW_NUMBER":"158140","CASSETTE_NO":"50920626","SAMPLE_DT":"07/30/2007","QUARTZ_PCT":"04.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-07-30"},{"SOURCE_ROW_NUMBER":"133141","CASSETTE_NO":"57655386","SAMPLE_DT":"07/10/2007","QUARTZ_PCT":"06.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-07-10"},{"SOURCE_ROW_NUMBER":"84426","CASSETTE_NO":"57655373","SAMPLE_DT":"07/10/2007","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-07-10"},{"SOURCE_ROW_NUMBER":"1776","CASSETTE_NO":"57655567","SAMPLE_DT":"06/19/2007","QUARTZ_PCT":"02.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-19"},{"SOURCE_ROW_NUMBER":"89049","CASSETTE_NO":"57655392","SAMPLE_DT":"06/18/2007","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-18"},{"SOURCE_ROW_NUMBER":"141824","CASSETTE_NO":"57655593","SAMPLE_DT":"05/07/2007","QUARTZ_PCT":"03.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-05-07"},{"SOURCE_ROW_NUMBER":"120665","CASSETTE_NO":"57655482","SAMPLE_DT":"03/07/2007","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-03-07"},{"SOURCE_ROW_NUMBER":"81066","CASSETTE_NO":"57640763","SAMPLE_DT":"02/20/2007","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-02-20"},{"SOURCE_ROW_NUMBER":"132915","CASSETTE_NO":"57655494","SAMPLE_DT":"02/14/2007","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-02-14"},{"SOURCE_ROW_NUMBER":"24248","CASSETTE_NO":"57640420","SAMPLE_DT":"02/07/2007","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-02-07"},{"SOURCE_ROW_NUMBER":"52902","CASSETTE_NO":"50868727","SAMPLE_DT":"01/19/2007","QUARTZ_PCT":"04.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-01-19"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1639,"firstDate":"2000-01-04","lastDate":"2013-06-18","metrics":{"ss":636,"amountDue":354851,"contested":0,"amountPaid":354851,"recentRows":0,"section104d":3,"unterminated":4,"proposedPenalty":354851},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"477194","VIOLATION_NO":"8443768","VIOLATION_ISSUE_DT":"06/18/2013","SIG_SUB":"N","PART_SECTION":"77.106","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/11/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-06-18"},{"SOURCE_ROW_NUMBER":"477193","VIOLATION_NO":"8443766","VIOLATION_ISSUE_DT":"06/18/2013","SIG_SUB":"N","PART_SECTION":"40.4","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/11/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-06-18"},{"SOURCE_ROW_NUMBER":"477192","VIOLATION_NO":"8443765","VIOLATION_ISSUE_DT":"06/11/2013","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/11/2013","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"477191","VIOLATION_NO":"8443764","VIOLATION_ISSUE_DT":"06/11/2013","SIG_SUB":"N","PART_SECTION":"77.1103(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/11/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"477938","VIOLATION_NO":"8443263","VIOLATION_ISSUE_DT":"12/12/2012","SIG_SUB":"N","PART_SECTION":"77.1109(e)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/12/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-12-12"},{"SOURCE_ROW_NUMBER":"477187","VIOLATION_NO":"6676709","VIOLATION_ISSUE_DT":"06/01/2010","SIG_SUB":"N","PART_SECTION":"77.900-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/02/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-06-01"},{"SOURCE_ROW_NUMBER":"477186","VIOLATION_NO":"6676708","VIOLATION_ISSUE_DT":"06/01/2010","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/02/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-06-01"},{"SOURCE_ROW_NUMBER":"477185","VIOLATION_NO":"6676707","VIOLATION_ISSUE_DT":"06/01/2010","SIG_SUB":"N","PART_SECTION":"77.800-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/02/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-06-01"},{"SOURCE_ROW_NUMBER":"477893","VIOLATION_NO":"6676300","VIOLATION_ISSUE_DT":"11/04/2009","SIG_SUB":"Y","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"11/09/2009","PROPOSED_PENALTY":"2000","AMOUNT_DUE":"2000","AMOUNT_PAID":"2000","CONTESTED_IND":"N","sourceDate":"2009-11-04"},{"SOURCE_ROW_NUMBER":"477892","VIOLATION_NO":"6676299","VIOLATION_ISSUE_DT":"11/04/2009","SIG_SUB":"Y","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"11/09/2009","PROPOSED_PENALTY":"2000","AMOUNT_DUE":"2000","AMOUNT_PAID":"2000","CONTESTED_IND":"N","sourceDate":"2009-11-04"},{"SOURCE_ROW_NUMBER":"477198","VIOLATION_NO":"6675350","VIOLATION_ISSUE_DT":"06/17/2009","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"12/01/2011","CONTESTED_IND":"N","sourceDate":"2009-06-17"},{"SOURCE_ROW_NUMBER":"477197","VIOLATION_NO":"6675349","VIOLATION_ISSUE_DT":"06/17/2009","SIG_SUB":"Y","PART_SECTION":"77.200","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"12/01/2011","PROPOSED_PENALTY":"2341","AMOUNT_DUE":"2341","AMOUNT_PAID":"2341","CONTESTED_IND":"N","sourceDate":"2009-06-17"}]}],"safety":{"href":"/api/v1/mines/1102236/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1102236/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Records of certified and qualified persons.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-B/section-77.106","part":"77","subchapter":"O","subpart":"B","id":"77.106","citation":"30 CFR 77.106","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Posting at mine.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-G/part-40/section-40.4","part":"40","subchapter":"G","subpart":"","id":"40.4","citation":"30 CFR 40.4","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER G—FILING AND OTHER ADMINISTRATIVE REQUIREMENTS","partHeading":"PART 40—REPRESENTATIVE OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; procedures.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.900-1","part":"77","subchapter":"O","subpart":"J","id":"77.900-1","citation":"30 CFR 77.900-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; procedures.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-I/section-77.800-1","part":"77","subchapter":"O","subpart":"I","id":"77.800-1","citation":"30 CFR 77.800-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","heading":"Surface installations; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.200","part":"77","subchapter":"O","subpart":"C","id":"77.200","citation":"30 CFR 77.200","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1102236","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}