{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1100601","name":"Franklin County Mine","status":"Abandoned and Sealed","status_date":"2026-08-19","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"IL","county":"Jefferson","nearest_town":"Sesser","operator_id":"0173513","operator_name":"Franklin County Land Resources, Inc.","controller_id":"0157801","controller_name":"ACNR Holdings, Inc","district":"C08","office":"Marion IL Field Office","employees":0,"latitude":38.142778,"longitude":-89.033889},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":5946},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"operator":{"type":"operator","id":"0173513","name":"Franklin County Land Resources, Inc."},"controller":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"validFrom":"1950-01-01","validTo":"2013-12-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|C00692|1950-01-01|2013-12-04"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P02833","name":"Inland Steel Coal Company"},"object":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"validFrom":"1950-01-01","validTo":"1986-11-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|P02833|1950-01-01|1986-11-13"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02429","name":"Inland Steel Company"},"object":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"validFrom":"1950-01-01","validTo":"1986-11-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|C02429|1950-01-01|1986-11-14"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02429","name":"Inland Steel Company"},"object":{"type":"operator","id":"P02833","name":"Inland Steel Coal Company"},"validFrom":"1950-01-01","validTo":"1986-11-13","current":false,"derived":true,"evidenceMineId":"1100601","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|P02833|1950-01-01|C02429|1950-01-01|58431"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"object":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"validFrom":"1986-11-14","validTo":"2017-02-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|P00812|1986-11-14|2017-02-26"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"validFrom":"1986-11-14","validTo":"2013-12-04","current":false,"derived":true,"evidenceMineId":"1100601","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|P00812|1986-11-14|C00692|1950-01-01|49050"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"validFrom":"2013-12-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|C13408|2013-12-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"validFrom":"2013-12-05","validTo":"2017-02-26","current":false,"derived":true,"evidenceMineId":"1100601","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|P00812|1986-11-14|C13408|2013-12-05|89619"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0149973","name":"The Franklin County Coal Company"},"object":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"validFrom":"2017-02-27","validTo":"2020-09-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|0149973|2017-02-27|2020-09-16"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"validFrom":"2017-02-27","validTo":"2020-09-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|C13408|2017-02-27|2020-09-16"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"operator","id":"0149973","name":"The Franklin County Coal Company"},"validFrom":"2017-02-27","validTo":"2020-09-16","current":false,"derived":true,"evidenceMineId":"1100601","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|0149973|2017-02-27|C13408|2017-02-27|89808"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"object":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"validFrom":"2020-09-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|0157801|2020-09-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"object":{"type":"operator","id":"0149973","name":"The Franklin County Coal Company"},"validFrom":"2020-09-17","validTo":"2020-09-16","current":false,"derived":true,"evidenceMineId":"1100601","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|0149973|2017-02-27|0157801|2020-09-17|32622"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0173513","name":"Franklin County Land Resources, Inc."},"object":{"type":"mine","id":"1100601","name":"Franklin County Mine"},"validFrom":"2020-09-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|0173513|2020-09-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"object":{"type":"operator","id":"0173513","name":"Franklin County Land Resources, Inc."},"validFrom":"2020-09-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"1100601","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1100601|0173513|2020-09-17|0157801|2020-09-17|32623"}}],"coverage":{"historyRecords":6,"edgeCount":15,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":131,"firstDate":"2000-01-25","lastDate":"2018-02-20","metrics":{"daysLost":2043,"injuries":59,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"181432","DOCUMENT_NO":"220180580028","ACCIDENT_DT":"02/20/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"80","NARRATIVE":"Employee parked D10 dozer & was dismounting when a gust of wind pushed the door & employee onto the track crawler & down to tilt jack. Cause of injury no 3 point contact while climbing down. Incident didn't involve any aspect of compliance with rules/regulations/PPE. Miner proficiency may have been a factor. Started missing work 2/27/18. Work was idle from 2/21/18 till 2/27/18.","sourceDate":"2018-02-20"},{"SOURCE_ROW_NUMBER":"95228","DOCUMENT_NO":"220030870014","ACCIDENT_DT":"03/17/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"HOISTING","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"EMERGENCY ESCAPE HOIST SHAFT ICED UP DUE TO COLD WEATHER DONDITIONS WEATHER CONDITIONS STARTED CHANGING AND ILE FELL DOWN SHAFT STRUCK GUIDE ROPE JUST RIGHT CAUSING GUIDE ROPE TO BREAK. CONDIT ON NOTED ON DATE ABOVE.","sourceDate":"2003-03-17"},{"SOURCE_ROW_NUMBER":"189986","DOCUMENT_NO":"220030660050","ACCIDENT_DT":"02/28/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"86","NARRATIVE":"EMPLOYEE WAS OPERATING A GETMAN TRACTOR, HELPED LOAD MATERIAL ON MAN CAGE, WHEN CAGE RETURNED TO BOTTOM HE WALKED TOWARDS HIS TRACTOR AND TRIPPED ON A WIRE ROPE SLING AND FELL ON HIS HANDS A ND KNEES. ACCIDENT OCCURRED 1-24-03 BUT WAS NOT DIAGNOSED UNTIL 2-20-03 WITH A TORN MENISCUS RIGHT KNEE.","sourceDate":"2003-02-28"},{"SOURCE_ROW_NUMBER":"233051","DOCUMENT_NO":"220030410126","ACCIDENT_DT":"02/04/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A FALL OF ROOF WAS FOUND AT 12:45PM 87XC MAIN EASTWAY. FALL FELL ON TOP OF ARCH & SOME ROCK CAMEOUT ONTO THE TWAY. FALL GUESSED TO BE 6' HIGH, 20'LONG, & 10' WIDE. ROOF OVER ARCHES SUPPORTED WITH 6' CONVENTIONAL","sourceDate":"2003-02-04"},{"SOURCE_ROW_NUMBER":"164256","DOCUMENT_NO":"220030410127","ACCIDENT_DT":"02/04/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A FALL OF ROOF WAS FOUND DURING AN INSPECTION DURING AN INSPECTION OF THE MAIN EAST LEFT RETURN AT XC34. THE FALL WAS 16'WIDE, 6' HIGH, & 5O' LONG DID NOT INVOLVE THE INTERSECTION FELL IN XC BETWEEN ENTERIES 3 & 4 AC. 6 FT CONVENTIONAL BOLTS USED.","sourceDate":"2003-02-04"},{"SOURCE_ROW_NUMBER":"228815","DOCUMENT_NO":"220030360006","ACCIDENT_DT":"01/31/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"HOISTING","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AT 10:00 A HOIST TEST WAS PREFORMED AND WHEN THE LILLY OVER SPEED CHECK WAS MADE THE NUT CAME OFF THE SHAFT THAT HOLDS THE OVER SPEED IN PLACE. REPAIRED @ 10 45 AM FULL SERVICE.","sourceDate":"2003-01-31"},{"SOURCE_ROW_NUMBER":"26676","DOCUMENT_NO":"220030230019","ACCIDENT_DT":"01/20/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A FALL OF ROOF WAS FOUND BY AN EXAMINER JUST OUT BY #8 SEAL OF THE MAIN EAST 2 LEFT SEALS. THE FALL WAS 50' W 30' L AND 7' H AND SUPPORTED BY 6'CONVENTIONAL BOLTS.","sourceDate":"2003-01-20"},{"SOURCE_ROW_NUMBER":"224435","DOCUMENT_NO":"220030230018","ACCIDENT_DT":"01/19/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A FALL OF ROOF WAS FOUND IN 4J 3AC 47 AND 40 FOOT MARKER. 6 FOOT DOUBLE LOCK BOLTS WERE USED. THE FALL WAS 70 FT LONG 16-18 FT WIDE AND 10 FT HIGH.","sourceDate":"2003-01-19"},{"SOURCE_ROW_NUMBER":"13716","DOCUMENT_NO":"220030030007","ACCIDENT_DT":"12/28/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A FALL OF ROOF OCCURRED ON THE 4J SETUP CUTBACKS 2AC FROM 2+24 TO 2+54 AT THREE-WAY INTERSECTION 30' LONG, 30' WIDE, 8' HIGH. SUPPORTED BY 6' D0UBLE LOCK BOLTS.","sourceDate":"2002-12-28"},{"SOURCE_ROW_NUMBER":"13715","DOCUMENT_NO":"220023080126","ACCIDENT_DT":"10/28/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"25","NARRATIVE":"THE INJURED EE WAS INSTALLING A ROOF BOLT ON THE MAIN EAST BELT ENTRY WHEN HE WAS STRUCK BY A PIECE OF FALLING ROCK.","sourceDate":"2002-10-28"},{"SOURCE_ROW_NUMBER":"26675","DOCUMENT_NO":"220023010077","ACCIDENT_DT":"10/21/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A FALL OF ROOF WAS FOUND WHILE ON INSPECTION WITH MSHA. THE LOCATION IS BETWEEN THE MAIN EAST TRAVELWAY AND MAIN EAST #2 BELT AT 66XCUT ON THE BELTLINE SIDE OF THE STOPPING. H 6 1/2' X 18' W X 15' L. SUPPORTED BY 6' CONVENTIONAL BOLTS.","sourceDate":"2002-10-21"},{"SOURCE_ROW_NUMBER":"194236","DOCUMENT_NO":"220022900051","ACCIDENT_DT":"10/14/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"HOISTING","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"MANCAGE/HOIST WOULD NOT OPERATE DUE TO THE FAILURE OF A MOTOR AUXILARY RELAY. NO PEOPLE ON CAGE. HOIST WAS REPAIRED & RETURNED TO SERVICE @ 5:45 A.M.","sourceDate":"2002-10-14"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-08-19","lastDate":"2026-08-19","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1456,"firstDate":"2000-01-04","lastDate":"2013-10-11","metrics":{"ss":447,"delinquent":1451,"recentRows":0,"paidPenalty":449478,"proposedPenalty":468829,"currentAssessment":449478},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1199618","VIOLATION_NO":"8451406","ISSUE_DT":"10/11/2013","CFR_STANDARD_CD":"77.1900(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-11"},{"SOURCE_ROW_NUMBER":"1188946","VIOLATION_NO":"8424038","ISSUE_DT":"08/26/2010","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-08-26"},{"SOURCE_ROW_NUMBER":"1624025","VIOLATION_NO":"8417089","ISSUE_DT":"06/29/2009","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-06-29"},{"SOURCE_ROW_NUMBER":"1624024","VIOLATION_NO":"8417064","ISSUE_DT":"05/21/2009","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-05-21"},{"SOURCE_ROW_NUMBER":"1624023","VIOLATION_NO":"8417063","ISSUE_DT":"05/21/2009","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-05-21"},{"SOURCE_ROW_NUMBER":"1624022","VIOLATION_NO":"8417062","ISSUE_DT":"05/21/2009","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"127.00","CURRENT_ASSESSMENT_AMT":"127.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-05-21"},{"SOURCE_ROW_NUMBER":"1624021","VIOLATION_NO":"8417061","ISSUE_DT":"05/20/2009","CFR_STANDARD_CD":"77.1605(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-05-20"},{"SOURCE_ROW_NUMBER":"1624020","VIOLATION_NO":"8417060","ISSUE_DT":"05/20/2009","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"174.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-05-20"},{"SOURCE_ROW_NUMBER":"1624019","VIOLATION_NO":"8417059","ISSUE_DT":"05/20/2009","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-05-20"},{"SOURCE_ROW_NUMBER":"1624018","VIOLATION_NO":"8417058","ISSUE_DT":"05/20/2009","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-05-20"},{"SOURCE_ROW_NUMBER":"1605430","VIOLATION_NO":"4872436","ISSUE_DT":"04/10/2003","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-10"},{"SOURCE_ROW_NUMBER":"1630879","VIOLATION_NO":"7577176","ISSUE_DT":"03/27/2003","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"993.00","CURRENT_ASSESSMENT_AMT":"993.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-03-27"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":17,"firstDate":"2001-05-16","lastDate":"2010-11-10","metrics":{"appeals":0,"decisions":17,"recentRows":0,"decisionPenalty":64329,"originalPenalty":85300},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"43092","VIOLATION_NO":"8417060","DOCKET_NO":"LAKE 2009-574","DECISION_DT":"11/10/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"174.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2010-11-10"},{"SOURCE_ROW_NUMBER":"469978","VIOLATION_NO":"7575643","DOCKET_NO":"LAKE20020159","DECISION_DT":"07/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2500.00","DECISION_PENALTY_AMT":"1000.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"469135","VIOLATION_NO":"7575641","DOCKET_NO":"LAKE20020159","DECISION_DT":"07/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5500.00","DECISION_PENALTY_AMT":"5500.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"469134","VIOLATION_NO":"7565040","DOCKET_NO":"LAKE20020159","DECISION_DT":"07/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"9000.00","DECISION_PENALTY_AMT":"6000.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"468794","VIOLATION_NO":"7571780","DOCKET_NO":"LAKE20020159","DECISION_DT":"07/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8000.00","DECISION_PENALTY_AMT":"8000.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"172676","VIOLATION_NO":"7575660","DOCKET_NO":"LAKE20020159","DECISION_DT":"07/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4500.00","DECISION_PENALTY_AMT":"4500.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"469304","VIOLATION_NO":"7590906","DOCKET_NO":"LAKE20020076","DECISION_DT":"11/15/2002","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8000.00","DECISION_PENALTY_AMT":"5000.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2002-11-15"},{"SOURCE_ROW_NUMBER":"172786","VIOLATION_NO":"7570363","DOCKET_NO":"LAKE20020043","DECISION_DT":"04/10/2002","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1595.00","DECISION_PENALTY_AMT":"655.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2002-04-10"},{"SOURCE_ROW_NUMBER":"469133","VIOLATION_NO":"7574269","DOCKET_NO":"LAKE20020010","DECISION_DT":"02/05/2002","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4000.00","DECISION_PENALTY_AMT":"4000.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2002-02-05"},{"SOURCE_ROW_NUMBER":"172785","VIOLATION_NO":"7572169","DOCKET_NO":"LAKE20020010","DECISION_DT":"02/05/2002","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5500.00","DECISION_PENALTY_AMT":"5500.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2002-02-05"},{"SOURCE_ROW_NUMBER":"469303","VIOLATION_NO":"9942214","DOCKET_NO":"LAKE20010209","DECISION_DT":"01/04/2002","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4620.00","DECISION_PENALTY_AMT":"3000.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2002-01-04"},{"SOURCE_ROW_NUMBER":"469132","VIOLATION_NO":"7573429","DOCKET_NO":"LAKE20010150","DECISION_DT":"09/26/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4500.00","DECISION_PENALTY_AMT":"3000.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2001-09-26"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1015,"firstDate":"2000-01-10","lastDate":"2024-05-31","metrics":{"recentRows":44,"cpdmSamples":0,"voidSamples":97,"validSamples":918,"maxConcentration":18.514,"concentrationTotal":1199.333},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"945575","CASS_NUM":"51518400","SMP_TAKEN_DT":"5/31/2024","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2024-05-31"},{"SOURCE_ROW_NUMBER":"242186","CASS_NUM":"51518330","SMP_TAKEN_DT":"3/21/2024","CONC":".031","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2024-03-21"},{"SOURCE_ROW_NUMBER":"618249","CASS_NUM":"51518314","SMP_TAKEN_DT":"12/7/2023","CONC":".012","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-12-07"},{"SOURCE_ROW_NUMBER":"78445","CASS_NUM":"51525353","SMP_TAKEN_DT":"11/7/2023","CONC":".041","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DWP NOT IN PRODUCING STATUS","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-11-07"},{"SOURCE_ROW_NUMBER":"958888","CASS_NUM":"58451395","SMP_TAKEN_DT":"10/11/2023","CONC":".043","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-10-11"},{"SOURCE_ROW_NUMBER":"860441","CASS_NUM":"58451262","SMP_TAKEN_DT":"10/11/2023","CONC":".062","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-10-11"},{"SOURCE_ROW_NUMBER":"237241","CASS_NUM":"58451407","SMP_TAKEN_DT":"10/11/2023","CONC":".045","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-10-11"},{"SOURCE_ROW_NUMBER":"73880","CASS_NUM":"58451047","SMP_TAKEN_DT":"10/11/2023","CONC":".067","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-10-11"},{"SOURCE_ROW_NUMBER":"1046395","CASS_NUM":"51525466","SMP_TAKEN_DT":"9/8/2023","CONC":".031","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"774721","CASS_NUM":"51525482","SMP_TAKEN_DT":"6/23/2023","CONC":".034","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-06-23"},{"SOURCE_ROW_NUMBER":"1412115","CASS_NUM":"58470751","SMP_TAKEN_DT":"5/31/2023","CONC":".038","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-05-31"},{"SOURCE_ROW_NUMBER":"1358486","CASS_NUM":"58470974","SMP_TAKEN_DT":"5/31/2023","CONC":".032","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-05-31"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":35,"firstDate":"2000-02-16","lastDate":"2002-11-06","metrics":{"linkedIssuances":35},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1,"firstDate":"2009-05-20","lastDate":"2009-05-20","metrics":{"decisions":1,"ssChanged":0,"recentRows":0,"decisionPenalty":174,"proposedPenalty":585},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"297679","CITATION_NO":"8417060","CITATION_ISSUE_DT":"05/20/2009","DOCKET_NO":"LAKE 2009-574","DECISION_DT":"11/10/2010","CFR_STANDARD_CODE":"77.1104","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"174.00","sourceDate":"2009-05-20"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":749,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":150,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"1950-01-01","lastDate":"2020-09-17","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":5},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":411,"firstDate":"2000-01-03","lastDate":"2026-03-16","metrics":{"inspectors":515,"recentRows":14,"onSiteHours":7927.75,"inspectionHours":12412.5,"inspectionSamples":48},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"947655","EVENT_NO":"F009CF9","INSPECTION_BEGIN_DT":"03/16/2026","INSPECTION_END_DT":"03/16/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"1070406","EVENT_NO":"F00223E","INSPECTION_BEGIN_DT":"09/10/2025","INSPECTION_END_DT":"09/10/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2025-09-10"},{"SOURCE_ROW_NUMBER":"308743","EVENT_NO":"7031492","INSPECTION_BEGIN_DT":"03/04/2025","INSPECTION_END_DT":"03/04/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2025-03-04"},{"SOURCE_ROW_NUMBER":"45878","EVENT_NO":"7031472","INSPECTION_BEGIN_DT":"08/22/2024","INSPECTION_END_DT":"08/23/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2024-08-22"},{"SOURCE_ROW_NUMBER":"54454","EVENT_NO":"7023045","INSPECTION_BEGIN_DT":"10/10/2023","INSPECTION_END_DT":"11/27/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"26.5","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2023-10-10"},{"SOURCE_ROW_NUMBER":"80845","EVENT_NO":"7018629","INSPECTION_BEGIN_DT":"06/12/2023","INSPECTION_END_DT":"06/12/2023","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2023-06-12"},{"SOURCE_ROW_NUMBER":"523391","EVENT_NO":"7023038","INSPECTION_BEGIN_DT":"05/30/2023","INSPECTION_END_DT":"06/27/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"9.25","sourceDate":"2023-05-30"},{"SOURCE_ROW_NUMBER":"424510","EVENT_NO":"7018611","INSPECTION_BEGIN_DT":"10/17/2022","INSPECTION_END_DT":"10/17/2022","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2022-10-17"},{"SOURCE_ROW_NUMBER":"691327","EVENT_NO":"7023150","INSPECTION_BEGIN_DT":"10/05/2022","INSPECTION_END_DT":"11/29/2022","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"31.5","SUM_TOTAL_ON_SITE_HOURS":"18","sourceDate":"2022-10-05"},{"SOURCE_ROW_NUMBER":"445693","EVENT_NO":"7022740","INSPECTION_BEGIN_DT":"06/01/2022","INSPECTION_END_DT":"07/28/2022","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"34.5","SUM_TOTAL_ON_SITE_HOURS":"18.5","sourceDate":"2022-06-01"},{"SOURCE_ROW_NUMBER":"606163","EVENT_NO":"7022706","INSPECTION_BEGIN_DT":"10/04/2021","INSPECTION_END_DT":"02/24/2022","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"44.75","SUM_TOTAL_ON_SITE_HOURS":"18.5","sourceDate":"2021-10-04"},{"SOURCE_ROW_NUMBER":"997171","EVENT_NO":"7006895","INSPECTION_BEGIN_DT":"07/19/2021","INSPECTION_END_DT":"07/28/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.5","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2021-07-19"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":291,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":117,"employees":2,"production":0},"2026-Q1":{"hours":117,"employees":2,"production":0},"2025-Q4":{"hours":117,"employees":2,"production":0},"2025-Q3":{"hours":126,"employees":2,"production":0},"2025-Q2":{"hours":117,"employees":2,"production":0},"2025-Q1":{"hours":108,"employees":2,"production":0},"2024-Q4":{"hours":117,"employees":2,"production":0},"2024-Q3":{"hours":117,"employees":2,"production":0},"2024-Q2":{"hours":533,"employees":2,"production":0},"2024-Q1":{"hours":264,"employees":4,"production":0},"2023-Q4":{"hours":2326,"employees":6,"production":0},"2023-Q3":{"hours":2578,"employees":6,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":44,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":8430,"employees":5,"production":0},"2018":{"hours":10006,"employees":7,"production":0},"2019":{"hours":13376,"employees":7,"production":0},"2020":{"hours":6800,"employees":5,"production":0},"2021":{"hours":8162,"employees":5,"production":0},"2022":{"hours":12434,"employees":6,"production":0},"2023":{"hours":9220,"employees":6,"production":0},"2024":{"hours":1031,"employees":3,"production":0},"2025":{"hours":468,"employees":2,"production":0},"2026":{"hours":234,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":69,"firstDate":"2000-03-08","lastDate":"2023-10-11","metrics":{"recentRows":13,"doseOver100":12,"actDoseTotal":4789,"pelDoseTotal":3249},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"18226","EVENT_NO":"7023045","SURVEY_DATE":"10/11/2023","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"60","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2023-10-11"},{"SOURCE_ROW_NUMBER":"18225","EVENT_NO":"7023045","SURVEY_DATE":"10/11/2023","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"29","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2023-10-11"},{"SOURCE_ROW_NUMBER":"18224","EVENT_NO":"7023045","SURVEY_DATE":"10/11/2023","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2023-10-11"},{"SOURCE_ROW_NUMBER":"18223","EVENT_NO":"7023045","SURVEY_DATE":"10/11/2023","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2023-10-11"},{"SOURCE_ROW_NUMBER":"18231","EVENT_NO":"7023150","SURVEY_DATE":"10/11/2022","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"24","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2022-10-11"},{"SOURCE_ROW_NUMBER":"18230","EVENT_NO":"7023150","SURVEY_DATE":"10/11/2022","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"11","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2022-10-11"},{"SOURCE_ROW_NUMBER":"18229","EVENT_NO":"7023150","SURVEY_DATE":"10/11/2022","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"23","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2022-10-11"},{"SOURCE_ROW_NUMBER":"18228","EVENT_NO":"7023150","SURVEY_DATE":"10/11/2022","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"76","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2022-10-11"},{"SOURCE_ROW_NUMBER":"18227","EVENT_NO":"7023150","SURVEY_DATE":"10/11/2022","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"22","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2022-10-11"},{"SOURCE_ROW_NUMBER":"18222","EVENT_NO":"7022706","SURVEY_DATE":"10/05/2021","OCCUPATION_CD_DESC":"OUTSIDE FOREMAN","MACHINE_CD":"40","ACT_DOSE_85":"21","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2021-10-05"},{"SOURCE_ROW_NUMBER":"18221","EVENT_NO":"7022706","SURVEY_DATE":"10/05/2021","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"49","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2021-10-05"},{"SOURCE_ROW_NUMBER":"18220","EVENT_NO":"7022706","SURVEY_DATE":"10/05/2021","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2021-10-05"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":97,"firstDate":"2000-01-13","lastDate":"2009-06-29","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":12.5,"validSamples":94,"quartzPctTotal":295.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"134174","CASSETTE_NO":"57804945","SAMPLE_DT":"06/29/2009","QUARTZ_PCT":"09.3","OCC_CODE_DESC":"ROAD GRADER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-06-29"},{"SOURCE_ROW_NUMBER":"89631","CASSETTE_NO":"57435486","SAMPLE_DT":"05/02/2002","QUARTZ_PCT":"05.6","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-02"},{"SOURCE_ROW_NUMBER":"106182","CASSETTE_NO":"57401380","SAMPLE_DT":"04/23/2002","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-04-23"},{"SOURCE_ROW_NUMBER":"139727","CASSETTE_NO":"57383948","SAMPLE_DT":"02/13/2002","QUARTZ_PCT":"02.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-13"},{"SOURCE_ROW_NUMBER":"137094","CASSETTE_NO":"57383879","SAMPLE_DT":"02/13/2002","QUARTZ_PCT":"02.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-13"},{"SOURCE_ROW_NUMBER":"154625","CASSETTE_NO":"57383864","SAMPLE_DT":"02/11/2002","QUARTZ_PCT":"03.4","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-11"},{"SOURCE_ROW_NUMBER":"33204","CASSETTE_NO":"57383936","SAMPLE_DT":"02/06/2002","QUARTZ_PCT":"04.0","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-06"},{"SOURCE_ROW_NUMBER":"48485","CASSETTE_NO":"57383894","SAMPLE_DT":"01/30/2002","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-30"},{"SOURCE_ROW_NUMBER":"24641","CASSETTE_NO":"57383706","SAMPLE_DT":"01/29/2002","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-29"},{"SOURCE_ROW_NUMBER":"148450","CASSETTE_NO":"57383611","SAMPLE_DT":"01/24/2002","QUARTZ_PCT":"01.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-24"},{"SOURCE_ROW_NUMBER":"76325","CASSETTE_NO":"57383597","SAMPLE_DT":"01/14/2002","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-14"},{"SOURCE_ROW_NUMBER":"51104","CASSETTE_NO":"57383604","SAMPLE_DT":"01/14/2002","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-14"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1472,"firstDate":"2000-01-04","lastDate":"2013-10-11","metrics":{"ss":448,"amountDue":449478,"contested":16,"amountPaid":449478,"recentRows":0,"section104d":16,"unterminated":6,"proposedPenalty":468829},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"459024","VIOLATION_NO":"8451407","VIOLATION_ISSUE_DT":"10/11/2013","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"10/30/2013","CONTESTED_IND":"N","sourceDate":"2013-10-11"},{"SOURCE_ROW_NUMBER":"459023","VIOLATION_NO":"8451406","VIOLATION_ISSUE_DT":"10/11/2013","SIG_SUB":"N","PART_SECTION":"77.1900(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/11/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-10-11"},{"SOURCE_ROW_NUMBER":"458309","VIOLATION_NO":"8424038","VIOLATION_ISSUE_DT":"08/26/2010","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/02/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-08-26"},{"SOURCE_ROW_NUMBER":"458323","VIOLATION_NO":"8417089","VIOLATION_ISSUE_DT":"06/29/2009","SIG_SUB":"Y","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/29/2009","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2009-06-29"},{"SOURCE_ROW_NUMBER":"458322","VIOLATION_NO":"8417064","VIOLATION_ISSUE_DT":"05/21/2009","SIG_SUB":"N","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-05-21"},{"SOURCE_ROW_NUMBER":"458321","VIOLATION_NO":"8417063","VIOLATION_ISSUE_DT":"05/21/2009","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-05-21"},{"SOURCE_ROW_NUMBER":"458320","VIOLATION_NO":"8417062","VIOLATION_ISSUE_DT":"05/21/2009","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2009","PROPOSED_PENALTY":"127","AMOUNT_DUE":"127","AMOUNT_PAID":"127","CONTESTED_IND":"N","sourceDate":"2009-05-21"},{"SOURCE_ROW_NUMBER":"458319","VIOLATION_NO":"8417061","VIOLATION_ISSUE_DT":"05/20/2009","SIG_SUB":"N","PART_SECTION":"77.1605(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-05-20"},{"SOURCE_ROW_NUMBER":"458318","VIOLATION_NO":"8417060","VIOLATION_ISSUE_DT":"05/20/2009","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"05/21/2009","PROPOSED_PENALTY":"585","AMOUNT_DUE":"174","AMOUNT_PAID":"174","CONTESTED_IND":"Y","DOCKET_NO":"LAKE 2009-574","sourceDate":"2009-05-20"},{"SOURCE_ROW_NUMBER":"458317","VIOLATION_NO":"8417059","VIOLATION_ISSUE_DT":"05/20/2009","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2009","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2009-05-20"},{"SOURCE_ROW_NUMBER":"458316","VIOLATION_NO":"8417058","VIOLATION_ISSUE_DT":"05/20/2009","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/20/2009","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2009-05-20"},{"SOURCE_ROW_NUMBER":"458324","VIOLATION_NO":"4872436","VIOLATION_ISSUE_DT":"04/10/2003","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/10/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-04-10"}]}],"safety":{"href":"/api/v1/mines/1100601/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1100601/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Slopes and shafts; approval of plans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-T/section-77.1900","part":"77","subchapter":"O","subpart":"T","id":"77.1900","citation":"30 CFR 77.1900","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1100601","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}