{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"0503455","name":"Southfield Mine","status":"Abandoned","status_date":"2001-05-10","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"CO","county":"Fremont","nearest_town":"Florence","operator_id":"P16558","operator_name":"Energy Fuels Coal Inc","controller_id":"C05318","controller_name":"Energy Fuels Coal Resources Ltd","district":"C09","office":"Farmington NM Field Office","employees":0,"latitude":38.283333,"longitude":-104.133333},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":350},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"0503455","name":"Southfield Mine"},"operator":{"type":"operator","id":"P16558","name":"Energy Fuels Coal Inc"},"controller":{"type":"controller","id":"C05318","name":"Energy Fuels Coal Resources Ltd"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C06785","name":"Damson Oil Corp"},"object":{"type":"mine","id":"0503455","name":"Southfield Mine"},"validFrom":"1978-07-01","validTo":"1987-02-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0503455|C06785|1978-07-01|1987-02-06"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P08516","name":"Dorchester Coal Company"},"object":{"type":"mine","id":"0503455","name":"Southfield Mine"},"validFrom":"1979-08-01","validTo":"1985-03-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0503455|P08516|1979-08-01|1985-03-21"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06785","name":"Damson Oil Corp"},"object":{"type":"operator","id":"P08516","name":"Dorchester Coal Company"},"validFrom":"1979-08-01","validTo":"1985-03-21","current":false,"derived":true,"evidenceMineId":"0503455","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0503455|P08516|1979-08-01|C06785|1978-07-01|72930"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P16558","name":"Energy Fuels Coal Inc"},"object":{"type":"mine","id":"0503455","name":"Southfield Mine"},"validFrom":"1985-03-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0503455|P16558|1985-03-22|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C05318","name":"Energy Fuels Coal Resources Ltd"},"object":{"type":"mine","id":"0503455","name":"Southfield Mine"},"validFrom":"1985-03-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0503455|C05318|1985-03-22|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C05318","name":"Energy Fuels Coal Resources Ltd"},"object":{"type":"operator","id":"P16558","name":"Energy Fuels Coal Inc"},"validFrom":"1985-03-22","validTo":null,"current":true,"derived":true,"evidenceMineId":"0503455","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0503455|P16558|1985-03-22|C05318|1985-03-22|68368"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":8,"firstDate":"2000-04-04","lastDate":"2001-08-21","metrics":{"daysLost":79,"injuries":4,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"245755","DOCUMENT_NO":"220012350011","ACCIDENT_DT":"08/21/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE WEEKLY EXAMINER FOUND A ROOF FALL IN THE 1STSOUTH MAINS RIGHT RETURN AT XC #9. FALL ~20'L X 20'W X 5'THICK. VENTILATION NOT AFFECTED.","sourceDate":"2001-08-21"},{"SOURCE_ROW_NUMBER":"64894","DOCUMENT_NO":"220003130006","ACCIDENT_DT":"09/29/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"19","NARRATIVE":"MINER WAS WALKING DOWN ENTRY WHEN HE SLIPPED ON UNEVEN FLOOR AND FELL DOWN. HURT HIS HIP. MINER DID NOT GO TO DR. UNTIL 4 WEEKS LATER.","sourceDate":"2000-09-29"},{"SOURCE_ROW_NUMBER":"13441","DOCUMENT_NO":"220002690175","ACCIDENT_DT":"09/18/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"CREW WAS MAKING A BELT MOVE IN 1 SOUTH PINE GULCH SECTION WHEN FOREMAN HEARD ROOF WORKING AT X CUT 8 & 40 IN THE MAIN ENTRY. ROOF FELL APPROX. 20' LONG 20' WIDE IN THE INTERSECTION. AREA HAD A DDITIONAL ROOF BOLTS AND ADDITIONAL TIMBER SET PRIOR TO ROOF FALL REPORTED TO TRINIDAD OFFICE 3:45 9-18-00. AREA WAS TIMBERED OFF.","sourceDate":"2000-09-18"},{"SOURCE_ROW_NUMBER":"86552","DOCUMENT_NO":"220002090051","ACCIDENT_DT":"07/26/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"WEEKLY EXAMINED FOUND ROOF FALL IN 2 SOUTH MAINS 2 RIGHT ENTRY APPROX. 50' OUTBY 2 SOUTH SEAL #5 FALL WAS 4 TO 5 FT HIGH APPROX. 30' LONG. TRINDAD FIELD OFFICE WAS NOTIFIED AT APPROX. 850 AM.","sourceDate":"2000-07-26"},{"SOURCE_ROW_NUMBER":"172564","DOCUMENT_NO":"220001810073","ACCIDENT_DT":"06/16/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL, XCUT 20+02, 1 LEFT PINE GULCH PANEL APPROX. 20' WIDE, 20' LONG, 5' HIGH. AREA WAS TIMBERED OFF. FALL DID NOT AFFECT VENTILATION. PULLED APPROX. 4 BOLTS.","sourceDate":"2000-06-16"},{"SOURCE_ROW_NUMBER":"241519","DOCUMENT_NO":"220001680039","ACCIDENT_DT":"06/12/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to lower level, NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"MINER GOT OUT OF HIS SHUTTLE CAR STEPPED IN A HOLE TWISTED ANKLE.","sourceDate":"2000-06-12"},{"SOURCE_ROW_NUMBER":"129312","DOCUMENT_NO":"220001680040","ACCIDENT_DT":"05/31/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"55","NARRATIVE":"EE SLIPPED AND HIT FACE ON TRUCK BED, CHIPPING TOOTH. WENT TO DENTIST. TOOTH GOT INFECT, MISSED WORK ON 6-13, 6-14, 6-15. MINER STILL OFF WORK AT TIME OF REPORT.","sourceDate":"2000-05-31"},{"SOURCE_ROW_NUMBER":"250028","DOCUMENT_NO":"220001030048","ACCIDENT_DT":"04/04/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"EMPLOYEE WAS OPERATING SC HIT BUMP SLAMMED BACK AND REAR ENDED DOWN ON SEAT.","sourceDate":"2000-04-04"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2001-05-10","lastDate":"2001-05-10","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":89,"firstDate":"2000-01-05","lastDate":"2000-12-13","metrics":{"ss":15,"delinquent":89,"recentRows":0,"paidPenalty":30829,"proposedPenalty":31266,"currentAssessment":30829},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1226623","VIOLATION_NO":"7626758","ISSUE_DT":"12/13/2000","CFR_STANDARD_CD":"75.333(c)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-12-13"},{"SOURCE_ROW_NUMBER":"1226622","VIOLATION_NO":"7603158","ISSUE_DT":"11/30/2000","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"1226621","VIOLATION_NO":"7603157","ISSUE_DT":"11/30/2000","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"92.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"1226620","VIOLATION_NO":"7603156","ISSUE_DT":"11/30/2000","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"66.00","CURRENT_ASSESSMENT_AMT":"66.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"1226619","VIOLATION_NO":"7603155","ISSUE_DT":"11/30/2000","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"1226618","VIOLATION_NO":"7603154","ISSUE_DT":"11/30/2000","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"92.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"1226617","VIOLATION_NO":"7603153","ISSUE_DT":"11/30/2000","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"1226616","VIOLATION_NO":"7603152","ISSUE_DT":"11/30/2000","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"242.00","CURRENT_ASSESSMENT_AMT":"242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"1226624","VIOLATION_NO":"7636293","ISSUE_DT":"10/26/2000","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"399.00","CURRENT_ASSESSMENT_AMT":"399.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-10-26"},{"SOURCE_ROW_NUMBER":"1221778","VIOLATION_NO":"7604031","ISSUE_DT":"07/20/2000","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-07-20"},{"SOURCE_ROW_NUMBER":"1221777","VIOLATION_NO":"7604030","ISSUE_DT":"07/20/2000","CFR_STANDARD_CD":"77.200","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"340.00","CURRENT_ASSESSMENT_AMT":"340.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-07-20"},{"SOURCE_ROW_NUMBER":"1221776","VIOLATION_NO":"7604029","ISSUE_DT":"07/20/2000","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-07-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":4,"firstDate":"2001-02-06","lastDate":"2001-07-03","metrics":{"appeals":0,"decisions":4,"recentRows":0,"decisionPenalty":283,"originalPenalty":720},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"468499","VIOLATION_NO":"7603157","DOCKET_NO":"WEST20010277","DECISION_DT":"07/03/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"92.00","DECISION_PENALTY_AMT":"55.00","JUDGE_FIRST_NAME":"August","JUDGE_LAST_NAME":"Cetti","sourceDate":"2001-07-03"},{"SOURCE_ROW_NUMBER":"172113","VIOLATION_NO":"7603154","DOCKET_NO":"WEST20010277","DECISION_DT":"07/03/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"92.00","DECISION_PENALTY_AMT":"55.00","JUDGE_FIRST_NAME":"August","JUDGE_LAST_NAME":"Cetti","sourceDate":"2001-07-03"},{"SOURCE_ROW_NUMBER":"469310","VIOLATION_NO":"7603184","DOCKET_NO":"WEST20000317","DECISION_DT":"02/06/2001","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"294.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"August","JUDGE_LAST_NAME":"Cetti","sourceDate":"2001-02-06"},{"SOURCE_ROW_NUMBER":"467947","VIOLATION_NO":"7602874","DOCKET_NO":"WEST20000317","DECISION_DT":"02/06/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"242.00","DECISION_PENALTY_AMT":"173.00","JUDGE_FIRST_NAME":"August","JUDGE_LAST_NAME":"Cetti","sourceDate":"2001-02-06"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":99,"firstDate":"2000-01-10","lastDate":"2000-12-13","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":7,"validSamples":92,"maxConcentration":3.806,"concentrationTotal":77.662},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1339027","CASS_NUM":"50494664","SMP_TAKEN_DT":"12/13/2000","CONC":".421","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-13"},{"SOURCE_ROW_NUMBER":"1553026","CASS_NUM":"50494647","SMP_TAKEN_DT":"12/12/2000","CONC":"1.053","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-12"},{"SOURCE_ROW_NUMBER":"774821","CASS_NUM":"50494622","SMP_TAKEN_DT":"12/12/2000","CONC":"1.411","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-12"},{"SOURCE_ROW_NUMBER":"1290582","CASS_NUM":"50494686","SMP_TAKEN_DT":"12/6/2000","CONC":"1.881","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-06"},{"SOURCE_ROW_NUMBER":"1462024","CASS_NUM":"57272966","SMP_TAKEN_DT":"11/30/2000","CONC":".415","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OUTSIDE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"382820","CASS_NUM":"57272942","SMP_TAKEN_DT":"11/30/2000","CONC":".385","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"420715","CASS_NUM":"50494699","SMP_TAKEN_DT":"11/29/2000","CONC":"2.044","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-11-29"},{"SOURCE_ROW_NUMBER":"1471979","CASS_NUM":"50495068","SMP_TAKEN_DT":"11/28/2000","CONC":".912","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-11-28"},{"SOURCE_ROW_NUMBER":"619001","CASS_NUM":"50494697","SMP_TAKEN_DT":"11/28/2000","CONC":"1.578","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-11-28"},{"SOURCE_ROW_NUMBER":"402620","CASS_NUM":"50495088","SMP_TAKEN_DT":"11/13/2000","CONC":"1.358","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"96494","CASS_NUM":"50495085","SMP_TAKEN_DT":"11/13/2000","CONC":".192","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"1525231","CASS_NUM":"57118516","SMP_TAKEN_DT":"10/26/2000","CONC":".43","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-10-26"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2000-08-16","lastDate":"2000-08-16","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1979-08-01","lastDate":"1985-03-22","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":23,"firstDate":"2000-01-04","lastDate":"2001-01-23","metrics":{"inspectors":26,"recentRows":0,"onSiteHours":223.5,"inspectionHours":524.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"305077","EVENT_NO":"6168436","INSPECTION_BEGIN_DT":"01/23/2001","INSPECTION_END_DT":"01/23/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"687483","EVENT_NO":"4263503","INSPECTION_BEGIN_DT":"11/30/2000","INSPECTION_END_DT":"12/04/2000","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"1122494","EVENT_NO":"4264865","INSPECTION_BEGIN_DT":"10/24/2000","INSPECTION_END_DT":"11/22/2000","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2000-10-24"},{"SOURCE_ROW_NUMBER":"746336","EVENT_NO":"4264866","INSPECTION_BEGIN_DT":"10/24/2000","INSPECTION_END_DT":"12/15/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"79.5","SUM_TOTAL_ON_SITE_HOURS":"34","sourceDate":"2000-10-24"},{"SOURCE_ROW_NUMBER":"757391","EVENT_NO":"5961200","INSPECTION_BEGIN_DT":"09/21/2000","INSPECTION_END_DT":"09/22/2000","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2000-09-21"},{"SOURCE_ROW_NUMBER":"1013462","EVENT_NO":"4264852","INSPECTION_BEGIN_DT":"08/23/2000","INSPECTION_END_DT":"09/12/2000","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2000-08-23"},{"SOURCE_ROW_NUMBER":"731099","EVENT_NO":"4263000","INSPECTION_BEGIN_DT":"08/23/2000","INSPECTION_END_DT":"09/14/2000","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2000-08-23"},{"SOURCE_ROW_NUMBER":"833050","EVENT_NO":"4263175","INSPECTION_BEGIN_DT":"07/18/2000","INSPECTION_END_DT":"09/14/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"83","SUM_TOTAL_ON_SITE_HOURS":"35.5","sourceDate":"2000-07-18"},{"SOURCE_ROW_NUMBER":"583174","EVENT_NO":"5518998","INSPECTION_BEGIN_DT":"07/05/2000","INSPECTION_END_DT":"07/06/2000","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2000-07-05"},{"SOURCE_ROW_NUMBER":"980494","EVENT_NO":"4263173","INSPECTION_BEGIN_DT":"06/28/2000","INSPECTION_END_DT":"06/30/2000","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2000-06-28"},{"SOURCE_ROW_NUMBER":"917734","EVENT_NO":"4263172","INSPECTION_BEGIN_DT":"06/28/2000","INSPECTION_END_DT":"06/30/2000","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2000-06-28"},{"SOURCE_ROW_NUMBER":"974247","EVENT_NO":"4262978","INSPECTION_BEGIN_DT":"05/30/2000","INSPECTION_END_DT":"06/12/2000","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2000-05-30"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":19,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001-Q2":{"hours":1807,"employees":5,"production":0},"2001-Q1":{"hours":3099,"employees":6,"production":562},"2000-Q4":{"hours":12403,"employees":34,"production":45337},"2000-Q3":{"hours":18990,"employees":37,"production":47449},"2000-Q2":{"hours":17538,"employees":38,"production":54370},"2000-Q1":{"hours":21646,"employees":40,"production":49772}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":70577,"employees":38,"production":196928},"2001":{"hours":4906,"employees":6,"production":562}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":2,"firstDate":"2000-03-14","lastDate":"2000-03-14","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":225,"pelDoseTotal":197},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"14573","EVENT_NO":"4262958","SURVEY_DATE":"03/14/2000","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"127","PEL_DOSE_90":"127","SURVEY_TYPE":"I","sourceDate":"2000-03-14"},{"SOURCE_ROW_NUMBER":"14572","EVENT_NO":"4262958","SURVEY_DATE":"03/14/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"98","PEL_DOSE_90":"70","SURVEY_TYPE":"I","sourceDate":"2000-03-14"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":4,"firstDate":"2000-03-14","lastDate":"2000-05-31","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":6.5,"validSamples":4,"quartzPctTotal":17.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"92365","CASSETTE_NO":"57174075","SAMPLE_DT":"05/31/2000","QUARTZ_PCT":"04.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-05-31"},{"SOURCE_ROW_NUMBER":"163761","CASSETTE_NO":"50523120","SAMPLE_DT":"05/03/2000","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-05-03"},{"SOURCE_ROW_NUMBER":"167370","CASSETTE_NO":"50523089","SAMPLE_DT":"04/06/2000","QUARTZ_PCT":"03.5","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-04-06"},{"SOURCE_ROW_NUMBER":"127970","CASSETTE_NO":"57168918","SAMPLE_DT":"03/14/2000","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-03-14"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":90,"firstDate":"2000-01-05","lastDate":"2000-12-13","metrics":{"ss":16,"amountDue":30829,"contested":4,"amountPaid":30829,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":31266},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"294480","VIOLATION_NO":"7626758","VIOLATION_ISSUE_DT":"12/13/2000","SIG_SUB":"N","PART_SECTION":"75.333(c)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/13/2000","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"340","CONTESTED_IND":"N","sourceDate":"2000-12-13"},{"SOURCE_ROW_NUMBER":"294479","VIOLATION_NO":"7603158","VIOLATION_ISSUE_DT":"11/30/2000","SIG_SUB":"N","PART_SECTION":"48.31(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2000","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"340","CONTESTED_IND":"N","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"294478","VIOLATION_NO":"7603157","VIOLATION_ISSUE_DT":"11/30/2000","SIG_SUB":"N","PART_SECTION":"48.31(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2000","PROPOSED_PENALTY":"92","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"Y","DOCKET_NO":"WEST20010277","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"294477","VIOLATION_NO":"7603156","VIOLATION_ISSUE_DT":"11/30/2000","SIG_SUB":"Y","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2000","PROPOSED_PENALTY":"66","AMOUNT_DUE":"66","AMOUNT_PAID":"66","CONTESTED_IND":"N","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"294476","VIOLATION_NO":"7603155","VIOLATION_ISSUE_DT":"11/30/2000","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/30/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"294475","VIOLATION_NO":"7603154","VIOLATION_ISSUE_DT":"11/30/2000","SIG_SUB":"N","PART_SECTION":"48.31(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2000","PROPOSED_PENALTY":"92","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"Y","DOCKET_NO":"WEST20010277","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"294474","VIOLATION_NO":"7603153","VIOLATION_ISSUE_DT":"11/30/2000","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2000","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"340","CONTESTED_IND":"N","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"294473","VIOLATION_NO":"7603152","VIOLATION_ISSUE_DT":"11/30/2000","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/30/2000","PROPOSED_PENALTY":"242","AMOUNT_DUE":"242","AMOUNT_PAID":"242","CONTESTED_IND":"N","sourceDate":"2000-11-30"},{"SOURCE_ROW_NUMBER":"294481","VIOLATION_NO":"7636293","VIOLATION_ISSUE_DT":"10/26/2000","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/26/2000","PROPOSED_PENALTY":"399","AMOUNT_DUE":"399","AMOUNT_PAID":"399","CONTESTED_IND":"N","sourceDate":"2000-10-26"},{"SOURCE_ROW_NUMBER":"294472","VIOLATION_NO":"7604031","VIOLATION_ISSUE_DT":"07/20/2000","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2000","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"340","CONTESTED_IND":"N","sourceDate":"2000-07-20"},{"SOURCE_ROW_NUMBER":"294471","VIOLATION_NO":"7604030","VIOLATION_ISSUE_DT":"07/20/2000","SIG_SUB":"N","PART_SECTION":"77.200","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/24/2000","PROPOSED_PENALTY":"340","AMOUNT_DUE":"340","AMOUNT_PAID":"340","CONTESTED_IND":"N","sourceDate":"2000-07-20"},{"SOURCE_ROW_NUMBER":"294470","VIOLATION_NO":"7604029","VIOLATION_ISSUE_DT":"07/20/2000","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-07-20"}]}],"safety":{"href":"/api/v1/mines/0503455/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/0503455/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Hazard training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.31","part":"48","subchapter":"H","subpart":"B","id":"48.31","citation":"30 CFR 48.31","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Surface installations; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.200","part":"77","subchapter":"O","subpart":"C","id":"77.200","citation":"30 CFR 77.200","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"0503455","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}