{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"0103422","name":"Clark No 1 Mine","status":"Abandoned and Sealed","status_date":"2016-06-29","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"AL","county":"Shelby","nearest_town":"Montevallo","operator_id":"0126573","operator_name":"Jesse Creek Mining LLC","controller_id":"0101481","controller_name":"Piney Woods Resources, Inc","district":"M3","office":"Birmingham AL Field Office (A)","employees":0,"latitude":33.198056,"longitude":-86.942778},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":3062},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"0103422","name":"Clark No 1 Mine"},"operator":{"type":"operator","id":"0126573","name":"Jesse Creek Mining LLC"},"controller":{"type":"controller","id":"0101481","name":"Piney Woods Resources, Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15962","name":"Daryn M  Bookout et al"},"object":{"type":"mine","id":"0103422","name":"Clark No 1 Mine"},"validFrom":"2005-09-15","validTo":"2011-09-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103422|C15962|2005-09-15|2011-09-07"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0065625","name":"Tacoa Minerals LLC"},"object":{"type":"mine","id":"0103422","name":"Clark No 1 Mine"},"validFrom":"2009-11-11","validTo":"2013-01-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103422|0065625|2009-11-11|2013-01-27"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15962","name":"Daryn M  Bookout et al"},"object":{"type":"operator","id":"0065625","name":"Tacoa Minerals LLC"},"validFrom":"2009-11-11","validTo":"2011-09-07","current":false,"derived":true,"evidenceMineId":"0103422","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103422|0065625|2009-11-11|C15962|2005-09-15|97860"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15962","name":"Jerry C  Whitt et al"},"object":{"type":"operator","id":"0065625","name":"Tacoa Minerals LLC"},"validFrom":"2009-11-11","validTo":"2011-09-07","current":false,"derived":true,"evidenceMineId":"0103422","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103422|0065625|2009-11-11|C15962|2005-09-15|97861"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0101481","name":"Piney Woods Resources, Inc"},"object":{"type":"mine","id":"0103422","name":"Clark No 1 Mine"},"validFrom":"2011-09-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103422|0101481|2011-09-08|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0101481","name":"Piney Woods Resources, Inc"},"object":{"type":"operator","id":"0065625","name":"Tacoa Minerals LLC"},"validFrom":"2011-09-08","validTo":"2013-01-27","current":false,"derived":true,"evidenceMineId":"0103422","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103422|0065625|2009-11-11|0101481|2011-09-08|17260"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0126573","name":"Jesse Creek Mining LLC"},"object":{"type":"mine","id":"0103422","name":"Clark No 1 Mine"},"validFrom":"2013-01-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103422|0126573|2013-01-28|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0101481","name":"Piney Woods Resources, Inc"},"object":{"type":"mine","id":"0103422","name":"Clark No 1 Mine"},"validFrom":"2013-01-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103422|0101481|2013-01-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0101481","name":"Piney Woods Resources, Inc"},"object":{"type":"operator","id":"0126573","name":"Jesse Creek Mining LLC"},"validFrom":"2013-01-28","validTo":null,"current":true,"derived":true,"evidenceMineId":"0103422","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103422|0126573|2013-01-28|0101481|2013-01-28|17267"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":65,"firstDate":"2011-01-13","lastDate":"2015-12-09","metrics":{"daysLost":730,"injuries":50,"fatalities":0,"recentRows":0,"restrictedDays":129,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"155005","DOCUMENT_NO":"220153500028","ACCIDENT_DT":"12/09/2015","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall occurred on MMU-001 located at spad 408 in the number 2 entry 2 feet above the anchorage point.","sourceDate":"2015-12-09"},{"SOURCE_ROW_NUMBER":"103150","DOCUMENT_NO":"220152790003","ACCIDENT_DT":"09/27/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was cutting belt to be used as guard for feeder batwing. He was cutting belt when his knife slipped and cut his hand. Employee had gloves on but was cut between thumb and index finger. He was given first aid onsite and transported to Shelby County hospital. He received three stitches.","sourceDate":"2015-09-27"},{"SOURCE_ROW_NUMBER":"197901","DOCUMENT_NO":"220152450067","ACCIDENT_DT":"08/26/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was throwing cribs to stack, and mashed his finger between blocks.","sourceDate":"2015-08-26"},{"SOURCE_ROW_NUMBER":"202260","DOCUMENT_NO":"220152240027","ACCIDENT_DT":"08/10/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating the Fair Child 35-AC Scoop on the haul road near the #2 belt drive. When a tire ran over a bridge board, the block flipped up, hitting his left hand and smashing his pinkie finger.","sourceDate":"2015-08-10"},{"SOURCE_ROW_NUMBER":"219588","DOCUMENT_NO":"220151960031","ACCIDENT_DT":"07/05/2015","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall above anchorage occurred on the main haul road between break number 2 and break number 3 on number 2 belt. The fall occurred at survey station number 2932 in the number 3 entry. Be advised that no one was injured at the time of the fall.","sourceDate":"2015-07-05"},{"SOURCE_ROW_NUMBER":"94611","DOCUMENT_NO":"220151120015","ACCIDENT_DT":"04/19/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured was attempting to drag a piece of shuttle car cable across the section tailpiece when his foot slipped on loose material causing him to strike his left upper thigh against the belt structure.  This resulted in an approximately two inch laceration.  He was treated at the mine and taken to the hospital where the wound was closed with nine stitches","sourceDate":"2015-04-19"},{"SOURCE_ROW_NUMBER":"128932","DOCUMENT_NO":"220150430003","ACCIDENT_DT":"02/05/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured was assisting in hanging an air pump from a roof bolt when the pump slipped.  A sharp burr on the cut off handle cut his left hand.  He went to the doctor and received five stitches.","sourceDate":"2015-02-05"},{"SOURCE_ROW_NUMBER":"236778","DOCUMENT_NO":"220150410007","ACCIDENT_DT":"01/23/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"362","NARRATIVE":"Injured pulled the diesel mantrip underground to park in the first crosscut inby the drift.  As he attempted to back into the crosscut, he shifted from forward to reverse but missed reverse putting the mantrip in neutral.  The mantrip took off down-dip to #5 crosscut where it struck a steel set.  Injured had a laceration to his forehead but unknown exactly what he struck.","sourceDate":"2015-01-23"},{"SOURCE_ROW_NUMBER":"81920","DOCUMENT_NO":"220150410023","ACCIDENT_DT":"01/19/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Injured was bolting the mine roof when his drill steel became fouled in the roof.  As he was attempting to remove the steel, a piece of roof (3' X 2') fell striking his head and shoulder.  He finished his shift and went home.","sourceDate":"2015-01-19"},{"SOURCE_ROW_NUMBER":"107390","DOCUMENT_NO":"220152080015","ACCIDENT_DT":"01/17/2015","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"The employee was operating a diesel powered, rubber tired, man trip on an incline underground . He was negotiating a turn which required him to back up and go forward in order to make the turn & then lost control. His legs were bruised. EMS transported him to hospital and he was released.","sourceDate":"2015-01-17"},{"SOURCE_ROW_NUMBER":"116089","DOCUMENT_NO":"220143450040","ACCIDENT_DT":"12/10/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The employee was utilizing a utility knife to trim a piece of belt when his hand inadvertently slipped and cut his left hand. The laceration was 2.5 inches long and better than 1/4 inch deep. He received 5 sutures in order to close the wound. He was treated and released to  full duty.","sourceDate":"2014-12-10"},{"SOURCE_ROW_NUMBER":"210914","DOCUMENT_NO":"220142890011","ACCIDENT_DT":"10/14/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall occurred above the anchorage zone in the left mine return 8 breaks underground from the fan duct work .","sourceDate":"2014-10-14"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2016-06-29","lastDate":"2016-06-29","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":375,"firstDate":"2010-05-13","lastDate":"2015-12-21","metrics":{"ss":164,"delinquent":374,"recentRows":0,"paidPenalty":289530,"proposedPenalty":374459,"currentAssessment":289530},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1584390","VIOLATION_NO":"8531036","ISSUE_DT":"12/21/2015","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-12-21"},{"SOURCE_ROW_NUMBER":"1584379","VIOLATION_NO":"8526900","ISSUE_DT":"12/21/2015","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-12-21"},{"SOURCE_ROW_NUMBER":"1584391","VIOLATION_NO":"8531116","ISSUE_DT":"12/18/2015","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-12-18"},{"SOURCE_ROW_NUMBER":"1584398","VIOLATION_NO":"8531115","ISSUE_DT":"12/10/2015","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-12-10"},{"SOURCE_ROW_NUMBER":"1584395","VIOLATION_NO":"8532202","ISSUE_DT":"12/09/2015","CFR_STANDARD_CD":"70.206(e)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-12-09"},{"SOURCE_ROW_NUMBER":"1584394","VIOLATION_NO":"8532201","ISSUE_DT":"12/09/2015","CFR_STANDARD_CD":"70.206(e)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-12-09"},{"SOURCE_ROW_NUMBER":"1584389","VIOLATION_NO":"8531031","ISSUE_DT":"11/03/2015","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2106.00","CURRENT_ASSESSMENT_AMT":"2106.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"1584388","VIOLATION_NO":"8531030","ISSUE_DT":"11/03/2015","CFR_STANDARD_CD":"75.1909(b)(5)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"1584387","VIOLATION_NO":"8531029","ISSUE_DT":"11/03/2015","CFR_STANDARD_CD":"75.1909(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"1584386","VIOLATION_NO":"8531028","ISSUE_DT":"11/03/2015","CFR_STANDARD_CD":"75.1907(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"1584393","VIOLATION_NO":"8531914","ISSUE_DT":"10/14/2015","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"1584392","VIOLATION_NO":"8531913","ISSUE_DT":"10/14/2015","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-14"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":48,"firstDate":"2013-03-29","lastDate":"2018-02-21","metrics":{"appeals":0,"decisions":48,"recentRows":0,"decisionPenalty":145575,"originalPenalty":230504},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"374041","VIOLATION_NO":"8530766","DOCKET_NO":"SE 2015-0310","DECISION_DT":"02/21/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"447.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2018-02-21"},{"SOURCE_ROW_NUMBER":"374040","VIOLATION_NO":"8530761","DOCKET_NO":"SE 2015-0310","DECISION_DT":"02/21/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"351.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2018-02-21"},{"SOURCE_ROW_NUMBER":"373529","VIOLATION_NO":"8530765","DOCKET_NO":"SE 2015-0310","DECISION_DT":"02/21/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"917.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2018-02-21"},{"SOURCE_ROW_NUMBER":"115406","VIOLATION_NO":"8530762","DOCKET_NO":"SE 2015-0310","DECISION_DT":"02/21/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"1077.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2018-02-21"},{"SOURCE_ROW_NUMBER":"376870","VIOLATION_NO":"8529562","DOCKET_NO":"SE 2016-43","DECISION_DT":"12/20/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"1000.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2017-12-20"},{"SOURCE_ROW_NUMBER":"376644","VIOLATION_NO":"8530327","DOCKET_NO":"SE 2016-43","DECISION_DT":"12/20/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"12500.00","DECISION_PENALTY_AMT":"7000.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2017-12-20"},{"SOURCE_ROW_NUMBER":"376391","VIOLATION_NO":"8530332","DOCKET_NO":"SE 2016-43","DECISION_DT":"12/20/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"21900.00","DECISION_PENALTY_AMT":"18650.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2017-12-20"},{"SOURCE_ROW_NUMBER":"375533","VIOLATION_NO":"8526893","DOCKET_NO":"SE 2016-43","DECISION_DT":"12/20/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"200.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2017-12-20"},{"SOURCE_ROW_NUMBER":"117459","VIOLATION_NO":"8530338","DOCKET_NO":"SE 2016-43","DECISION_DT":"12/20/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"21900.00","DECISION_PENALTY_AMT":"18650.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2017-12-20"},{"SOURCE_ROW_NUMBER":"117458","VIOLATION_NO":"8530334","DOCKET_NO":"SE 2016-43","DECISION_DT":"12/20/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"25800.00","DECISION_PENALTY_AMT":"10500.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2017-12-20"},{"SOURCE_ROW_NUMBER":"117012","VIOLATION_NO":"8530342","DOCKET_NO":"SE 2016-43","DECISION_DT":"12/20/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"28800.00","DECISION_PENALTY_AMT":"14000.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2017-12-20"},{"SOURCE_ROW_NUMBER":"117718","VIOLATION_NO":"8531422","DOCKET_NO":"SE 2016-0020","DECISION_DT":"09/20/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"400.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2016-09-20"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":748,"firstDate":"2010-06-22","lastDate":"2015-12-02","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":285,"validSamples":463,"maxConcentration":58.349,"concentrationTotal":521.829},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1312132","CASS_NUM":"51413964","SMP_TAKEN_DT":"12/2/2015","CONC":".26","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DA NOT IN PRODUCING STATUS","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-12-02"},{"SOURCE_ROW_NUMBER":"1567591","CASS_NUM":"58249912","SMP_TAKEN_DT":"11/17/2015","CONC":".36","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"1504267","CASS_NUM":"58249911","SMP_TAKEN_DT":"11/17/2015","CONC":".308","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"1473819","CASS_NUM":"58249537","SMP_TAKEN_DT":"11/17/2015","CONC":".819","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"1434221","CASS_NUM":"58249896","SMP_TAKEN_DT":"11/17/2015","CONC":".469","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"1424675","CASS_NUM":"58249700","SMP_TAKEN_DT":"11/17/2015","CONC":".217","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"1087292","CASS_NUM":"58249521","SMP_TAKEN_DT":"11/17/2015","CONC":".476","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"1044570","CASS_NUM":"58249974","SMP_TAKEN_DT":"11/17/2015","CONC":".3","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"870858","CASS_NUM":"58249536","SMP_TAKEN_DT":"11/17/2015","CONC":".337","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"477424","CASS_NUM":"58249809","SMP_TAKEN_DT":"11/17/2015","CONC":".547","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"477423","CASS_NUM":"58249630","SMP_TAKEN_DT":"11/17/2015","CONC":".426","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"237115","CASS_NUM":"58249965","SMP_TAKEN_DT":"11/17/2015","CONC":".224","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-17"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":17,"firstDate":"2011-05-17","lastDate":"2015-04-14","metrics":{"linkedIssuances":17},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":48,"firstDate":"2011-04-07","lastDate":"2015-11-03","metrics":{"decisions":48,"ssChanged":12,"recentRows":0,"decisionPenalty":145575,"proposedPenalty":230504},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"378200","CITATION_NO":"8531030","CITATION_ISSUE_DT":"11/03/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.1909(b)(5)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"321062","CITATION_NO":"8531028","CITATION_ISSUE_DT":"11/03/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.1907(b)(2)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"208474","CITATION_NO":"8531029","CITATION_ISSUE_DT":"11/03/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.1909(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"208289","CITATION_NO":"8531031","CITATION_ISSUE_DT":"11/03/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"2106.00","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"433316","CITATION_NO":"8530623","CITATION_ISSUE_DT":"10/14/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"433187","CITATION_NO":"8530622","CITATION_ISSUE_DT":"10/14/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.380(d)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"162.00","DECISION_PENALTY_AMT":"162.00","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"381349","CITATION_NO":"8531913","CITATION_ISSUE_DT":"10/14/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"378170","CITATION_NO":"8528977","CITATION_ISSUE_DT":"10/14/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"319781","CITATION_NO":"8530090","CITATION_ISSUE_DT":"10/14/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.904","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"149700","CITATION_NO":"8528978","CITATION_ISSUE_DT":"10/14/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.1100-1","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"540.00","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"95644","CITATION_NO":"8531914","CITATION_ISSUE_DT":"10/14/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.904","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"38649","CITATION_NO":"8530621","CITATION_ISSUE_DT":"10/14/2015","DOCKET_NO":"SE 2016-0100","DECISION_DT":"06/01/2016","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2015-10-14"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":859,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":197,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2009-11-11","lastDate":"2013-01-28","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":152,"firstDate":"2010-01-26","lastDate":"2016-04-07","metrics":{"inspectors":287,"recentRows":0,"onSiteHours":3377,"inspectionHours":5211,"inspectionSamples":396},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"42416","EVENT_NO":"4498545","INSPECTION_BEGIN_DT":"04/07/2016","INSPECTION_END_DT":"06/28/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"29","SUM_TOTAL_ON_SITE_HOURS":"17","sourceDate":"2016-04-07"},{"SOURCE_ROW_NUMBER":"981770","EVENT_NO":"4497851","INSPECTION_BEGIN_DT":"01/05/2016","INSPECTION_END_DT":"03/31/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"56.5","SUM_TOTAL_ON_SITE_HOURS":"32.5","sourceDate":"2016-01-05"},{"SOURCE_ROW_NUMBER":"1078276","EVENT_NO":"4498613","INSPECTION_BEGIN_DT":"12/09/2015","INSPECTION_END_DT":"12/18/2015","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"34","SUM_TOTAL_ON_SITE_HOURS":"14.5","sourceDate":"2015-12-09"},{"SOURCE_ROW_NUMBER":"689053","EVENT_NO":"6492025","INSPECTION_BEGIN_DT":"11/22/2015","INSPECTION_END_DT":"11/22/2015","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2015-11-22"},{"SOURCE_ROW_NUMBER":"1015501","EVENT_NO":"4496297","INSPECTION_BEGIN_DT":"11/05/2015","INSPECTION_END_DT":"11/05/2015","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2015-11-05"},{"SOURCE_ROW_NUMBER":"1130914","EVENT_NO":"4496292","INSPECTION_BEGIN_DT":"10/16/2015","INSPECTION_END_DT":"10/16/2015","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2015-10-16"},{"SOURCE_ROW_NUMBER":"394140","EVENT_NO":"4498133","INSPECTION_BEGIN_DT":"10/07/2015","INSPECTION_END_DT":"10/07/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2015-10-07"},{"SOURCE_ROW_NUMBER":"164748","EVENT_NO":"4498610","INSPECTION_BEGIN_DT":"10/05/2015","INSPECTION_END_DT":"12/28/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"13","SUM_TOTAL_INSP_HOURS":"335.5","SUM_TOTAL_ON_SITE_HOURS":"232.5","sourceDate":"2015-10-05"},{"SOURCE_ROW_NUMBER":"440642","EVENT_NO":"4498132","INSPECTION_BEGIN_DT":"10/02/2015","INSPECTION_END_DT":"10/02/2015","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2015-10-02"},{"SOURCE_ROW_NUMBER":"136189","EVENT_NO":"4498444","INSPECTION_BEGIN_DT":"09/10/2015","INSPECTION_END_DT":"09/10/2015","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2015-09-10"},{"SOURCE_ROW_NUMBER":"623757","EVENT_NO":"4497399","INSPECTION_BEGIN_DT":"07/27/2015","INSPECTION_END_DT":"07/27/2015","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"966029","EVENT_NO":"4497397","INSPECTION_BEGIN_DT":"07/06/2015","INSPECTION_END_DT":"09/24/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"253.75","SUM_TOTAL_ON_SITE_HOURS":"186.25","sourceDate":"2015-07-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":41,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2016-Q2":{"hours":2592,"employees":22,"production":0},"2016-Q1":{"hours":12834,"employees":23,"production":4011},"2015-Q4":{"hours":87792,"employees":97,"production":32742},"2015-Q3":{"hours":71397,"employees":96,"production":39616},"2015-Q2":{"hours":68584,"employees":88,"production":32122},"2015-Q1":{"hours":38882,"employees":72,"production":33921},"2014-Q4":{"hours":43283,"employees":59,"production":29533},"2014-Q3":{"hours":47320,"employees":64,"production":32027},"2014-Q2":{"hours":47148,"employees":64,"production":50768},"2014-Q1":{"hours":44757,"employees":66,"production":52201},"2013-Q4":{"hours":42249,"employees":75,"production":32737},"2013-Q3":{"hours":38491,"employees":65,"production":37104}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2010":{"hours":55853,"employees":37,"production":12819},"2011":{"hours":118953,"employees":49,"production":66264},"2012":{"hours":127254,"employees":53,"production":20294},"2013":{"hours":140250,"employees":63,"production":122727},"2014":{"hours":182508,"employees":63,"production":164529},"2015":{"hours":266655,"employees":88,"production":138401},"2016":{"hours":15426,"employees":23,"production":4011}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":60,"firstDate":"2011-09-14","lastDate":"2015-08-26","metrics":{"recentRows":0,"doseOver100":7,"actDoseTotal":3663,"pelDoseTotal":2739},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"11901","EVENT_NO":"4497397","SURVEY_DATE":"08/26/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"101","PEL_DOSE_90":"87","SURVEY_TYPE":"F","sourceDate":"2015-08-26"},{"SOURCE_ROW_NUMBER":"11902","EVENT_NO":"4497397","SURVEY_DATE":"07/22/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"153","PEL_DOSE_90":"136","SURVEY_TYPE":"I","sourceDate":"2015-07-22"},{"SOURCE_ROW_NUMBER":"11900","EVENT_NO":"4497397","SURVEY_DATE":"07/22/2015","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"69","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2015-07-22"},{"SOURCE_ROW_NUMBER":"11899","EVENT_NO":"4497397","SURVEY_DATE":"07/22/2015","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"59","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2015-07-22"},{"SOURCE_ROW_NUMBER":"11898","EVENT_NO":"4497397","SURVEY_DATE":"07/22/2015","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2015-07-22"},{"SOURCE_ROW_NUMBER":"11897","EVENT_NO":"4497397","SURVEY_DATE":"07/22/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"119","ACT_DOSE_85":"121","PEL_DOSE_90":"105","SURVEY_TYPE":"I","sourceDate":"2015-07-22"},{"SOURCE_ROW_NUMBER":"11896","EVENT_NO":"4497397","SURVEY_DATE":"07/22/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"105","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2015-07-22"},{"SOURCE_ROW_NUMBER":"11909","EVENT_NO":"4498115","SURVEY_DATE":"10/21/2014","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"66","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2014-10-21"},{"SOURCE_ROW_NUMBER":"11908","EVENT_NO":"4498115","SURVEY_DATE":"10/21/2014","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"56","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2014-10-21"},{"SOURCE_ROW_NUMBER":"11907","EVENT_NO":"4498115","SURVEY_DATE":"10/21/2014","OCCUPATION_CD_DESC":"ELECTRICIAN","ACT_DOSE_85":"25","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2014-10-21"},{"SOURCE_ROW_NUMBER":"11906","EVENT_NO":"4498115","SURVEY_DATE":"10/21/2014","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"40","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2014-10-21"},{"SOURCE_ROW_NUMBER":"11905","EVENT_NO":"4498115","SURVEY_DATE":"10/21/2014","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"33","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2014-10-21"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":39,"firstDate":"2011-03-08","lastDate":"2015-11-17","metrics":{"recentRows":0,"voidSamples":4,"maxQuartzPct":42.3,"validSamples":35,"quartzPctTotal":313.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"57441","CASSETTE_NO":"58249537","SAMPLE_DT":"11/17/2015","QUARTZ_PCT":"08.8","QUARTZ_MICROGRAMS":"72","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"28887","CASSETTE_NO":"58249809","SAMPLE_DT":"11/17/2015","QUARTZ_PCT":"07.3","QUARTZ_MICROGRAMS":"39","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-11-17"},{"SOURCE_ROW_NUMBER":"49402","CASSETTE_NO":"58245781","SAMPLE_DT":"09/02/2015","QUARTZ_PCT":"09.4","QUARTZ_MICROGRAMS":"45","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-09-02"},{"SOURCE_ROW_NUMBER":"131400","CASSETTE_NO":"58249480","SAMPLE_DT":"08/26/2015","QUARTZ_PCT":"06.1","QUARTZ_MICROGRAMS":"19","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-08-26"},{"SOURCE_ROW_NUMBER":"85143","CASSETTE_NO":"58249355","SAMPLE_DT":"08/18/2015","QUARTZ_PCT":"07.2","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-08-18"},{"SOURCE_ROW_NUMBER":"74276","CASSETTE_NO":"58225432","SAMPLE_DT":"06/02/2015","QUARTZ_PCT":"04.0","QUARTZ_MICROGRAMS":"19","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-06-02"},{"SOURCE_ROW_NUMBER":"74011","CASSETTE_NO":"58225560","SAMPLE_DT":"06/02/2015","QUARTZ_PCT":"03.6","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-06-02"},{"SOURCE_ROW_NUMBER":"11734","CASSETTE_NO":"58225433","SAMPLE_DT":"06/02/2015","QUARTZ_PCT":"05.9","QUARTZ_MICROGRAMS":"36","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-06-02"},{"SOURCE_ROW_NUMBER":"50666","CASSETTE_NO":"58196481","SAMPLE_DT":"03/01/2015","QUARTZ_PCT":"04.5","QUARTZ_MICROGRAMS":"34","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-03-01"},{"SOURCE_ROW_NUMBER":"30649","CASSETTE_NO":"58196322","SAMPLE_DT":"03/01/2015","QUARTZ_PCT":"06.1","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-03-01"},{"SOURCE_ROW_NUMBER":"48399","CASSETTE_NO":"58195149","SAMPLE_DT":"10/22/2014","QUARTZ_PCT":"07.1","QUARTZ_MICROGRAMS":"27","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-10-22"},{"SOURCE_ROW_NUMBER":"24845","CASSETTE_NO":"58195142","SAMPLE_DT":"10/22/2014","QUARTZ_PCT":"07.9","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-10-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":395,"firstDate":"2010-05-13","lastDate":"2015-12-21","metrics":{"ss":164,"amountDue":289530,"contested":0,"amountPaid":289530,"recentRows":0,"section104d":11,"unterminated":0,"proposedPenalty":374459},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"94043","VIOLATION_NO":"8531036","VIOLATION_ISSUE_DT":"12/21/2015","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/22/2015","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"585","CONTESTED_IND":"N","sourceDate":"2015-12-21"},{"SOURCE_ROW_NUMBER":"94032","VIOLATION_NO":"8526900","VIOLATION_ISSUE_DT":"12/21/2015","SIG_SUB":"Y","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/21/2015","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"N","sourceDate":"2015-12-21"},{"SOURCE_ROW_NUMBER":"94044","VIOLATION_NO":"8531116","VIOLATION_ISSUE_DT":"12/18/2015","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/18/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-12-18"},{"SOURCE_ROW_NUMBER":"94092","VIOLATION_NO":"8531115","VIOLATION_ISSUE_DT":"12/10/2015","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/18/2015","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"N","sourceDate":"2015-12-10"},{"SOURCE_ROW_NUMBER":"94091","VIOLATION_NO":"8531035","VIOLATION_ISSUE_DT":"12/09/2015","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"12/18/2015","CONTESTED_IND":"N","sourceDate":"2015-12-09"},{"SOURCE_ROW_NUMBER":"94048","VIOLATION_NO":"8532202","VIOLATION_ISSUE_DT":"12/09/2015","SIG_SUB":"N","PART_SECTION":"70.206(e)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/14/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-12-09"},{"SOURCE_ROW_NUMBER":"94047","VIOLATION_NO":"8532201","VIOLATION_ISSUE_DT":"12/09/2015","SIG_SUB":"N","PART_SECTION":"70.206(e)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/14/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-12-09"},{"SOURCE_ROW_NUMBER":"94042","VIOLATION_NO":"8531031","VIOLATION_ISSUE_DT":"11/03/2015","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/04/2015","PROPOSED_PENALTY":"2106","AMOUNT_DUE":"2106","AMOUNT_PAID":"2106","CONTESTED_IND":"N","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"94041","VIOLATION_NO":"8531030","VIOLATION_ISSUE_DT":"11/03/2015","SIG_SUB":"N","PART_SECTION":"75.1909(b)(5)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/03/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"94040","VIOLATION_NO":"8531029","VIOLATION_ISSUE_DT":"11/03/2015","SIG_SUB":"N","PART_SECTION":"75.1909(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/03/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"94039","VIOLATION_NO":"8531028","VIOLATION_ISSUE_DT":"11/03/2015","SIG_SUB":"N","PART_SECTION":"75.1907(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/03/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"94046","VIOLATION_NO":"8531914","VIOLATION_ISSUE_DT":"10/14/2015","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/14/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-10-14"}]}],"safety":{"href":"/api/v1/mines/0103422/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/0103422/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1909","heading":"Nonpermissible diesel-powered equipment; design and performance requirements.","id":"75.1909","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1909","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Nonpermissible diesel-powered equipment, except for the special category of equipment under § 75.1908(d), must be equipped with the following features:\n\n(1) An engine approved under subpart E of part 7 of this title equipped with an air filter sized in accordance with the engine manufacturer's recommendations, and an air filter service indicator set in accordance with the engine manufacturer's recommendations;\n\n(2) At least one portable multipurpose dry chemical type (ABC) fire extinguisher listed or approved by a nationally recognized independent testing laboratory with a 10A:60B:C or higher rating. The fire extinguisher must be located within easy reach of the equipment operator and protected from damage;\n\n(3) A fuel system specifically designed for diesel fuel meeting the following requirements:\n\n(i) A fuel tank and fuel lines that do not leak;\n\n(ii) A fuel tank that is substantially constructed and protected against damage by collision;\n\n(iii) A vent opening that maintains atmospheric pressure in the fuel tank, and that is designed to prevent fuel from splashing out of the vent opening;\n\n(iv) A self-closing filler cap on the fuel tank;\n\n(v) The fuel tank, filler and vent must be located so that leaks or spillage during refueling will not contact hot surfaces;\n\n(vi) Fuel line piping must be either steel-wire reinforced; synthetic elastomer-covered hose suitable for use with diesel fuel that has been tested and has been determined to be fire-resistant by the manufacturer; or metal;\n\n(vii) Fuel line piping must be clamped;\n\n(viii) Primary fuel lines must be located so that fuel line leaks do not contact hot surfaces;\n\n(ix) The fuel lines must be separated from electrical wiring and protected from damage in ordinary use;\n\n(x) A manual shutoff valve must be installed in the fuel system as close as practicable to the tank; and\n\n(xi) A water separator and fuel filter(s) must be provided.\n\n(4) A sensor to monitor the temperature and provide a visual warning of an overheated cylinder head on air-cooled engines;\n\n(5) Guarding to protect fuel, hydraulic, and electric lines when such lines pass near rotating parts or in the event of shaft failure;\n\n(6) Hydraulic tanks, fillers, vents, and lines located to prevent spillage or leaks from contacting hot surfaces;\n\n(7) Reflectors or warning lights mounted on the equipment which can be readily seen in all directions;\n\n(8) A means to direct exhaust gas away from the equipment operator, persons on board the machine, and combustible machine components;\n\n(9) A means to prevent unintentional free and uncontrolled descent of personnel-elevating work platforms; and\n\n(10) A means to prevent the spray from ruptured hydraulic or lubricating oil lines from being ignited by contact with engine exhaust system component surfaces.\n\n(b) Self-propelled nonpermissible diesel-powered equipment must have the following features in addition to those in paragraph (a):\n\n(1) A means to ensure that no stored hydraulic energy that will cause machine articulation is available after the engine is shut down;\n\n(2) A neutral start feature which ensures that engine cranking torque will not be transmitted through the powertrain and cause machine movement on vehicles utilizing fluid power transmissions;\n\n(3) For machines with steering wheels, brake pedals, and accelerator pedals, controls which are of automobile orientation;\n\n(4) An audible warning device conveniently located near the equipment operator;\n\n(5) Lights provided and maintained on both ends of the equipment. Equipment normally operated in both directions must be equipped with headlights for both directions;\n\n(6) Service brakes that act on each wheel of the vehicle and that are designed such that failure of any single component, except the brake actuation pedal or other similar actuation device, must not result in a complete loss of service braking capability;\n\n(7) Service brakes that safely bring the fully loaded vehicle to a complete stop on the maximum grade on which it is operated; and\n\n(8) No device that traps a column of fluid to hold the brake in the applied position shall be installed in any brake system, unless the trapped column of fluid is released when the equipment operator is no longer in contact with the brake activation device.\n\n(c) Self-propelled nonpermissible heavy-duty diesel-powered equipment under § 75.1908(a), except rail-mounted equipment, shall be provided with a supplemental braking system that:\n\n(1) Engages automatically within 5 seconds of the shutdown of the engine;\n\n(2) Safely brings the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(3) Holds the equipment stationary, despite any contraction of brake parts, exhaustion of any nonmechanical source of energy, or leakage;\n\n(4) Releases only by a manual control that does not operate any other equipment function;\n\n(5) Has a means in the equipment operator's compartment to apply the brakes manually without shutting down the engine, and a means to release and reengage the brakes without the engine operating; and\n\n(6) Has a means to ensure that the supplemental braking system is released before the equipment can be trammed, and is designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(d) Self-propelled nonpermissible light-duty diesel-powered equipment under § 75.1908(b), except rail-mounted equipment, must be provided with a parking brake that holds the fully loaded equipment stationary on the maximum grade on which it is operated despite any contraction of the brake parts, exhaustion of any nonmechanical source of energy, or leakage.\n\n(e) The supplemental and park brake systems required by paragraphs (c) and (d) must be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n(f) Self-propelled personnel-elevating work platforms must be provided with a means to ensure that the parking braking system is released before the equipment can be trammed, and must be designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(g) Any nonpermissible equipment that discharges its exhaust directly into a return air course must be provided with a power package approved under subpart F of part 7 of this title.\n\n(h) Self-propelled nonpermissible heavy-duty diesel-powered equipment meeting the requirements of § 75.1908(a) must be provided with an automatic fire suppression system meeting the requirements of § 75.1911.\n\n(i) Self-propelled nonpermissible light-duty diesel-powered equipment meeting the requirements of § 75.1908(b) must be provided with an automatic or manual fire suppression system meeting the requirements of § 75.1911.\n\n(j) Nonpermissible equipment that is not self-propelled must have the following features in addition to those listed in paragraph (a):\n\n(1) A means to prevent inadvertent movement of the equipment when parked;\n\n(2) Safety chains or other suitable secondary connections on equipment that is being towed; and\n\n(3) An automatic fire suppression system meeting the requirements of § 75.1911.\n\n[61 FR 55527, Oct. 25, 1996; 62 FR 34641, June 27, 1997]","occurrenceCount":2},{"chapter":"I","heading":"Diesel-powered equipment intended for use in underground coal mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1907","part":"75","subchapter":"O","subpart":"T","id":"75.1907","citation":"30 CFR 75.1907","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"0103422","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}