{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"0103362","name":"BRC Alabama No. 4 LLC","status":"Abandoned","status_date":"2015-06-04","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"AL","county":"Tuscaloosa","nearest_town":"Brookwood","operator_id":"0126758","operator_name":"BRC Alabama No. 4 LLC","controller_id":"0107723","controller_name":"Steve  Rickmeier","district":"M3","office":"Birmingham AL Field Office (A)","employees":0,"latitude":33.336944,"longitude":-87.322222},"coverage":{"contributingSources":11,"registeredSources":20,"sourceRows":350},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"0103362","name":"BRC Alabama No. 4 LLC"},"operator":{"type":"operator","id":"0126758","name":"BRC Alabama No. 4 LLC"},"controller":{"type":"controller","id":"0107723","name":"Steve  Rickmeier"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0048309","name":"Headwaters Inc"},"object":{"type":"mine","id":"0103362","name":"BRC Alabama No. 4 LLC"},"validFrom":"2005-02-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103362|0048309|2005-02-10|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0058037","name":"Covol Engineered Fuels LC"},"object":{"type":"mine","id":"0103362","name":"BRC Alabama No. 4 LLC"},"validFrom":"2007-04-20","validTo":"2011-12-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103362|0058037|2007-04-20|2011-12-19"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0048309","name":"Headwaters Inc"},"object":{"type":"operator","id":"0058037","name":"Covol Engineered Fuels LC"},"validFrom":"2007-04-20","validTo":"2011-12-19","current":false,"derived":true,"evidenceMineId":"0103362","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103362|0058037|2007-04-20|0048309|2005-02-10|6021"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0120530","name":"Covol Fuels Alabama No.4, LLC"},"object":{"type":"mine","id":"0103362","name":"BRC Alabama No. 4 LLC"},"validFrom":"2011-12-20","validTo":"2013-01-15","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103362|0120530|2011-12-20|2013-01-15"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0048309","name":"Headwaters Inc"},"object":{"type":"mine","id":"0103362","name":"BRC Alabama No. 4 LLC"},"validFrom":"2011-12-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103362|0048309|2011-12-20|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0048309","name":"Headwaters Inc"},"object":{"type":"operator","id":"0120530","name":"Covol Fuels Alabama No.4, LLC"},"validFrom":"2011-12-20","validTo":"2013-01-15","current":false,"derived":true,"evidenceMineId":"0103362","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103362|0120530|2011-12-20|0048309|2011-12-20|6036"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0126758","name":"BRC Alabama No. 4 LLC"},"object":{"type":"mine","id":"0103362","name":"BRC Alabama No. 4 LLC"},"validFrom":"2013-01-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103362|0126758|2013-01-16|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0107723","name":"Steve  Rickmeier et al"},"object":{"type":"mine","id":"0103362","name":"BRC Alabama No. 4 LLC"},"validFrom":"2013-01-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103362|0107723|2013-01-16|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0107723","name":"Steve  Rickmeier et al"},"object":{"type":"operator","id":"0126758","name":"BRC Alabama No. 4 LLC"},"validFrom":"2013-01-16","validTo":null,"current":true,"derived":true,"evidenceMineId":"0103362","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"0103362|0126758|2013-01-16|0107723|2013-01-16|19307"}}],"coverage":{"historyRecords":3,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":9,"firstDate":"2008-10-03","lastDate":"2011-12-27","metrics":{"daysLost":226,"injuries":11,"fatalities":0,"recentRows":0,"restrictedDays":184,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"159305","DOCUMENT_NO":"220120040013","ACCIDENT_DT":"12/27/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Barge/Boat/Dredge/Towbarge/Towboat/Leach operator, Riverman, Deck hand","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee was getting in jon boat, was walking to the rear of the boat to operate the boat motor, employee tried to step on the metal seat to get to the back of boat, when he stepped on the metal seat he slipped, hitting the left side of his torso on the seat/bottom of the boat.","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"68864","DOCUMENT_NO":"220112340024","ACCIDENT_DT":"08/19/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Contact with electrical current","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"30","NARRATIVE":"Employee was working to rewire VFD control box for electric booster station pump. Employee reached inside the VFD circuit box to check the wiring and must have hit a bare wire causing an ignition or spark to occur that caused him to have burns to his face/head/neck/arms.","sourceDate":"2011-08-19"},{"SOURCE_ROW_NUMBER":"13100","DOCUMENT_NO":"220112130022","ACCIDENT_DT":"07/20/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"191","NARRATIVE":"Climbing onto equipment.","sourceDate":"2011-07-20"},{"SOURCE_ROW_NUMBER":"60267","DOCUMENT_NO":"220102070034","ACCIDENT_DT":"07/15/2010","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE was assisting with maintenance on a pump, he was trying to clean around the pump to make it more accessible for other EE's working on pump. Pushed shovel to dig and when it stopped against surrounding material, his weight shifted against shovel and lost balance. His body weight shifted, felt pull in his leg. Trouble with leg due to prior injury not related to work.","sourceDate":"2010-07-15"},{"SOURCE_ROW_NUMBER":"185131","DOCUMENT_NO":"220090890058","ACCIDENT_DT":"03/19/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Assayer, Geologist, Metallurgist, Engineer, Engineer management","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The john boat floor was slippery as water had accumulated in the bottom at one side of the boat.","sourceDate":"2009-03-19"},{"SOURCE_ROW_NUMBER":"34609","DOCUMENT_NO":"220090780024","ACCIDENT_DT":"03/11/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Belt foreman, Maintenance foreman, Maintenance supervisor","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was examining the air cylinder in the float cell. When he started to come down the ladder, he took a misstep on the ladder which turned his foot sideways causing his knee to pop.","sourceDate":"2009-03-11"},{"SOURCE_ROW_NUMBER":"266833","DOCUMENT_NO":"220090220022","ACCIDENT_DT":"01/15/2009","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"2","DAYS_LOST":"0","NARRATIVE":"Cold weather made the pipe more brittle than normal. Typically the pipe can be cut to a certain point then the pipe can be broken with the equipment to finish the break. Under normal conditions the pipe could have been broken this way. Due to the cold weather making the pipe brittle the amount that was cut was not strong enough to keep from breaking on its own.","sourceDate":"2009-01-15"},{"SOURCE_ROW_NUMBER":"21694","DOCUMENT_NO":"220090220021","ACCIDENT_DT":"01/15/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"2","DAYS_LOST":"1","NARRATIVE":"Cold weather made the pipe more brittle than normal. Typically the pipe can be cut to a certain point then the pipe can be broken with the equipment to finish the break. Under normal conditions the pipe could have been broken this way. Due to the cold weather making the pipe brittle the amount that was cut was not strong enough to keep from breaking on its own.","sourceDate":"2009-01-15"},{"SOURCE_ROW_NUMBER":"241153","DOCUMENT_NO":"220082880080","ACCIDENT_DT":"10/03/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee was working a come-along overhead at the end of his reach.","sourceDate":"2008-10-03"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2015-06-04","lastDate":"2015-06-04","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":37,"firstDate":"2007-11-14","lastDate":"2012-07-05","metrics":{"ss":3,"delinquent":37,"recentRows":0,"paidPenalty":5165,"proposedPenalty":5165,"currentAssessment":5165},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1576888","VIOLATION_NO":"8523870","ISSUE_DT":"07/05/2012","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-05"},{"SOURCE_ROW_NUMBER":"1576887","VIOLATION_NO":"8523869","ISSUE_DT":"07/05/2012","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-05"},{"SOURCE_ROW_NUMBER":"1576399","VIOLATION_NO":"8521051","ISSUE_DT":"10/27/2011","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"1576398","VIOLATION_NO":"8521050","ISSUE_DT":"10/27/2011","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"1576397","VIOLATION_NO":"8521049","ISSUE_DT":"10/27/2011","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"308.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"1576396","VIOLATION_NO":"8521046","ISSUE_DT":"10/19/2011","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"1576395","VIOLATION_NO":"8521045","ISSUE_DT":"10/19/2011","CFR_STANDARD_CD":"77.505","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"308.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"1576394","VIOLATION_NO":"8521044","ISSUE_DT":"10/19/2011","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"308.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"1576369","VIOLATION_NO":"8518097","ISSUE_DT":"04/13/2011","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-04-13"},{"SOURCE_ROW_NUMBER":"1576368","VIOLATION_NO":"8518096","ISSUE_DT":"04/13/2011","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-04-13"},{"SOURCE_ROW_NUMBER":"1576367","VIOLATION_NO":"8518095","ISSUE_DT":"04/13/2011","CFR_STANDARD_CD":"77.210(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-04-13"},{"SOURCE_ROW_NUMBER":"1576366","VIOLATION_NO":"8518094","ISSUE_DT":"04/05/2011","CFR_STANDARD_CD":"77.206(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-04-05"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":66,"firstDate":"2007-09-20","lastDate":"2013-03-13","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":66,"maxConcentration":0.457,"concentrationTotal":6.371},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1567485","CASS_NUM":"58014424","SMP_TAKEN_DT":"3/13/2013","CONC":".041","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"1371572","CASS_NUM":"58014623","SMP_TAKEN_DT":"3/13/2013","CONC":".037","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"1255722","CASS_NUM":"58014625","SMP_TAKEN_DT":"3/13/2013","CONC":".017","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"596152","CASS_NUM":"58014527","SMP_TAKEN_DT":"3/13/2013","CONC":".018","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"1539847","CASS_NUM":"57977845","SMP_TAKEN_DT":"7/3/2012","CONC":".172","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"1393638","CASS_NUM":"57977829","SMP_TAKEN_DT":"7/3/2012","CONC":".106","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"1001458","CASS_NUM":"57977817","SMP_TAKEN_DT":"7/3/2012","CONC":".294","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"918594","CASS_NUM":"57977855","SMP_TAKEN_DT":"7/3/2012","CONC":".227","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SUPERINTENDENT","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"757305","CASS_NUM":"57977950","SMP_TAKEN_DT":"7/3/2012","CONC":".115","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"106500","CASS_NUM":"57977822","SMP_TAKEN_DT":"7/3/2012","CONC":".188","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"16082","CASS_NUM":"57978098","SMP_TAKEN_DT":"7/3/2012","CONC":".048","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"FINE COAL PLANT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"922360","CASS_NUM":"57953078","SMP_TAKEN_DT":"12/29/2011","CONC":".034","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-29"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2007-04-20","lastDate":"2013-01-16","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":35,"firstDate":"2007-09-13","lastDate":"2013-08-26","metrics":{"inspectors":52,"recentRows":0,"onSiteHours":410.5,"inspectionHours":637.75,"inspectionSamples":113},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"785826","EVENT_NO":"4496837","INSPECTION_BEGIN_DT":"08/26/2013","INSPECTION_END_DT":"08/26/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.25","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2013-08-26"},{"SOURCE_ROW_NUMBER":"688674","EVENT_NO":"4496715","INSPECTION_BEGIN_DT":"03/13/2013","INSPECTION_END_DT":"03/13/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"392229","EVENT_NO":"4496818","INSPECTION_BEGIN_DT":"02/28/2013","INSPECTION_END_DT":"03/06/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"38.75","SUM_TOTAL_ON_SITE_HOURS":"19.25","sourceDate":"2013-02-28"},{"SOURCE_ROW_NUMBER":"966020","EVENT_NO":"4494839","INSPECTION_BEGIN_DT":"07/03/2012","INSPECTION_END_DT":"07/12/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"20.5","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"224328","EVENT_NO":"4495242","INSPECTION_BEGIN_DT":"12/29/2011","INSPECTION_END_DT":"01/10/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2011-12-29"},{"SOURCE_ROW_NUMBER":"461428","EVENT_NO":"4495674","INSPECTION_BEGIN_DT":"11/07/2011","INSPECTION_END_DT":"11/07/2011","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2011-11-07"},{"SOURCE_ROW_NUMBER":"580026","EVENT_NO":"4494455","INSPECTION_BEGIN_DT":"10/05/2011","INSPECTION_END_DT":"10/28/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"42","SUM_TOTAL_ON_SITE_HOURS":"26.25","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"1160319","EVENT_NO":"4494069","INSPECTION_BEGIN_DT":"08/23/2011","INSPECTION_END_DT":"08/25/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.75","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2011-08-23"},{"SOURCE_ROW_NUMBER":"46603","EVENT_NO":"4494434","INSPECTION_BEGIN_DT":"04/05/2011","INSPECTION_END_DT":"05/02/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"56","SUM_TOTAL_ON_SITE_HOURS":"35.25","sourceDate":"2011-04-05"},{"SOURCE_ROW_NUMBER":"825279","EVENT_NO":"4495207","INSPECTION_BEGIN_DT":"03/11/2011","INSPECTION_END_DT":"03/24/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.75","SUM_TOTAL_ON_SITE_HOURS":"8.25","sourceDate":"2011-03-11"},{"SOURCE_ROW_NUMBER":"1020583","EVENT_NO":"4494411","INSPECTION_BEGIN_DT":"11/21/2010","INSPECTION_END_DT":"03/18/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"47.5","SUM_TOTAL_ON_SITE_HOURS":"34.75","sourceDate":"2010-11-21"},{"SOURCE_ROW_NUMBER":"837234","EVENT_NO":"4491696","INSPECTION_BEGIN_DT":"11/09/2010","INSPECTION_END_DT":"11/09/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2010-11-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":94,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2015-Q1":{"hours":0,"employees":0,"production":0},"2014-Q4":{"hours":0,"employees":0,"production":0},"2014-Q3":{"hours":0,"employees":0,"production":0},"2014-Q2":{"hours":0,"employees":0,"production":0},"2014-Q1":{"hours":0,"employees":0,"production":0},"2013-Q4":{"hours":0,"employees":0,"production":0},"2013-Q3":{"hours":0,"employees":0,"production":0},"2013-Q2":{"hours":2184,"employees":7,"production":0},"2013-Q1":{"hours":3701,"employees":7,"production":0},"2012-Q4":{"hours":12422,"employees":24,"production":12912},"2012-Q3":{"hours":18800,"employees":36,"production":23731},"2012-Q2":{"hours":15758,"employees":34,"production":23474}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":20,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007":{"hours":27034,"employees":20,"production":54554},"2008":{"hours":61337,"employees":26,"production":318093},"2009":{"hours":20451,"employees":10,"production":23945},"2010":{"hours":59883,"employees":24,"production":202358},"2011":{"hours":54634,"employees":26,"production":104096},"2012":{"hours":63058,"employees":32,"production":107577},"2013":{"hours":5885,"employees":7,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":47,"firstDate":"2007-09-19","lastDate":"2013-03-13","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":2201,"pelDoseTotal":1418},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"10706","EVENT_NO":"4496715","SURVEY_DATE":"03/13/2013","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"21","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"10705","EVENT_NO":"4496715","SURVEY_DATE":"03/13/2013","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"041","ACT_DOSE_85":"38","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"10704","EVENT_NO":"4496715","SURVEY_DATE":"03/13/2013","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"31","MANUFACTURER_CD":"063","ACT_DOSE_85":"62","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"10703","EVENT_NO":"4496715","SURVEY_DATE":"03/13/2013","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"88","PEL_DOSE_90":"63","SURVEY_TYPE":"I","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"10702","EVENT_NO":"4494839","SURVEY_DATE":"07/03/2012","OCCUPATION_CD_DESC":"SUPERINTENDENT","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"4","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"10701","EVENT_NO":"4494839","SURVEY_DATE":"07/03/2012","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"31","MANUFACTURER_CD":"063","ACT_DOSE_85":"24","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"10700","EVENT_NO":"4494839","SURVEY_DATE":"07/03/2012","OCCUPATION_CD_DESC":"FINE COAL PLANT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"36","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"10699","EVENT_NO":"4494839","SURVEY_DATE":"07/03/2012","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"31","MANUFACTURER_CD":"063","ACT_DOSE_85":"10","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"10698","EVENT_NO":"4494839","SURVEY_DATE":"07/03/2012","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"7","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"10697","EVENT_NO":"4494839","SURVEY_DATE":"07/03/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"40","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"10696","EVENT_NO":"4494839","SURVEY_DATE":"07/03/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"17","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"10695","EVENT_NO":"4494411","SURVEY_DATE":"03/18/2011","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"31","MANUFACTURER_CD":"063","ACT_DOSE_85":"94","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2011-03-18"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":37,"firstDate":"2007-11-14","lastDate":"2012-07-05","metrics":{"ss":3,"amountDue":5165,"contested":0,"amountPaid":5165,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":5165},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"90761","VIOLATION_NO":"8523870","VIOLATION_ISSUE_DT":"07/05/2012","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/05/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-05"},{"SOURCE_ROW_NUMBER":"90760","VIOLATION_NO":"8523869","VIOLATION_ISSUE_DT":"07/05/2012","SIG_SUB":"N","PART_SECTION":"77.1103(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/05/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-05"},{"SOURCE_ROW_NUMBER":"90767","VIOLATION_NO":"8521051","VIOLATION_ISSUE_DT":"10/27/2011","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/27/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"90766","VIOLATION_NO":"8521050","VIOLATION_ISSUE_DT":"10/27/2011","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/27/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"90765","VIOLATION_NO":"8521049","VIOLATION_ISSUE_DT":"10/27/2011","SIG_SUB":"Y","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/27/2011","PROPOSED_PENALTY":"308","AMOUNT_DUE":"308","AMOUNT_PAID":"308","CONTESTED_IND":"N","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"90764","VIOLATION_NO":"8521046","VIOLATION_ISSUE_DT":"10/19/2011","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/19/2011","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"90763","VIOLATION_NO":"8521045","VIOLATION_ISSUE_DT":"10/19/2011","SIG_SUB":"N","PART_SECTION":"77.505","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/27/2011","PROPOSED_PENALTY":"308","AMOUNT_DUE":"308","AMOUNT_PAID":"308","CONTESTED_IND":"N","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"90762","VIOLATION_NO":"8521044","VIOLATION_ISSUE_DT":"10/19/2011","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/19/2011","PROPOSED_PENALTY":"308","AMOUNT_DUE":"308","AMOUNT_PAID":"308","CONTESTED_IND":"N","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"90748","VIOLATION_NO":"8518097","VIOLATION_ISSUE_DT":"04/13/2011","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/14/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-04-13"},{"SOURCE_ROW_NUMBER":"90747","VIOLATION_NO":"8518096","VIOLATION_ISSUE_DT":"04/13/2011","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-04-13"},{"SOURCE_ROW_NUMBER":"90746","VIOLATION_NO":"8518095","VIOLATION_ISSUE_DT":"04/13/2011","SIG_SUB":"N","PART_SECTION":"77.210(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/13/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-04-13"},{"SOURCE_ROW_NUMBER":"90745","VIOLATION_NO":"8518094","VIOLATION_ISSUE_DT":"04/05/2011","SIG_SUB":"N","PART_SECTION":"77.206(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/05/2011","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2011-04-05"}]}],"safety":{"href":"/api/v1/mines/0103362/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/0103362/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":4},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.505","heading":"Cable fittings; suitability.","id":"77.505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.505","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Cables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires, other than cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","heading":"Hoisting of materials.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.210","part":"77","subchapter":"O","subpart":"C","id":"77.210","citation":"30 CFR 77.210","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.206","heading":"Ladders; construction; installation and maintenance.","id":"77.206","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.206","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Ladders shall be of substantial construction and maintained in good condition.\n\n(b) Wooden members of ladders shall not be painted.\n\n(c) Steep or vertical ladders which are used regularly at fixed locations shall be anchored securely and provided with backguards extending from a point not more than 7 feet from the bottom of the ladder to the top of the ladder.\n\n(d) Fixed ladders shall not incline backwards at any point unless provided with backguards.\n\n(e) Fixed ladders shall be anchored securely and installed to provide at least 3 inches of toe clearance.\n\n(f) Fixed ladders shall project at least 3 feet above landings, or substantial handholds shall be provided above the landings.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"0103362","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}