{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"0100742","name":"Short Creek 8750","status":"Abandoned","status_date":"2026-05-21","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"AL","county":"Jefferson","nearest_town":"Short Creek","operator_id":"P17353","operator_name":"Drummond Company, Inc.","controller_id":"C00866","controller_name":"Drummond Company Inc","district":"M3","office":"Birmingham AL Field Office (A)","employees":0,"latitude":33.569444,"longitude":-87.080556},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":871},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"0100742","name":"Short Creek 8750"},"operator":{"type":"operator","id":"P17353","name":"Drummond Company, Inc."},"controller":{"type":"controller","id":"C00866","name":"Drummond Company Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P01016","name":"Taylor Coal Company Inc"},"object":{"type":"mine","id":"0100742","name":"Short Creek 8750"},"validFrom":"1950-01-01","validTo":"1980-05-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"0100742|P01016|1950-01-01|1980-05-22"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00864","name":"Taylor Walter Scott Sr & Jr"},"object":{"type":"mine","id":"0100742","name":"Short Creek 8750"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"0100742|C00864|1950-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00864","name":"Taylor Walter Scott Sr & Jr"},"object":{"type":"operator","id":"P01016","name":"Taylor Coal Company Inc"},"validFrom":"1950-01-01","validTo":"1980-05-22","current":false,"derived":true,"evidenceMineId":"0100742","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"0100742|P01016|1950-01-01|C00864|1950-01-01|50581"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00866","name":"Drummond Company Inc"},"object":{"type":"mine","id":"0100742","name":"Short Creek 8750"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"0100742|C00866|1950-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17353","name":"Drummond Company, Inc."},"object":{"type":"mine","id":"0100742","name":"Short Creek 8750"},"validFrom":"1980-05-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"0100742|P17353|1980-05-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00866","name":"Drummond Company Inc"},"object":{"type":"operator","id":"P17353","name":"Drummond Company, Inc."},"validFrom":"1980-05-23","validTo":null,"current":true,"derived":true,"evidenceMineId":"0100742","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"0100742|P17353|1980-05-23|C00866|1950-01-01|50620"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":7,"firstDate":"2005-01-14","lastDate":"2008-09-12","metrics":{"daysLost":94,"injuries":7,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"120325","DOCUMENT_NO":"220083400010","ACCIDENT_DT":"09/12/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","DAYS_LOST":"40","NARRATIVE":"Employee was sitting on a pipe that was suspended with chain falls.  He was cleaning some of his tools.  The pipe shifted when someone else hit it and smashed his foot between the pipe and the floor.","sourceDate":"2008-09-12"},{"SOURCE_ROW_NUMBER":"185017","DOCUMENT_NO":"220083400003","ACCIDENT_DT":"09/09/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","DAYS_LOST":"28","NARRATIVE":"EE had been pulling on a chain fall for several days and on this day, he started to complain about his arm hurting and going numb.  We found out later that he had a pre-existing arm injury we were unaware of.","sourceDate":"2008-09-09"},{"SOURCE_ROW_NUMBER":"128816","DOCUMENT_NO":"220060730019","ACCIDENT_DT":"03/10/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Coal/ore shovel operator,  Shoveler,  Power shoveler","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Rock fell from overhead belt, bouncing off the floor of backhoe the employee was operating (canopy is in place and in good working order).  Rock bruised right ankle.","sourceDate":"2006-03-10"},{"SOURCE_ROW_NUMBER":"146235","DOCUMENT_NO":"220060470018","ACCIDENT_DT":"02/10/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The employee stepped on a lump of coal causing him to trip over a pipe and fall to the ground. He tried to catch himself with his left hand, causing injury to the left wrist.","sourceDate":"2006-02-10"},{"SOURCE_ROW_NUMBER":"73044","DOCUMENT_NO":"220052510015","ACCIDENT_DT":"08/24/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALLING/SLIDING/ROLLING MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Superintendent","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"This is to report medical treatment only. While attempting to fasten a regulator door on the #1 run of mine feeder, the employees right ring finger was struck by a rock that fell from the top of the hopper to the feeder. This resulted in a laceration requiring (4) sutures and a frature of the distal phalange of the 3rd finger, right hand.","sourceDate":"2005-08-24"},{"SOURCE_ROW_NUMBER":"262536","DOCUMENT_NO":"220051430014","ACCIDENT_DT":"05/15/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"Employee was kneeling on a beam, welding - he twisted and felt pain in his lower back.","sourceDate":"2005-05-15"},{"SOURCE_ROW_NUMBER":"159203","DOCUMENT_NO":"220050240056","ACCIDENT_DT":"01/14/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Removing a piece of chutework, the chute became lodged in the hole from which it was being removed from the plant, the ee pryed the chute to free it. Due to the forces of the rigging the chute sank into the ee's left foot when it was freed.","sourceDate":"2005-01-14"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-05-21","lastDate":"2026-05-21","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":18,"firstDate":"2005-07-06","lastDate":"2006-01-17","metrics":{"ss":4,"delinquent":12,"recentRows":0,"paidPenalty":1333,"proposedPenalty":1333,"currentAssessment":1333},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1297040","VIOLATION_NO":"7686561","ISSUE_DT":"01/17/2006","CFR_STANDARD_CD":"62.130(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-01-17"},{"SOURCE_ROW_NUMBER":"1297039","VIOLATION_NO":"7686560","ISSUE_DT":"01/17/2006","CFR_STANDARD_CD":"62.130(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-01-17"},{"SOURCE_ROW_NUMBER":"1297576","VIOLATION_NO":"7687412","ISSUE_DT":"12/05/2005","CFR_STANDARD_CD":"77.409(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"1297575","VIOLATION_NO":"7687411","ISSUE_DT":"12/05/2005","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"1297577","VIOLATION_NO":"7687413","ISSUE_DT":"12/01/2005","CFR_STANDARD_CD":"62.130(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1297574","VIOLATION_NO":"7687410","ISSUE_DT":"12/01/2005","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1297573","VIOLATION_NO":"7687409","ISSUE_DT":"12/01/2005","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1297572","VIOLATION_NO":"7687408","ISSUE_DT":"12/01/2005","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1297571","VIOLATION_NO":"7687407","ISSUE_DT":"12/01/2005","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1297570","VIOLATION_NO":"7687406","ISSUE_DT":"11/30/2005","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-11-30"},{"SOURCE_ROW_NUMBER":"1297569","VIOLATION_NO":"7687405","ISSUE_DT":"11/30/2005","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-11-30"},{"SOURCE_ROW_NUMBER":"1297568","VIOLATION_NO":"7687404","ISSUE_DT":"11/30/2005","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-11-30"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":25,"firstDate":"2005-07-07","lastDate":"2006-06-01","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":7,"validSamples":18,"maxConcentration":1.591,"concentrationTotal":10.118},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1212953","CASS_NUM":"57643202","SMP_TAKEN_DT":"6/1/2006","CONC":".122","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WASHER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-01"},{"SOURCE_ROW_NUMBER":"629203","CASS_NUM":"57643203","SMP_TAKEN_DT":"6/1/2006","CONC":".182","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-01"},{"SOURCE_ROW_NUMBER":"737467","CASS_NUM":"50838103","SMP_TAKEN_DT":"5/4/2006","CONC":".874","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-05-04"},{"SOURCE_ROW_NUMBER":"61071","CASS_NUM":"50838129","SMP_TAKEN_DT":"2/7/2006","CONC":".317","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-02-07"},{"SOURCE_ROW_NUMBER":"498953","CASS_NUM":"50799651","SMP_TAKEN_DT":"12/12/2005","CONC":".721","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-12-12"},{"SOURCE_ROW_NUMBER":"437725","CASS_NUM":"50799631","SMP_TAKEN_DT":"12/8/2005","CONC":".848","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"OPERATOR VOID; PRODUCTION","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-12-08"},{"SOURCE_ROW_NUMBER":"1393642","CASS_NUM":"57580263","SMP_TAKEN_DT":"12/1/2005","CONC":".258","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1363948","CASS_NUM":"57580346","SMP_TAKEN_DT":"12/1/2005","CONC":".777","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1318057","CASS_NUM":"57580387","SMP_TAKEN_DT":"12/1/2005","CONC":".3","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WASHER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1071270","CASS_NUM":"57580295","SMP_TAKEN_DT":"12/1/2005","CONC":".057","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"1014579","CASS_NUM":"57580345","SMP_TAKEN_DT":"12/1/2005","CONC":".324","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WASHER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"431853","CASS_NUM":"57580302","SMP_TAKEN_DT":"12/1/2005","CONC":".885","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-12-01"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2006-02-23","lastDate":"2006-02-23","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":681,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":65,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1950-01-01","lastDate":"1980-05-23","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":29,"firstDate":"2005-06-15","lastDate":"2025-01-29","metrics":{"inspectors":31,"recentRows":2,"onSiteHours":106.25,"inspectionHours":182.5,"inspectionSamples":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"661120","EVENT_NO":"6920850","INSPECTION_BEGIN_DT":"01/29/2025","INSPECTION_END_DT":"01/29/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9.25","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2025-01-29"},{"SOURCE_ROW_NUMBER":"378953","EVENT_NO":"F00EE59","INSPECTION_BEGIN_DT":"10/08/2024","INSPECTION_END_DT":"10/10/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2024-10-08"},{"SOURCE_ROW_NUMBER":"368114","EVENT_NO":"6493016","INSPECTION_BEGIN_DT":"12/21/2016","INSPECTION_END_DT":"12/21/2016","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.75","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2016-12-21"},{"SOURCE_ROW_NUMBER":"679025","EVENT_NO":"4496812","INSPECTION_BEGIN_DT":"02/19/2013","INSPECTION_END_DT":"02/19/2013","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2013-02-19"},{"SOURCE_ROW_NUMBER":"511112","EVENT_NO":"4494486","INSPECTION_BEGIN_DT":"08/16/2012","INSPECTION_END_DT":"08/16/2012","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2012-08-16"},{"SOURCE_ROW_NUMBER":"864449","EVENT_NO":"4494449","INSPECTION_BEGIN_DT":"08/08/2011","INSPECTION_END_DT":"08/08/2011","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2011-08-08"},{"SOURCE_ROW_NUMBER":"883676","EVENT_NO":"4493040","INSPECTION_BEGIN_DT":"10/27/2010","INSPECTION_END_DT":"10/27/2010","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2010-10-27"},{"SOURCE_ROW_NUMBER":"362875","EVENT_NO":"4493029","INSPECTION_BEGIN_DT":"07/08/2010","INSPECTION_END_DT":"07/08/2010","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2010-07-08"},{"SOURCE_ROW_NUMBER":"234415","EVENT_NO":"4493966","INSPECTION_BEGIN_DT":"02/11/2010","INSPECTION_END_DT":"02/11/2010","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2010-02-11"},{"SOURCE_ROW_NUMBER":"520273","EVENT_NO":"4492556","INSPECTION_BEGIN_DT":"09/23/2009","INSPECTION_END_DT":"09/23/2009","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2009-09-23"},{"SOURCE_ROW_NUMBER":"1056694","EVENT_NO":"4492111","INSPECTION_BEGIN_DT":"02/12/2009","INSPECTION_END_DT":"02/12/2009","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2009-02-12"},{"SOURCE_ROW_NUMBER":"137446","EVENT_NO":"4491066","INSPECTION_BEGIN_DT":"04/29/2008","INSPECTION_END_DT":"04/29/2008","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2008-04-29"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":29267,"employees":10,"production":0},"2006":{"hours":15172,"employees":9,"production":0},"2026":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2005-07-12","lastDate":"2006-06-01","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":1057,"pelDoseTotal":790},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"444","EVENT_NO":"4297595","SURVEY_DATE":"06/01/2006","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"22","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2006-06-01"},{"SOURCE_ROW_NUMBER":"443","EVENT_NO":"4297595","SURVEY_DATE":"06/01/2006","OCCUPATION_CD_DESC":"WASHER OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"45","PEL_DOSE_90":"36","SURVEY_TYPE":"F","sourceDate":"2006-06-01"},{"SOURCE_ROW_NUMBER":"442","EVENT_NO":"4297388","SURVEY_DATE":"12/01/2005","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"215","PEL_DOSE_90":"202","SURVEY_TYPE":"I","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"441","EVENT_NO":"4297388","SURVEY_DATE":"12/01/2005","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"119","ACT_DOSE_85":"27","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"440","EVENT_NO":"4297388","SURVEY_DATE":"12/01/2005","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"64","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"439","EVENT_NO":"4297388","SURVEY_DATE":"12/01/2005","OCCUPATION_CD_DESC":"WASHER OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"57","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"438","EVENT_NO":"4297388","SURVEY_DATE":"12/01/2005","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"78","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"437","EVENT_NO":"4297388","SURVEY_DATE":"12/01/2005","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"42","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"436","EVENT_NO":"4297388","SURVEY_DATE":"12/01/2005","OCCUPATION_CD_DESC":"WASHER OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"123","PEL_DOSE_90":"105","SURVEY_TYPE":"I","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"435","EVENT_NO":"4295892","SURVEY_DATE":"07/12/2005","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"57","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2005-07-12"},{"SOURCE_ROW_NUMBER":"434","EVENT_NO":"4295892","SURVEY_DATE":"07/12/2005","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"51","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2005-07-12"},{"SOURCE_ROW_NUMBER":"433","EVENT_NO":"4295892","SURVEY_DATE":"07/12/2005","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"119","ACT_DOSE_85":"3","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2005-07-12"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":1,"firstDate":"2005-12-01","lastDate":"2005-12-01","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":1.5,"validSamples":1,"quartzPctTotal":1.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"134694","CASSETTE_NO":"57580346","SAMPLE_DT":"12/01/2005","QUARTZ_PCT":"01.5","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-12-01"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":18,"firstDate":"2005-07-06","lastDate":"2006-01-17","metrics":{"ss":4,"amountDue":1333,"contested":0,"amountPaid":1333,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":1333},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"15116","VIOLATION_NO":"7686561","VIOLATION_ISSUE_DT":"01/17/2006","SIG_SUB":"N","PART_SECTION":"62.130(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/01/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-01-17"},{"SOURCE_ROW_NUMBER":"15115","VIOLATION_NO":"7686560","VIOLATION_ISSUE_DT":"01/17/2006","SIG_SUB":"N","PART_SECTION":"62.130(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/01/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-01-17"},{"SOURCE_ROW_NUMBER":"15131","VIOLATION_NO":"7687412","VIOLATION_ISSUE_DT":"12/05/2005","SIG_SUB":"N","PART_SECTION":"77.409(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/05/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"15130","VIOLATION_NO":"7687411","VIOLATION_ISSUE_DT":"12/05/2005","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/05/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"15132","VIOLATION_NO":"7687413","VIOLATION_ISSUE_DT":"12/01/2005","SIG_SUB":"N","PART_SECTION":"62.130(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/01/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"15129","VIOLATION_NO":"7687410","VIOLATION_ISSUE_DT":"12/01/2005","SIG_SUB":"N","PART_SECTION":"77.1103(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/05/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"15128","VIOLATION_NO":"7687409","VIOLATION_ISSUE_DT":"12/01/2005","SIG_SUB":"N","PART_SECTION":"77.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/05/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"15127","VIOLATION_NO":"7687408","VIOLATION_ISSUE_DT":"12/01/2005","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/01/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"15126","VIOLATION_NO":"7687407","VIOLATION_ISSUE_DT":"12/01/2005","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/01/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"15125","VIOLATION_NO":"7687406","VIOLATION_ISSUE_DT":"11/30/2005","SIG_SUB":"Y","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/05/2005","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2005-11-30"},{"SOURCE_ROW_NUMBER":"15124","VIOLATION_NO":"7687405","VIOLATION_ISSUE_DT":"11/30/2005","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/30/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-11-30"},{"SOURCE_ROW_NUMBER":"15123","VIOLATION_NO":"7687404","VIOLATION_ISSUE_DT":"11/30/2005","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/05/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-11-30"}]}],"safety":{"href":"/api/v1/mines/0100742/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/0100742/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 62.130","heading":"Permissible exposure level.","id":"62.130","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-M/part-62/section-62.130","part":"62","partHeading":"PART 62—OCCUPATIONAL NOISE EXPOSURE","subchapter":"M","subchapterHeading":"SUBCHAPTER M—UNIFORM MINE HEALTH REGULATIONS","subpart":"","subpartHeading":"","text":"(a) The mine operator must assure that no miner is exposed during any work shift to noise that exceeds the permissible exposure level. If during any work shift a miner's noise exposure exceeds the permissible exposure level, the mine operator must use all feasible engineering and administrative controls to reduce the miner's noise exposure to the permissible exposure level, and enroll the miner in a hearing conservation program that complies with § 62.150 of this part. When a mine operator uses administrative controls to reduce a miner's exposure, the mine operator must post the procedures for such controls on the mine bulletin board and provide a copy to the affected miner.\n\n(b) If a miner's noise exposure continues to exceed the permissible exposure level despite the use of all feasible engineering and administrative controls, the mine operator must continue to use the engineering and administrative controls to reduce the miner's noise exposure to as low a level as is feasible.\n\n(c) The mine operator must assure that no miner is exposed at any time to sound levels exceeding 115 dBA, as determined without adjustment for the use of any hearing protector.","occurrenceCount":3},{"chapter":"I","heading":"Shovels, draglines, and tractors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.409","part":"77","subchapter":"O","subpart":"E","id":"77.409","citation":"30 CFR 77.409","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.512","heading":"Inspection and cover plates.","id":"77.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.512","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Inspection and cover plates on electrical equipment shall be kept in place at all times except during testing or repairs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"0100742","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}